Anatomic study of posterior atlanto-occipital-clivus screw technique / 中华骨科杂志
Chinese Journal of Orthopaedics
; (12): 165-175, 2021.
Article
em Zh
| WPRIM
| ID: wpr-884703
Biblioteca responsável:
WPRO
ABSTRACT
Objective:To investigate the anatomical safety and feasibility ofposterior occipitocervical fixation with atlan-tooccipital-clivus screw.Methods:Data of 60 patients who treated in the spinal department of our hospital with upper cervical computed tomographic scans from February 2017 to November 2019 were retrospectively collected. Occipitocervical infection, injury, tumor and deformity were excluded. The Mimics software was used to reconstruct the occiput, atlas and measure the anatomical parameters, including the height and width of the anterior edge of the clivus, the height and width of the middle part of the clivus, the thinnest distance of the soft tissue in front of the clivus, the anteroposterior diameter, transverse diameter, the angle of inside tilting in coronary plane of the occipital condyle, the distance from the hypoglossal canal to the atlantooccipital articular surface, the anteroposterior diameter and transverse diameter of the superior joint of atlas, the height of the lateral mass, and the height and transverse diameter of the inferior articular process of the superior atlas joint. The three-dimensional digital modeling was performed and the screw diameter of 3.5mm was simulated. 3-Matic software were used to measure the screw placement parameters, including the inside tilting angle in coronary plane of screw, and the angle of upper tilting in sagittal plane and length of screw. The atlanto-occipital junction was exposed at the rear of 8 cadavers. According to the above parameters, the titanium alloy screws with a diameter of 3.5 mm were transferred from the inferior articular process and posterior arch of the atlas to the clivus through the atlantooccipital. Finally, the screw path was cut along the nail path with a pendulum saw, and the track of the screw was observed to confirm the safety and effectiveness of the screw.Results:The leading edge height and width of male clivus was 16.8±2.5 mm and 20.1±3.1 mm. The middle part of the clivus was 9.7±2.3 mm and 22.4±3.7 mm. The thinnest soft tissue in front of the clivus was 5.8±1.48 mm. The anteroposterior diameter of the occipital condyle was 19.1±1.9 mm, the transverse diameter was 12.6±2.0 mm, the inside tilting angle was 33.7°±4.5°, and the vertical distance from the lowest point of the neural tube to the articular surface of the occipital condyle was 9.6±1.1 mm. The height of the lateral mass of atlas was 12.9±2.4 mm, the anteroposterior diameter of the upper joint of atlas was 21.7±1.9 mm, and the transverse diameter was 11.7±1.4 mm. The width of the inferior facet was 14.9±1.4 mm and the height of the inferior facet was 5.7±0.85 mm. The distance from the screw entry point to the vertical line of the lateral mass migration midpoint was 2.5±0.6 mm; The distance from the screw entry point to the horizontal line of the midpoint was 2.3±0.7 mm.The inside titling angle of screw was 18.4°±1.6°, the upper tilting angle was 55.6°±3.1°, the length of the screw track was 53.0±2.8 mm, the adjustment range of upper tilting angle was 15.0±2.8 mm, the adjustment range of inside tilting angle was 10.4±2.4 mm. The anatomical parameters of females were slightly smaller than those of males, and the difference was statistically significant, but there was no significant difference between left and right parameters. The screws of 8 specimens could be inserted safely and effectively.Conclusion:Atlan-tooccipital-clivus screw can be implanted without damaging the nerve and vascular structure, and it can be used as a choice for occipitocervical fixation.
Texto completo:
1
Base de dados:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Orthopaedics
Ano de publicação:
2021
Tipo de documento:
Article