1.
Molecules ; 27(16)2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-36014448

RESUMEN

Textile reinforced concrete (TRC) has gained attention from the construction industry due to several characteristics such as its lightweight, high tensile strength, design flexibility, corrosion resistance and remarkably long service life. Some structural applications that utilize TRC components include precast panels, structural repairs, waterproofing elements and façades. TRC is produced by incorporating textile fabrics into thin cementitious concrete panels. However, in order to use this strengthening method in construction practice, a design model is required. Investigating the combined effect of conventional steel and textile reinforcement on the ductility behavior of composite TRC/RC one-way slab is vitally important. Therefore, the current study describes the proper methods of calculating the ductility of the composite concrete reinforced by a direct combination of conventional steel and textile reinforcement. Four methods are presented to calculate the ductility of the three considered one-way slab specimens. The three slabs having dimensions 1500 mm × 500 mm × 50 mm were reinforced by steel bars (SRC), by steel with one layer of carbon fabric (SRC + 1T), and by steel with two layers of carbon fabric (SRC + 2T). The three slab specimens were cast by the hand lay-up method, removed from the molds, cured, and then tested in flexure after 28 days using the four-point bending method. The obtained results and calculations revealed the non-reasonability of using the conventional method based on yielding of steel reinforcement as the only criterion in the ductility determination. The results also confirmed the suitability of using the energy-based method over other discussed methods in the calculation of the ductility for the hybrid reinforced members.

2.
Materials (Basel) ; 15(11)2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35683224

RESUMEN

Circular hollow steel tube columns are widely used in high-rise buildings and bridges due to their ductility and lower weight compared to reinforced concrete. The use of this type of steel section has several advantages over using reinforced concrete members. The present study investigates the bending behavior of steel circular hollow sections when subjected to bending loads. The variations in material characteristics with regard to position along the cross-section of a steel tube member is first considered in this experimental study, providing for a more accurate definition of the material behavior in the model. A supported beam tested by two-point loads is the loading type that is used to study the bending performance of steel tubes. Ten circular hollow beam specimens were prepared and tested up to and post the failure stage with the following dimensions: thickness (2, 3, and 6 mm), diameter (76.2, 101.6, and 219 mm), and span (1000, 1500, and 2000 mm). A finite element analysis has been conducted for these ten specimens using the ANSYS program. The finite element model is compared to experimentally obtained data to verify that both local and global behaviors are correctly considered. The load-deflection results of this analysis showed a good agreement with the experimental results. A parametric study also was performed that considered two variables, which were the effect of the presence of circular rings and the change of opening location in the length direction on the specimens' behavior. This study showed that the presence of the circular rings in the specimen led to an increase in its ultimate strength (of 53.24%) compared with the non-presence of these rings. In contrast, the presence of openings at 30, 40, and 50% from the specimen length reduced the strength capacity by 8.76, 14.23, and 17.88%, respectively.

3.
Materials (Basel) ; 15(12)2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-35744410

RESUMEN

The present study aimed at evaluating the mechanical performance under bending loads of circular hollow sections of steel. Different bending tests have been carried out by applying two-point loads, to determine and examine the effects of the diameter, the thickness of the section, and the span of the beam on the performance of the steel tube. The effects of square opening and variation in the number of openings on the performance of these sections have also been examined. Ten samples of hollow circular beams of varying thickness (2 mm, 3 mm, and 6 mm), varying diameter (76.2 mm, 101.6 mm, and 219 mm), and varying span (1000 mm, 1500 mm, and 2000 mm) were fabricated and tested for pre-failure and post-failure stages. The dimensions of the reference specimen considered were 3 mm in thickness, 101.6 mm in diameter, and 1500 mm in span. The results have shown that on increasing the section thickness by 200%, ductility and bearing strength were enhanced by 58.04% and 81.75%, respectively. Meanwhile, decreasing the section thickness by 67%, ductility and bearing strength were reduced by 64.86% and 38.87%, respectively. Moreover, on increasing the specimen diameter and on decreasing span, a significant increase in bearing strength and stiffness was observed; however, ductility was reduced. Meanwhile, on increasing the span of the specimen, all the parameters observed, i.e., bearing strength, stiffness, and ductility, decreased. On observing the ultimate strength of each specimen with square opening, the ultimate strength was reduced by 17.88%, 19.71%, and 14.23% for one, two-, and three-square openings, respectively. Moreover, the ductility was significantly reduced by 72.40%, 67.71%, and 60.88% for one, two-, and three-square openings/apertures, respectively, and led to the sudden failure of these specimens. The local buckling failure dominated for specimens having a D/t ratio more than 50 and showed very negligible levels of ovalization of the cross-section. Local buckling failure was observed to be prevented after providing the circular rings in the specimen, since bearing strength increased compared with the specimen without rings.

4.
Materials (Basel) ; 15(13)2022 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-35806621

RESUMEN

The composite shear wall has various merits over the traditional reinforced concrete walls. Thus, several experimental studies have been reported in the literature in order to study the seismic behavior of composite shear walls. However, few numerical investigations were found in the previous literature because of difficulties in the interaction behavior of steel and concrete. This study aimed to present a numerical analysis of smart composite shear walls, which use an infilled steel plate and concrete. The study was carried out using the ANSYS software. The mechanical mechanisms between the web plate and concrete were investigated thoroughly. The results obtained from the finite element (FE) analysis show excellent agreement with the experimental test results in terms of the hysteresis curves, failure behavior, ultimate strength, initial stiffness, and ductility. The present numerical investigations were focused on the effects of the gap, thickness of infill steel plate, thickness of the concrete wall, and distance between shear studs on the composite steel plate shear wall (CSPSW) behavior. The results indicate that increasing the gap between steel plate and concrete wall from 0 mm to 40 mm improved the stiffness by 18% as compared to the reference model, which led to delay failures of this model. Expanding the infill steel plate thickness to 12 mm enhanced the stiffness and energy absorption with a ratio of 95% and 58%, respectively. This resulted in a gradual drop in the strength capacity of this model. Meanwhile, increasing concrete wall thickness to 150 mm enhanced the ductility and energy absorption with a ratio of 52% and 32%, respectively, which led to restricting the model and reduced lateral offset. Changing the distance between shear studs from 20% to 25% enhanced the ductility and energy absorption by about 66% and 32%, respectively.