Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Orthopade ; 39(2): 171-81, 2010 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-20094703

RESUMEN

The stabilization of long bone fractures through reaming the medullary cavity and insertion of an intramedullary nail, with or without locking bolts, was a standard procedure in fracture treatment for a long time. With the development of nails, which can be applied without reaming, the procedure lost importance. This publication presents the mechanical principles and impact of reaming on the bone. It describes how the pressure of the drill head and drill wave leads to a compression of medullary contents into the cortical vascular system. With the development of new drilling devices the direct effects of pressurization can be minimized and then become similar to those of unreamed intramedullary nailing. Lowering the pressure during reaming also prevents the formation of mixed thrombosis on the base of a nucleus of the bone marrow in the venous circulatory system and the danger of a pulmonary embolism. The majority of experimental research shows slightly faster fracture healing after reamed nailing. In the few randomized clinical studies presented, exclusively coming from Canada, accelerated fracture healing has also been confirmed. Aside from this it was also shown that there were fewer cases of non-unions and implant failures and less need for secondary surgeries when reamed nailing was used. Despite the difficulty in rating the clinical trials presented, due to the high number of participating clinics, the impression remains that in the course of fracture healing intramedullary reamed nailing has some advantages in comparison to unreamed nailing. An obvious advantage is that earlier and sometimes immediate weight-bearing can be tolerated. Today nevertheless unreamed nailing is favoured especially in German-speaking countries. This is maybe due to the necessary classic procedure of planning, positioning on the fracture table and reaming in steps, which make the operation slightly more complex, requiring a certain amount of armamentarium and technical understanding. In any case reamed intramedullary nailing offers an alternative procedure for many indications; to treat a hypertrophic non-union of the shaft of the long bones it remains the method of first choice.


Asunto(s)
Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/métodos , Curación de Fractura/fisiología , Fracturas de la Tibia/cirugía , Adulto , Fenómenos Biomecánicos , Diseño de Equipo , Fracturas del Fémur/diagnóstico por imagen , Fijación Intramedular de Fracturas/instrumentación , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/cirugía , Radiografía , Ensayos Clínicos Controlados Aleatorios como Asunto , Fracturas de la Tibia/diagnóstico por imagen , Soporte de Peso/fisiología
2.
J Bone Joint Surg Br ; 87(3): 426-32, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15773659

RESUMEN

The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.


Asunto(s)
Fijación Interna de Fracturas/métodos , Tibia/fisiología , Fracturas de la Tibia/cirugía , Fenómenos Biomecánicos , Densidad Ósea/fisiología , Clavos Ortopédicos , Fijadores Externos , Fijación Interna de Fracturas/instrumentación , Humanos , Fijadores Internos , Fracturas de la Tibia/fisiopatología
3.
J Bone Joint Surg Am ; 86(12): 2621-8, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15590845

RESUMEN

BACKGROUND: The treatment of displaced Colles-type fractures of the distal part of the radius remains a challenge. Two procedures for closed reduction and Kirschner wire osteosynthesis of these fractures were compared in a prospective randomized study. METHODS: One hundred consecutive patients with a Colles fracture of the distal part of the radius (AO classification 23-A2, 23-A3, or 23-C1) were treated over an eighteen-month period. One group was managed with the conventional method, described by Willenegger and Guggenbuhl in 1959, in which two Kirschner wires are introduced into the styloid process of the radius. The other group was treated with the Kapandji method, as modified by Fritz et al., in which two Kirschner wires are inserted into the fracture gap and a third is placed through the styloid process. Postoperative care was standardized for both groups and carried out according to a strict procedure. Forty patients who had been operated on according to the modified Kapandji method and forty-one treated with the Willenegger technique were available for follow-up, for a follow-up rate of 81%. The follow-up assessment was performed with a modified version of the Martini score. RESULTS: The median time to follow-up was ten months (range, six to twenty months). The results as assessed with the Martini score were, on the average, good to very good for the patients treated with the Kapandji method and satisfactory to good for the patients treated with the conventional Kirschner wire fixation. The duration of radiographic exposure was significantly shorter with the Kapandji method than with the Willenegger technique. CONCLUSIONS: Conventional Kirschner wire fixation remains a good method of osteosynthesis for the treatment of displaced fractures of the distal part of the radius. We found both the functional and radiographic outcomes of the Kapandji method to be significantly better than those of the Willenegger technique. LEVEL OF EVIDENCE: Therapeutic study, Level I-1a (randomized controlled trial [significant difference]). See Instructions to Authors for a complete description of levels of evidence.


Asunto(s)
Hilos Ortopédicos , Fractura de Colles/cirugía , Fijación Interna de Fracturas/métodos , Adulto , Anciano , Anciano de 80 o más Años , Fractura de Colles/diagnóstico por imagen , Femenino , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Radiografía
4.
J Orthop Trauma ; 12(8): 540-6, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9840786

RESUMEN

OBJECTIVE: To measure the differences in intramedullary (IM) pressure for commercial reamer systems. DESIGN: IM pressure values for the following systems were measured: AO, Biomet, Howmedica grey reamer, Richards, and Zimmer. To investigate the influence of shaft diameter, the AO reamer head was additionally connected to a small shaft (A6/A7). The pressures were measured in plexiglass tubes filled with a mixture of petroleum jelly and paraffin oil with flow properties at 20 degrees C equivalent to those of bovine medullary fat at 36 degrees C. The reaming assemblies were inserted into the tubes using a materials testing machine at a constant speed. In addition, pressure measurements were made using five pairs of human femora to compare Biomet reamers with the AO reamer with thin, flexible drives (A6/A7). RESULTS: The following pressure distributions were obtained (millimeters of mercury; mean value +/- standard deviation): 9.5-millimeter reamer: low for Biomet (272+/-39); moderate for Richards (810+/-101); and high for Howmedica (990+/-132), AO conventional (1,000+/-97), and Zimmer (1,140+/-183); 13.0-millimeter reamer: low for Biomet (132+/-21), Howmedica (204+/-45), and Zimmer (226+/-33); moderate for AO conventional (474+/-42); and very high for Richards (1,734+/-127). The second worst system (AO conventional: 1,000+/-97) became the second best system by simple reduction of the shaft diameter (A6/A7: 378+/-33). CONCLUSION: A comparison of shaft diameters and pressure increase clearly showed that the system with the thinnest shaft produced the lowest pressure values and vice versa.


Asunto(s)
Fijación Intramedular de Fracturas/instrumentación , Diseño de Equipo , Fémur/cirugía , Humanos , Presión
5.
Acta Chir Orthop Traumatol Cech ; 60(4): 240-6, 1993.
Artículo en Alemán | MEDLINE | ID: mdl-8284999

RESUMEN

It is not possible and seems not reasonable to treat all kinds of femoral shaft fractures in the same way. Any type of osteosynthesis has its own advantages and disadvantages. The decision towards an operative procedure and the application of a special method depends on the individual situation of the patient and on the familiarity and experience of the orthopedic surgeon with the different available procedures. Single fractures, shaft fractures in combination with jointnear lesions, fractures in polytraumatized patients require a differentiated approach. Doubtless, nowadays the trend to treat all femoral shaft fractures by i.m. nailing is obvious. But it seems that there still exist a lot of indications where the plate or an external fixation can be used with remarkable advantages.


Asunto(s)
Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Fijación de Fractura/métodos , Humanos , Radiografía
6.
Aktuelle Traumatol ; 18 Suppl 1: 40-5, 1988 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-2902753

RESUMEN

The article reviews the theoretical fundamentals and practical applications of intramedullary nailing. In particular, the author deals with the theoretical, mechanical and biological aspects, discusses the indications, and describes the definitely established results of medullary nailing.


Asunto(s)
Fijación Intramedular de Fracturas/métodos , Fenómenos Biomecánicos , Fracturas del Fémur/cirugía , Humanos , Fracturas de la Tibia/cirugía , Cicatrización de Heridas
7.
Aktuelle Traumatol ; 17(1): 29-31, 1987 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-2883844

RESUMEN

Treatment of combined fractures of the shaft of the femur and near the hip joint presents special problems. The pattern of these problems is presented on the basis of four cases that had occurred during a six-month period. A useful method for the appropriate treatment of such fractures by surgical means is demonstrated.


Asunto(s)
Tornillos Óseos , Fracturas del Fémur/cirugía , Fracturas Abiertas/cirugía , Fracturas de Cadera/cirugía , Adulto , Placas Óseas , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad
8.
Aktuelle Traumatol ; 10(2): 117-21, 1980 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-6107013

RESUMEN

Whether or not an effective locking of the medullary nail in transverse direction is achieved after medullary nailing of the tibia, is a moot point in literature. Researchers agree, however, that the essential locking of the nail occurs on the longitudinal axis of the nail. The authors conducted studies with strain gauges measuring the expansion and introduced together with the nail in order to obtain information on the elastic performance of the nail in transverse and longitudinal direction. The curves plotted from the data obtained, present a typical appearance. After the tibia has been properly reamed, a medullary nail of the AO is subjected to both elastic transverse compression as well as slight longitudinal bending after nailing. In case of excessive reaming the transverse elastic effect is only slight. If, on the other hand, reaming is not effected wide enough, the bone may burst open or the nail may undergo plastic deformation.


Asunto(s)
Fijación Intramedular de Fracturas , Estrés Mecánico , Tibia/fisiología , Fenómenos Biomecánicos , Humanos , Fracturas de la Tibia/fisiopatología , Fracturas de la Tibia/cirugía
9.
Aktuelle Traumatol ; 18(5): 187-91, 1988 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-2907242

RESUMEN

The authors report on 140 cases of fractures near the hip joint, which had been treated by applying a dynamic hip compression screw (DHS). DHS is an ideal method for stabilising pertrochanteral stable and lateral fractures. In unstable pertrochanteral fractures it is recommended to use a 130 degrees or 150 degrees DHS, depending on the age and the patient's preoperative ability to walk. In medial fractures of the neck of the femur the use of DHS offers no advantage compared with screwing or total endoprosthesis. The article reports on the postoperative results. In respect of these results DHS appears to be superior to fracture nailing according to Ender.


Asunto(s)
Tornillos Óseos , Fracturas de Cadera/cirugía , Complicaciones Posoperatorias/etiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cicatrización de Heridas
10.
Aktuelle Traumatol ; 18(2): 64-7, 1988 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-2898876

RESUMEN

177 patients with fractures near the hip joint were operated on between January 1983 and December 1985. The fractures were treated with Ender pinnings, total endoprostheses and dynamic hip screws (compression screw fixation). Up to June 1984 surgery was performed after the patients had been allowed a stabilisation phase of 4 days on the average, but from July 1984 onwards we aimed at performing immediate surgery within 12 hours. The second group was compared with the first group in a retrospective study in respect of recumbent period and mortality (hospital mortality and mortality after 8 months). The period during which the patients had to remain recumbent in the hospital was found to be considerably shorter, but there were no statistically significant differences in respect of mortality. The causes and consequences are discussed.


Asunto(s)
Urgencias Médicas , Fijación Intramedular de Fracturas , Fracturas de Cadera/cirugía , Prótesis de Cadera , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Cicatrización de Heridas
11.
Aktuelle Traumatol ; 10(3): 137-42, 1980 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-6111188

RESUMEN

The evaluation of 98 pseudoarthroses of the shaft of the humerus showed that 42 of these occurred after conservative and 56 after surgical treatment of the original fracture. It appears that pseudoarthroses are caused in conservative treatment chiefly by the traction methods. Among the surgical methods, intramedullary nailing does not seem to bring about sufficient stabilization with a satisfactory measure of safety, whereas in the case of plate osteosynthesis, errors in respect of operation technique are mainly responsible for causing pseudoarthroses. All 98 pseudoarthroses returned to normal condition after proper plate osteosynthesis and, if necessary additional deposition of cancellous bone graft.


Asunto(s)
Fijación Interna de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/efectos adversos , Fracturas del Húmero/complicaciones , Seudoartrosis/etiología , Adolescente , Adulto , Anciano , Placas Óseas/efectos adversos , Niño , Femenino , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Seudoartrosis/terapia
12.
Aktuelle Traumatol ; 16(3): 90-3, 1986 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-2874703

RESUMEN

Lesion of the meniscus is the most frequently occurring lesion in the region of the knee joint. Opinions are still divided as to the effects of partial, subtotal or total meniscectomy in provoking and/or promoting arthrosis. In this study, 70 patients with isolated injury of the meniscus were followed up on an average 11 years after meniscectomy. The subjective and clinical findings are juxtaposed with the x-ray findings. It was found that no arthrosis or no increase of the already preoperatively existing degree of arthrosis was seen in only 21.4% of the patients. Correlations are set up between instability resulting from meniscectomy on the one hand, and degree of arthrosis on the other.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Adolescente , Adulto , Artritis/etiología , Femenino , Estudios de Seguimiento , Humanos , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Lesiones de Menisco Tibial , Factores de Tiempo
13.
Aktuelle Traumatol ; 22(3): 104-13, 1992 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-1353289

RESUMEN

The reasons of fat embolism as well as the following fat embolism syndrome are most likely long bone fractures, especially if the femur is participated. On the other hand there are cases, where a severe concussion of the entire body caused fat embolism. But it is also supposed, that intramedullary reaming as well as the insertion of knee- and hip-prostheses could be a releasing factor, because the applicated pressure on the medullary canal can cause a fat release in the systemic blood system. The morbidity depends on age and fracture, which is on fractures between 0.9 and 2%. The most affected group are people between 18 and 28 years of age. The fat embolism is manifesting at 46-60% of the patients in the first 24 hours and over 90% of the patients are affected in the first three days. If you look at the metabolic changes, you will find shortly after the fracturing process a rapid increase of free fatty acids (FFA), as well as an increase of the plasmatic enzyme levels (lipase, GPT, GOT, GLDH, LDH, etc.), catecholamines and glucocorticoids. In order to discuss the pathogenesis in a fairly complete way, you have to take different theories into consideration, because several parallel running processes--which are influencing each other--are leading to the syndrome. Infloating theory: Proceeding on the assumption that contents of the bone marrow are floating out of the fracture gap into the venous system and are leading to fat embolism in the lungs. Lipase theory: You can diagnose in 50-70% of the fracture patients an increase of the lipase level, which is correlating with the manifestation of the fat embolism. The lipase releases fat from the body depositories in addition to the fat, who is coming out of the fracture gap. Shock and coagulation theory: During shock the microcirculation is decelerated, the blood viscosity is increased and the suspension stability of the cellular blood components is decreased, which is leading to the sludging phenomenon. So the capillaries of the lungs and the brain are a kind of sludge filter of the blood, that is changed in its suspensions stability. Free fatty acids theory: Primary existing capillary defects are reasonable caused by free fatty acids (FFA). They are hydrolyzed of the neutral fats and are histotoxic for the walls of the blood vessels.(ABSTRACT TRUNCATED AT 400 WORDS)


Asunto(s)
Embolia Grasa/etiología , Fracturas Óseas/complicaciones , Fijación Interna de Fracturas , Fijación Intramedular de Fracturas , Fracturas Óseas/cirugía , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo
14.
Aktuelle Traumatol ; 11(6): 210-6, 1981 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-6119881

RESUMEN

The indications of an arthrodesis of the knee joint have changed and seem to be rare in a century of total arthroplasty. However, even nowadays the arthrodesis of the knee joint is still carried out with good results in: postinfectious gonarthrosis, irreparable posttraumatic instability, Charcots knee, Neoplastic destructions in special cases, for patients with a severe painful and deforming arthrosis of any reason, which are too young for an arthroplasty and in a century of arthroplasty for all patients after failure of arthroplasty. Within a period of 11 years from 1969-1980, 105 patients underwent an arthrodesis of the knee joint at BG Unfallklinik Tübingen. Indications and technique are given, the value of an individual postoperative care is pointed out.


Asunto(s)
Artrodesis/métodos , Articulación de la Rodilla/cirugía , Adulto , Anciano , Artritis/cirugía , Artritis Infecciosa/cirugía , Clavos Ortopédicos , Placas Óseas , Femenino , Humanos , Traumatismos de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud
15.
Aktuelle Traumatol ; 14(2): 66-73, 1984 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-6144259

RESUMEN

Etiology, clinical manifestations, roentgenographic appearance and histological variations of solitary and aneurysmatic bone cyst are reported. The classification of solitary bone cyst into active and inactive cysts is important therefore prognosis and treatment are different. The critical control of our patients with fractured solitary and aneurysmatic bone cysts since 1973 resulted in a very contenting management of treatment. Active solitary bone cysts, recurrent cysts, fractured cysts and large cysts close to joints are treated by segmental resection, interposing of ribs, homologous or autogenous cancellous bone graft and plate osteosynthesis. We never found recidives under this treatment. The only curettage of active solitary bone cyst frequently is accompanied by recidive and unsatisfying functional results. Reports of local corticoid injections in treatment of bone cysts should be furthermore controlled critical.


Asunto(s)
Quistes Óseos/complicaciones , Fracturas Óseas/etiología , Fracturas Cerradas/etiología , Adolescente , Factores de Edad , Niño , Terapia Combinada , Femenino , Fracturas Cerradas/diagnóstico por imagen , Fracturas Cerradas/terapia , Humanos , Masculino , Radiografía
17.
Injury ; 40(7): 760-6, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19467654

RESUMEN

UNLABELLED: The aim of this study was to determine whether reamed or unreamed nailing is more harmful to local bone perfusion and increases fat occlusion of transcortical vessels. METHODS: After creating a standard fracture of the sheep tibia, reaming was performed in the first group using an experimental optimised reaming system (RE), in the second group with the conventional AO reamer (RC). Unreamed nailing was performed in the third group (UN). UHN 7.5mm titanium was inserted in all three groups. Intramedullary pressure was measured intraoperatively. Quantitative histological analyses of the bone were performed postoperatively. RESULTS: The highest fat occlusion of transcortical vessels occurred in UN (5.7%), the lowest in RE (1.6%). The least harm to intracortical circulation was caused by RE with 28% perfused intracortical vessels compared to 17% (UN) and 18% (RC). CONCLUSION: The experimental optimised reaming system reduces circulatory disturbance and local fat occlusion compared to the existing nailing procedures.


Asunto(s)
Embolia Grasa/fisiopatología , Fijación Intramedular de Fracturas/métodos , Curación de Fractura/fisiología , Tibia/irrigación sanguínea , Fracturas de la Tibia/cirugía , Animales , Clavos Ortopédicos , Embolia Grasa/etiología , Femenino , Fijación Intramedular de Fracturas/instrumentación , Modelos Animales , Presión/efectos adversos , Distribución Aleatoria , Flujo Sanguíneo Regional , Ovinos , Coloración y Etiquetado , Tibia/patología , Tibia/cirugía
18.
Z Orthop Unfall ; 146(3): 318-24, 2008.
Artículo en Alemán | MEDLINE | ID: mdl-18561076

RESUMEN

BACKGROUND: A generally accepted recommendation for the optimum surgical treatment of unstable, dislocated fractures of the proximal humerus is not yet available. According to the general surgical trend to minimally invasive techniques, the object of this study was to conduct follow-up examinations of the technique of minimally invasive T-plating at the proximal humerus developed at our hospital and to compare the results with those of other osteosynthetic techniques, especially concerning the complications of the surgical approach and the clinical outcome. PATIENTS AND METHOD: Between 1/2000 and 6/2003, 117 minimally invasive T-plating procedures were performed on 116 patients by sliding through a T-plate from a small proximal incision. After application of the exclusion criteria, a total of 100 operations on 99 patients were left. The follow-up examinations were based on the Constant score and the DASH score. RESULTS: At an average value of 70 points (SD +/- 21), the results of the Constant-Murley score were only medium to satisfactory (min. 17/max. 100 points). At an average value of 32 points (SD +/- 23), the results of the DASH score also were only adequate (min. 0/max. 78 points). A correlation between age, sex or fracture classification and the score results could not be deduced. CONCLUSION: The expectations for this technique were not met. Minimally invasive T-plating could not be shown to be superior to other techniques.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Curación de Fractura/fisiología , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Complicaciones Posoperatorias/etiología , Fracturas del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteonecrosis/diagnóstico por imagen , Osteonecrosis/etiología , Satisfacción del Paciente , Complicaciones Posoperatorias/diagnóstico por imagen , Radiografía , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Fracturas del Hombro/diagnóstico por imagen
19.
Artículo en Alemán | MEDLINE | ID: mdl-9574111

RESUMEN

The treatment of injuries in elderly patients requires thorough planning. Preexisting diseases and the current status determine the priorities and methods of treatment. The advantages of extensive preoperative assessment must be judged against the risks of a delay in undertaking operative measures. Fracture treatment aims at fast, careful and simple fixation, which is nevertheless stable and sufficient. Modern methods and implants allow acceptable results to be achieved, even under the limitations of modern health care systems.


Asunto(s)
Evaluación Geriátrica , Grupo de Atención al Paciente , Garantía de la Calidad de Atención de Salud , Heridas y Lesiones/cirugía , Anciano , Comorbilidad , Primeros Auxilios , Fracturas Óseas/clasificación , Fracturas Óseas/diagnóstico , Fracturas Óseas/cirugía , Alemania , Humanos , Traumatismo Múltiple/clasificación , Traumatismo Múltiple/diagnóstico , Traumatismo Múltiple/cirugía , Guías de Práctica Clínica como Asunto , Heridas y Lesiones/clasificación , Heridas y Lesiones/diagnóstico
20.
Artículo en Alemán | MEDLINE | ID: mdl-9101896

RESUMEN

Age-dependent wear, increasing proneness to injury during unsuitable activities and sudden falls caused by a general frailness are the reasons why the aged patient meets the joint surgeon. The desired treatment comprises different aims: painless and free motion, full weight-bearing capacity, avoidance of permanent nursing, facilitation of nursing. Adequate osteosynthetic techniques and the application of artificial joint replacement usually allow a fair restoration with early mobilisation and weight-bearing. The operative risks in the acute situation are higher than in elective surgery, while the long-term results of hip and knee replacements are very good.


Asunto(s)
Anciano Frágil , Artropatías/cirugía , Actividades Cotidianas/clasificación , Anciano , Anciano de 80 o más Años , Femenino , Fijación Interna de Fracturas , Evaluación Geriátrica , Indicadores de Salud , Prótesis de Cadera , Humanos , Artropatías/etiología , Artropatías/mortalidad , Prótesis de la Rodilla , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Rango del Movimiento Articular/fisiología , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda