Your browser doesn't support javascript.
loading
Minute Colon Perforation by a Nonabsorbable Suture Knot after Uterine Myomectomy / 이화의대지
Article em En | WPRIM | ID: wpr-939029
Biblioteca responsável: WPRO
ABSTRACT
We report a rare case of suture material-related colon perforation. A 60-year-old woman visited clinics because of the nonspecific abdominal discomfort for several months. There were no specific medical history except previous laparoscopic myomectomy 15 years ago. Colonoscopy and abdomen-pelvis computed tomography revealed an unknown foreign body penetrating the sigmoid colon wall adjacent to the uterus. We performed laparoscopic exploration with foreign body removal and primary colon wall repair. The foreign body was identified as a non-absorbable suture material suggestive of used in previous myomectomy. With recent trends for minimally invasive procedures in the field of pelvic organ surgery, surgeons, especially those without sufficient training have to pay attention to selecting the proper surgical suture materials. (Ewha Med J 2022;45(3):e7)
Texto completo: 1 Base de dados: WPRIM Tipo de estudo: Prognostic_studies Idioma: En Revista: The Ewha Medical Journal Ano de publicação: 2022 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Tipo de estudo: Prognostic_studies Idioma: En Revista: The Ewha Medical Journal Ano de publicação: 2022 Tipo de documento: Article