Your browser doesn't support javascript.
loading
Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.
Erdi, A K; Yorke, E D; Loew, M H; Erdi, Y E; Sarfaraz, M; Wessels, B W.
Afiliação
  • Erdi AK; Memorial Sloan-Kettering Cancer Center, Department of Medical Physics, New York, New York 10021, USA. erdia@mskcc.org
Med Phys ; 25(11): 2226-33, 1998 Nov.
Article em En | MEDLINE | ID: mdl-9829250
ABSTRACT
Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation of the three-dimensional absorbed dose distribution requires convolution of a cumulated activity distribution matrix with a point-source kernel; both are represented by large matrices (64 x 64 x 64). To reduce the computation time required for these calculations, an implementation of convolution using three-dimensional (3-D) fast Hartley transform (FHT) is realized. Using the 3-D FHT convolution, absorbed dose calculation time was reduced over 1000 times. With this system, fast and accurate absorbed dose calculations are possible in radioimmunotherapy. This approach was validated in simple geometries and then was used to calculate the absorbed dose distribution for a patient's tumor and a bone marrow sample.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Dosagem Radioterapêutica / Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada por Raios X / Radioimunoterapia / Imagens de Fantasmas Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Dosagem Radioterapêutica / Planejamento da Radioterapia Assistida por Computador / Tomografia Computadorizada por Raios X / Radioimunoterapia / Imagens de Fantasmas Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA