Your browser doesn't support javascript.
loading
Application of 17 Y-chromosome specific STR loci in paternity testing / 中国实验血液学杂志
Article em Zh | WPRIM | ID: wpr-267907
Biblioteca responsável: WPRO
ABSTRACT
The purpose of this study was to explore the ability of discrimination of the AmpFlSTR Yfiler PCR amplification kit containing 17 Y-STR loci and the allelic mutation in the practice of paternity testing in Chinese population. 36 non-paternity father/son pairs and 84 confirmed father/son pairs, which had been previously genotyped by using Reliagene Y-PLEX 6 commercial kit and the "9 Y-STR multiplex with reduced-size amplicons" developed by our laboratory, were subjected to Y-STR genotyping at 17 loci using the AmpFlSTR Yfiler PCR amplification kit. 17 Y-STR loci were amplified in single multiplex and the PCR products were detected by using ABI Prism 3100 DNA Sequencer. The number of Y-STR exclusion for each non-paternity father/son pair and the mutation events for each confirmed father/son pair were calculated and the observed results were compared with our previous reported data determined by Reliagene Y-PLEX 6 kit and the "9 Y-STR multiplex with reduced-size amplicons". The results showed that out of 36 non-paternity father/son pairs subjected to Y-STR genotyping by using the AmpFlSTR Yfiler kit, one case with no Y-STR exclusion of paternity and 35 cases with more than 3 Y-STR exclusions for each father/son pair were observed. The percentage of cases with more than 3 Y-STR exclusions in all the tested non-paternity cases for Yfiler kit was 97.22% (35/36), which was more than that of Reliagene Y-PLEX 6 kit (92.11%, 35/38) and our "9 Y-STR multiplex with reduced-size amplicons" (91.67%, 33/36). Except for single father/son pair with no Y-STR exclusion, an average of 11.3 Y-STR exclusions was observed in other 35 non-paternity father/son pairs. In the 84 confirmed father/son pairs, 5 mutation events with a single unit repeat change at DYS437, DYS439, DYS635, DYS389II and DYS19, respectively, were identified using the Yfiler kit. The average mutation rate was estimated at 3.50 x 10(-3) per locus per generation. The cases with Y-STR mutation events in all tested confirmed father/son pairs for Yfiler system were 5.95% (5/84), which was significantly higher than that of Y-PLEX 6 (2.15%, 2/93) and "9 Y-STR multiplex with reduced-size amplicons" (no mutation events in the same 84 confirmed father/son pairs). It is concluded that the Yfiler kit which allowing simultaneous analysis of 17 Y-STR loci offers a high ability of discrimination for paternity testing, however, the Y-STR allelic mutation of the Yfiler system can not be neglected.
Assuntos
Texto completo: 1 Base de dados: WPRIM Assunto principal: Paternidade / Repetições de Microssatélites / Cromossomos Humanos Y / Loci Gênicos / Medicina Legal / Frequência do Gene / Genética / Métodos / Mutação Limite: Humans / Male Idioma: Zh Revista: Journal of Experimental Hematology Ano de publicação: 2008 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Assunto principal: Paternidade / Repetições de Microssatélites / Cromossomos Humanos Y / Loci Gênicos / Medicina Legal / Frequência do Gene / Genética / Métodos / Mutação Limite: Humans / Male Idioma: Zh Revista: Journal of Experimental Hematology Ano de publicação: 2008 Tipo de documento: Article