RESUMEN
We present a new hemoglobin variant, Hb Raklev, characterized by the substitution of leucine with glutamine at position 75 in the ß-globin chain. This variant was discovered inadvertently during an HbA1c evaluation using high performance liquid chromatography in a symptomless 54-year-old Caucasian woman, with the same variant also identified in her 16-year-old daughter. Purification of the hemoglobin revealed possibly diminished 2,3-bisphosphoglycerate (2,3-BPG) sensitivity, which may result in heightened oxygen affinity. Notably, two variants have been previously documented at this location: the unstable Hb Atlanta and the high-affinity Hb Pasadena.
Asunto(s)
Hemoglobinas Anormales , Globinas beta , Femenino , Humanos , Persona de Mediana Edad , Adolescente , Globinas beta/genética , Globinas beta/química , Leucina , Glutamina , Hemoglobinas Anormales/genética , Hemoglobinas Anormales/química , Cromatografía Líquida de Alta PresiónRESUMEN
BACKGROUND: Setting the dry weight and maintaining fluid balance is still a difficult challenge in dialysis patients. Overhydration is common and associated with increased cardiac morbidity and mortality. Pulmonary hypertension is associated with volume overload in end-stage renal dysfunction patients. Thus, monitoring pulmonary pressure by a CardioMEMS device could potentially be of guidance to physicians in the difficult task of assessing fluid overload in hemodialysis patients. CASE PRESENTATION: 61-year old male with known congestive heart failure deteriorated over 3 months' time from a state with congestive heart failure and diuresis to a state of chronic kidney disease and anuria. He began a thrice/week in-hospital hemodialysis regime. As he already had implanted a CardioMEMS device due to his heart condition, we were able to monitor invasive pulmonary artery pressure during the course of dialysis sessions. To compare, we estimated overhydration by both bioimpedance and clinical assessment. Pulmonary artery pressure correlated closely with fluid drainage during dialysis and inter-dialytic weight gain. The patient reached prescribed dry weight but remained pulmonary hypertensive by definition. During two episodes of intradialytic systemic hypotension, the patient still had pulmonary hypertension by current definition. CONCLUSION: This case report observes a close correlation between pulmonary artery pressure and fluid overload in a limited amount of observations. In this case we found pulmonary artery pressure to be more sensitive towards fluid overload than bioimpedance. The patient remained pulmonary hypertensive both as he reached prescribed dry weight and experienced intradialytic hypotensive symptoms. Monitoring pulmonary artery pressure via CardioMEMS could hold great potential as a real-time guidance for fluid balance during hemodialysis, though adjusted cut-off values for pulmonary pressure for anuric patients may be needed. Further studies are needed to confirm the findings of this case report and the applicability of pulmonary pressure in assessing optimal fluid balance.