Eur Radiol ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046499

RESUMEN

OBJECTIVES: To perform a multi-reader comparison of multiparametric dual-energy computed tomography (DECT) images reconstructed with deep-learning image reconstruction (DLIR) and standard-of-care adaptive statistical iterative reconstruction-V (ASIR-V). METHODS: This retrospective study included 100 patients undergoing portal venous phase abdominal CT on a rapid kVp switching DECT scanner. Six reconstructed DECT sets (ASIR-V and DLIR, each at three strengths) were generated. Each DECT set included 65 keV monoenergetic, iodine, and virtual unenhanced (VUE) images. Using a Likert scale, three radiologists performed qualitative assessments for image noise, contrast, small structure visibility, sharpness, artifact, and image preference. Quantitative assessment was performed by measuring attenuation, image noise, and contrast-to-noise ratios (CNR). For the qualitative analysis, Gwet's AC2 estimates were used to assess agreement. RESULTS: DECT images reconstructed with DLIR yielded better qualitative scores than ASIR-V images except for artifacts, where both groups were comparable. DLIR-H images were rated higher than other reconstructions on all parameters (p-value < 0.05). On quantitative analysis, there was no significant difference in the attenuation values between ASIR-V and DLIR groups. DLIR images had higher CNR values for the liver and portal vein, and lower image noise, compared to ASIR-V images (p-value < 0.05). The subgroup analysis of patients with large body habitus (weight ≥ 90 kg) showed similar results to the study population. Inter-reader agreement was good-to-very good overall. CONCLUSION: Multiparametric post-processed DECT datasets reconstructed with DLIR were preferred over ASIR-V images with DLIR-H yielding the highest image quality scores. CLINICAL RELEVANCE STATEMENT: Deep-learning image reconstruction in dual-energy CT demonstrated significant benefits in qualitative and quantitative image metrics compared to adaptive statistical iterative reconstruction-V. KEY POINTS: Dual-energy CT (DECT) images reconstructed using deep-learning image reconstruction (DLIR) showed superior qualitative scores compared to adaptive statistical iterative reconstruction-V (ASIR-V) reconstructed images, except for artifacts where both reconstructions were rated comparable. While there was no significant difference in attenuation values between ASIR-V and DLIR groups, DLIR images showed higher contrast-to-noise ratios (CNR) for liver and portal vein, and lower image noise (p value < 0.05). Subgroup analysis of patients with large body habitus (weight ≥ 90 kg) yielded similar findings to the overall study population.

2.
Eur Radiol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38967660

RESUMEN

PURPOSE: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT). METHODS: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images. RESULTS: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%). CONCLUSION: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses. CLINICAL RELEVANCE STATEMENT: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice. KEY POINTS: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

3.
Eur Radiol ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38913243

RESUMEN

OBJECTIVES: To establish normative values and identify potential factors influencing pancreatic iodine uptake using dual-energy CT (DECT). MATERIALS AND METHODS: This retrospective study included participants without pancreatic diseases undergoing DECT at two institutions with different platforms. Their protocols both included arterial phase (AP), portal venous phase (PP), and equilibrium phase (EP), defined as 35 s-40 s, 60 s-70 s, and 150 s-180 s after injection of contrast agent, respectively. Both iodine concentration (IC) and normalised IC (NIC) were measured. Demographic features, local measurements of the pancreas and visceral fat area (VFA) were considered as potential factors influencing iodine uptake using multivariate linear regression analyses. RESULTS: A total of 562 participants (median age 58 years [interquartile range: 47-67], with 282 men) were evaluated. The mean IC differed significantly between two institutions (all p < 0.001) across three contrast-enhanced phases, while the mean NIC showed no significant differences (all p > 0.05). The mean values of NIC were 0.22 at AP, 0.43 at PP and 0.45 at EP. NICAP was independently affected by VFA (ß = 0.362, p < 0.001), smoking (ß = -0.240, p = 0.001), and type-II diabetes (ß = -0.449, p < 0.001); NICPP by VFA (ß = -0.301, p = 0.017) and smoking (ß = -0.291, p < 0.001); and NICEP by smoking (ß = -0.154, p = 0.10) and alcohol consumption (ß = -0.350, p < 0.001) with statistical power values over 0.81. CONCLUSION: NIC values were consistent across institutions. Abdominal obesity, smoking, alcohol consumption, and diabetes are independent factors influencing pancreatic iodine uptake. CLINICAL RELEVANCE STATEMENT: This study has provided reference normative values, influential factors and effective normalisation methods of pancreatic iodine uptake in multiphase dual-energy CT for future studies in this area as a new biological marker. KEY POINTS: Evaluation of pancreatic iodine uptake measured by dual-energy CT is a promising method for future studies. Abdominal obesity, smoking, alcohol consumption, diabetes, and sex are independent factors influencing pancreatic iodine uptake. Utility of normalised iodine concentration is necessary to ensure the consistency across different institutions.

4.
BMC Med Imaging ; 24(1): 245, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39285354

RESUMEN

OBJECTIVE: To evaluate the prediction value of Dual-energy CT (DECT)-based quantitative parameters and radiomics model in preoperatively predicting muscle invasion in bladder cancer (BCa). MATERIALS AND METHODS: A retrospective study was performed on 126 patients with BCa who underwent DECT urography (DECTU) in our hospital. Patients were randomly divided into training and test cohorts with a ratio of 7:3. Quantitative parameters derived from DECTU were identified through univariate and multivariate logistic regression analysis to construct a DECT model. Radiomics features were extracted from the 40, 70, 100 keV and iodine-based material-decomposition (IMD) images in the venous phase to construct radiomics models from individual and combined images using a support vector machine classifier, and the optimal performing model was chosen as the final radiomics model. Subsequently, a fusion model combining the DECT parameters and the radiomics model was established. The diagnostic performances of all three models were evaluated through receiver operating characteristic (ROC) curves and the clinical usefulness was estimated using decision curve analysis (DCA). RESULTS: The normalized iodine concentration (NIC) in DECT was an independent factor in diagnosing muscle invasion of BCa. The optimal multi-image radiomics model had predictive performance with an area-under-the-curve (AUC) of 0.867 in the test cohort, better than the AUC = 0.704 with NIC. The fusion model showed an increased level of performance, although the difference in AUC (0.893) was not statistically significant. Additionally, it demonstrated superior performance in DCA. For lesions smaller than 3 cm, the fusion model showed a high predictive capability, achieving an AUC value of 0.911. There was a slight improvement in model performance, although the difference was not statistically significant. This improvement was observed when comparing the AUC values of the DECT and radiomics models, which were 0.726 and 0.884, respectively. CONCLUSION: The proposed fusion model combing NIC and the optimal multi-image radiomics model in DECT showed good diagnostic capability in predicting muscle invasiveness of BCa.


Asunto(s)
Invasividad Neoplásica , Tomografía Computarizada por Rayos X , Neoplasias de la Vejiga Urinaria , Humanos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patología , Masculino , Femenino , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Anciano , Persona de Mediana Edad , Invasividad Neoplásica/diagnóstico por imagen , Biopsia , Anciano de 80 o más Años , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Curva ROC , Adulto , Radiómica
5.
Skeletal Radiol ; 53(11): 2333-2345, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38587617

RESUMEN

Recent advances in computed tomography have resulted in new applications of CT scans in musculoskeletal imaging. Dual-energy CT technology involves the acquisition of data at high and low kilovolts, allowing differentiation and quantification of materials with different X-ray absorption. Newer CT scanners with a variety of post-processing options allow interesting applications of dual-energy CT in musculoskeletal and trauma imaging. This article provides an overview of the basic principles and physics of DECT. We review applications of DECT in the evaluation of the acute painful joint with suspicion of gout, metal artefact reduction in the prosthetic joint and in imaging of patients following major trauma. We present a review of literature and case examples to illustrate the strengths and limitations of this modality in the diagnosis of acute musculoskeletal conditions.


Asunto(s)
Enfermedades Musculoesqueléticas , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Heridas y Lesiones/diagnóstico por imagen , Enfermedad Aguda , Sistema Musculoesquelético/diagnóstico por imagen , Sistema Musculoesquelético/lesiones
6.
Skeletal Radiol ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38833168

RESUMEN

OBJECTIVE: This study aimed to quantitatively assess the diagnostic value of bone marrow edema (BME) detection on virtual non-calcium (VNCa) images calculated from dual-energy CT (DECT) in people with diabetes mellitus and suspected Charcot neuro-osteoarthropathy (CN). MATERIALS AND METHODS: People with diabetes mellitus and suspected CN who underwent DECT of the feet (80kVp/Sn150kVp) were included retrospectively. Two blinded observers independently measured CT values on VNCa images using circular regions of interest in five locations in the midfoot (cuneiforms, cuboid and navicular) and the calcaneus of the contralateral or (if one foot was available) the ipsilateral foot. Two clinical groups were formed, one with active CN and one without active CN (no-CN), based on the clinical diagnosis. RESULTS: Thirty-two people with diabetes mellitus and suspected CN were included. Eleven had clinically active CN. The mean CT value in the midfoot was significantly higher in the CN group (-55.6 ± 18.7 HU) compared to the no-CN group (-94.4 ± 23.5 HU; p < 0.001). In the CN group, the difference in CT value between the midfoot and calcaneus was statistically significant (p = 0.003); this was not the case in the no-CN group (p = 0.357). The overall observer agreement was good for the midfoot (ICC = 0.804) and moderate for the calcaneus (ICC = 0.712). Sensitivity was 100.0% and specificity was 71.4% using a cutoff value of -87.6 HU. CONCLUSION: The detection of BME on VNCa images has a potential value in people with diabetes mellitus and suspected active CN.

7.
Skeletal Radiol ; 53(9): 1711-1725, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38969781

RESUMEN

Computed tomography (CT) is a common modality employed for musculoskeletal imaging. Conventional CT techniques are useful for the assessment of trauma in detection, characterization and surgical planning of complex fractures. CT arthrography can depict internal derangement lesions and impact medical decision making of orthopedic providers. In oncology, CT can have a role in the characterization of bone tumors and may elucidate soft tissue mineralization patterns. Several advances in CT technology have led to a variety of acquisition techniques with distinct clinical applications. These include four-dimensional CT, which allows examination of joints during motion; cone-beam CT, which allows examination during physiological weight-bearing conditions; dual-energy CT, which allows material decomposition useful in musculoskeletal deposition disorders (e.g., gout) and bone marrow edema detection; and photon-counting CT, which provides increased spatial resolution, decreased radiation, and material decomposition compared to standard multi-detector CT systems due to its ability to directly translate X-ray photon energies into electrical signals. Advanced acquisition techniques provide higher spatial resolution scans capable of enhanced bony microarchitecture and bone mineral density assessment. Together, these CT acquisition techniques will continue to play a substantial role in the practices of orthopedics, rheumatology, metabolic bone, oncology, and interventional radiology.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Sistema Musculoesquelético/diagnóstico por imagen
8.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386967

RESUMEN

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Obesidad , Hierro
9.
J Appl Clin Med Phys ; 25(5): e14340, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38605540

RESUMEN

BACKGROUND: Global shortages of iodinated contrast media (ICM) during COVID-19 pandemic forced the imaging community to use ICM more strategically in CT exams. PURPOSE: The purpose of this work is to provide a quantitative framework for preserving iodine CNR while reducing ICM dosage by either lowering kV in single-energy CT (SECT) or using lower energy virtual monochromatic images (VMI) from dual-energy CT (DECT) in a phantom study. MATERIALS AND METHODS: In SECT study, phantoms with effective diameters of 9.7, 15.9, 21.1, and 28.5 cm were scanned on SECT scanners of two different manufacturers at a range of tube voltages. Statistical based iterative reconstruction and deep learning reconstruction were used. In DECT study, phantoms with effective diameters of 20, 29.5, 34.6, and 39.7 cm were scanned on DECT scanners from three different manufacturers. VMIs were created from 40 to 140 keV. ICM reduction by lowering kV levels for SECT or switching from SECT to DECT was calculated based on the linear relationship between iodine CNR and its concentration under different scanning conditions. RESULTS: On SECT scanner A, while matching CNR at 120 kV, ICM reductions of 21%, 58%, and 72% were achieved at 100, 80, and 70 kV, respectively. On SECT scanner B, 27% and 80% ICM reduction was obtained at 80 and 100 kV. On the Fast-kV switch DECT, with CNR matched at 120 kV, ICM reductions were 35%, 30%, 23%, and 15% with VMIs at 40, 50, 60, and 68 keV, respectively. On the dual-source DECT, ICM reductions were 52%, 48%, 42%, 33%, and 22% with VMIs at 40, 50, 60, 70, and 80 keV. On the dual-layer DECT, ICM reductions were 74%, 62%, 45%, and 22% with VMIs at 40, 50, 60, and 70 keV. CONCLUSIONS: Our work provided a quantitative baseline for other institutions to further optimize their scanning protocols to reduce the use of ICM.


Asunto(s)
COVID-19 , Medios de Contraste , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Humanos , Medios de Contraste/química , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/instrumentación , SARS-CoV-2 , Adulto , Niño , Relación Señal-Ruido , Dosis de Radiación , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos
10.
J Arthroplasty ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39128781

RESUMEN

BACKGROUND: The challenge of early and rapid diagnosis of periprosthetic joint infection (PJI) remains important. This study aimed to assess the efficacy of dual-energy computed tomography (DECT) iodine maps for diagnosing PJI in total hip arthroplasty. METHODS: We prospectively enrolled 68 patients who had postoperative joint pain after hip arthroplasty. All patients underwent preoperative DECT iodine imaging to quantify iodine concentration (IC) in periprosthetic tissues during arterial and venous phases. The diagnostic efficacy of DECT iodine maps was evaluated by constructing receiver operating characteristic curves according to the Musculoskeletal Infection Society criteria. RESULTS: Compared with erythrocyte sedimentation rate (area under the curve [AUC] = 0.837), polymorphonuclear cell percentage (AUC = 0.703), and C-reactive protein (AUC = 0.837), periprosthetic tissue venous-phase IC (AUC = 0.970) and arterial-phase IC (AUC = 0.964) exhibited outstanding discriminative capability between PJI and aseptic failure. The PJI cut-off point was venous IC = 1.225 mg/mL, with a sensitivity of 92.31% and specificity of 90.48%; for arterial IC = 1.065 mg/mL, the sensitivity was 96.15% and specificity was 90.70%. CONCLUSIONS: This study demonstrates the great potential of DECT iodine maps for the diagnosis of PJI around hip arthroplasty, which helps to differentiate between periprosthetic infection and aseptic failure after hip arthroplasty.

11.
J Clin Ultrasound ; 52(8): 1254-1258, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39081127

RESUMEN

A 74-year-old man was admitted to our emergency department following minor trauma. Plain radiographs and standard computed tomography (CT) scans revealed no signs of fractures. Subsequently, virtual noncalcium (VNCa) images were reconstructed, showing a linear area of bone marrow edema (BME) resembling a femoral neck fracture. Magnetic resonance imaging (MRI) was performed to confirm the presence of BME and an associated intraspongious fracture. In an emergency setting, dual-energy CT (DECT) and VNCa images can successfully identify occult femoral fractures, especially in patients with mild symptoms and minor trauma, thereby preventing misdiagnosis.


Asunto(s)
Fracturas del Fémur , Tomografía Computarizada por Rayos X , Humanos , Masculino , Anciano , Tomografía Computarizada por Rayos X/métodos , Fracturas del Fémur/diagnóstico por imagen , Fracturas Cerradas/diagnóstico por imagen , Diagnóstico Diferencial , Imagen por Resonancia Magnética/métodos
12.
Radiol Med ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256299

RESUMEN

AIM: To assess the correlation of quantitative data of pulmonary Perfused Blood Volume (PBV) on Dual-Energy CT (DECT) datasets in patients with moderate - severe Pulmonary Emphysema (PE) with Lung Perfusion Scintigraphy (LPS) as the reference standard. The secondary endpoints are the correlation between the CT densitometric analysis and the visual assessment of parenchymal destruction with PBV. MATERIALS AND METHODS: Patients with moderate - severe PE candidate to Lung Volumetric Reduction (LVR), with available a pre-procedural LS and a contrast-enhanced DECT were retrospectively included. DECT studies were performed with a 3rd generation Dual-Source CT and the PBV was obtained with a 3-material decomposition algorithm. The CT densitometric analysis was performed with a dedicated commercial software (Pulmo3D). The Goddard Score was used for visual assessment. The perfusion LS were performed after the administration of albumin macroaggregates labeled with 99mTechnetium. The image revision was performed by two radiologists or nuclear medicine physicians blinded, respectively, to LS and DECT data. The statistical analysis was performed with nonparametric tests. RESULTS: Thirty-one patients (18 males, median age 69 y.o., interquartile range 62-71 y.o.) with moderate - severe PE (Median Goddard Score 14/20 and 31% of emphysematous parenchyma at quantitative CT) candidate to LVR were retrospectively included. The median enhancement on PBV was 17 HU. Significant correlation coefficients were demonstrated between lung PBV and LS, poor in apical regions (Rho = 0.1-0.2) and fair (Rho = 0.3-0.5) in middle and lower regions. No significant correlations were recorded between the CT densitometric analysis, the visual score, and the PBV. CONCLUSIONS: Lung perfusion with PBV on DECT is feasible in patients with moderate - severe PE candidate to LVR, and has a poor to fair agreement with LPS.

13.
Radiol Med ; 129(7): 1038-1047, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38743319

RESUMEN

Dual-energy CT stands out as a robust and innovative imaging modality, which has shown impressive advancements and increasing applications in musculoskeletal imaging. It allows to obtain detailed images with novel insights that were once the exclusive prerogative of magnetic resonance imaging. Attenuation data obtained by using different energy spectra enable to provide unique information about tissue characterization in addition to the well-established strengths of CT in the evaluation of bony structures. To understand clearly the potential of this imaging modality, radiologists must be aware of the technical complexity of this imaging tool, the different ways to acquire images and the several algorithms that can be applied in daily clinical practice and for research. Concerning musculoskeletal imaging, dual-energy CT has gained more and more space for evaluating crystal arthropathy, bone marrow edema, and soft tissue structures, including tendons and ligaments. This article aims to analyze and discuss the role of dual-energy CT in musculoskeletal imaging, exploring technical aspects, applications and clinical implications and possible perspectives of this technique.


Asunto(s)
Enfermedades Musculoesqueléticas , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Sistema Musculoesquelético/diagnóstico por imagen , Algoritmos
14.
Radiol Med ; 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39287697

RESUMEN

PURPOSE: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS: Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS: Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

15.
J Stroke Cerebrovasc Dis ; : 108083, 2024 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-39393510

RESUMEN

OBJECTIVE: This study investigates the predictive value of dual-energy CT Rho/Z quantitative parameters for delayed hemorrhage post-thrombectomy in patients with acute ischemic stroke MATERIALS AND METHODS: A retrospective analysis was conducted on 80 patients who underwent dual-energy CT after thrombectomy for acute ischemic stroke. Patients were divided into delayed hemorrhage/no delayed hemorrhage, symptomatic intracranial hemorrhage/asymptomatic intracranial hemorrhage and cerebral parenchymal hematoma/no cerebral parenchymal hematoma groups RESULTS: The quantitative parameters significantly associated with delayed hemorrhage are DEI and Zeff (p < 0.001), with the optimal cutoff values for DEI and Zeff being 0.045 and 9.355, respectively. The quantitative parameters significantly associated with symptomatic intracranial hemorrhage are DEI and Zeff (p < 0.001), with the optimal cutoff values being 0.064 and 9.422, respectively. The parameters significantly associated with cerebral parenchymal hematoma are DEI and Zeff (p < 0.001), with the optimal cutoff values for DEI and Zeff being 0.058 and 9.09, respectively CONCLUSION: The DEI and Zeff parameters derived from dual-energy CT Rho/Z analysis are valuable in predicting delayed hemorrhage, symptomatic intracranial hemorrhage, and cerebral parenchymal hematoma in patients with acute ischemic stroke following thrombectomy.

16.
J Xray Sci Technol ; 32(1): 69-85, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38189729

RESUMEN

BACKGROUND: Slow kVp switching technique is an important approach to realize dual-energy CT (DECT) imaging, but its performance has not been thoroughly investigated yet. OBJECTIVE: This study aims at comparing and evaluating the DECT imaging performance of different slow kVp switching protocols, and thus helps determining the optimal system settings. METHODS: To investigate the impact of energy separation, two different beam filtration schemes are compared: the stationary beam filtration and dynamic beam filtration. Moreover, uniform tube voltage modulation and weighted tube voltage modulation are compared along with various modulation frequencies. A model-based direct decomposition algorithm is employed to generate the water and iodine material bases. Both numerical and physical experiments are conducted to verify the slow kVp switching DECT imaging performance. RESULTS: Numerical and experimental results demonstrate that the material decomposition is less sensitive to beam filtration, voltage modulation type and modulation frequency. As a result, robust material-specific quantitative decomposition can be achieved in slow kVp switching DECT imaging. CONCLUSIONS: Quantitative DECT imaging can be implemented with slow kVp switching under a variety of system settings.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Algoritmos
17.
J Xray Sci Technol ; 32(2): 229-252, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38306088

RESUMEN

Compared with conventional single-energy computed tomography (CT), dual-energy CT (DECT) provides better material differentiation but most DECT imaging systems require dual full-angle projection data at different X-ray spectra. Relaxing the requirement of data acquisition is an attractive research to promote the applications of DECT in wide range areas and reduce the radiation dose as low as reasonably achievable. In this work, we design a novel DECT imaging scheme with dual quarter scans and propose an efficient method to reconstruct the desired DECT images from the dual limited-angle projection data. We first study the characteristics of limited-angle artifacts under dual quarter scans scheme, and find that the negative and positive artifacts of DECT images are complementarily distributed in image domain because the corresponding X-rays of high- and low-energy scans are symmetric. Inspired by this finding, a fusion CT image is generated by integrating the limited-angle DECT images of dual quarter scans. This strategy enhances the true image information and suppresses the limited-angle artifacts, thereby restoring the image edges and inner structures. Utilizing the capability of neural network in the modeling of nonlinear problem, a novel Anchor network with single-entry double-out architecture is designed in this work to yield the desired DECT images from the generated fusion CT image. Experimental results on the simulated and real data verify the effectiveness of the proposed method. This work enables DECT on imaging configurations with half-scan and largely reduces scanning angles and radiation doses.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Redes Neurales de la Computación , Cintigrafía
18.
Pol J Radiol ; 89: e324-e327, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39139259

RESUMEN

Purpose: To determine the feasibility of meniscal imaging using virtual monochromatic images obtained through dualenergy computed tomography (DECT) technique, and to determine which keV levels optimise contrast resolution. Material and methods: All DECT exams were performed on a Discovery CT750 HD system from GE Healthcare. Virtual monochromatic images were reconstructed at 40 keV, 73 keV, 106 keV, and 139 keV. Contrast resolution of the medial and lateral menisci using a 5-point Likert scale at each keV level was determined through a consensus agreement by 2 fellowship-trained musculoskeletal radiologists. Friedman's and Wilcoxon signed rank tests were used to compare visualisation scores across different keV levels. Results: Seventeen knee exams from 10 patients met criteria for inclusion in the study. All patients included in the study cohort were male. The median age of patients was 46 years (interquartile range, 35-53 years). Virtual monochromatic images at 40 keV demonstrated highest contrast resolution of the menisci, with a statistically significant difference between contrast resolution scores at 40 keV and 76 keV, Friedman test: p < 0.0001. Conclusions: Meniscal imaging is feasible using DECT virtual monochromatic images at low keV levels. Improved contrast resolution at these specified KeV values could pave the way for further research in this field to determine its role in the future as an alternative option for assessment of the menisci in patients with contraindications to MRI or in the setting of a periarticular ferromagnetic foreign body obscuring the field of view.

19.
Development ; 147(11)2020 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-32439754

RESUMEN

For decades, clearing and staining with Alcian Blue and Alizarin Red has been the gold standard to image vertebrate skeletal development. Here, we present an alternate approach to visualise bone and cartilage based on X-ray microCT imaging, which allows the collection of genuine 3D data of the entire developing skeleton at micron resolution. Our novel protocol is based on ethanol fixation and staining with Ruthenium Red, and efficiently contrasts cartilage matrix, as demonstrated in whole E16.5 mouse foetuses and limbs of E14 chicken embryos. Bone mineral is well preserved during staining, thus the entire embryonic skeleton can be imaged at high contrast. Differences in X-ray attenuation of ruthenium and calcium enable the spectral separation of cartilage matrix and bone by dual energy microCT (microDECT). Clearing of specimens is not required. The protocol is simple and reproducible. We demonstrate that cartilage contrast in E16.5 mouse foetuses is adequate for fast visual phenotyping. Morphometric skeletal parameters are easily extracted. We consider the presented workflow to be a powerful and versatile extension to the toolkit currently available for qualitative and quantitative phenotyping of vertebrate skeletal development.


Asunto(s)
Huesos/diagnóstico por imagen , Cartílago/diagnóstico por imagen , Feto/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Animales , Huesos/anatomía & histología , Cartílago/anatomía & histología , Embrión de Pollo , Pollos , Embrión de Mamíferos/diagnóstico por imagen , Embrión de Mamíferos/patología , Feto/patología , Ratones , Fenotipo
20.
Eur Radiol ; 33(6): 4094-4102, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36600125

RESUMEN

OBJECTIVES: Bone marrow edema (BME) from dual-energy CT is useful to direct attention to radiographically occult fractures. The aim was to characterize utility of BME of lower extremity (LE) fractures with the hypothesis that stabilized and post-acute fractures exhibit decreased extent and frequency of BME than non-stabilized and acute fractures, respectively. METHODS: An IRB-approved retrospective review of known LE fractures. A total of 141 cases met inclusion criteria, including 82 fractures without splint/cast stabilization, and 59 cases with stabilization. Two readers independently recorded BME, and its multiplicity and area (mm2). A separate reader assessed fracture location, comminution, and chronicity. Wilcoxon rank sum test, multiple regression, intraclass correlation (ICC), kappa statistics, and chi-square tests were used. RESULTS: BME was significantly larger in non-stabilized (859.3 mm2 (420.6-1451.8)) than stabilized fractures (493.5 mm2 (288.8-883.2)), p = .011). Comminuted (p = 0.006), non-stabilized (p = 0.0004), and acute fractures (p = 0.036) were all associated with larger BME area. BME presence had excellent results for both stabilized (Cohen's Kappa = 0.81) and non-stabilized fractures (Cohen's Kappa = 0.84). ICC for BME area showed excellent correlation for both stabilized (ICC = 0.78) and non-stabilized groups (ICC = 0.86). BME multiplicity showed excellent agreement for stabilized (ICC = 0.81) and good agreement for non-stabilized (ICC = 0.67) fractures. Lastly, stabilized cases showed increased multiplicity of BME compared to non-stabilized fractures (p < 0.001). CONCLUSIONS: BME evaluation can assist in differentiation of acute versus post-acute fractures. Extent of BME is reduced with splint/cast stabilization, which may limit its accuracy in detection of lower extremity fractures. KEY POINTS: • Evaluation of bone marrow edema on dual-energy CT aids in differentiation of acute versus post-acute fracture. • Bone marrow edema evaluation is limited in the setting of post-acute or stabilized fractures. • There is decreased frequency and extent of bone marrow edema in post-acute, non-comminuted, and stabilized fractures.


Asunto(s)
Enfermedades de la Médula Ósea , Fracturas Óseas , Humanos , Médula Ósea , Pierna , Tomografía Computarizada por Rayos X/métodos , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema/diagnóstico por imagen , Extremidad Inferior/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS