Anterior Approach Preperitoneal Repair for Inguinal Hernia with Modified Kugel Mesh:A Report of 35 Cases / 中国微创外科杂志
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-589742
Biblioteca responsável: WPRO
ABSTRACT
Objective To evaluate the effects of anterior approach preperitoneal repair for inguinal hernia with modified Kugel mesh.Methods Clinical data of 35 cases receiving inguinal hernia repair with modified Kugel mesh from May 2004 to June 2006 were reviewed.The critical surgical proceduresthe hernial sac was dissected at high position,then reversed and reduced into abdominal cavity;a 10 cm?10 cm preperitoneal space was dissociated around the internal ring,into which a modified Kugel mesh was placed.The mesh was fixed to the conjoined tendon by superior tape,and to the shelving edge of inguinal ligament by inferior tape.Results The operation time was(47?10)min.No analgesic requirement in any case.The postoperative hospital stay was(6?4)days.All the wounds healed uneventfully without any seroma or infection.No recurrent case was found in the follow-up of 1-25 months(mean13.2 months)in the 35 cases.Conclusions Modified Kugel mesh used in inguinal herniorrhaphy causes less pain and swelling response to the wound,therefore it is quite suitable for repairing Ⅲ and Ⅳ type hernia.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Minimally Invasive Surgery Ano de publicação: 2005 Tipo de documento: Artigo