Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Rev Esp Cir Ortop Traumatol ; 68(3): T181-T189, 2024.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38232935

RESUMEN

INTRODUCTION: The treatment of rhizarthrosis using trapeziometacarpal prostheses (TMP) is increasing. Complications may lead to loss of the implant and result in salvage surgery. Our aim was to assess major complications with the use of some TMP models and their rescue. MATERIAL AND METHOD: Retrospective study on TMP implanted between 2006 and 2021. Models studied: Arpe®, Elektra®, Ivory®, Maïa®, Isis® and Touch®. Demographic data were assessed, implant placement by radiographic study, technical data, complications, salvage surgeries and final survival. RESULTS: Review of 224 TMP, 45 Arpe® (95.5% survival, rate follow-up [R] 6-16 years), 5 Elektra® (80% survival, R 13-14), 14 Ivory® (92.8% survival, R 9-11), 7 Maïa® (100% survival, R 8-9), 115 Isis® (99.1% survival, R 1-8), 38 Touch® (100% survival, R 1-4). The medial angle of the dome with the proximal articular surface of the trapezium in the lateral plane, was: Arpe®: 8.85°, Elektra®: not assessable, Ivory®: 6.6°, Maïa®: 14.4°, Isis®: 3.8°, and Touch®: 5.95°. The Isis® was placed 100% with scopic guidance presenting a significantly lower angle respect to the medial angle of the dome with the proximal articular surface of the trapezium. As main complications, we observed 3.5% of dislocations and 4% of mobilisations, with the Elektra® being responsible for 47% of these. Nineteen salvage surgeries were performed, with 3% of the implants being lost. CONCLUSIONS: Dislocation and mobilisation are the most observed complications, the Elektra® responsible for almost half of them. Correct placement and implant design appear to be crucial to avoid them in the short and long term.

2.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37918688

RESUMEN

INTRODUCTION: The treatment of rhizarthrosis using trapeziometacarpal prostheses (TMP) is increasing. Complications may lead to loss of the implant and result in salvage surgery. Our aim was to assess major complications with the use of some TMP models and their rescue. MATERIAL AND METHOD: Retrospective study on TMP implanted between 2006 and 2021. Models studied: Arpe®, Elektra®, Ivory®, Maïa®, Isis® and Touch®. Demographic data were assessed, implant placement by radiographic study, technical data, complications, salvage surgeries and final survival. RESULTS: Review of 224 TMP, 45 Arpe® (95.5% survival, rate follow-up [R] 6-16 years), 5 Elektra® (80% survival, R 13-14), 14 Ivory® (92.8% survival, R 9-11), 7 Maïa® (100% survival, R 8-9), 115 Isis® (99.1% survival, R 1-8), 38 Touch® (100% survival, R 1-4). The medial angle of the dome with the proximal articular surface of the trapezium in the lateral plane, was: Arpe®: 8.85°, Elektra®: not assessable, Ivory®: 6.6°, Maïa®: 14.4°, Isis®: 3.8°, and Touch®: 5.95°. The Isis® was placed 100% with scopic guidance presenting a significantly lower angle respect to the medial angle of the dome with the proximal articular surface of the trapezium. As main complications, we observed 3.5% of dislocations and 4% of mobilisations, with the Elektra® being responsible for 47% of these. Nineteen salvage surgeries were performed, with 3% of the implants being lost. CONCLUSIONS: Dislocation and mobilisation are the most observed complications, the Elektra® responsible for almost half of them. Correct placement and implant design appear to be crucial to avoid them in the short and long term.

3.
Artículo en Inglés, Español | MEDLINE | ID: mdl-34148810

RESUMEN

INTRODUCTION: The treatment of trapeziometacarpal osteoarthritis through the implantation of total trapeziometacarpal prostheses is in continuous expansion. The Isis® prosthesis is a trunk-conical threaded anchorage prosthesis. Our objective was to assess the functional results and survival of this implant for at least one year of follow-up. MATERIAL AND METHOD: Prospective study on 53 Isis® prosthesis, implanted from april 2014 to january 2019. The Van Cappelle functional test, pain, strength, mobility, return to previous activity, radiological variables and placement of the trapezial component were evaluated. The surgical technique was performed with a guide wirefocused on the trapezius and control of the scopia. Observed complications were recorded and statistical analysis was performed. RESULTS: Fifty-one implants (49 patients) were reviewed. Mean follow-up was 2.1 years (1-5.7). Van Cappelle's test, pain, mobility, and grip and clamp strength improved significantly, as did the distance between the metacarpal head and the trapezius base; 96% of the patients returned in less than 6 months to their activities. Minor complications, 3 De Quervain's tendinopathy and 2 intra-operative metacarpal and 2 trapezium fractures were recorded, and one carpal tunnel syndrome. There was no dislocation, mobilization, or implant infection. CONCLUSIONS: The functional results of the Isis® prosthesis are excellent in the short term, far exceeding the first year of 100% of survival. The complications that arose were minor and few. The anchorage and placement of the trapezial component guided by scopia seem to be crucial for the good result.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda