Use of a phosphorus-enriched hemodialysate to prevent hypophosphatemia in a patient with renal failure-related pericarditis.
Emelife-Obi, C; Chow, M T; Qamar-Rohail, H; Leehey, D J; Gandhi, V C; Ing, T S.
Afiliação
  • Emelife-Obi C; Department of Medicine, Veterans Affairs Hospital, Hines, Illinois 60141, USA.
Clin Nephrol ; 50(2): 131-3, 1998 Aug.
Article em En | MEDLINE | ID: mdl-9725787
We describe a patient who suffered from renal failure-associated pericarditis and underwent daily 3.5-hour hemodialysis treatments for 17 days. The initially elevated serum phosphorus level gradually fell to below normal on days 11 and 12 as a result of the intensive dialytic therapy. Phosphorus was added to the "base concentrate" of a dual-concentrate, bicarbonate-based dialysate delivery system on days 13 to 17. Because of this phosphorus-enrichment, we were able to maintain the patient's serum phosphorus levels within normal limits in spite of continued daily dialysis treatments.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pericardite / Fósforo / Soluções para Hemodiálise / Hipofosfatemia / Falência Renal Crônica Limite: Humans / Middle aged Idioma: En Revista: Clin Nephrol Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pericardite / Fósforo / Soluções para Hemodiálise / Hipofosfatemia / Falência Renal Crônica Limite: Humans / Middle aged Idioma: En Revista: Clin Nephrol Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha