Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39252591

RESUMEN

BACKGROUND: Hemodynamic impact of commissural alignment (CA) with self-expandable transcatheter aortic valves (TAVR) has not been investigated yet. AIMS: To determine hemodynamic impact of CA with self-expandable TAVR. METHODS: Multicentric ambispective study comparing patients who underwent self-expandable TAVR in seven centers with the Evolut Pro/Pro+ (EP) (Medtronic) and Acurate neo2 (AN2) (Boston Scientific) with and without CA strategies. The degree of commissural misalignment (CMA) was assessed by computed tomography/angiography and 1-year transvalvular gradients/regurgitation evaluated by echocardiography. A matched comparison according to annular dimensions/eccentricity, prosthesis size/type, and baseline left ventricular function and gradients was performed. RESULTS: A total of 557 patients, mean age 80.7 ± 6.6 years, 61.4% men, and STS score of 4.3 ± 3.1% were analyzed. A CA technique was attempted in 215 patients (38.6%), including 113 patients with AN2 and 102 patients with EP. None/mild CMA was found in 158 (73.5% vs. 43.6% if no CA attempted, p < 0.001) with no differences between devices (AN2:75.2%; EP:71.6%, p = 0.545). Patients with moderate/severe CMA had a greater aortic peak gradient (22.3 ± 8.7 vs. 19.7 ± 8.5, p = 0.001), significantly greater progression of both peak (p = 0.002) and mean gradients (p = 0.001) after matching, and higher rate of central aortic regurgitation (1.2% vs. 0.4%, p = 0.005) at 1-year, but not a greater proportion of patients with mean gradient ≥ 10 mmHg. CONCLUSIONS: The use of CA strategies significantly reduced the rate of CMA for the self-expandable TAVR devices ACN2 and EP which was associated to lower transvalvular gradients and intra-prosthetic regurgitation progression at 1-year although no criteria of structural deterioration were met at this follow up. CLINICALTRIALS: org: NCT05097183.

2.
Heart Vessels ; 39(3): 216-225, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37872307

RESUMEN

Soluble ST2 (sST2) is the expression of a pathogenic process related to adverse remodeling that ultimately leads to increased mortality in heart failure (HF). Risk score models provide a comprehensive approach for mortality prediction, beyond the use of biomarkers alone. The objective was to determine the additional value of sST2 and two well-validated contemporary risk scores, BCN-Bio-HF and MAGGIC-HF, in predicting mortality and readmission in the acute setting. This prospective study included 129 patients (mean age 75 ± 9 years; 52% males) after an urgent HF visit. Baseline sST2 levels were measured and the two risk scores were calculated. The primary endpoint was all-cause mortality, and the secondary endpoint was HF readmissions. The follow-up period was 3.6 ± 1.9 years. Patients who died (46%) had higher sST2 concentrations (80.5 vs. 42.7 ng/ml; p < 0.001). The BCN-Bio-HF calculator with sST2 demonstrated the best discriminative ability for mortality prediction (area under the ROC curve: 0.792; p < 0.001). In multivariate analysis for each risk score, the MAGGIC-HF score retained its predictive value only in the model without sST2 (3-year risk: HR = 1.036; 95% CI 1.019-1.054; p < 0.001). However, the BCN-Bio-HF score maintained its prognostic value with sST2 (HR = 1.032; 95%CI 1.020-1.044; p < 0.001), as well as without sST2 (HR = 1.035; 95% CI 1.021-1.049; p < 0.001). sST2 was not associated with readmission, and only the BCN-Bio-HF risk of HF hospitalization showed independent predictive value (OR = 1.040; 95% CI 1.005-1.076; p = 0.023). For predicting long-term mortality in HF in the emergency department, the BCN-Bio-HF calculator with sST2 demonstrated superior discrimination and allows estimation of the risk of HF hospitalizations.


Asunto(s)
Insuficiencia Cardíaca , Proteína 1 Similar al Receptor de Interleucina-1 , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Estudios Prospectivos , Péptido Natriurético Encefálico , Pronóstico , Biomarcadores/metabolismo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
3.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34390296

RESUMEN

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
4.
Biophys J ; 118(3): 708-719, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-31952802

RESUMEN

Blotting has been the standard technique for preparing aqueous samples for single-particle electron cryo-microscopy for over three decades. This technique removes the excess solution from a transmission electron microscope grid by pressing absorbent filter paper against the specimen before vitrification. However, this standard technique produces vitreous ice with inconsistent thickness from specimen to specimen and from region to region within the same specimen, the reasons for which are not understood. Here, high-speed interference contrast microscopy is used to demonstrate that the irregular pattern of fibers in the filter paper imposes tortuous, highly variable boundaries during the removal of excess liquid from a flat, hydrophilic surface. As a result, aqueous films of nonuniform thickness are formed while the filter paper is pressed against the substrate. This pattern of nonuniform liquid thickness changes again after the filter paper is pulled away, but the thickness still does not become completely uniform. We suggest that similar topographical features of the liquid film are produced during the standard technique used to blot EM grids and that these manifest in nonuniform ice after vitrification. These observations suggest that alternative thinning techniques, which do not rely on direct contact between the filter paper and the grid, may result in more repeatable and uniform sample thicknesses.


Asunto(s)
Vitrificación , Agua , Microscopía por Crioelectrón
5.
Molecules ; 25(21)2020 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-33121022

RESUMEN

Photodynamic diagnosis (PDD) and therapy (PDT) are emerging, non/minimally invasive techniques for cancer diagnosis and treatment. Both techniques require a photosensitizer and light to visualize or destroy cancer cells. However, a limitation of conventional, non-targeted PDT is poor selectivity, causing side effects. The bioconjugation of a photosensitizer to a tumor-targeting molecule, such as an antibody or a ligand peptide, is a way to improve selectivity. The bioconjugation strategy can generate a tumor-targeting photosensitizer conjugate specific for cancer cells, or ideally, for multiple tumor compartments to improve selectivity and efficacy, such as cancer stem cells and tumor neovasculature within the tumor microenvironment. If successful, such targeted photosensitizer conjugates can also be used for specific visualization and detection of cancer cells and/or tumor angiogenesis (an early event in tumorigenesis) with the hope of an early diagnosis of cancer. The purpose of this review is to summarize some current promising target molecules, e.g., tissue factor (also known as CD142), and the currently used bioconjugation strategies in PDT and PDD, with a focus on newly developed protein photosensitizers. These are genetically engineered photosensitizers, with the possibility of generating a fusion protein photosensitizer by recombinant DNA technology for both PDT and PDD without the need of chemical conjugation. We believe that providing an overview of promising targets and bioconjugation strategies will aid in driving research in this field forward towards more effective, less toxic, and non- or minimally invasive treatment and diagnosis options for cancer patients.


Asunto(s)
Terapia Molecular Dirigida/métodos , Neoplasias/diagnóstico , Neoplasias/tratamiento farmacológico , Fotoquimioterapia/métodos , Humanos , Neoplasias/patología
6.
Euro Surveill ; 23(14)2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29637890

RESUMEN

In Andalusia, Spain, West Nile virus (WNV) surveillance takes place from April to November, during the active vector period. Within this area seroconversion to this virus was evidenced in wild birds in 2004, affecting horses and two humans for the first time in 2010. Since 2010, the virus has been isolated every year in horses, and national and regional surveillance plans have been updated with the epidemiological changes found. WNV is spreading rapidly throughout southern Europe and has caused outbreaks in humans. Here we describe the second WNV outbreak in humans in Andalusia, with three confirmed cases, which occurred between August and September 2016, and the measures carried out to control it. Surveillance during the transmission season is essential to monitor and ensure prompt identification of any outbreaks.


Asunto(s)
Culex/virología , Brotes de Enfermedades , Insectos Vectores/virología , Vigilancia de la Población/métodos , Fiebre del Nilo Occidental/epidemiología , Fiebre del Nilo Occidental/transmisión , Virus del Nilo Occidental/aislamiento & purificación , Anciano , Animales , Anticuerpos Antivirales/sangre , Aves/virología , Brotes de Enfermedades/veterinaria , Ensayo de Inmunoadsorción Enzimática/veterinaria , Femenino , Enfermedades de los Caballos/epidemiología , Enfermedades de los Caballos/virología , Caballos/virología , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Mosquitos Vectores , España/epidemiología , Fiebre del Nilo Occidental/veterinaria , Fiebre del Nilo Occidental/virología , Virus del Nilo Occidental/genética , Virus del Nilo Occidental/inmunología
7.
Dig Endosc ; 26(6): 731-6, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24645966

RESUMEN

BACKGROUND AND AIM: To compare the efficacy and tolerability of a low-volume (2-L) polyethylene glycol (PEG) regimen for colonoscopy compared to single (4-L) or split-dose (2-L + 2-L) regimens. METHODS: In-hospital patients who were candidates for colonoscopy were randomly assigned to: group 1 single-dose (PEG 4 L the day before the study, n = 60); group 2: split-dose (2 L the day before and 2 L on the day of the procedure, n = 61); and group 3: low-volume 2-L PEG solution (the day of the procedure, n = 59). A blinded evaluation of the quality of colonic preparation was assessed by the Boston bowel preparation scale. RESULTS: Satisfactory bowel preparation of the right colon was more frequently reported for group 3 than for group 1 (70% vs 53%, P = 0.045), in the transverse colon it was 82% versus 69% (P = 0.032), and on the left side of the colon it was 80% versus 67.7% (P = 0.028). Compared to group 2, satisfactory bowel preparation in group 3 was similar in the transverse colon and left colon. Nausea, vomiting, and abdominal discomfort were less frequent in patients of group 3. Patients in group 3 had fewer sleep disorders and fewer hours of sleep loss compared to patients in the other groups. CONCLUSIONS: Preparation with 2 L caused less abdominal discomfort and fewer sleep disorders. The split dose had a better quality of preparation in the right colon. Both preparations were clearly better than the 4-L preparation.


Asunto(s)
Catárticos/administración & dosificación , Colonoscopía , Polietilenglicoles/administración & dosificación , Irrigación Terapéutica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
8.
Can J Ophthalmol ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39095036

RESUMEN

Social determinants of health (SDH) play a crucial role in shaping health outcomes. Few studies have explored the impact of SDH in ocular oncology, looking at differences in disease presentation, treatment choices, and outcomes based on race, ethnicity, socioeconomic status (SES), and insurance status. Retinoblastoma exhibits disparities in survival, with lower-income countries experiencing substantially lower rates compared to high-income countries. In the U.S., racial and SES disparities exist, impacting treatment choices and outcomes in children with retinoblastoma. Disparities in treatment modalities based on race and SES have been reported in uveal melanoma, with non-White and economically disadvantaged patients more likely to undergo primary enucleation. Ocular surface squamous neoplasia (OSSN) exhibits racial and socioeconomic disparities in treatment outcomes. Black patients with OSSN face higher mortality, independent of tumor size, eye laterality, or tumor behavior. Given the rarity, there is no data on disparities in vitreoretinal lymphoma management. When using primary central nervous system lymphoma as a surrogate, management and survival outcomes vary based on factors such as race, socioeconomic status, and insurance status. This article aims to review current literature on disparities in ocular oncology, highlighting the need for granular data to better understand existing gaps in care within ocular oncology.

9.
BMJ Open ; 14(3): e074252, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553060

RESUMEN

INTRODUCTION: The European Environment Agency estimates that 75% of the European population lives in cities. Despite the many advantages of city life, the risks and challenges to health arising from urbanisation need to be addressed in order to tackle the growing burden of disease and health inequalities in cities. This study, Urban environment and health: a cross-sectional multiregional project based on population health surveys in Spain (DAS-EP project), aims to investigate the complex association between the urban environmental exposures (UrbEEs) and health. METHODS AND ANALYSIS: DAS-EP is a Spanish multiregional cross-sectional project that combines population health surveys (PHS) and geographical information systems (GIS) allowing to collect rich individual-level data from 17 000 adult citizens participating in the PHS conducted in the autonomous regions of the Basque Country, Andalusia, and the Valencian Community, and the city of Barcelona in the years 2021-2023. This study focuses on the population living in cities or metropolitan areas with more than 100 000 inhabitants. UrbEEs are described by objective estimates at participants' home addresses by GIS, and subjective indicators present in PHS. The health outcomes included in the PHS and selected for this study are self-perceived health (general and mental), prevalence of chronic mental disorders, health-related quality of life, consumption of medication for common mental disorders and sleep quality. We aim to further understand the direct and indirect effects between UrbEEs and health, as well as to estimate the impact at the population level, taking respondents' sociodemographic and socioeconomic characteristics, and lifestyle into consideration. ETHICS AND DISSEMINATION: The study was approved by the regional Research Ethics Committee of the Basque Country (Ethics Committee for Research Involving Medicinal Products in the Basque Country; PI2022138), Andalusia (Biomedical Research Ethics Committee of the Province of Granada; 2078-N-22), Barcelona (CEIC-PSMar; 2022/10667) and the Valencian Community (Ethics Committee for Clinical Research of the Directorate General of Public Health and Center for Advanced Research in Public Health; 20221125/04). The results will be communicated to the general population, health professionals, and institutions through conferences, reports and scientific articles.


Asunto(s)
Salud Poblacional , Calidad de Vida , Adulto , Humanos , España/epidemiología , Estudios Transversales , Encuestas y Cuestionarios
10.
Microorganisms ; 12(3)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38543658

RESUMEN

Approximately a quarter of patients with infective endocarditis (IE) who have surgical indication only receive antibiotic treatment. Their short-term prognosis is dismal. We aimed to describe the characteristics of this group of patients to evaluate the mortality according to the cause of rejection and type of surgical indication and to analyze their prognostic factors of mortality. From 2005 to 2022, 1105 patients with definite left-sided IE were consecutively attended in three tertiary hospitals. Of them, 912 (82.5%) had formal surgical indication according to the most recent European Guidelines available in each period of the study and 303 (33%) only received medical treatment. These were older, had more comorbidities and higher in-hospital (46% vs. 24%; p < 0.001) and one year mortality (57.1% vs. 27.6%; p < 0.001) than operated patients. The main reason for surgical rejection was high surgical risk (57.1%) and the highest mortality when the cause were severe neurological conditions (76%). When the endocarditis team took the decision not to operate (25.5% of the patients), in-hospital (7%) and one-year mortality (17%) were low. In-hospital mortality associated with each surgical indication was 67% in heart failure, 53% in uncontrolled infection and 45% in prevention of embolisms (p < 0.001). Heart failure (OR: 2.26 CI95%: 1.29-3.96; p = 0.005), Staphylococcus aureus (OR: 3.17; CI95%: 1.72-5.86; p < 0.001) and persistent infection (OR: 5.07 CI95%: 2.85-9.03) are the independent risk factors of in-hospital mortality. One third of the patients with left-sided IE and formal surgical indication are rejected for surgery. In-hospital mortality is very high, especially when heart failure is the indication for surgery and when severe neurological conditions the reason for rejection. Short term prognosis of patients rejected by a specialized endocarditis team is favorable.

11.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38069986

RESUMEN

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Cateterismo Cardíaco , Estudios de Seguimiento , Estudios Prospectivos , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
12.
Int J Pediatr Otorhinolaryngol ; 166: 111473, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36812784

RESUMEN

OBJETIVE: To determine the utility of the electrically evoked stapedial reflex test (ESRT) and behavioral method in the CIs programming as an objective method to identify MCL levels in the CIs programming in pediatric patients. METHOD: Cross-sectional cohort study that included 20 pediatric patients with postlingual deafness and CI unilateral. They were performed clinical history, tympanometry, ESRT and by free field audiometry, before and after programming modifications according to MCL levels obtained by ESRT were performed. ESRT threshold was assessed with individual 300 ms stimuli on the 12 electrodes and recorded through manual decay. Likewise, the maximum comfort threshold (MCL) of each electrode was obtained through a behavioral analysis. RESULTS: No significant differences were found between the ESRT and behavioral method in MCLs levels in each of the electrodes evaluated. In addition, the correlation coefficients were significant and located in a range of 0.55-0.81, higher in electrodes 7, 8, and 9 (r = 0.77, 0.76, and 0.81, respectively). However, the median hearing threshold established by the ESRT was significantly lower compared to the behavioral threshold (36.0 vs. 47.0 dB, p < 0.0001), regardless of age (p = 0.249) or the etiology of hearing loss (p = 0.292). The difference between the tests was in the number of times to do it, the ESRT was done once and the behavioral on average 4 ± 1 times. CONCLUSION: Similar MCL thresholds were obtained in both ESRT and behavioral test, establishing that both methods are reliable for use in pediatric patients; however, ESRT allows shortening the time to achieve normal hearing and language acquisition thresholds in a more optimal time.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Niño , Humanos , Adulto , Estudios Transversales , Implantación Coclear/métodos , Reflejo , Umbral Auditivo/fisiología , Estimulación Eléctrica
13.
Heart ; 109(20): 1558-1563, 2023 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-37230740

RESUMEN

OBJECTIVE: To identify differences in left ventricular (LV) remodelling between patients with bicuspid aortic valve (BAV) and trileaflet aortic valve (TAV) with chronic aortic regurgitation (AR). METHODS: Retrospective cohort study of 210 consecutive patients undergoing cardiac magnetic resonance for AR evaluation. We divided the study population according to valvular morphology. Independent predictors of LV enlargement AR were evaluated. RESULTS: There were 110 patients with BAV and 100 patients with TAV. Patients with BAV were younger (mean age BAV vs TAV: 41±16 years vs 67±11 years; p<0.01), mostly male (% male BAV vs TAV: 84.5% vs 65%, p=0.01) and presented milder degrees of AR (median regurgitant fraction BAV vs TAV: 14 (6-28)% vs 22 (12-35)%, p=0.002). Both groups presented similar indexed LV volumes and ejection fraction. According to the degree of AR, at mild AR, patients with BAV presented larger LV volumes (BAV vs TAV: indexed end diastolic left ventricular volumes (iEDV): 96.5±19.7 vs 82.1±19.3 mL, p<0.01; indexed end systolic left ventricular volumes (iESV): 39.4±10.3 mL vs 33.2±10.5 mL, p=0.01). These differences disappeared at higher degrees of AR. Independent predictors of LV enlargement were regurgitant fraction (EDV: OR 1.118 (1.081-1.156), p<0.001; ESV: OR 1.067 (1.042-1.092), p<0.001), age (EDV: OR 0.940 (0.917-0.964), p<0.001, ESV: OR 0.962 (0.945-0.979), p<0.001) and weight (EDV: OR 1.054 (1.025-1.083), p<0.001). CONCLUSIONS: In chronic AR, LV enlargement is an early finding. LV volumes display a direct correlation with regurgitant fraction and an inverse association with age. Patients with BAV present larger ventricular volumes, especially at mild AR. However, these differences are attributable to demographic disparities; valve type is not independently associated with LV size.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Espectroscopía de Resonancia Magnética
14.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36898524

RESUMEN

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Diseño de Prótesis
15.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37565470

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de Prótesis
16.
J Calif Dent Assoc ; 40(6): 509-17, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22856036

RESUMEN

This report presents a protocol used to transfer the virtual treatment plan data to the surgical and prosthetic reality and its clinical application, bone site augmentation with computer-custom milled bovine bone graft blocks to their ideal architecture form, implant insertion based on image-guided stent fabrication, and the restorative manufacturing process through computed tomography-based software programs and navigation systems and the computer-aided design and manufacturing techniques for the treatment of the edentulous maxilla.


Asunto(s)
Informática Odontológica , Prótesis Dental de Soporte Implantado , Estética Dental , Arcada Edéntula/cirugía , Maxilar/cirugía , Planificación de Atención al Paciente , Pérdida de Hueso Alveolar/cirugía , Aumento de la Cresta Alveolar/métodos , Animales , Trasplante Óseo/métodos , Bovinos , Diseño Asistido por Computadora , Implantación Dental Endoósea/métodos , Implantes Dentales , Dentadura Completa Superior , Femenino , Humanos , Imagenología Tridimensional/métodos , Arcada Edéntula/rehabilitación , Persona de Mediana Edad , Ajuste Oclusal , Oseointegración/fisiología , Programas Informáticos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X/métodos , Trasplante Heterólogo , Interfaz Usuario-Computador
17.
Enferm Infecc Microbiol Clin (Engl Ed) ; 40(9): 507-516, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36336380

RESUMEN

Patients lacking humoral response have been suggested to develop a less severe COVID-19, but there are some reports with a prolonged, relapsing or deadly course. From April 2020, there is growing evidence on the benefits of COVID-19 convalescent plasma (CCP) for patients with humoral immunodeficiency. Most of them had a congenital primary immunodeficiency or were on treatment with anti CD20 antibodies. We report on three patients treated in our hospital and review thirty-one more cases described in the literature. All patients but three resolved clinical picture with CCP. A dose from 200 to 800ml was enough in most cases. Antibody levels after transfusion were negative or low, suggesting consumption of them in SARS-CoV-2 neutralization. These patients have a protracted clinical course shortened after CCP. CCP could be helpful for patients with humoral immunodeficiency. It avoid relapses and chronification. CCP should be transfused as early as possible in patients with COVID-19 and humoral immunodeficiency.


Asunto(s)
COVID-19 , Humanos , COVID-19/terapia , SARS-CoV-2 , Inmunización Pasiva/efectos adversos , Sueroterapia para COVID-19
18.
Heart ; 108(9): 725-732, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34285104

RESUMEN

OBJECTIVES: The balloon-expandable Sapien-3 valve demonstrated superior results in terms of residual aortic regurgitation when compared with self-expandable devices. We aimed to compare for the first-time early outcomes of Sapien-3 transcatheter heart valve (THV) with the balloon-expandable Myval device. METHODS: Consecutive real-world patients from nine European institutions with symptomatic severe aortic stenosis treated either with Sapien-3 or Myval THV devices after June 2018 were compared. Early clinical outcomes were prospectively gathered and blinded analysis of 30-day echocardiography was conducted. Matching for the following variables was performed: age, body surface area, Society of Thoracic Surgeons risk score, left ventricular function, mean gradient, transfemoral approach, aortic valvular calcium, aortic annulus mean diameter, area and eccentricity index. RESULTS: A total of 416 patients treated either with the Sapien-3 (n=286, 68.7%) or with Myval THV (n=130, 31.3%) were included and 103 pairs compared after matching. Baseline characteristics were similar. Procedural success rate (Sapien-3: 94.2%; Myval: 93.2%, p=0.219), 30-day mortality (Sapien-3: 2.9%; Myval: 0.97%, p=0.625), clinical efficacy (12.6 vs 4.9%, p=0.057) and early safety (12.6 vs 4.9%, p=0.096) were comparable. There was a lower need for new permanent pacemaker (15.5 vs 5.8% p=0.020) with Myval. No significant differences were found in terms of ≥moderate aortic regurgitation (1% for Sapien-3, 0% for Myval, p=0.314), but mean gradients were higher following Sapien-3 than after Myval (p<0.001). CONCLUSIONS: The new Myval balloon-expandable THV was favourable in terms of safety, with low rate of permanent pacemaker and with favourable residual gradients and paravalvular leak rate according to blinded echocardiographic analysis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
19.
Int J Cardiol ; 351: 25-31, 2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-34979152

RESUMEN

BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12­leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS: A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS: After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
20.
Rev Esp Cardiol (Engl Ed) ; 75(3): 213-222, 2022 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-34301507

RESUMEN

INTRODUCTION AND OBJECTIVES: Severe calcification is present in> 50% of coronary chronic total occlusions (CTOs) undergoing percutaneous intervention. We aimed to describe the contemporary use and outcomes of plaque modification devices (PMDs) in this context. METHODS: Patients were included in the prospective, consecutive Iberian CTO registry (32 centers in Spain and Portugal), from 2015 to 2020. Comparison was performed according to the use of PMDs. RESULTS: Among 2235 patients, wire crossing was achieved in 1900 patients and PMDs were used in 134 patients (7%), requiring more than 1 PMD in 24 patients (1%). The selected PMDs were rotational atherectomy (35.1%), lithotripsy (5.2%), laser (11.2%), cutting/scoring balloons (27.6%), OPN balloons (2.9%), or a combination of PMDs (18%). PMDs were used in older patients, with greater cardiovascular burden, and higher Syntax and J-CTO scores. This greater complexity was associated with longer procedural time but similar total stent length (52 vs 57mm; P=.105). If the wire crossed, the procedural success rate was 87.2% but increased to 96.3% when PMDs were used (P=.001). Conversely, PMDs were not associated with a higher rate of procedural complications (3.7 vs 3.2%; P=.615). Despite the worse baseline profile, at 2 years of follow-up there were no differences in the survival rate (PMDs: 94.3% vs no-PMDs: 94.3%, respectively; P=.967). CONCLUSIONS: Following successful wire crossing in CTOs, PMDs were used in 7% of the lesions with an increased success rate. Mid-term outcomes were comparable despite their worse baseline profile, suggesting that broader use of PMDs in this setting might have potential technical and prognostic benefits.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Anciano , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/cirugía , Humanos , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda