Your browser doesn't support javascript.
loading
A finite element analysis of the pelvic reconstruction using fibular transplantation fixed with four different rod-screw systems after type I resection / 中华医学杂志(英文版)
Chin. med. j ; Chin. med. j;(24): 321-326, 2008.
Article em En | WPRIM | ID: wpr-287740
Biblioteca responsável: WPRO
ABSTRACT
<p><b>BACKGROUND</b>The pelvis often needs to be reconstructed after bone tumor resection. A major challenge here for the orthopedic surgeons is to choose a method that gives the best performance which depends upon its biomechanical properties. In this study, a 3-dimensional finite element analysis (FEA) was used to analyze the biomechanical properties of reconstructed pelvis using fibula transplant fixed by four commonly used rod-screw systems.</p><p><b>METHODS</b>A total pelvic finite-element model including the lumbar-sacral spine and proximal femur was constructed based on the geometry of CT image from a healthy volunteer. Three-dimensional finite element models of different implants including fibula, rod and screw were simulated using ways of solid modeling. Then various reconstructed finite element models were assembled with different finite element implant model and type I resected pelvic finite element model. The load of 500 N was imposed vertically onto the superior surface of L3 vertebral body, and the pelvis was fixed in bilateral leg standing positions. FEA was performed to account for the stress distribution on the bones and implants. The pelvis displacement of the different rod-screw fixation methods and the maximum equivalent stress (max EQV) on all nodes and element were figured out to evaluate the advantages and disadvantages of different reconstructive methods.</p><p><b>RESULTS</b>Stress concentration in the fibula transplant was extremely high in the reconstructed pelvis, but could be substantially decreased by internal fixation, which partially transferred the stress from the fibula to the rod-screw systems. High stress concentration was also found in the implants, especially in the connection sites between screw and rod. Among the four methods of fixation, a double rod system with L5-S1 pedicle and ilium screws (L5-S1 HR) produced the best performance: least stress concentrations and least total displacement.</p><p><b>CONCLUSION</b>According to the stability and stress concentration, the method of L5-S1 HR fixation combined with fibula transplantation is better than other fixation methods in pelvic reconstruction after type I resection.</p>
Assuntos
Texto completo: 1 Base de dados: WPRIM Assunto principal: Ossos Pélvicos / Cirurgia Geral / Transplante / Fenômenos Biomecânicos / Neoplasias Ósseas / Parafusos Ósseos / Procedimentos de Cirurgia Plástica / Análise de Elementos Finitos / Colo do Fêmur / Fíbula Limite: Adult / Humans / Male Idioma: En Revista: Chin. med. j Ano de publicação: 2008 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Assunto principal: Ossos Pélvicos / Cirurgia Geral / Transplante / Fenômenos Biomecânicos / Neoplasias Ósseas / Parafusos Ósseos / Procedimentos de Cirurgia Plástica / Análise de Elementos Finitos / Colo do Fêmur / Fíbula Limite: Adult / Humans / Male Idioma: En Revista: Chin. med. j Ano de publicação: 2008 Tipo de documento: Article