A comparative study on intraoperative electrocorticography with long-term intracranial EEG for localizing epileptogenic zone / 中华外科杂志
Zhonghua Wai Ke Za Zhi
; (12): 1672-1675, 2007.
Article
em Zh
| WPRIM
| ID: wpr-338092
Biblioteca responsável:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To discuss the localizing methods for epileptogenic zone with intraoperative electrocorticography (ECoG) by comparing it with long-term intracranial EEG.</p><p><b>METHODS</b>Twenty-two patients was enrolled, who received epilepsy surgeries consecutively in our institute since April 2005 to August 2006. All patients underwent intracranial electrode implantations with long-term video-EEG monitoring before the resective surgeries and the postoperative pathologies were all proved to be focal cortical dysplasia. The extra-operative and ECoG digital EEGs were statistically analyzed and compared with each other, including interictal epileptic discharge (IED) frequency, amplitude and their correlations with ictal discharge (ID).</p><p><b>RESULTS</b>In the long-term intracranial EEG, significant difference was found between IED frequency derived from ID onset verus none-onset electrodes (Z = 12.213, P < 0.001), ROC analysis showed that IED frequency is a moderately good indicator for ID, the area under the ROC curve was 0. 758 (95% CI, 0.707-0.810). There was significant difference in IED amplitude between ID and none-ID electrodes (Z = 11.765, P < 0.001). The IED frequency was significantly lower during ECoG than during long-term extra-operative monitoring (rho = 0.518, P = 0. 014). A significant positive correlation in the IED frequency pattern was found between intra-operative ECoG and extra-operative recording when the average IED frequency was over 3 spikes /min. In ECoG, the correlation of IED with ID was similar in the 'frequent' (> or = 10 spikes/min) and 'occasional' (3-10 spikes/min) groups and very different in the 'rare' (< or = C3 spikes/min) group (rho = 0.408, P = 0.147).</p><p><b>CONCLUSIONS</b>The IED from long-term EEG recording had moderate correlation in frequency and amplitude with ID position. IED frequency was usually decreased on ECoG when compared with long-term monitoring. However, ECoG could reliably reflect the IED pattern and the correlations between IED with ID in term of frequency and amplitude in the long-term EEG monitoring, when IED frequency exceeded 3 spikes/min. Under this circumstance, IED could be used for localizing the epileptogenic zone.</p>
Texto completo:
1
Base de dados:
WPRIM
Assunto principal:
Cirurgia Geral
/
Córtex Cerebral
/
Estudos Retrospectivos
/
Monitorização Intraoperatória
/
Epilepsias Parciais
/
Eletrodos Implantados
/
Eletroencefalografia
/
Métodos
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Adolescent
/
Adult
/
Child
/
Female
/
Humans
/
Male
Idioma:
Zh
Revista:
Zhonghua Wai Ke Za Zhi
Ano de publicação:
2007
Tipo de documento:
Article