Your browser doesn't support javascript.
loading
Comparison of lung volume measurements by antero-posterior chest X-ray and the SF6 washout technique in mechanically ventilated infants.
Thome, U; Töpfer, A; Schaller, P; Pohlandt, F.
Afiliação
  • Thome U; Department of Pediatrics, University of Ulm, Germany.
Pediatr Pulmonol ; 26(4): 265-72, 1998 Oct.
Article em En | MEDLINE | ID: mdl-9811077
While anterior/posterior chest x-rays (CXR) are routinely performed to estimate lung volume (LV) and adjust ventilator settings, the precise measurement of LV requires additional sophistication. In 31 infants ventilated because of surfactant deficiency (n=23), bronchopulmonary dysplasia (n=7), or pulmonary hypoplasia (n=1) with either intermittent positive pressure (n=18) or high frequency oscillation (n=13) (gestational age 23-39 weeks (median 26 weeks); birthweight 550-2780 g (median 840 g); age at measurement 1-91 days (median 6 days); weight at study time (WST) 675-3000 g (median 938 g)), we investigated whether LV, as measured by the sulfur hexafluoride (SF6) washout technique, could by estimated from CXR by: 1) the sum (A+B) of the right (A) and left (B) lung fields areas; 2) the product (LxW) of the distances from the right apex to the right costophrenic angle (L) and between both costophrenic angles (W); 3) the diaphragm position relative to the posterior parts of the ribs (DP); and 4) the lung radiolucency (RL, grades 0-4). Correlations between A+B (r=0.44) or LxW (r=0.37) and LV were poor, but improved when A+B, LxW, and LV were normalized to WST: (A+B)/WST vs. LV/WST (r=0.74), and LxW/WST vs. LV/WST (r=0.67). DP (r=0.13) and RL (Spearman's rho=0.17) did not correlate with LV/WST. A multiple linear regression analysis led to the following best-fit equation: LV/WST=2.58 (A+B)/WST - 5.47 DP + 42.2 (r=0.83). We concluded that an estimate of LV from CXR lacked sufficient accuracy. DP and RL did not correlate with LV measured by SF6 washout.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Hexafluoreto de Enxofre / Pulmão / Medidas de Volume Pulmonar Limite: Humans / Newborn Idioma: En Revista: Pediatr Pulmonol Assunto da revista: PEDIATRIA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração Artificial / Hexafluoreto de Enxofre / Pulmão / Medidas de Volume Pulmonar Limite: Humans / Newborn Idioma: En Revista: Pediatr Pulmonol Assunto da revista: PEDIATRIA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos