ABSTRACT

OBJECTIVE:

We wanted to evaluate the effect of the number of diffusion-sensitizing gradient directions on the image quality for evaluating myocardial anisotropy and fiber tracking by using in vitro diffusion tensor MR imaging (DT-MRI). MATERIALS AND

METHODS:

The DT-MR images, using a SENSE-based echoplanar imaging technique, were acquired from ten excised porcine hearts by using a 3T MR scanner. With a b-value of 800 s/mm2, the diffusion tensor images were obtained for 6, 15 and 32 diffusion-sensitizing gradient directions at the midventricular level. The number of tracked fibers, the fractional anisotropy (FA), and the length of the tracked fibers were measured for the quantitative analysis. Two radiologists assessed the image quality of the fiber tractography for the qualitative analysis.

RESULTS:

By increasing the number of diffusion-sensitizing gradient directions from 6 to 15, and then to 32, the FA and standard deviation were significantly reduced (p < 0.01), and the number of tracked fibers and the length of the tracked fibers were significantly increased (p < 0.01). The image quality of the fiber tractography was significantly increased with the increased number of diffusion-sensitizing gradient directions (p < 0.01).

CONCLUSION:

The image quality of in vitro DT-MRI is significantly improved as the number of diffusion-sensitizing gradient directions is increased.
Assuntos

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Suínos / Anisotropia / Imagem de Difusão por Ressonância Magnética / Miocárdio Tipo de estudo: Pesquisa qualitativa Limite: Animais Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2010 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Suínos / Anisotropia / Imagem de Difusão por Ressonância Magnética / Miocárdio Tipo de estudo: Pesquisa qualitativa Limite: Animais Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2010 Tipo de documento: Artigo
...