Your browser doesn't support javascript.
loading
Clinical value of intraoperative sliding CT in deep brain stimulation for Parkinson's disease / 中华神经医学杂志
Chinese Journal of Neuromedicine ; (12): 159-163, 2024.
Article em Zh | WPRIM | ID: wpr-1035974
Biblioteca responsável: WPRO
ABSTRACT
Objective:To evaluate the clinical value of intraoperative sliding CT in deep brain stimulation (DBS) for Parkinson's disease (PD).Methods:A total of 117 PD patients accepted DBS in Department of Neurosurgery, First Affiliated Hospital of Zhengzhou University from May 2019 to May 2023 were chosen; 46 patients had local anesthesia and 71 had general anesthesia. Bilateral subthalamic nucleus (STN) DBS was performed in 73 patients, bilateral medial globus pallidus (GPi) DBS was performed in 43 patients, and right GPi and left STN DBS was performed in 1 patient. Preoperative/intraoperative sliding CT images and preoperative MRI images were fused to calculate the spatial distance between the preoperative planned target and actual target (adjusting electrode position timely in case of spatial distance greater than 2 mm [electrode displacement]). Differences of spatial distance between preoperative planned target and actual target in patients accepted different types of anesthesia and surgical modalities were compared.Results:All 117 patients were successfully operated and 234 electrodes were implanted. No patients needed a second operation for misalignment of electrodes or poor efficacy. During CT scan, neither anesthesia extubation or mechanical collision nor intracranial hemorrhage complications occurred. Spatial distance between the preoperative planned target and actual target was (1.35±0.50) mm in 117 patients. Displacement was noted in 4 electrodes and immediately adjusted during the operation; and CT re-examination confirmed good electrode position. No statistical significance in spatial distance between the preoperative planned target and actual target was noted between the general anesthesia group and local anesthesia group, and between the STN group and GPi group ( P>0.05). Conclusion:Intraoperative sliding CT is simple, safe and effective, which helps to timely adjust the electrode position during operation, avoids second operation and complications, and improves the safety and efficacy of DBS.
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: Chinese Journal of Neuromedicine Ano de publicação: 2024 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: Chinese Journal of Neuromedicine Ano de publicação: 2024 Tipo de documento: Article