J Musculoskelet Neuronal Interact ; 13(1): 37-44, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23445913

RESUMO

OBJECTIVES: Methods are needed for quantifying muscle deconditioning due to immobilization, aging, or spaceflight. Electrical impedance myography (EIM) is one technique that may offer easy-to-follow metrics. Here, we evaluate the time course and character of the change in single- and multi-frequency EIM parameters in the hind-limb suspension model of muscle deconditioning in rats. METHODS: Sixty-two rats were studied with EIM during a two-week period of hind limb unloading followed by a two-week recovery period. Random subsets of animals were sacrificed at one-week time intervals to measure muscle fiber size. RESULTS: Significant alterations were observed in nearly all impedance parameters. The 50 kHz phase and multi-frequency phase-slope, created by taking the slope of a line fitted to the impedance values between 100-500 kHz, appeared most sensitive to disuse atrophy, the latter decreasing by over 33.0±6.6% (p<0.001), a change similar to the maximum reduction in muscle fiber size. Impedance alterations, however, lagged changes in muscle fiber size. CONCLUSIONS: EIM is sensitive to disuse change in the rat, albeit with a delay relative to alterations in muscle fiber size. Given the rapidity and simplicity of EIM measurements, the technique could prove useful in providing a non-invasive approach to measuring disuse change in animal models and human subjects.


Assuntos
Elevação dos Membros Posteriores/métodos , Elevação dos Membros Posteriores/fisiologia , Animais , Impedância Elétrica , Masculino , Distribuição Aleatória , Ratos , Ratos Wistar
2.
J Musculoskelet Neuronal Interact ; 13(4): 405-11, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24292610

RESUMO

OBJECTIVE: To assess the potential of electrical impedance myography (EIM) to serve as a marker of muscle fiber atrophy and secondarily as an indicator of bone deterioration by assessing the effects of spaceflight or hind limb unloading. METHODS: In the first experiment, 6 mice were flown aboard the space shuttle (STS-135) for 13 days and 8 earthbound mice served as controls. In the second experiment, 14 mice underwent hind limb unloading (HLU) for 13 days; 13 additional mice served as controls. EIM measurements were made on ex vivo gastrocnemius muscle. Quantitative microscopy and areal bone mineral density (aBMD) measurements of the hindlimb were also performed. RESULTS: Reductions in the multifrequency phase-slope parameter were observed for both the space flight and HLU cohorts compared to their respective controls. For ground control and spaceflight groups, the values were 24.7±1.3°/MHz and 14.1±1.6°/MHz, respectively (p=0.0013); for control and HLU groups, the values were 23.9±1.6°/MHz and 19.0±1.0°/MHz, respectively (p=0.014). This parameter also correlated with muscle fiber size (ρ=0.65, p=0.011) for spaceflight and hind limb aBMD (ρ=0.65, p=0.0063) for both groups. CONCLUSIONS: These data support the concept that EIM may serve as a useful tool for assessment of muscle disuse secondary to immobilization or microgravity.


Assuntos
Composição Corporal/fisiologia , Elevação dos Membros Posteriores/fisiologia , Músculo Esquelético/fisiologia , Voo Espacial , Ausência de Peso , Animais , Impedância Elétrica , Camundongos
3.
J Phys Conf Ser ; 434(1)2013.
Artigo em Inglês | MEDLINE | ID: mdl-23894248

RESUMO

Electrical impedance myography (EIM) provides a non-invasive approach for quantifying the severity of neuromuscular disease. Here we determine how well EIM data correlates to functional and ultrasound (US) measures of disease in children with Duchenne muscular dystrophy (DMD) and healthy subjects. Thirteen healthy boys, aged 2-12 years and 14 boys with DMD aged 4-12 years underwent both EIM and US measurements of deltoid, biceps, wrist flexors, quadriceps, tibialis anterior, and medial gastrocnemius. EIM measurements were performed with a custom-designed probe using a commercial multifrequency bioimpedance device. US luminosity data were quantified using a gray-scale analysis approach. Children also underwent the 6-minute walk test, timed tests and strength measurements. EIM and US data were combined across muscles. EIM 50 kHz phase was able to discriminate DMD children from healthy subjects with 98% accuracy. In the DMD patients, average EIM phase measurements also correlated well with standard functional measures. For example the 50 kHz phase correlated with the Northstar Ambulatory Assessment test (R = 0.83, p = 0.02). EIM 50 kHz phase and US correlated as well, with R = -0.79 (p < 0.001). These results show that EIM provides valuable objective measures Duchenne muscular dystrophy severity.

4.
Clin Neurophysiol Pract ; 7: 319-324, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36353647

RESUMO

Objective: To 1) explore if clinical electrophysiologists with different degrees of experience performing standard nerve conduction studies could run a threshold tracking nerve conduction study (TTNCS) protocol and 2) learn how clinical users view a research-grade TTNCSs neuronal excitability system. Methods: Five clinical electrophysiologists conducted a TTNCS session using QTracS and then completed a questionnaire describing their impressions. Results: All of the electrophysiologists completed the QTracS protocol on an initial attempt. Perceived strengths comprised the ease of preparatory steps and quick protocol speed. Identified drawbacks included an unwieldly user-interface. The electrophysiologists indicated that knowledge of TTNCS principles and applications would be critical for incorporation of the method into clinical use. Conclusions: This pilot study suggests that clinical electrophysiologists can carry out TTNCSs with a research-grade system. The development of a more user-friendly program, along with dedicated education and training, could lead to wider application of the TTNCS technique. Significance: Considered together with clinical presentation and other biomarkers, increased use of TTNCSs could provide improved assessment of neuromuscular disease and treatment response.

5.
Clin Neurophysiol ; 131(10): 2423-2428, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32828046

RESUMO

OBJECTIVES: To learn if quantitative ultrasound (QUS) distinguishes the tongues of healthy participants and amyotrophic lateral sclerosis (ALS) patients by echo intensity (EI) and to evaluate if EI correlates with measures of bulbar function. METHODS: Ultrasound was performed along the midline of the anterior tongue surface in 16 ALS patients and 16 age-matched controls using a linear hockey stick 16-7 MHz transducer. A region of interest was manually drawn and then EI was determined for the upper 1/3 of the muscle. For patients, the ALS functional rating scale - revised (ALSFRS-R) was used to calculate bulbar sub-scores and the Iowa Oral Performance Instrument (IOPI) was used to measure tongue strength. RESULTS: EI was significantly higher in ALS patients than in healthy participants (49.8 versus 37.8 arbitrary units, p < 0.01). In the patient group, EI was negatively correlated with ALSFRS-R bulbar sub-score (RS = -0.65, p < 0.01). An inverse correlation between EI and tongue strength did not reach significance (RS = -0.34, p = 0.28). CONCLUSIONS: This study suggests that EI can differentiate healthy from diseased tongue muscle, and correlates with a standard functional measure in ALS patients. SIGNIFICANCE: Tongue EI may represent a novel biomarker for bulbar dysfunction in ALS.


Assuntos
Esclerose Lateral Amiotrófica/diagnóstico por imagem , Língua/diagnóstico por imagem , Ultrassonografia , Adulto , Idoso , Biomarcadores , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
6.
Physiol Meas ; 40(5): 05NT02, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31026854

RESUMO

OBJECTIVE: The attention towards optimal signals for measuring electrical bioimpedance (EBI) has increased recently due to the many advantages they offer such as, for example, reduced measuring time. Here, the design of a three-harmonic optimized multisine input power spectrum for measuring bioimpedance is considered. APPROACH: The approach is based on designing the input power spectrum multisine excitation by optimizing a scalar function of the information matrix using the Fricke-Morse model. MAIN RESULTS: Simple analytical equations are provided that can be adopted by the reader to optimize the multisine input power spectrum to satisfy any specific application-related EBI measurement. SIGNIFICANCE: The presented signal may be a good choice of excitation signal in EBI applications where optimal excitation power spectrum is desired.


Assuntos
Espectroscopia Dielétrica , Simulação por Computador , Impedância Elétrica , Modelos Teóricos
7.
Sci Rep ; 9(1): 3145, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30816169

RESUMO

This paper provides a rigorous analysis on the measurement of the permittivity of two-dimensional anisotropic biological tissues such as skeletal muscle using the four-electrode impedance technique. The state-of-the-art technique requires individual electrodes placed at the same depth in contact with the anisotropic material, e.g. using monopolar needles. In this case, the minimum of measurements in different directions needed to estimate the complex permittivity and its anisotropy direction is 3, which translates into 12 monopolar needle insertions (i.e. 3 directions × 4 electrodes in each direction). Here, we extend our previous work and equip the reader with 8 new methods for multipolar needles, where 2 or more electrodes are spaced along the needle's shaft in contact with the tissue at different depths. Using multipolar needles, the new methods presented reduce the number of needle insertions by a factor of 2 with respect to the available methods. We illustrate the methods with numerical simulations and new experiments on ex vivo ovine skeletal muscle (n = 3). Multi-frequency longitudinal and transverse permittivity data from 30 kHz to 1 MHz is made publicly available in the supplementary material. The methods presented here for multipolar needles bring closer the application of needle electrical impedance to patients with neuromuscular diseases.


Assuntos
Anisotropia , Impedância Elétrica , Músculo Esquelético/fisiologia , Doenças Neuromusculares/terapia , Animais , Eletrodos , Campos Eletromagnéticos , Humanos , Músculo Esquelético/patologia , Agulhas , Doenças Neuromusculares/diagnóstico por imagem , Ovinos
8.
Sci Data ; 6(1): 37, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-31000708

RESUMO

A better understanding of the permittivity property of skeletal muscle is essential for the development of new diagnostic tools and approaches for neuromuscular evaluation. However, there remain important knowledge gaps in our understanding of this property in healthy and diseased skeletal muscle, which hinder its translation into clinical application. Here, we report the permittivity of gastrocnemius muscle in healthy wild type mice and murine models of spinal muscular atrophy, muscular dystrophy, diabetes, amyotrophic lateral sclerosis and in a model of myofiber hypertrophy. Data were measured ex vivo from 10 kHz to 1 MHz using the four-electrode impedance technique. Additional quantitative histology information were obtained. Ultimately, the normative data reported will offer the scientific community the opportunity to develop more accurate models for the validation and prediction of experimental observations in both pre-clinical and clinical neuromuscular disease research.


Assuntos
Esclerose Lateral Amiotrófica/fisiopatologia , Diabetes Mellitus Experimental/fisiopatologia , Músculo Esquelético/fisiologia , Atrofia Muscular Espinal/fisiopatologia , Distrofia Muscular Animal/fisiopatologia , Animais , Modelos Animais de Doenças , Capacitância Elétrica , Camundongos
9.
Physiol Meas ; 40(8): 085008, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31408853

RESUMO

OBJECTIVE: Electrical conductivity and relative permittivity are properties that indicate muscle health and they have different values parallel and perpendicular to the direction of the myofiber, a concept known as anisotropy. When the intrinsic electrical properties of muscle have ratios of anisotropy that are different then there is no analytical solution that can describe the electrical potential distribution in the tissue. APPROACH: Here, we present approximate analytical solutions to monodomain equations with unequal anisotropy ratios. For this, we base our analysis on perturbation theory where the electrical potential is approximated by the sum of the zeroth- and first-order terms of an infinite series. MAIN RESULTS: The validity of the approach is confirmed using experimental data for healthy and diseased muscle available online. SIGNIFICANCE: A better understanding of electrical potential distribution in anisotropic skeletal muscle tissue will allow the development of improved diagnostic tools for neuromuscular diseases.


Assuntos
Condutividade Elétrica , Fenômenos Eletrofisiológicos , Modelos Biológicos , Anisotropia , Músculo Esquelético/fisiologia
10.
Physiol Meas ; 39(5): 055005, 2018 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-29616985

RESUMO

OBJECTIVE: Needle EMG remains the standard clinical test for neuromuscular disease (NMD) assessment, but it only characterizes myofiber membrane depolarization. On the other hand, electrical impedance provides non-electrically active structural and compositional data of tissues. Here, we designed a prototype of needle electrode integrating electrical impedance and EMG measurement capabilities, the so-called I-EMG needle electrode. APPROACH: We use finite element method models to study the impedance recording characteristics of I-EMG needle electrodes. The simulated electrical and mechanical design specifications are then manufactured to create a prototype of an I-EMG needle electrode. We pilot these new needle electrodes by conducting in vivo impedance measurements with muscle at rest on healthy wild-type (wt, n = 5) and muscular dystrophy (mdx, n = 5) mice. Comparisons between wt and mdx mice are performed using Mann-Whitney test, two-tailed, p < 0.05. The electrical characterization of the EMG electrode in the developed I-EMG needles was performed in vitro on saline solution and through EMG detection in wt animal at rest and during voluntary contractions. RESULTS: Muscle impedance demonstrate good repeatability (p < 0.05 and p < 0.005 for resistance and reactance at 50 kHz, respectively) and agreement between different I-EMG needles. Impedance data allows us to discriminate between mdx and wt muscle (p < 0.05 and p < 0.005 for resistance and reactance at 10 kHz, respectively). EMG broadband noise power and peak amplitude using the I-EMG needle were similar to that of a commercial monopolar EMG needle. EMG recordings using the I-EMG needle measured electrical activity similar to a standard monopolar needle with muscle at rest and during voluntary contraction. SIGNIFICANCE: Needle I-EMG technology may offer the opportunity to enhance the diagnostic capability and quantification of NMD beyond that possible with either impedance or EMG techniques separately. Ultimately, needle I-EMG could serve as a new bedside tool to assess NMD without increasing the complexity or duration of the EMG test.


Assuntos
Eletromiografia/instrumentação , Agulhas , Animais , Impedância Elétrica , Eletrodos , Análise de Elementos Finitos , Camundongos , Músculos/fisiologia , Músculos/fisiopatologia , Distrofias Musculares/fisiopatologia
11.
Clin Neurophysiol ; 118(11): 2393-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17889597

RESUMO

OBJECTIVE: To determine the impact of skin-subcutaneous fat layer thickness on electrical impedance myography (EIM) measurements. METHODS: Linear 50 kHz EIM was performed on quadriceps of 62 healthy subjects (mean age 52.2+/-20.6 years) with a wide variety of skin-subcutaneous fat layer (SFL) thicknesses, as measured by ultrasound. Correlations were sought between the main EIM outcome parameter phase (theta) and SFL thickness. A multiple regression analysis was also performed for theta with SFL thickness and age as independent variables. RESULTS: Mean skin-fat thickness was significantly different (p<0.01) between men (0.76+/-0.23 cm) and women (1.43+/-0.51 cm). Neither linear nor quadratic fits produced significant correlations between theta and SFL thickness. A significant but weak positive correlation (r(2)=0.14, p<0.05) was seen between age and SFL thickness in women, but not in men. A strong negative correlation between age and theta was observed for both men (r(2)=0.48, p<0.01) and women (r(2)=0.68, p<0.01). In multiple regression analysis, age but not SFL thickness was found to have a significant association with theta. CONCLUSIONS: SFL thickness does not contribute substantially to the phase measured by linear-EIM. SIGNIFICANCE: EIM data can be interpreted confidently in individuals with varying SFL thickness.


Assuntos
Tecido Adiposo/anatomia & histologia , Impedância Elétrica , Dobras Cutâneas , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Estimulação Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miografia/métodos , Análise de Regressão , Fatores Sexuais , Pele , Ultrassonografia/métodos
12.
Physiol Meas ; 38(9): 1748-1765, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28721951

RESUMO

OBJECTIVE: Neurologists and physiatrists need improved tools for the evaluation of skeletal muscle condition. Here we evaluate needle electrical impedance myography (EIM), a new minimally invasive approach to determine muscle status that could ultimately become a bedside tool for the assessment of neuromuscular disorders. APPROACH: We design and study the recording characteristics of tetrapolar EIM needle electrodes combining theory and finite-element model simulations. We then use these results to build and pilot in vivo an EIM needle electrode in the rat gastrocnemius muscle ([Formula: see text]). The dielectric properties of muscle are reported (mean ± standard deviation). RESULTS: The numerical simulations show that the contribution of subcutaneous fat and muscle tissues to needle EIM data is <3% and >97%, respectively, and the sensed volume is [Formula: see text] cm3. Apparent resistivity [Formula: see text] [Formula: see text] cm and relative permittivity [Formula: see text] (dimensionless) measured at 10 kHz are in good agreement with in vivo dielectric properties reported in the literature. SIGNIFICANCE: The results presented show the feasibility of measuring muscle impedivity in vivo using a needle electrode from 10 kHz to 1 MHz. The development of needle EIM technology can open up a new field of study in electrodiagnostic medicine, with potential applications to both disease diagnosis and biomarker assessment of therapy.


Assuntos
Miografia/instrumentação , Agulhas , Animais , Impedância Elétrica , Eletrodos , Análise de Elementos Finitos , Masculino , Ratos , Ratos Wistar
13.
Phys Med Biol ; 62(22): 8616-8633, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28905814

RESUMO

The capability of measuring the complex permittivity of tissues has the potential to provide valuable new insights to inform medical assessment and diagnosis. However, existing electrical impedance approaches have practical limitations when aiming to measure tissues' anisotropy with accuracy. Here we present new methods that overcome the limitations of previous approaches by modeling the anisotropy in both the resistivity and reactivity of tissues measured in three or more different directions. These new methods are validated with numerical simulations and in situ experiments on healthy ovine skeletal muscle. The obtained data between 3 kHz and 1 MHz are also made publicly available in the supplementary information.


Assuntos
Impedância Elétrica , Modelos Biológicos , Músculo Esquelético/fisiologia , Animais , Anisotropia , Músculo Esquelético/citologia , Ovinos
14.
Physiol Meas ; 36(11): 2353-67, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26489699

RESUMO

This paper presents a step forward towards the analysis of a linear periodically time-varying (PTV) bioimpedance ZPTV(jw, t), which is an important subclass of a linear time-varying (LTV) bioimpedance. Similarly to the Fourier coefficients of a periodic signal, a PTV impedance can be decomposed into frequency dependent impedance phasors, [Formula: see text], that are rotating with an angular speed of wr = 2πr/TZ. The vector length of these impedance phasors corresponds to the amplitude of the rth-order harmonic impedance |Zr( jw)| and the initial phase is given by Φr(w, t0) = [Symbol: see text]Zr( jw) + 2πrt0/TZ, with t0∈[0, T] being a time instant within the measurement time T. The impedance period TZ stands for the cycle length of the bio-system under investigation; for example, the elapsed time between two consecutive R-waves in the electrocardiogram or the breathing periodicity in case of the heart or lungs, respectively. First, it is demonstrated that the harmonic impedance phasor [Formula: see text], at a particular measured frequency k, can be represented by a rotating phasor, leading to the so-called circular motion analysis technique. Next, the two dimensional (2D) representation of the harmonic impedance phasors is then extended to a three-dimensional (3D) coordinate system by taking into account the frequency dependence. Finally, we introduce a new visualizing tool to summarize the frequency response behavior of ZPTV( jw, t) into a single 3D plot using the local Frenet-Serret frame. This novel 3D impedance representation is then compared with the 3D Nyquist representation of a PTV impedance. The concepts are illustrated through real measurements conducted on a PTV RC-circuit.


Assuntos
Espectroscopia Dielétrica/métodos , Movimento , Espectroscopia Dielétrica/instrumentação , Eletrodos , Imagens de Fantasmas , Fatores de Tempo
15.
Arch Neurol ; 54(7): 907-8, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9236581

RESUMO

OBJECTIVES: To describe a patient who developed an unusual polyneuropathy after treatment with interferon alfa-2a for hepatitis C and to discuss issues related to diagnosis and pathogenesis. DESIGN: Case report. SETTING: Tertiary care center. CASE: A 46-year-old man with chronic hepatitis C had acute onset of an axonal polyneuropathy with prominent small-fiber involvement shortly after completing a standard 6-month course of therapy with low-dose interferon alfa-2a. MAIN OUTCOME AND RESULTS: Further interferon treatment for hepatitis C was discontinued. CONCLUSION: Standard, low-dose interferon alfa-2a treatment can produce a persistent predominantly small-fiber polyneuropathy.


Assuntos
Interferon-alfa/efeitos adversos , Doença dos Neurônios Motores/induzido quimicamente , Axônios/efeitos dos fármacos , Eletrofisiologia , Hepatite C/tratamento farmacológico , Humanos , Interferon alfa-2 , Interferon-alfa/administração & dosagem , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes , Pele/efeitos dos fármacos , Pele/fisiopatologia
16.
Neurology ; 47(1): 269-72, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8710094

RESUMO

There have been few reports of complications related to electromyography. Needle examination of certain muscles is sometimes avoided in patients taking anticoagulant agents, although no clear guidelines have been established. We describe a patient who was not receiving an anticoagulant and developed a large paraspinal muscle hematoma after routine electromyography. Subsequently, all patients who underwent paraspinal muscle electromyography and were diagnosed with radiculopathy at our institution over a 14-month period were reviewed. From this group, 17 patients were identified who had also underwent MRI of the appropriate spinal levels within 1 week after the needle examination. These images were reviewed for evidence of paraspinal muscle hematomas. Four small hematomas were identified in four different patients. None of these were radiologically significant compared with the large hematoma described in the case report. Radiologically apparent paraspinal hematomas after electromyography are an unusual complication of needle examination and do not appear to have any clinical significance. Nevertheless, the presence of these lesions justifies caution when considering electromyography of paraspinal and other deeper muscles in anticoagulated patients.


Assuntos
Hematoma/fisiopatologia , Músculos/inervação , Medula Espinal/irrigação sanguínea , Adulto , Eletromiografia , Humanos , Músculos/irrigação sanguínea
17.
Neurology ; 58(7): 1081-7, 2002 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-11940697

RESUMO

BACKGROUND: Inclusion body myositis (IBM) remains without effective therapy. As anabolic steroids have myotrophic properties, the authors studied whether a synthetic androgen, oxandrolone, would have efficacy in IBM. METHODS: A double-blind, placebo-controlled, crossover design was used. Patients received oxandrolone or placebo for 12 weeks followed by a minimum 2-month washout period, followed by 12 weeks of the alternative treatment. Maximal voluntary isometric contraction testing (MVICT), manual muscle testing (MMT), and functional performance testing were obtained before and after each treatment period, with the whole-body MVICT score as the primary outcome measure. RESULTS: Of 19 patients enrolled, 16 (14 men, 2 women; median age 68.5 years) had complete data for at least the first treatment period, with 13 completing the entire study. Whole-body MVICT improved by a median of 15.5 kg with drug and 4.1 kg with placebo (p = 0.06), whereas MMT demonstrated a median increase of 2.0 Medical Research Council points with drug and 0.9 point with placebo (p = 0.33). Upper-extremity MVICT demonstrated a significant treatment effect, with strength increasing a median 6.3 kg with drug vs 2.5 kg with placebo (p = 0.006). Stair climbing also increased a median of 1 step on average with drug versus no change with placebo (p < 0.001). Minimal adverse effects occurred. CONCLUSIONS: Oxandrolone had a borderline significant effect in improving whole-body strength and a significant effect in improving upper-extremity strength as measured by MVICT. Given these findings, further study of this drug, possibly in combination with an immunomodulating agent, is warranted.


Assuntos
Anabolizantes/uso terapêutico , Miosite de Corpos de Inclusão/tratamento farmacológico , Oxandrolona/uso terapêutico , Idoso , Anabolizantes/efeitos adversos , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Contração Isométrica/efeitos dos fármacos , Masculino , Oxandrolona/efeitos adversos , Projetos Piloto , Estatísticas não Paramétricas
18.
Clin Neurophysiol ; 112(2): 280-5, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11165530

RESUMO

OBJECTIVES: To study the effects of elbow heating on conduction block (CB) and across-elbow conduction velocity (CV) in patients with ulnar neuropathy at the elbow (UNE). METHODS: We studied 15 patients with UNE, performing motor nerve conduction studies at 32 degrees C and after heating the elbow to 42 degrees C. RESULTS: At 32 degrees C, mean response amplitude and area with above-elbow (AE) stimulation were 20.4 and 16.0% lower than with below-elbow (BE) stimulation, respectively. With heating the elbow to 42 degrees C, these differences increased significantly to 28.9 and 26.9% (P=0.019 and 0.029), respectively. The mean CV reduction in the across-elbow segment relative to the forearm segment also increased from 20.5 m/s at 32 degrees C to 25.6 m/s at 42 degrees C (P=0.0010). Across-elbow CV at 32 degrees C correlated with increased CB (as measured by amplitude) with heating (r=0.53, P=0.048) and approached significance for area (r=0.48, P=0.068) Likewise, baseline CB at 32 degrees C correlated with the likelihood of increased CB for amplitude (r=0.77, P<0.001), and approached significance for area (r=0.47, P=0.079). CONCLUSIONS: Elbow heating in UNE increases the relative drop in across-elbow CV and the degree of across-elbow CB; absolute across-elbow CV and the presence of baseline CB at 32 degrees C are good predictors of this latter effect.


Assuntos
Cotovelo/inervação , Temperatura Alta , Condução Nervosa , Nervo Ulnar/fisiopatologia , Neuropatias Ulnares/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação
19.
Phys Med Biol ; 59(10): 2369-80, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24743385

RESUMO

Slow-twitch (type 1) skeletal muscle fibers have markedly greater mitochondrial content than fast-twitch (type 2) fibers. Accordingly, we sought to determine whether the dielectric properties of these two fiber types differed, consistent with their distinct intracellular morphologies. The longitudinal and transverse dielectric spectrum of the ex vivo rat soleus (a predominantly type 1 muscle) and the superficial layers of rat gastrocnemius (predominantly type 2) (n = 15) were measured in the 1 kHz-10 MHz frequency range and modeled to a resistivity Cole-Cole function. Major differences were especially apparent in the dielectric spectrum in the 1 to 10 MHz range. Specifically, the gastrocnemius demonstrated a well-defined, higher center frequency than the soleus muscle, whereas the soleus muscle showed a greater difference in the modeled zero and infinite resistivities than the gastrocnemius. These findings are consistent with the fact that soleus tissue has larger and more numerous mitochondria than gastrocnemius. Evaluation of tissue at high frequency could provide a novel approach for assessing intracellular structure in health and disease.


Assuntos
Espectroscopia Dielétrica , Espaço Intracelular , Fibras Musculares de Contração Rápida/citologia , Fibras Musculares de Contração Lenta/citologia , Animais , Calibragem , Masculino , Tamanho Mitocondrial , Ratos , Ratos Wistar
20.
Physiol Meas ; 34(2): 203-21, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23353926

RESUMO

Multifrequency electrical impedance myography (MFEIM) in the 3-300 kHz range was applied to 68 subjects representing 19 different neuromuscular diseases, and the impedances analyzed using the 5-element circuit model. Depending on severity, the 'cellular' parameters r(2), r(3), 1/c(1) and 1/c(2) were found to be as much as 10- to 20-fold larger than for normal subjects (taking age and girth into account), but in almost every case the extracellular fluid parameter r(1) was at most only marginally affected. Strong correlations are found between r(2) and 1/c(1,) but in the case of ALS that breaks down when c(1) (representing the muscle fiber membrane capacitance) falls below half the normal value. Also, c(2) (tentatively associated with intracellular organelle membranes) was found to be the most sensitive to disease progress in ALS, about three times more so than the 50 kHz phase, already suggested for use in clinical drug testing. We conclude that following parameters obtained using the combined MFEIM/5-element circuit analysis scheme offer a reliable, non-invasive and objective way of characterizing muscle in neuromuscular disease or during clinical drug testing.


Assuntos
Condutometria/métodos , Diagnóstico por Computador/métodos , Modelos Neurológicos , Músculo Esquelético/fisiopatologia , Doenças Neuromusculares/diagnóstico , Doenças Neuromusculares/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA