Your browser doesn't support javascript.
loading
Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours.
Chace, D H; Sherwin, J E; Hillman, S L; Lorey, F; Cunningham, G C.
Afiliação
  • Chace DH; 1 Neo Gen Screening, 110 Roessler Road, Pittsburgh, PA 15220, USA. dhchace@neogenscreening.com
Clin Chem ; 44(12): 2405-9, 1998 Dec.
Article em En | MEDLINE | ID: mdl-9836704
ABSTRACT
We compared the screening interpretation of fluorometric analytical results for phenylketonuria (PKU) with tandem mass spectrometry (MS/MS) in filter paper blood spots collected from newborns <24 h of age. In MS/MS, both Phe and Tyr are quantified. Two hundred and eight blood spots collected from infants <24 h of age were retrieved from storage from the California newborn screening program. These samples had been categorized on the basis of fluorometric analysis as initial negative, initial positive for hyperphenylalaninemia with negative determination on recall, or initial positive for hyperphenylalaninemia and confirmed on follow up as PKU or variant hyperphenylalaninemia. The retrieved samples were analyzed in a blinded fashion using MS/MS. Correlation analysis of fluorometry vs MS/MS for Phe concentration was high, with a Pearson correlation coefficient of 0.817. When 180 micromol/L was used as the cutoff Phe concentration for MS/MS and 258 micromol/L was used as the cutoff for fluorometry, all infants with confirmed classical PKU and variant hyperphenylalaninemia were detected. MS/MS analysis reduced the number of false-positive results from 91 to 3. Simultaneous quantification of Phe and Tyr by MS/MS with the use of a cutoff Phe/Tyr molar ratio of 2.5 further reduced the number of false positives to 1. Samples from affected infants showed a discernible trend of increasing Phe concentration and Phe/Tyr molar ratio with age of collection. These results demonstrate the utility of MS/MS in the routine PKU screening of early-discharge newborns. MS/MS reduces the false-positive rate of fluorometric screening almost 100-fold because of the improved accuracy and precision of Phe measurement and simultaneous confirmation with the Phe/Tyr molar ratio. In addition to the detection of PKU, MS/MS can also detect other aminoacidopathies and disorders of fatty acid and organic acid metabolism with lower false-positive rates than other methods currently used in newborn screening programs.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenilalanina / Fenilcetonúrias / Tirosina / Triagem Neonatal Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans / Newborn Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenilalanina / Fenilcetonúrias / Tirosina / Triagem Neonatal Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans / Newborn Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 1998 Tipo de documento: Article País de afiliação: Estados Unidos