Antibodies against enteroviruses in intravenous Ig preparations: great variation in titres and poor correlation with the incidence of circulating serotypes.
J Med Virol
; 53(3): 273-6, 1997 Nov.
Article
em En
| MEDLINE
| ID: mdl-9365895
Antibody titres in immunoglobulin preparations for intravenous use were tested against 24 different enterovirus serotypes and varied between 1:100 and 1:10,000 within a single batch. Differences up to 8-fold were found for homologous titres between two different batches that were prepared 6 years apart. The lowest titre obtained was 1:40. The observed differences within and between the two batches could not be explained by different incidence of serotypes of enteroviruses circulating at the time blood was collected. Differences in titres of up to 18-fold were observed when several strains of the same serotype were tested suggesting that intratypic variation influences antibody titres. It is concluded that immunoglobulin preparations contain antibodies against many enteroviruses, but that titres can be low and cannot be predicted from the incidence of any particular serotype circulating in the community. Because of intratypic variation, selection of a batch for specific treatment should be based on results obtained with the patient's own isolate, and not with a reference strain.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Imunoglobulinas Intravenosas
/
Enterovirus
/
Anticorpos Antivirais
Tipo de estudo:
Incidence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
País/Região como assunto:
Europa
Idioma:
En
Revista:
J Med Virol
Ano de publicação:
1997
Tipo de documento:
Article
País de afiliação:
Holanda
País de publicação:
Estados Unidos