Your browser doesn't support javascript.
loading
Study on Determination Methods for Dissolution of Oxytetracycline Tablets / 中国药房
China Pharmacy ; (12)2001.
Article em Zh | WPRIM | ID: wpr-533613
Biblioteca responsável: WPRO
ABSTRACT
OBJECTIVE:To establish a determination method for dissolution of oxytetracycline tablets. METHODS:The content of oxytetracycline was determined by UV spectrophotometry at detection wavelength of 271 nm. Dissolution of oxytetracycline tablets was detected by slurry process using 0.01 mol?L-1 hydrochloric solution as solvent. RESULTS:The linear range of oxytetracycline was 4~32 IU?mL-(1r=0.999 9)with an average recovery of 100.1%(RSD=0.65%). The dissolution in 45 min were all above 75%. CONCLUSION:Established method in this study can be used to determine dissolution of oxytetracycline tablets.
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: China Pharmacy Ano de publicação: 2001 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: China Pharmacy Ano de publicação: 2001 Tipo de documento: Article