A method for comparing endotracheal cuffs: a controlled study of tracheal trauma in dogs
Br J Anaesth ; 50(5): 435-44, May 1978.
Artigo em Inglês | MedCarib | ID: med-2109
Biblioteca responsável: JM3.1
Localização: JM3.1; RD79.A1B7
ABSTRACT
Damage to the trachea produced in dogs by large and small residual volume cuffs during 6 h of IPPV was compared using a specifically designed endotracheal tube. The cuffs under evaluation were adjusted to exert similar average pressures on the tracheal walls, so that many of the variables believed responsible for tracheal injury were controlled. The tube compliance of the cuff was measured with tube inside and outside the trachea of the anesthetized dogs. The maximum estimated pressure transmitted to the tracheal wall, derived from these compliance curves, was found to equal the peak airway pressure in the presence of a small air leak past each cuff. At various tracheal wall pressures there were only minor differences in tracheal damage between the large and small residual volume cuffs tested (AU).
Assuntos
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: MedCarib Assunto principal: Traqueia / Intubação Intratraqueal Limite: Animais Idioma: Inglês Revista: Br J Anaesth Ano de publicação: 1978 Tipo de documento: Artigo
Buscar no Google