Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(6): 1377-1383, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37222182

RESUMEN

INTRODUCTION: The risk of typical atrial flutter (AFL) is increased proportionately to right atrial (RA) size or right atrial scarring that results in reduced conduction velocity. These characteristics result in propagation of a flutter wave by ensuring the macro re-entrant wave front does not meet its refractory tail. The time taken to traverse the circuit would take account of both of these characteristics and may provide a novel marker of propensity to develop AFL. Our goal was to investigate right atrial collision time (RACT) as a marker of existing typical AFL. METHODS: This single-centre, prospective study recruited consecutive typical AFL ablation patients that were in sinus rhythm. Controls were consecutive electrophysiology study patients >18 years of age. While pacing the coronary sinus (CS) ostium at 600 ms, a local activation time map was created to locate the latest collision point on the anterolateral right atrial wall. This RACT is a measure of conduction velocity and distance from CS to a collision point on the lateral right atrial wall. RESULTS: Ninety-eight patients were included in the analysis, 41 with atrial flutter and 57 controls. Patients with atrial flutter were older, 64.7 ± 9.7 versus 52.4 ± 16.8 years (<.001), and more often male (34/41 vs. 31/57 [.003]). The AFL group mean RACT (132.6 ± 17.3 ms) was significantly longer than that of controls (99.1 ± 11.6 ms) (p < .001). A RACT cut-off of 115.5 ms had a sensitivity and specificity of 92.7% and 93.0%, respectively for diagnosis of atrial flutter. A ROC curve indicated an AUC of 0.96 (95% CI: 0.93-1.0, p < .01). CONCLUSION: RACT is a novel and promising marker of propensity for typical AFL. This data will inform larger prospective studies.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Humanos , Masculino , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Estudios Prospectivos , Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía
2.
Europace ; 21(3): 492-501, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30481301

RESUMEN

AIMS: Substrate based catheter ablation strategies are widely employed for treatment of scar-related ventricular tachycardia (VT). We analysed intracardiac electrograms (EGMs) from close-coupled paced extrastimuli extracted from the EnSite Precision mapping system. We sought to characterize EGM responses of ventricular myocardium to varying coupling intervals from the right ventricular apex (RVA) in both healthy individuals and patients presenting with VT for catheter ablation. METHODS AND RESULTS: Extrastimuli were delivered from the RVA after estimation of the ventricular effective refractory period. Electrograms were recorded from high-density mapping catheters in the left ventricle and exported for analysis to MATLAB. Observational data were collected from 14 patients with ischaemic VT (mean age 72.4 ± 6.3 years, one female) and five controls (mean age 59.4 ± 7.4 years, one female). These derived data were used to inform an interventional strategy on a further 10 patients (mean age 64.7 ± 10.0 years; two female). Significant differences were observed in EGM duration (ED) and latency (LT) at all coupling intervals between VT patients and controls. Significant increases in ED and LT with decreased RVA coupling interval were observed at VT isthmuses. Abnormal responses derived from control subject data were used to classify four types of ventricular EGM response. Targeting sites with abnormal LT and ED significantly reduced VT inducibility (5/14 derivation patients to 0/10 intervention patients; P = 0.03). CONCLUSION: Paced electrogram feature analysis is a novel tool to characterize the ischaemic substrate. Association with VT isthmuses and early ablation results suggest a possible role in substrate ablation for ischaemic VT.


Asunto(s)
Potenciales de Acción , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/diagnóstico , Función Ventricular Izquierda , Anciano , Estudios de Casos y Controles , Ablación por Catéter , Femenino , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Valor Predictivo de las Pruebas , Periodo Refractario Electrofisiológico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Factores de Tiempo
3.
Ann Noninvasive Electrocardiol ; 24(3): e12629, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30688396

RESUMEN

BACKGROUND: Current noninvasive risk stratification methods offer limited prediction of arrhythmic events when selecting patients for ICD implantation. Our laboratory has recently developed a signal processing metric called Layered Symbolic Decomposition frequency (LSDf) that quantifies the percentage of hidden QRS wave frequency components in signal-averaged ECG (SAECG) recordings. The purpose of this pilot study was to determine whether LSDf can be predictive of ventricular arrhythmia or death in an ICD patient cohort. METHODS AND RESULTS: Fifty-two ICD patients were recruited from 2008 to 2009. These were followed for a mean of 8.5 ± 0.4 years for the primary outcome of first appropriately treated ventricular arrhythmia (VT/VF) or death. Thirty-four subjects met the primary outcome. LSDf was significantly lower, and 12-lead QRS duration was significantly greater in patients meeting the primary outcome (12.14 ± 3.97% vs. 16.45 ± 3.73%; p = 0.001) and (111.59 ± 14.96 ms vs. 97.69 ± 13.51 ms; p = 0.012) respectively. A 13.25% LSDf threshold (0.74 sensitivity and 0.85 specificity) was selected based on an ROC curve. Kaplan-Meier survival analysis was conducted; patients above the 13.25% threshold demonstrated significantly better survival outcomes (log-rank p < 0.001). In Cox multivariate regression analysis, the LSDf threshold (13.25%) was compared to LVEF (28.5%), 12-lead QRSd (100 ms), age, % male sex, NYHA classification, and antiarrhythmic usage. LSDf was a predictor of the primary outcome (p = 0.005) and an independent predictor for solely ventricular arrhythmia (p = 0.002). CONCLUSION: Layered Symbolic Decomposition frequency analysis in SAECG recordings may be a viable predictor of negative ICD survival outcomes.


Asunto(s)
Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables/efectos adversos , Electrocardiografía/métodos , Procesamiento de Imagen Asistido por Computador , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Anciano , Área Bajo la Curva , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Selección de Paciente , Proyectos Piloto , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Curva ROC , Medición de Riesgo , Volumen Sistólico , Análisis de Supervivencia , Taquicardia Ventricular/mortalidad
4.
J Nurs Care Qual ; 34(4): 337-339, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30585983

RESUMEN

BACKGROUND: Between 2010 and 2012, the Heart Rhythm team in a tertiary care hospital completed a retrospective study that found that atrial fibrillation (AF) care can be episodic and heavily reliant on hospital resources, particularly the emergency department (ED). PROBLEM: Patients who attend the ED with AF are at high risk of hospital admission. APPROACH: A nurse practitioner (NP) was added to the Heart Rhythm team to create a program to improve AF care after an ED visit. Telephone practice was one of the many processes created. OUTCOMES: Findings revealed that 37 of 90 patients presented to the ED with AF prior to telephone contact and 7 of 90 patients did so post-telephone contact (P < .001). CONCLUSION: Telephone practice led by an NP provides an opportunity to improve assessment and management of patient with AF and offers a promising cost-effective method to reduce ED visits in the AF patient population.


Asunto(s)
Fibrilación Atrial/terapia , Servicio de Urgencia en Hospital/estadística & datos numéricos , Enfermeras Practicantes/normas , Telemedicina , Servicio de Urgencia en Hospital/economía , Femenino , Hospitales , Humanos , Masculino , Readmisión del Paciente/estadística & datos numéricos , Estudios Retrospectivos , Teléfono
5.
J Cardiovasc Electrophysiol ; 29(3): 421-434, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29316012

RESUMEN

BACKGROUND/OBJECTIVE: We compared health-related quality of life (HRQoL) in patients randomized to escalated therapy and those randomized to ablation for ventricular tachycardia in the VANISH trial. METHODS: HRQoL was assessed among VANISH patients at baseline and 3-, 6-, and 12-month follow-up visits. Four validated instruments were used: the SF-36, the implanted cardioverter defibrillator (ICD) Concerns questionnaire (ICDC), the Hospital Anxiety and Depression Scale (HADS), and the EuroQol five dimensions questionnaire (EQ-5D). Linear mixed-effects modeling was used for repeated measures with SF-36, HADS, ICDC, and EQ-5D as dependent variables. In a second model, treatment was subdivided by amiodarone use prior to enrollment. RESULTS: HRQoL did not differ significantly between those randomized to ablation or escalated therapy. On subgroup analysis, improvement in SF-36 measures was seen at 6 months in the ablation group for social functioning (63.5-69.3, P = 0.03) and energy/fatigue (43.0-47.9, P = 0.01). ICDC measures showed a reduction in ICD concern in the ablation group at 6 months (10.4-8.7, P = 0.01) and a reduction in ICD concern in the escalated therapy group at 6 months (10.9-9.4, P = 0.04). EQ-5D measures showed a significant improvement in overall health in ablation patients at 6 months (63.4-67.3, P = 0.04). CONCLUSION: Patients in the VANISH study randomized to ablation did not have a significant change in quality of life outcomes compared to those randomized to escalated therapy. Some subgroup findings were significant, as those randomized to ablation showed persistent improvement in SF-36 energy/fatigue and ICD concern, and transient improvement in SF-36 social functioning and EQ-5D overall health.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Ablación por Catéter , Calidad de Vida , Taquicardia Ventricular/terapia , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Ansiedad/diagnóstico , Ansiedad/prevención & control , Ansiedad/psicología , Australia , Ablación por Catéter/efectos adversos , Emociones , Europa (Continente) , Femenino , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Conducta Social , Encuestas y Cuestionarios , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/psicología , Factores de Tiempo , Resultado del Tratamiento
6.
Europace ; 17(1): 78-83, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25031236

RESUMEN

BACKGROUND: Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. AIMS: We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). METHODS AND RESULTS: This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P < 0.01) and the mean PPI - TCL was 330 ± 97 vs. 179 ± 103 ms (P < 0.01) for AT/AF and VT, respectively. Cut-offs of 615 ms for the PPI [area under curve (AUC) 0.93; 95% confidence interval (CI): 0.84-1.00; P < 0.01] and 260 ms for PPI - TCL (AUC 0.86; 95% CI: 0.74-0.98; P < 0.01) were identified. CONCLUSION: The PPI and PPI - TCL after failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs.


Asunto(s)
Desfibriladores Implantables , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Anciano , Fibrilación Atrial , Diagnóstico Diferencial , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Europace ; 17(8): 1289-93, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25672984

RESUMEN

AIMS: A significant proportion of patients develop atrial fibrillation (AF) following cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFl). The objective of this study was to assess whether the presence of advanced interatrial block (aIAB) was associated with an elevated risk of AF after CTI ablation in patients with typical AFl and no prior history of AF. METHODS AND RESULTS: This study included patients with typical AFl and no prior history of AF that were referred for CTI ablation. Patients were excluded when they had received repeat ablations or did not demonstrate a bidirectional block. In all patients, a post-ablation electrocardiogram (ECG) in sinus rhythm was evaluated for the presence of aIAB, defined as a P-wave duration ≥120 ms and biphasic morphology in the inferior leads. New-onset AF was identified from 12-lead ECGs, Holter monitoring, and device interrogations. The cohort comprised 187 patients (age 67 ± 10.7 years; ejection fraction 55.8 ± 11.2%). Advanced interatrial block was detected in 18.2% of patients, and left atrium was larger in patients with aIAB compared with those without aIAB (46.2 ± 5.9 vs. 43.1 ± 6.0 mm; P = 0.01). Over a median follow-up of 24.2 months, 67 patients (35.8%) developed new-onset AF. The incidence of new-onset AF was greater in patients with aIAB compared with those without aIAB (64.7 vs. 29.4%; P < 0.001). After a comprehensive multivariate analysis, aIAB emerged as the strongest predictor of new-onset AF [odds ratio (OR) 4.2, 95% confidence interval (CI): 1.9-9.3; P < 0.001]. CONCLUSION: Advanced interatrial block is a key predictor for high risk of new-onset AF after a successful CTI ablation in patients with typical AFl.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrocardiografía/métodos , Atrios Cardíacos/cirugía , Bloqueo Cardíaco/diagnóstico , Sistema de Conducción Cardíaco/cirugía , Anciano , Fibrilación Atrial/complicaciones , Diagnóstico Diferencial , Femenino , Bloqueo Cardíaco/etiología , Humanos , Masculino , Recurrencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Insuficiencia del Tratamiento , Resultado del Tratamiento
8.
Ann Noninvasive Electrocardiol ; 20(4): 394-6, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25201217

RESUMEN

Interatrial conduction disorders are frequent in patients with structural heart diseases, including hypertension, coronary disease, and hypertrophic cardiomyopathy, and they are strongly associated with atrial tachyarrhythmias, especially atrial fibrillation and flutter. Conduction delays lead to dispersion of refractory periods and participate in initiating and maintaining reentry circuits, facilitating atrial arrhythmias. In this case, the changing pattern over time is a manifestation of progressive atrial remodeling and conduction delay. The terminal negative component of the P wave in the inferior leads suggests block of the electrical impulse in the Bachman bundle zone, with retrograde activation of the left atria via muscular connections at the coronary sinus. This has been reproduced in experimental models and confirmed by endocardial mapping. Physicians should be aware of the association between advanced interatrial block and development of atrial arrhythmias as its recognition could prompt early and aggressive antiarrhythmic treatment.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Electrocardiografía , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/anomalías , Arritmias Cardíacas/complicaciones , Fibrilación Atrial/complicaciones , Aleteo Atrial/complicaciones , Síndrome de Brugada , Trastorno del Sistema de Conducción Cardíaco , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Taquicardia/complicaciones
9.
Pacing Clin Electrophysiol ; 37(1): 73-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23980900

RESUMEN

BACKGROUND: Frequent idiopathic premature ventricular contractions (PVCs) have been associated with left ventricular cardiomyopathy. Idiopathic PVCs often originate from the right ventricular outflow tract (RVOT), and radiofrequency catheter ablation (RFCA) is being used as a treatment to alleviate symptoms. A meta-analysis was performed to evaluate RFCA for the treatment of frequent idiopathic PVCs on heart function. METHODS AND RESULTS: A literature search was conducted using Medline and Embase to identify studies evaluating the effects of RFCA as treatment for PVCs originating from the RVOT. Articles were chosen if they reported the effect of RFCA on the quantity of PVCs or ventricular function. Only studies in English were included. Articles were excluded if they did not separate results for PVCs originating from areas other than the RVOT. A total of 450 articles were retrieved from electronic searches, and 14 articles were included in this systematic review. Six of these were meta-analyzed (N = 70) and showed a reduction in the total number of PVCs in 24 hours after RFCA by a mean of -30089.44 confidence interval [CI]: -31658.47, -28520.40, P < 0.00001). Left ventricular ejection fraction (LVEF) was reported in five of the 14 studies, which included 108 patients. RFCA significantly improved LVEF by a mean of 10.36 (CI: 8.75, 11.97, P < 0.00001) in patients with frequent PVCs from the RVOT. The remaining studies reported their results differently and were not included in the meta-analyses but were described separately. CONCLUSIONS: RFCA reduces the number of PVCs and improves the cardiac function in patients with idiopathic frequent PVCs originating from the RVOT.


Asunto(s)
Ablación por Catéter/estadística & datos numéricos , Obstrucción del Flujo Ventricular Externo/epidemiología , Obstrucción del Flujo Ventricular Externo/prevención & control , Complejos Prematuros Ventriculares/epidemiología , Complejos Prematuros Ventriculares/cirugía , Humanos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico , Complejos Prematuros Ventriculares/diagnóstico
10.
Ann Noninvasive Electrocardiol ; 19(1): 50-6, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24460806

RESUMEN

BACKGROUND: Cyclooxygenase-2 inhibitors, the newest class of nonsteroidal antiinflammatories, pose an increased risk of adverse cardiovascular events, in particular atrial fibrillation (AF). We hypothesized that the COX-2 inhibitor celecoxib alters atrial electrophysiology, and thus promotes the development of AF. METHODS: Three prospective patient cohorts were created: Healthy patients (n = 35), inflammatory arthritis patients with no celecoxib use (n = 22), and inflammatory arthritis patients treated with celecoxib (n = 20). Patients were included in the arthritis cohorts if they were over the age of 18 and had a diagnosis of inflammatory arthritis. Patients in the celecoxib group must be actively treated with celecoxib for more than 2 months. Patients were excluded if they were taking antiarrhythmic mediation, had a diagnosis of AF, refractory hypertension, or congestive heart failure. High-resolution signal-averaged electrocardiogram was recorded and P-wave duration (PWD) was derived. RESULTS: PWD was significantly longer in inflammatory arthritis patients treated with celecoxib, compared to both healthy and inflammatory arthritis patients (P = 0.049, P = 0.036). There was no difference in the PWD of healthy patients as compared to inflammatory arthritis patients (P = 0.916). Mean PWD (standard error of the mean) of the inflammatory arthritis patients treated with celecoxib was 133.1 (2.7) ms as compared to 125.3 (1.6) ms in the healthy patients and 124.0 (2.9) ms in the inflammatory arthritis patients. CONCLUSIONS: Given that PWD is a well-accepted noninvasive marker of atrial electrophysiology, our results suggest that these patients demonstrate adverse atrial remodeling predisposing to atrial arrhythmia.


Asunto(s)
Artritis/tratamiento farmacológico , Fibrilación Atrial/inducido químicamente , Inhibidores de la Ciclooxigenasa 2/efectos adversos , Electrocardiografía/efectos de los fármacos , Pirazoles/efectos adversos , Sulfonamidas/efectos adversos , Análisis de Varianza , Celecoxib , Estudios de Cohortes , Inhibidores de la Ciclooxigenasa 2/uso terapéutico , Electrocardiografía/métodos , Electrocardiografía/estadística & datos numéricos , Femenino , Atrios Cardíacos/efectos de los fármacos , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pirazoles/uso terapéutico , Sulfonamidas/uso terapéutico
11.
Ann Noninvasive Electrocardiol ; 19(1): 23-33, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24112475

RESUMEN

INTRODUCTION: In patients with normal hearts, increased vagal tone is associated with onset of paroxysmal atrial fibrillation (AF). Vagal denervation of the atria renders AF less inducible. Circumferential pulmonary vein isolation (CPVI) is effective for treating paroxysmal and persistent AF, and has been shown to impact heart rate variability (HRV) indices, in turn, reflecting vagal denervation. We examined the impact of CPVI on HRV indices, and evaluated the relationship between vagal modification and AF recurrence. METHODS: Electrocardiogram recordings were collected from 83 consecutive patients (63 male, 20 female, age 56.9 ± 9.3 years) undergoing CPVI for paroxysmal (n = 56) or persistent (n = 27) AF. Recordings were obtained over 10 minutes preprocedure, and at intervals up to 12 months. Antiarrhythmic medications were suspended prior to CPVI, and were resumed for 3 months following. Success was defined as no recurrence of atrial arrhythmia lasting longer than 30 seconds. RESULTS: In patients with successful procedures (n = 56, 42 paroxysmal, 14 persistent), HRV indices were significantly altered, with respect to preprocedure levels, over a sustained period. However, patients with recurrence (n = 27, 14 paroxysmal, 13 persistent) demonstrated similar HRV to their preprocedure levels over the follow-up period. CONCLUSION: Our results suggest that patients experiencing recurrence after a single CPVI have HRV attenuated by the procedure only intermittently, whereas patients with one successful CPVI experience a sustained change. A short-term HRV recording is a convenient and potentially important marker for recurrence of atrial arrhythmia in a population undergoing CPVI.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Frecuencia Cardíaca/fisiología , Venas Pulmonares/cirugía , Fibrilación Atrial/fisiopatología , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Prevención Secundaria , Resultado del Tratamiento
12.
Europace ; 15(3): 447-52, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23154844

RESUMEN

AIMS: Catheter ablation for paroxysmal atrial fibrillation (AF) is rapidly becoming a standard practice. There is literature to support that catheter ablation of persistent AF requires additional 'substrate modification'. In clinical practice, operators rely on automated fractionation maps created by three-dimensional anatomic mapping systems to rapidly assess complex 'fractionated' signals (CFAE). These systems use differing algorithms to automate the process. The agreement between operators and contemporary algorithms has not been examined. We sought to assess the agreement between operators and a novel method of quantification calculating percentage fractionation (PF). METHODS AND RESULTS: Expert opinion on 80 atrial electrogram 4 s signals of varying levels of activity were gathered and pooled for comparison. Twelve independent experts visually quantified the signal fractionation and offered a threshold level for ablation. We developed an algorithm to find sites with high continuous electrical activity, or high PF. Correlation between experts and PF was 0.78 [P < 0.01, 95% confidence interval (CI) (0.68-0.86)]. Receiver operating characteristics curve sensitivity and specificity for PF were 0.7727 and 0.8103 at the optimal cut-off point of 58.45 PF with area under curve 0.89 CI (0.80-0.99). CONCLUSION: The PF statistic represents a more robust and intuitive measure to represent fractionated atrial activity; importantly it demonstrates excellent agreement with expert users and presents a new standard for algorithm assessment. Use of a PF statistic should be considered in automated mapping systems.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Procesamiento de Señales Asistido por Computador , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Automatización , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
13.
Ann Noninvasive Electrocardiol ; 18(1): 79-83, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23347030

RESUMEN

We present a series of three cases of patch testing confirmed cardiac rhythm device induced contact dermatitis. In the first two cases, there was complete resolution with device extraction and reimplantation with another device with either an absence of the offending agent or a coating with another resin or metal. These cases illustrate the difficulties in diagnosing pain, tenderness, and dermatological manifestations in patients with cardiac rhythm devices (pacemakers and implantable cardioverter defibrillators).


Asunto(s)
Dermatitis por Contacto/diagnóstico , Dermatitis por Contacto/etiología , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas del Parche
14.
IEEE Trans Biomed Eng ; PP2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38060362

RESUMEN

Sequential local activation time (LAT) mapping of intracardiac electrograms' activations requires a stable reference signal to align recording phases. OBJECTIVE: This work's purpose is to develop an LAT mapping approach that does not rely on a time-alignment reference (TAR). METHODS: To create an LAT map in absence of TAR (TARLess), the coordinates and LATs of recording electrodes are collected sequentially; a bank of candidate functions (CFs) is constructed that contains constant binary level CFs and non-linear functions of recording points' coordinates. Finally, a subset of CFs is linearly combined to create an activation time function with output matching electrodes' LATs. Synthetic and clinical data were deployed to validate TARLess. A simple two-dimensional computer model was used to create 30 different wavefront collision scenarios in a region with spatial conduction heterogeneities. Furthermore, sequential recordings were collected from seven atrial fibrillation patients during stimulation from one or two sites, after sinus rhythm was achieved post catheter ablation. RESULTS: We showed that TARLess maps are similar to the one that uses TAR; for the 20 clinical maps, the mean absolute difference between measured LAT with the TAR and TARLess approach was 5.2 ±2.0 milliseconds. CONCLUSION: We developed a novel method to create an LAT map of sequential recordings without using any TAR and showed that it can create accurate maps even during the collision of multiple wavefronts. SIGNIFICANCE: TARLess mapping does not require a reference catheter which could lead to reduction in ablation procedure duration, cost, and potential complications.

15.
J Cardiovasc Electrophysiol ; 23(4): 370-4, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22049976

RESUMEN

UNLABELLED: Cardiac resynchronization therapy (CRT) benefits selected heart failure (HF) patients. The optimal placement of the right ventricle (RV) lead during biventricular pacing has not been assessed. Greater electrical separation (ES) between left ventricle (LV) and RV leads has been associated with better clinical outcomes. The site of maximal electrical separation(MES) in the RV is unknown. METHODS: Prospective study of 50 CRT patients. The LV lead was placed in a postero-lateral branch of the coronary sinus. ES was recorded at 6 sites within the RV during LV pacing at 600 milliseconds cycle length (CL). The median ES was recorded with a roving deflectable catheter at the RV outflow tract (RVOT), high septum, inflow septum, mid-septum, apical septum and apex. RESULTS: Mean age was 67 ± 7 years, 39 were male (78%). Thirty had ischemic etiology (60%). Mean left ventricular ejection fraction (LVEF) was 25 ± 7%, QRS duration pre and post was 165 ± 26 milliseconds and 138.5 ± 15.6 milliseconds (P < 0.001). Mapping ES showed a difference between 20 and 50 milliseconds distributed across the RV in the majority of patients (40/49). However, 7 subjects demonstrated delay distribution of between 50 and 82 milliseconds. ES was significant greater in the RV mid-septum (161.2 ± 23.7 milliseconds) compared with RVOT (154.1 ± 20.8 milliseconds) and apex (148.0 ± 25.5 milliseconds; P < 0.001). The site of Maximal ES was most commonly found at the mid-septum (40 patients, 80%) and only rarely at the RVOT (5, 10%) and apex (5, 10%; P < 0.01). CONCLUSION: MES was observed most commonly at the RV septum and rarely at the RV apex. Better correction of electrical and mechanical dyssynchrony by CRT may be achieved by placing the RV lead in a site outside of the apex in the majority of patients. Clinical studies exploring RV septal pacing in CRT seem warranted.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Potenciales de Acción , Anciano , Cateterismo Cardíaco , Terapia de Resincronización Cardíaca/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Ontario , Estudios Prospectivos , Recuperación de la Función , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Tabique Interventricular/fisiopatología
16.
Europace ; 13(8): 1174-9, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21561903

RESUMEN

AIMS: Sleep apnoea (SA) is a common problem among congestive heart failure (CHF) patients. Evidence has shown that cardiac resynchronization therapy (CRT) reduces morbidity and mortality associated with CHF. The aim of this paper was to review studies evaluating the reduction of the Apnoea-Hypopnoea Index (AHI) in patients with SA after treatment with CRT and to perform a meta-analysis to estimate the true effect of CRT on SA. METHODS AND RESULTS: A systematic electronic literature search was conducted in Medline and Embase to identify studies reporting on the effects of CRT on SA. A hand search of five major cardiology societies was performed to identify any unpublished studies through structured abstracts submitted to conference proceedings. To be eligible for inclusion, studies had to include a comparison of CRT vs. no pacing and use AHI as an outcome. Non-English studies were excluded. Nine manuscripts and five abstracts were identified for review. Six manuscripts and three abstracts were included in meta-analysis, which included 170 patients. After treatment with CRT, a significant reduction in AHI was found in patients with central sleep apnoea (CSA) with a mean reduction of -13.05 (CI -16.74 to -9.36; P < 0.00001) but not in patients with obstructive sleep apnoea (13.32; CI -9.04 to 2.39; P = 0.25). CONCLUSION: Cardiac resynchronization therapy reduces the severity of SA. Major effects are seen in patients with CSA. The presence of SA may be an additional consideration when deciding on which heart failure patients will receive CRT.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Síndromes de la Apnea del Sueño/etiología , Síndromes de la Apnea del Sueño/terapia , Función Atrial/fisiología , Humanos , Resultado del Tratamiento
17.
J Comp Physiol B ; 191(6): 1071-1083, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34304289

RESUMEN

Advances in implantable radio-telemetry or diverse biologging devices capable of acquiring high-resolution ambulatory electrocardiogram (ECG) or heart rate recordings facilitate comparative physiological investigations by enabling detailed analysis of cardiopulmonary phenotypes and responses in vivo. Two priorities guiding the meaningful adoption of such technologies are: (1) automation, to streamline and standardize large dataset analysis, and (2) flexibility in quality-control. The latter is especially relevant when considering the tendency of some fully automated software solutions to significantly underestimate heart rate when raw signals contain high-amplitude noise. We present herein moving average and standard deviation thresholding (MAST), a novel, open-access algorithm developed to perform automated, accurate, and noise-robust single-channel R-wave detection from ECG obtained in chronically instrumented mice. MAST additionally and automatically excludes and annotates segments where R-wave detection is not possible due to artefact levels exceeding signal levels. Customizable settings (e.g. window width of moving average) allow for MAST to be scaled for use in non-murine species. Two expert reviewers compared MAST's performance (true/false positive and false negative detections) with that of a commercial ECG analysis program. Both approaches were applied blindly to the same random selection of 270 3-min ECG recordings from a dataset containing varying amounts of signal artefact. MAST exhibited roughly one quarter the error rate of the commercial software and accurately detected R-waves with greater consistency and virtually no false positives (sensitivity, Se: 98.48% ± 4.32% vs. 94.59% ± 17.52%, positive predictivity, +P: 99.99% ± 0.06% vs. 99.57% ± 3.91%, P < 0.001 and P = 0.0274 respectively, Wilcoxon signed rank; values are mean ± SD). Our novel, open-access approach for automated single-channel R-wave detection enables investigators to study murine heart rate indices with greater accuracy and less effort. It also provides a foundational code for translation to other mammals, ectothermic vertebrates, and birds.


Asunto(s)
Electrocardiografía , Procesamiento de Señales Asistido por Computador , Algoritmos , Animales , Corazón , Frecuencia Cardíaca , Ratones
18.
J Am Heart Assoc ; 10(1): e016071, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33381975

RESUMEN

Background Patients with persistent atrial fibrillation (AF) undergoing catheter-based AF ablation have lower success rates than those with paroxysmal AF. We compared healthcare use and clinical outcomes between patients according to their AF subtypes. Methods and Results Consecutive patients undergoing AF ablation were prospectively identified from a population-based registry in Ontario, Canada. Via linkage with administrative databases, we performed a retrospective analysis comparing the following outcomes between patients with persistent and paroxysmal AF: healthcare use (defined as AF-related hospitalizations/emergency room visits), periprocedural complications, and mortality. Multivariable Poisson modeling was performed to compare the rates of AF-related and all-cause hospitalizations/emergency room visits in the year before versus after ablation. Between April 2012 and March 2016, there were 3768 consecutive patients who underwent first-time AF ablation, of whom 1040 (27.6%) had persistent AF. The mean follow-up was 1329 days. Patients with persistent AF had higher risk of AF-related hospitalization/emergency room visits (hazard ratio [HR], 1.21; 95% CI, 1.09-1.34), mortality (HR, 1.74; 95% CI, 1.15-2.63), and periprocedural complications (odds ratio, 1.36; 95% CI, 1.02-1.75) than those with paroxysmal AF. In the overall cohort, there was a 48% reduction in the rate of AF-related hospitalization/emergency room visits in the year after versus before ablation (rate ratio [RR], 0.52; 95% CI, 0.48-0.56). This reduction was observed for patients with paroxysmal (RR, 0.45; 95% CI, 0.41-0.50) and persistent (RR, 0.74; 95% CI, 0.63-0.87) AF. Conclusions Although patients with persistent AF had higher risk of adverse outcomes than those with paroxysmal AF, ablation was associated with a favorable reduction in downstream AF-related healthcare use, irrespective of AF type.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Servicio de Urgencia en Hospital/estadística & datos numéricos , Hospitalización/estadística & datos numéricos , Complicaciones Posoperatorias , Fibrilación Atrial/clasificación , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ontario/epidemiología , Evaluación de Procesos y Resultados en Atención de Salud , Aceptación de la Atención de Salud/estadística & datos numéricos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Recurrencia , Sistema de Registros/estadística & datos numéricos , Reoperación/estadística & datos numéricos , Estudios Retrospectivos
19.
Europace ; 12(6): 908-9, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20207745

RESUMEN

We present a 45-year-old woman with supraventricular tachycardia. During placement of diagnostic catheters, an interruption of the inferior vena cava was suspected. An MRI confirmed the interruption of the inferior vena cava above the level of the renal veins with azygos vein continuation up to the superior vena cava. Catheter ablation was performed using a superior approach via the left subclavian vein.


Asunto(s)
Vena Ácigos/anomalías , Ablación por Catéter/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Vena Cava Inferior/anomalías , Vena Ácigos/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Vena Subclavia , Taquicardia por Reentrada en el Nodo Atrioventricular/patología , Vena Cava Inferior/patología
20.
Europace ; 12(11): 1550-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20716548

RESUMEN

AIMS: The practice of routine vs. selective transoesophageal echocardiography (TEE) surveillance for left atrial appendage or intracavitary thrombus prior to pulmonary vein isolation (PVI) varies widely as evidence to guide this decision in terms of important clinical outcomes is lacking. METHODS AND RESULTS: We constructed a decision analysis model to compare the cost-effectiveness of routine TEE for detection of left atrial thrombus vs. no TEE. The model incorporated health outcomes and costs. Markov methodology was used to follow patients as they transition through varying health states. We examined a hypothetical cohort of patients with symptomatic atrial fibrillation suitable for PVI, and expected outcomes were modelled over a period of 2 years. Simulated patients (SPs) undergoing a strategy of a routine TEE experienced significantly fewer transient ischemic attacks (TIAs) [OR 0.28 (0.22-0.37)], and debilitating strokes [OR 0.23 (0.15-0.33)]. Routine TEE led to an absolute risk reduction for stroke of 1.2% [number needed to treat (NNT) 84 (79-100)] and 1.9% for TIA [NNT 53 (48-59)]. The incremental cost-effectiveness ratio (ICER) for TEE was $226,608 per quality-adjusted life year (QALY). The ICER for TEE among high-risk SPs, with pre-existing clot in the left atrium, was $2232 per QALY. CONCLUSION: Decision analysis and microsimulation suggest that routine use of TEE in an unselected population prior to PVI lowers the incidence of cerebral thrombo-embolic events but with considerable cost per QALY.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/economía , Ecocardiografía Transesofágica/economía , Ataque Isquémico Transitorio/epidemiología , Venas Pulmonares/cirugía , Accidente Cerebrovascular/epidemiología , Estudios de Cohortes , Simulación por Computador , Análisis Costo-Beneficio , Técnicas de Apoyo para la Decisión , Humanos , Cadenas de Markov , Calidad de Vida , Años de Vida Ajustados por Calidad de Vida , Trombosis/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda