Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Can J Cardiol ; 22(12): 1029-33, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17036097

RESUMEN

The Canadian Cardiovascular Society is the national professional society for cardiovascular specialists and researchers in Canada. In the spring of 2004, the Canadian Cardiovascular Society Council formed the Access to Care Working Group ('Working Group') to use the best science and information available to establish reasonable triage categories and safe wait times for access to common cardiovascular procedures. The Working Group decided to publish a series of commentaries to initiate a structured national discussion on this important issue, and the present commentary proposes recommended wait times for access to echocardiography. 'Emergent' echocardiograms should be performed within 24 h, 'urgent' within seven days and 'scheduled' (elective) within 30 days. A framework for a solution-oriented approach to improve access is presented.


Asunto(s)
Ecocardiografía , Accesibilidad a los Servicios de Salud , Canadá , Guías como Asunto , Humanos , Derechos del Paciente , Factores de Tiempo
2.
J Am Coll Cardiol ; 37(8): 2025-30, 2001 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-11419882

RESUMEN

OBJECTIVES: This study compared a prediction of mean left atrial pressure (P(LA)) ascertained by Doppler echocardiography of pulmonary venous flow (PVF), with predicted P(LA) using the pulmonary artery occlusion pressure (P(PAO)). BACKGROUND: In select patient groups, PVF variables correlate with P(PAO)) an indirect measure of P(LA). METHODS: In 93 patients undergoing cardiac surgery, we recorded with transesophageal echocardiography mitral valve early (E) and late (A) wave velocities, deceleration time (DT) of E (DT(E)), and pulmonary vein systolic (S) and diastolic (D) wave velocities, DT of D (DT(D)) and systolic fraction. The P(PAO) was measured using a pulmonary artery catheter zeroed to midaxillary level. A further catheter was held at midatrial level to zero a transducer and was then inserted into the left atrium. A prediction rule for P(LA) from DT(D) was developed in 50 patients and applied prospectively to estimate P(LA) in 43 patients. RESULTS: A close correlation (r = -0.92) was found between P(LA) and DT(D). Systolic fraction (r = -0.63), DT(E) (r = -0.61), D wave (r = 0.57), E wave (r = 0.52), and E/A ratio (r = 0.13) correlated less closely with P(LA). The mean difference between predicted and measured P(LA) was 0.58 mm Hg for DT(D) method and 1.72 mm Hg for P(PAO), with limits of agreement (mean +/- 2 SE) of -2.94 to 4.10 mm Hg and -2.48 to 5.92 mm Hg, respectively. A DT(D)) of <175 ms had 100% sensitivity and 94% specificity for a P(LA) of >17 mm Hg. CONCLUSIONS: Deceleration time of pulmonary vein diastolic wave is more accurate than P(PAO) in estimating left atrial pressure in cardiac surgical patients.


Asunto(s)
Función del Atrio Izquierdo , Venas Pulmonares/fisiología , Anciano , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Arteria Pulmonar/fisiología , Venas Pulmonares/diagnóstico por imagen , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Ultrasonografía Doppler
3.
Int J Hematol ; 56(2): 185-7, 1992 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1421181

RESUMEN

We report a 39-year-old female patient with a hepatic hemangioblastoma, polycythemia and elevated plasma erythropoietin (Epo) levels. Following orthotopic liver transplantation (OLTx), her plasma Epo levels and hematocrit normalized but began to rise several months later. This rise correlated with the appearance of multiple lung metastases. The tumor was implicated as the source of excess Epo production using Northern analysis of a resected metastatic lung nodule. Based on our results, the measurement of plasma Epo levels in patients with Epo secreting tumors could be of general utility in assessing tumor burden.


Asunto(s)
Biomarcadores de Tumor/sangre , Eritropoyetina/sangre , Hemangiosarcoma/diagnóstico , Neoplasias Hepáticas/diagnóstico , Adulto , Eritropoyetina/biosíntesis , Femenino , Hemangiosarcoma/metabolismo , Humanos , Neoplasias Hepáticas/metabolismo
4.
J Am Soc Echocardiogr ; 10(8): 830-9, 1997 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9356948

RESUMEN

Three-dimensional echocardiography has demonstrated superiority over two-dimensional techniques in the determination of left ventricular mass and volumes. We describe a technique based on a magnetic tracking system which provides rapid three-dimensional image acquisition from multiple acoustic windows. Interactive three-dimensional border tracking and reconstruction with a piecewise smooth subdivision model accurately reproduced phantom volume (calculated volume = 1.00 true volume - 0.6 ml, r = 1.000, standard error of the estimate = 1.3 ml), in vitro heart volume (calculated volume = 1.02 true volume - 1.3 ml, r = 1.000, standard error of the estimate = 0.4 ml), in vitro heart mass (calculated mass = 0.98 true mass + 1.4 gm, r = 0.998, standard error of the estimate = 2.5 gm), and in vivo stroke volume (calculated stroke volume = 1.18 Doppler stroke volume - 17.9 ml, r = 0.990, standard error of the estimate = 2.8 ml). The three-dimensional in vivo data sets, which include views from three acoustic windows, were acquired in less than 90 seconds. We conclude that this method of three-dimensional echocardiographic data acquisition and analysis overcomes limitations inherent in currently available systems.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Animales , Volumen Cardíaco , Bovinos , Humanos , Fantasmas de Imagen , Valores de Referencia , Reproducibilidad de los Resultados , Volumen Sistólico
5.
J Am Soc Echocardiogr ; 11(8): 761-9, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9719087

RESUMEN

The objective of this study was to develop and validate a three-dimensional technique of left ventricular shape analysis. Geometric phantoms and left ventricles of excised calf hearts, normal human subjects, and one subject each with aortic stenosis and dilated cardiomyopathy were reconstructed from three-dimensional echocardiograms. The fit between the reconstructions and true surfaces of the geometric phantoms and excised ventricles was determined. To evaluate in vivo left ventricular shape, a center axis was constructed from the centroid of the mitral annulus to the furthest endocardial point. Regional shape was evaluated as the relative distances of 16 separate myocardial segments from the center axis compared with a population-derived mean value. Global shape was evaluated as the average standard deviation from the normal value over the 16 segments. The system precisely reproduced the shapes of the phantoms and excised left ventricles (root-mean-square error between true and reconstructed surface 1.0 0.2 mm and 1.2 0.8 mm, respectively). The in vivo shape analysis differentiated the pathological from normal left ventricles.


Asunto(s)
Ecocardiografía Tridimensional , Corazón/anatomía & histología , Adulto , Animales , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cardiomiopatía Dilatada/diagnóstico por imagen , Bovinos , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/anatomía & histología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Fantasmas de Imagen
6.
J Am Soc Echocardiogr ; 11(2): 188-200, 1998 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9517558

RESUMEN

Ten phantoms were scanned with a multiplane transesophageal echocardiographic probe in a water bath to assess a new method for three-dimensional modeling of the mitral annulus. The annulus was reconstructed from manually outlined borders with Fourier series in each of the three spatial coordinates. Comparisons with direct measurements by least-squares linear regression gave coefficients of determination of 0.99 for annular height, area, and circumference. Expressed as a percentage of their true values, the mean +/- SD of the errors were -0.1% +/- 3.0% for annular height, -2.8% +/- 3.1% for area, and -0.2% +/- 1.7% for circumference. The mean residual error length for phantoms was 0.64 mm compared with 1.21 mm in nine patients studied during general anesthesia. This method gives accurate and precise measurements of the mitral annulus in vitro and should be valuable for studying its morphology and dynamics in vivo.


Asunto(s)
Ecocardiografía Transesofágica , Procesamiento de Imagen Asistido por Computador , Válvula Mitral/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen
7.
J Heart Valve Dis ; 9(6): 805-8; discussion 808-9, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11128789

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The surgical management of tricuspid valve endocarditis, especially in patients with positive serology for HIV and hepatitis C, is complicated by the inappropriateness of reconstruction and the late complications of mechanical prostheses and bioprostheses. Late results of mitral homograft replacement of the tricuspid valve have been satisfactory, but evidence of moderate and severe regurgitation appears in some patients. This report presents a novel approach to implantation of a mitral homograft in the tricuspid position. METHODS: Five patients with complications of native tricuspid valve endocarditis underwent mitral homograft replacement of the tricuspid valve, the homograft being implanted with the anterior leaflet orientated to the septum, the papillary muscles exteriorized and sutured to the right ventricular wall, the posteromedial muscle anteriorly, and the anterolateral muscle inferiorly. The annular attachment was reinforced with a rigid mitral annuloplasty ring in the anti-anatomical relationship. RESULTS: There was no early mortality. Among three patients available for echocardiographic assessment during the first year, regurgitation was absent in two cases, and trivial in one case. The latter patient died of a drug overdose after nine months. Two patients required insertion of atrioventricular pacemakers for complete heart block. CONCLUSION: This novel extension to the technique of mitral homograft replacement of the tricuspid valve for uncontrollable native endocarditis in drug abusers makes the procedure more technically feasible, and should be considered a procedure of choice.


Asunto(s)
Válvula Mitral/trasplante , Válvula Tricúspide/cirugía , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Portador Sano , Criopreservación , Endocarditis/cirugía , Femenino , Seropositividad para VIH , Hepatitis C , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Factores de Riesgo , Abuso de Sustancias por Vía Intravenosa , Trasplante Homólogo , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Ultrasonografía
8.
Can J Cardiol ; 14(9): 1148-50, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9779020

RESUMEN

Infectious complications of coronary angioplasty and stenting are uncommon. A 70-year-old man is presented who underwent percutaneous transluminal coronary angioplasty (PTCA) and stenting of an occluded left anterior descending artery. This was complicated by Staphylococcus aureus pericarditis with tamponade. He was successfully treated with a closed drainage and antibiotics. This is the first reported case in the literature that documents purulent pericarditis and tamponade following percutaneous revascularization.


Asunto(s)
Angioplastia Coronaria con Balón , Taponamiento Cardíaco/etiología , Enfermedad Coronaria/cirugía , Pericarditis/etiología , Infecciones Estafilocócicas/etiología , Stents , Anciano , Taponamiento Cardíaco/microbiología , Ecocardiografía , Femenino , Humanos , Masculino , Revascularización Miocárdica , Derrame Pericárdico/diagnóstico por imagen , Pericarditis/microbiología , Complicaciones Posoperatorias , Factores de Riesgo
9.
Can J Cardiol ; 13(5): 517-21, 1997 May.
Artículo en Inglés | MEDLINE | ID: mdl-9179091

RESUMEN

Exercise-induced left bundle branch block is a relatively rare finding during exercise tolerance testing. A 36-year-old female with intermittent exercise-induced left bundle branch block, a MIBI study suggesting anterior ischemia and normal coronary arteries is reported. A review of the English and French language literature published from January 1985 to January 1996 is presented. Exercise-induced left bundle branch block has been reported in association with and without structural heart disease. Pooled mortality in the group with structural heart disease was 2.7% per year, and mortality was 0.17% per year when no structural heart disease was identified. Exercise-induced left bundle branch block has been reported to resolve with therapy. Noninvasive testing appears to have limited ability to detect or exclude coronary artery disease in this group. If a definitive cardiac diagnosis is required, strong consideration should be given to coronary angiography.


Asunto(s)
Bloqueo de Rama/etiología , Esfuerzo Físico , Tecnecio Tc 99m Sestamibi , Adulto , Medios de Contraste , Reacciones Falso Positivas , Femenino , Humanos
10.
Can J Cardiol ; 13(4): 346-50, 1997 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9141965

RESUMEN

OBJECTIVE: To evaluate the effect of aortic valve replacement on left ventricular function, functional status and exercise duration in an adult population with valvular aortic stenosis. DESIGN: Prospective study of initially asymptomatic patients with pre- and postvalve replacement echocardiography, functional status score and exercise data. SETTING: University-affiliated, tertiary care teaching hospital. PATIENTS: Valvular aortic stenosis patients referred from academic and private practice internists and cardiologists (n = 34, 65% men, mean age 68 +/- 11 years, preoperative aortic valve area 0.9 +/- 0.4 cm2). INTERVENTIONS: Annual Doppler echocardiography, functional status questionnaires and, if possible, Bruce protocol maximal exercise tolerance tests. MAIN RESULTS: Aortic valve replacement resulted in a decrease in maximum jet velocity (pre 4.7 +/- 0.7 versus post 2.9 +/- 0.7 m/s, P = 0.0001) and left ventricular mass (pre 167 +/- 37 versus post 134 +/- 32 g, P = 0.0001) and an increase in left ventricular ejection fraction (pre 65 +/- 11 versus post 69 +/- 10%, P = 0.05) at rest. However, there was no change in the ratio of early to atrial diastolic filling velocities (pre 1.2 +/- 0.5 versus post 1.4 +/- 0.8, not significant), exercise tolerance as assessed by estimated functional aerobic impairment (pre 26 +/- 32 versus post 22 +/- 27%, not significant) or functional status score (pre 89 +/- 13 versus post 91 +/- 11, not significant). CONCLUSIONS: When the aortic valve is replaced promptly at symptom onset, despite improvement in resting left ventricular systolic performance, there is no evidence of improvement in exercise capacity or functional status.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Prueba de Esfuerzo , Prótesis Valvulares Cardíacas , Función Ventricular Izquierda , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Ecocardiografía Doppler , Femenino , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
11.
Can J Cardiol ; 16(5): 667-9, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10833545

RESUMEN

Cardiac side effects of mesalamine are uncommon. A young man with ulcerative colitis who developed recurrent chest pain and electrocardiographic changes while on mesalamine is presented. Various causes of mesalamine-induced chest pain are discussed.


Asunto(s)
Angina de Pecho/inducido químicamente , Antiinflamatorios no Esteroideos/efectos adversos , Mesalamina/efectos adversos , Edema Pulmonar/inducido químicamente , Síncope/inducido químicamente , Adulto , Angina de Pecho/fisiopatología , Colitis Ulcerosa/tratamiento farmacológico , Electrocardiografía/efectos de los fármacos , Sistema de Conducción Cardíaco/efectos de los fármacos , Humanos , Masculino , Edema Pulmonar/fisiopatología , Síncope/fisiopatología
12.
J Invasive Cardiol ; 12(6): 324-6, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10859721

RESUMEN

Percutaneous transseptal mitral valvuloplasty was attempted in a patient with severe rheumatic mitral stenosis. Introduction of the balloon into the left atrium resulted in thrombotic occlusion of the mitral valve. Circulatory arrest ensued. The thrombus was disrupted during cardiopulmonary resuscitation. Thrombolysis was administered and the patient recovered uneventfully.


Asunto(s)
Cateterismo/efectos adversos , Estenosis de la Válvula Mitral/terapia , Válvula Mitral , Terapia Trombolítica , Trombosis/etiología , Anticoagulantes/uso terapéutico , Ecocardiografía Transesofágica , Femenino , Enfermedades de las Válvulas Cardíacas/etiología , Heparina/uso terapéutico , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/tratamiento farmacológico , Estenosis de la Válvula Mitral/etiología , Cardiopatía Reumática/complicaciones , Trombosis/diagnóstico por imagen
13.
Heart ; 92(10): 1369-72, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16339816

RESUMEN

Valvular heart disease is a significant cause of morbidity and mortality. Rates increase with age and the prevalence will increase as the population ages. Several factors have led to an interest in expanding percutaneous valve repair and replacement techniques to more lesions in more patients. This review explores current percutaneous valve repair and replacement techniques in mitral stenosis, mitral regurgitation, aortic stenosis and aortic regurgitation in adults, outlines the future directions, and discusses some technique-related issues.


Asunto(s)
Endoscopía/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos
14.
Artículo en Inglés | MEDLINE | ID: mdl-6135540

RESUMEN

Total cholesterol and high density lipids (HDL) were measured in the blood of Atlantic salmon (Salmo salar), brook trout (Salvelinus fontinalis) and rainbow trout (Salmo gairdneri) from a variety of dietary and environmental regimes. At spawning the total cholesterol of cage reared S. salar was high compared to sea ranched S. salar. Starvation of S. salar in freshwater for 6-11 months depressed total blood cholesterol levels, but not to unusually low levels. A cholesterol supplement of 0.02 g/100 g body weight to a chow diet of 0.38 g/100 g body weight had no significant effect on the total blood cholesterol level in Salvelinus fontinalis. The high proportion of HDL in the blood of S. salar is discussed in terms of its possible importance during the atherosclerotic lesion formation that normally accompanies spawning in these salmon.


Asunto(s)
Colesterol/sangre , Salmón/sangre , Salmonidae/sangre , Trucha/sangre , Animales , Arteriosclerosis/sangre , HDL-Colesterol , Dieta , Ambiente , Femenino , Lipoproteínas HDL/sangre , Masculino , Reproducción , Factores Sexuales , Inanición/sangre
15.
Anal Biochem ; 148(2): 451-60, 1985 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-4061821

RESUMEN

A highly sensitive and quantitative assay for measuring protein in solution based on the capacity of protein to bind silver is described. In this procedure, protein samples are first treated with glutaraldehyde and then exposed to ammoniacal silver. After 10 min, the reaction is terminated by the addition of sodium thiosulfate and the optical density measured at 420 nm. The useful range of the assay for the majority of standard proteins tested lies between 15 and 2000 ng. This represents a 100-fold increase in sensitivity over the Coomassie brilliant blue dye-binding procedure. There is little or no interference from carbohydrates, nonionic detergents, or ethanol, and pretreatment of protein samples with Bio-Gel P-2 to remove salts, thiol agents, EDTA, and sodium dodecyl sulfate makes this procedure compatible with most commonly used buffers. The cost in terms of silver utilization is nominal with a typical assay involving 10 samples tested in triplicate amounting to less than $0.02 U. S.


Asunto(s)
Proteínas/análisis , Plata , Animales , Bovinos , Cromatografía en Gel , Caballos , Humanos , Microquímica , Unión Proteica , Solubilidad , Soluciones/análisis
16.
J Rheumatol ; 19(11): 1807-9, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1491407

RESUMEN

Pulmonary hypertension is the most frequent cause of death in patients with mixed connective tissue disease. The pulmonary hypertension is progressive and difficult to treat effectively. These patients experience considerable morbidity secondary to diminished cardiac function. We describe a case in which sequential administration of cyclophosphamide and cyclosporine A favorably altered the clinical and hemodynamic course of this serious complication.


Asunto(s)
Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Enfermedad Mixta del Tejido Conjuntivo/complicaciones , Enfermedad Mixta del Tejido Conjuntivo/tratamiento farmacológico , Adulto , Ciclofosfamida/uso terapéutico , Ciclosporina/uso terapéutico , Femenino , Hemodinámica/efectos de los fármacos , Humanos
17.
J Inherit Metab Dis ; 25(2): 131-2, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12118528

RESUMEN

Pulmonary hypertension (PHT) is a complication of Gaucher disease. Screening with echocardiography is recommended for Gaucher patients. Two patients naive to enzyme replacement therapy are presented in whom resting echocardiography revealed no evidence of PHT. One of the patients also had normal pulmonary artery pressures at cardiac catheterization. The diagnosis of PHT was made with open lung biopsy in one patient and dobutamine echocardiography in the other. In both cases, diagnosis of PHT altered patient management. Resting echocardiographic assessment may fail to identify PHT in patients with Gaucher disease.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía , Enfermedad de Gaucher/complicaciones , Hipertensión Pulmonar/diagnóstico , Adulto , Reacciones Falso Negativas , Femenino , Enfermedad de Gaucher/tratamiento farmacológico , Humanos , Hipertensión Pulmonar/etiología , Masculino
18.
Crit Care Med ; 26(11): 1829-33, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9824075

RESUMEN

OBJECTIVE: To determine if nonsurvivors have a more abnormal pattern of left ventricular relaxation than survivors with severe sepsis. DESIGN: Prospective, observational, cohort study. SETTING: Intensive care unit in a university-affiliated tertiary care hospital. PATIENTS: Twenty-four adults with severe sepsis. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Baseline clinical and hemodynamic variables, Acute Physiology and Chronic Health Evaluation (APACHE) II scores and Doppler echocardiographic mitral inflow pattern (analyzed for normalized peak early filling rate [E/VTI, systolic volumes/sec], deceleration time [msec], and early to atrial filling velocity ratio [E/A]). There were seven deaths. The patients did not differ in baseline demographics, inotropic infusions, hemodynamic measurements or ventilatory settings or variables. Nonsurvivors had a more abnormal pattern of left ventricular relaxation (E/VTI, 4.7 [range 3.8 to 5.8] vs. 5.8 [range 3.8 to 8.9], p= .04; deceleration time, 235 [range 209 to 367] vs. 182 [range 155 to 255], p = .002). E/A showed a nonsignificant trend in the same direction (0.9 [range 0.8 to 1.6] vs. 1.2 [range 0.7 to 1.9], p = .12). In a multivariate analysis, deceleration time (p< .004) and APACHE II score (p < .02) were the only independent predictors of mortality. CONCLUSION: Severe sepsis nonsurvivors have a more abnormal echocardiographic pattern of left ventricular relaxation than survivors.


Asunto(s)
Ecocardiografía Doppler , Sepsis/diagnóstico por imagen , Sepsis/fisiopatología , APACHE , Enfermedad Aguda , Adulto , Anciano , Análisis de Varianza , Estudios de Cohortes , Diástole , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Sepsis/mortalidad , Estadísticas no Paramétricas , Función Ventricular Izquierda
19.
Am Heart J ; 137(2): 298-306, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9924164

RESUMEN

BACKGROUND AND METHODS: The goal of this study was to examine the ability of physical examination to predict valvular aortic stenosis severity and clinical outcome in 123 initially asymptomatic subjects (mean age 63 +/- 16 years, 70% men) followed up for a mean of 2.5 +/- 1.4 years. RESULTS: Doppler aortic jet velocity correlated with systolic murmur intensity (P =.003) and timing (P =.0002), a single second heart sound (P =.01), and carotid upstroke delay (P <.0001) and amplitude (P <.0001). However, no physical examination findings had both a high sensitivity and a high specificity for the diagnosis of severe valvular obstruction. Clinical end points were reached in 56 subjects (46%), including 8 deaths and 48 valve replacements for symptom onset. Univariate predictors of outcome included carotid upstroke delay (P =.0008) and amplitude (P =.0006), systolic murmur grade (P <.0001) and peak (P =.0003), and a single second heart sound (P =.003). On multivariate Cox regression analysis, the only physical examination predictor of outcome was carotid upstroke amplitude (P =.0001). CONCLUSIONS: Although physical examination findings correlate with stenosis severity, echocardiography still is needed to exclude severe obstruction reliably when this diagnosis is suspected.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Examen Físico , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sensibilidad y Especificidad , Factores de Tiempo
20.
Circulation ; 95(9): 2262-70, 1997 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-9142003

RESUMEN

BACKGROUND: Only limited data on the rate of hemodynamic progression and predictors of outcome in asymptomatic patients with valvular aortic stenosis (AS) are available. METHODS AND RESULTS: In 123 adults (mean age, 63 +/- 16 years) with asymptomatic AS, annual clinical, echocardiographic, and exercise data were obtained prospectively (mean follow-up of 2.5 +/- 1.4 years). Aortic jet velocity increased by 0.32 +/- 0.34 m/s per year and mean gradient by 7 +/- 7 mm Hg per year; valve area decreased by 0.12 +/- 0.19 cm2 per year. Kaplan-Meier event-free survival, with end points defined as death (n = 8) or aortic valve surgery (n = 48), was 93 +/- 5% at 1 year, 62 +/- 8% at 3 years, and 26 +/- 10% at 5 years. Univariate predictors of outcome included baseline jet velocity, mean gradient, valve area, and the rate of increase in jet velocity (all P < or = .001) but not age, sex, or cause of AS. Those with an end point had a smaller exercise increase in valve area, blood pressure, and cardiac output and a greater exercise decrease in stroke volume. Multivariate predictors of outcome were jet velocity at baseline (P < .0001), the rate of change in jet velocity (P < .0001), and functional status score (P = .002). The likelihood of remaining alive without valve replacement at 2 years was only 21 +/- 18% for a jet velocity at entry > 4.0 m/s, compared with 66 +/- 13% for a velocity of 3.0 to 4.0 m/s and 84 +/- 16% for a jet velocity < 3.0 m/s (P < .0001). CONCLUSIONS: In adults with asymptomatic AS, the rate of hemodynamic progression and clinical outcome are predicted by jet velocity, the rate of change in jet velocity, and functional status.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía , Prueba de Esfuerzo , Anciano , Estenosis de la Válvula Aórtica/cirugía , Femenino , Predicción , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Análisis de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda