Your browser doesn't support javascript.
loading
Determination of cyclohexanol in urine by headspace solid-phase microextraction coupled with gas chromatography / 中华劳动卫生职业病杂志
Zhonghua laodong weisheng zhiyebing zazhi ; Zhonghua laodong weisheng zhiyebing zazhi;(12): 543-546, 2019.
Article em Zh | WPRIM | ID: wpr-805598
Biblioteca responsável: WPRO
ABSTRACT
Objective@#To establish a method for determining cyclohexanol in urine by headspace solid-phase microextraction (HS/SPME) coupled with gas chromatography (GC) .@*Methods@#After the urine sample was hydrolyzed by β-glucuronidase, 2.0 g of NaCl was added, then the analyte in urine was adsorbed by a CAR/PDMS solid phase micro-extraction head in a water bath at 50 ℃ for 20 min. And the extraction head was inserted into the gas chromatograph gasification chamber to desorb, the analyte was detected after separated by the capillary through the flame ionization detector.@*Results@#The linear range of the method was 0.1-5.0 mg/L with the correlation coefficients (r) 0.999. The average recovery was 84.5%-96.3%, the inter-day precision was 3.81%-6.00%, and the detection limit was 0.03 mg/L.@*Conclusion@#The method is founded to be low detection limit, simple operation and no need of organic solvent. So it is suitable for the detection of cyclohexanol in urine of occupational exposure to cyclohexanone.
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: Zhonghua laodong weisheng zhiyebing zazhi Ano de publicação: 2019 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Idioma: Zh Revista: Zhonghua laodong weisheng zhiyebing zazhi Ano de publicação: 2019 Tipo de documento: Article