Your browser doesn't support javascript.
loading
Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial
Costa Junior, J. Ribamar; Chamié, Daniel; Abizaid, Alexandre A. C; Ribeiro, Expedito; Meireles, George C; Prudente, Maurício; Campos, Carlos A; Castro, Juliana P; Costa, Ricardo; Lemos, Pedro A.
Afiliação
  • Costa Junior, J. Ribamar; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Chamié, Daniel; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Abizaid, Alexandre A. C; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Ribeiro, Expedito; University of São Paulo Medical School. São Paulo. BR
  • Meireles, George C; Hospital do Servidor Público Estadual-IAMSPE. São Paulo. BR
  • Prudente, Maurício; Hospital Encore. Aparecida de Goiânia. BR
  • Campos, Carlos A; University of São Paulo Medical School. São Paulo. BR
  • Castro, Juliana P; Cardiovascular Research Center. São Paulo. BR
  • Costa, Ricardo; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Lemos, Pedro A; University of São Paulo Medical School. São Paulo. BR
Int J Cardiovasc Imaging ; 33(2): 161-168, 2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063485
Biblioteca responsável: BR79.1
Localização: BR79.1
ABSTRACT
We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (21) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™ n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™ n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001)...
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Brasil Base de dados: Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Sirolimo / Stents Farmacológicos Tipo de estudo: Ensaio clínico controlado Idioma: Inglês Revista: Int J Cardiovasc Imaging Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Cardiovascular Research Center/BR / Hospital Encore/BR / Hospital do Servidor Público Estadual-IAMSPE/BR / Instituto Dante Pazzanese de Cardiologia/BR / University of São Paulo Medical School/BR
Buscar no Google
Coleções: Bases de dados nacionais / Brasil Base de dados: Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Sirolimo / Stents Farmacológicos Tipo de estudo: Ensaio clínico controlado Idioma: Inglês Revista: Int J Cardiovasc Imaging Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Cardiovascular Research Center/BR / Hospital Encore/BR / Hospital do Servidor Público Estadual-IAMSPE/BR / Instituto Dante Pazzanese de Cardiologia/BR / University of São Paulo Medical School/BR
...