Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Angew Chem Int Ed Engl ; 62(22): e202217047, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-36757677

RESUMEN

Insufficient vacuum stability of matrix chemicals is a major limitation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) of large tissue sample cohorts. Here, we designed and synthesized the photo-cleavable caged molecule 4,5-dimethoxy-2-nitrobenzyl-2,5-dihydroxyacetophenone (DMNB-2,5-DHAP) and employed it for lipid MALDI-MSI of mouse brain tissue sections. DMNB-2,5-DHAP is vacuum-stable in a high vacuum MALDI ion source for at least 72 h. Investigation of the uncaging process suggested that the built-in laser (355 nm) in the MALDI ion source promoted the in situ generation of 2,5-DHAP. A caging group is used for the first time in designing a MALDI matrix that is vacuum-stable, uncaged upon laser irradiation during the measurement process, and that boosts lipid ion intensity with MALDI-2 laser-induced postionization.


Asunto(s)
Diagnóstico por Imagen , Rayos Láser , Ratones , Animales , Vacio , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Lípidos/análisis
2.
Molecules ; 27(8)2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35458772

RESUMEN

A significant area of study and upgrading for increasing sensitivity and general performances of matrix-assisted laser-desorption ionization (MALDI) mass spectrometry (MS) is related to matrix design. Several efforts have been made to address the challenge of low-mass-region interference-free for metabolomics analysis and specifically for lipidomics. To this aim, rationally designed matrices as 4-chloro-α-cyanocinnamic acid (ClCCA) were introduced and reported to provide enhanced analytical performances. We have taken this rational design one step further by developing and optimizing new MALDI matrices with a range of modifications on the CHCA core, involving different functionalities and substituents. Of particular interest was the understanding of the electron-withdrawing (e.g., nitro-) or donating (e.g., methoxy-) effects along with the extent of conjugation on the ionization efficiency. In the present work, ten matrices were designed on a reasonable basis, synthesized, and characterized by NMR and UV spectroscopies and laser desorption ionization. With the assistance of these putative MALDI matrices, samples containing phospholipids (PL), and neutral di-/tri-acylglycerols (DAG, TAG) were investigated using milk, fish, blood, and human plasma extracts. In comparison with CHCA and ClCCA, four of them, viz. [(2E,4E)-2-cyano-5-(4-methoxyphenyl)penta-2,4-dienoic acid] (1), [(2E,4E)-2-cyano-5-(4-nitrophenyl)penta-2,4-dienoic acid] (2), [(E)-2-cyano-3-(6-methoxynaphthalen-2-yl)acrylic acid] (6) and [(E)-2-cyano-3-(naphthalen-2-yl)acrylic acid] (7) displayed good to even excellent performances as MALDI matrices in terms of ionization capability, interference-free spectra, S/N ratio, and reproducibility. Especially compound 7 (cyano naphthyl acrylic acid, CNAA) was the election matrix for PL analysis and matrix 2 (cyano nitrophenyl dienoic acid, CNDA) for neutral lipids such as DAG and TAG in positive ion mode.


Asunto(s)
Lípidos , Leche , Animales , Rayos Láser , Lípidos/análisis , Leche/química , Reproducibilidad de los Resultados , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
3.
Anal Bioanal Chem ; 413(10): 2599-2617, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33215311

RESUMEN

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a fast-growing technique for visualization of the spatial distribution of the small molecular and macromolecular biomolecules in tissue sections. Challenges in MALDI-MSI, such as poor sensitivity for some classes of molecules or limited specificity, for instance resulting from the presence of isobaric molecules or limited resolving power of the instrument, have encouraged the MSI scientific community to improve MALDI-MSI sample preparation workflows with innovations in chemistry. Recent developments of novel small organic MALDI matrices play a part in the improvement of image quality and the expansion of the application areas of MALDI-MSI. This includes rationally designed/synthesized as well as commercially available small organic molecules whose superior matrix properties in comparison with common matrices have only recently been discovered. Furthermore, on-tissue chemical derivatization (OTCD) processes get more focused attention, because of their advantages for localization of poorly ionizable metabolites and their' in several cases' more specific imaging of metabolites in tissue sections. This review will provide an overview about the latest developments of novel small organic matrices and on-tissue chemical derivatization reagents for MALDI-MSI. Graphical abstract.


Asunto(s)
Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Animales , Técnicas Histológicas/instrumentación , Técnicas Histológicas/métodos , Humanos , Indicadores y Reactivos , Imagen Molecular/instrumentación , Imagen Molecular/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación
4.
New Phytol ; 228(6): 1986-2002, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32654288

RESUMEN

Understanding when and where metabolites accumulate provides important cues to the gene function. Mass spectrometry imaging (MSI) enables in situ temporal and spatial measurement of a large assortment of metabolites, providing mapping information regarding their cellular distribution. To describe the current state and technical advances using MSI in plant sciences, we employed MSI to demonstrate its significant contribution to the study of plant specialised metabolism. We show that coupling MSI with: (1) RNA interference (RNAi), (2) virus induced gene silencing (VIGS), (3) agroinfiltration or (4) samples derived from plant natural variation provides great opportunities to understand the accurate gene-metabolite relationship and discover novel gene-associated metabolites. This was exemplified in three plant species (i.e. tomato, tobacco and wheat) by mapping the distribution of metabolites possessing a range of polarities. In particular, we demonstrated that MSI is able to spatially map an entire metabolic pathway, including intermediates and final products, in the intricate biosynthetic route to tomato fruit steroidal glycoalkaloids. We therefore envisage MSI as a key component of the metabolome analysis arsenal employed in plant gene discovery strategies.


Asunto(s)
Genes de Plantas , Solanum lycopersicum , Solanum lycopersicum/genética , Espectrometría de Masas , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Nicotiana/genética , Triticum
5.
Molecules ; 25(24)2020 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-33371472

RESUMEN

The effectiveness of a synthesized matrix, α-cyano-5-phenyl-2,4-pentadienic acid (CPPA), for protein analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in complex samples such as foodstuff and bacterial extracts, is demonstrated. Ultraviolet (UV) absorption along with laser desorption/ionization mass spectrometry (LDI-MS) experiments were systematically conducted in positive ion mode under standard Nd:YLF laser excitation with the aim of characterizing the matrix in terms of wavelength absorption and proton affinity. Besides, the results for standard proteins revealed that CPPA significantly enhanced the protein signals, reduced the spot-to-spot variability and increased the spot homogeneity. The CPPA matrix was successful employed to investigate intact microorganisms, milk and seed extracts for protein profiling. Compared to conventional matrices such as sinapinic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA) and 4-chloro-α-cyanocinnamic acid (CClCA), CPPA exhibited better signal-to-noise (S/N) ratios and a uniform response for most examined proteins occurring in milk, hazelnut and in intact bacterial cells of E. coli. These findings not only provide a reactive proton transfer MALDI matrix with excellent reproducibility and sensitivity, but also contribute to extending the battery of useful matrices for intact protein analysis.


Asunto(s)
Proteínas/análisis , Proteínas/química , Animales , Cinamatos/química , Corylus/química , Ácidos Cumáricos/química , Escherichia coli/química , Leche/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
6.
Anal Bioanal Chem ; 410(9): 2437-2447, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29445834

RESUMEN

Unequivocal assignment of phospholipid peaks in complex mixtures is difficult if only the m/z values but no tandem mass spectrometry (MS/MS) data are available. This is usually the case for matrix-assisted laser/desorption ionization time-of-flight (MALDI-TOF) MS imaging experiments and the analysis has normally to be performed without prior separation. Another problem might be the often matrix-induced loss of one methyl group in phosphatidylcholine (PC) species, which makes them detectable as negative ions becoming isomers of some phosphatidylethanolamines (PEs). Selected lipid mixtures of known compositions were investigated by negative ion MALDI-TOF MS and various imaging experiments. In addition to common matrices such as 2,5-dihydroxybenzoic acid (DHB) and 9-aminoacridine (9-AA), different binary matrices, including 2,5-dihydroxyacetophenone (2,5-DHAP) as matrix additive to DHB, were tested to probe their performance in both ionization modes. Beside artificial PC and PE mixtures of known compositions, egg yolk and liver extracts as well as cryosections from liver and pancreas tissue were selected as biologically relevant systems. The majority of the binary MALDI matrices used here leads to the loss of a methyl group from PC in the negative ion mode, which makes the clear identification of PE species ambiguous. However, this problem does not apply if a mixture of DHB and 2,5-DHAP is used. Therefore, the application of DHB/2,5-DHAP as matrix is a simple method to unequivocally identify PEs even in complex mixtures and tissue sections as negative ions and without the necessity to separate the individual lipid classes prior to MS detection. Graphical abstract Many common MALDI matrices (such as 9-AA) induce the loss of a methyl group from PC rendering the PC detectable as negative ion. These ions (m/z 744.6 in the upper trace) represent isomers of typical PE species. It will be shown that this problem can be avoided if mixtures between DHB and 2,5-DHAP are applied. At these conditions, POPC is exclusively detectable as a matrix adduct with DHB (at m/z 912.6, lower trace) and does not interfere with PE. This approach can also be used in MALDI MS imaging.


Asunto(s)
Acetofenonas/química , Gentisatos/química , Fosfatidiletanolaminas/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Animales , Yema de Huevo/química , Hígado/química , Páncreas/química , Fosfolípidos/análisis , Porcinos
7.
Anal Bioanal Chem ; 409(6): 1569-1580, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27909779

RESUMEN

A key aspect for the further development of matrix-assisted laser desorption ionization (MALDI)-mass spectrometry (MS) is a better understanding of the working principles of MALDI matrices. To address this issue, a chemical compound library of 59 structurally related cinnamic acid derivatives was synthesized. Potential MALDI matrices were evaluated with sulfatides, a class of anionic lipids which are abundant in complex brain lipid mixtures. For each matrix relative mean S/N ratios of sulfatides were determined against 9-aminoacridine as a reference matrix using negative ion mass spectrometry with 355 and 337 nm laser systems. The comparison of matrix features with their corresponding relative mean S/N ratios for sulfatide detection identified correlations between matrix substitution patterns, their chemical functionality, and their MALDI-MS performance. Crystal structures of six selected matrices provided structural insight in hydrogen bond interactions in the solid state. Principal component analysis allowed the additional identification of correlation trends between structural and physical matrix properties like number of exchangeable protons at the head group, MW, logP, UV-Vis, and sulfatide detection sensitivity. Graphical abstract Design, synthesis and mass spectrometric evaluation of MALDI-MS matrix compound libraries allows the identification of matrix structure - MALDI-MS performance relationships using multivariate statistics as a tool.


Asunto(s)
Cinamatos/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Sulfoglicoesfingolípidos/análisis , Cristalografía por Rayos X , Modelos Moleculares , Análisis de Componente Principal
8.
Anal Bioanal Chem ; 408(22): 6223-33, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27382971

RESUMEN

Quantitative analysis of small molecules by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been a challenging task due to matrix-derived interferences in low m/z region and poor reproducibility of MS signal response. In this study, we developed an approach by applying black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix for the quantitative analysis of small molecules for the first time. Black phosphorus-assisted laser desorption/ionization mass spectrometry (BP/ALDI-MS) showed clear background and exhibited superior detection sensitivity toward quaternary ammonium compounds compared to carbon-based materials. By combining stable isotope labeling (SIL) strategy with BP/ALDI-MS (SIL-BP/ALDI-MS), a variety of analytes labeled with quaternary ammonium group were sensitively detected. Moreover, the isotope-labeled forms of analytes also served as internal standards, which broadened the analyte coverage of BP/ALDI-MS and improved the reproducibility of MS signals. Based on these advantages, a reliable method for quantitative analysis of aldehydes from complex biological samples (saliva, urine, and serum) was successfully established. Good linearities were obtained for five aldehydes in the range of 0.1-20.0 µM with correlation coefficients (R (2)) larger than 0.9928. The LODs were found to be 20 to 100 nM. Reproducibility of the method was obtained with intra-day and inter-day relative standard deviations (RSDs) less than 10.4 %, and the recoveries in saliva samples ranged from 91.4 to 117.1 %. Taken together, the proposed SIL-BP/ALDI-MS strategy has proved to be a reliable tool for quantitative analysis of aldehydes from complex samples. Graphical Abstract An approach for the determination of small molecules was developed by using black phosphorus (BP) as a matrix-assisted laser desorption ionization (MALDI) matrix.


Asunto(s)
Aldehídos/sangre , Aldehídos/orina , Fósforo/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Aldehídos/análisis , Humanos , Marcaje Isotópico/métodos , Límite de Detección , Saliva/química
9.
J Agric Food Chem ; 72(12): 6762-6771, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38478706

RESUMEN

Most of the traditional matrices cannot simultaneously image multiple lipids and phytohormones, so screening and discovery of novel matrices stand as essential approaches for broadening the application scope of matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). In this work, 12 organic small molecule compounds were comprehensively screened and investigated as potential MALDI matrices for simultaneous imaging analysis of various lipids and phytohormones. In the positive ionization mode, p-nitroaniline, m-nitroaniline, and 2-aminoterephthalic acid displayed good performance for the highly sensitive detection of lysophosphatidylcholines (LPCs), phosphatidylcholines (PCs), and triacylglycerols (TGs). Furthermore, p-nitroaniline possessed excellent characteristics of strong ultraviolet absorption and homogeneous cocrystallization, making it a desirable matrix for MALDI-MSI analysis of eight plant hormones. Compared with conventional matrices (2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and 9-aminoacridine (9-AA), the use of p-nitroaniline resulted in higher ionization efficiency, superior sensitivity, and clearer imaging images in dual polarity mode. Our research offers valuable guidance and new ideas for future endeavors in matrix screening.


Asunto(s)
Compuestos de Anilina , Diagnóstico por Imagen , Reguladores del Crecimiento de las Plantas , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Lípidos/análisis
10.
J Agric Food Chem ; 71(1): 952-962, 2023 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-36541565

RESUMEN

Glycans recently attracted considerable attention as the proposal of cross-reactive carbohydrate determinants for food allergy. Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) is powerful in analyzing biomolecules, while its applications in glycans are still challenging. Herein, a novel reactive matrix-assisted laser desorption/ionization (MALDI) matrix, 2-hydrazinoterephthalic acid, was rationally designed and synthesized. It provides uniform co-crystallization with glycans and only produces deprotonated ions with high intensities in the negative-ion mode. In combination with sinapic acid, a rapid and high-throughput method was established for on-target analysis of glycans with a superior limit of detection at the femtomole level and a good linearity (R2 > 0.999). Furthermore, the established method was successfully applied to quantify N-glycans in different cultivars and tissues of peach [Prunus persica (L.) Batsch]. Our work suggests the potential role of N-glycans as biomarkers for food-borne allergy and lays a methodological foundation for the elucidation of the possible relationship between carbohydrate epitopes and food allergy.


Asunto(s)
Hipersensibilidad a los Alimentos , Prunus persica , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Polisacáridos/química , Iones , Rayos Láser
11.
Toxicon X ; 18: 100151, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36873112

RESUMEN

Venoms from tarantulas contain low molecular weight vasodilatory compounds whose biological action is conceived as part of the envenomation strategy due to its propagative effects. However, some properties of venom-induced vasodilation do not match those described by such compounds, suggesting that other toxins may cooperate with these ones to produce the observed biological effect. Owing to the distribution and function of voltage-gated ion channels in blood vessels, disulfide-rich peptides isolated from venoms of tarantulas could be conceived into potential vasodilatory compounds. However, only two peptides isolated from spider venoms have been investigated so far. This study describes for the first time a subfraction containing inhibitor cystine knot peptides, PrFr-I, obtained from the venom of the tarantula Poecilotheria regalis. This subfraction induced sustained vasodilation in rat aortic rings independent of vascular endothelium and endothelial ion channels. Furthermore, PrFr-I decreased calcium-induced contraction of rat aortic segments and reduced extracellular calcium influx to chromaffin cells by the blockade of L-type voltage-gated calcium channels. This mechanism was unrelated to the activation of potassium channels from vascular smooth muscle, since vasodilation was not affected in the presence of TEA, and PrFr-I did not modify the conductance of the voltage-gated potassium channel Kv10.1. This work proposes a new envenomating function of peptides from venoms of tarantulas, and establishes a new mechanism for venom-induced vasodilation.

12.
J Mass Spectrom Adv Clin Lab ; 23: 7-13, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34988541

RESUMEN

Ion mobility spectrometry (IMS) is an analytical technique where ions are separated in the gas phase based on their mobility through a buffer gas in the presence of an electric field. An ion passing through an IMS device has a characteristic collisional cross section (CCS) value that depends on the buffer gas used. IMS can be coupled with mass spectrometry (MS), which characterizes an ion based on a mass-to-charge ratio (m/z), to increase analytical specificity and provide further physicochemical information. In particular, IMS-MS is of ever-increasing interest for the analysis of lipids, which can be problematic to accurately identify and quantify in bodily fluids by liquid chromatography (LC) with MS alone due to the presence of isomers, isobars, and structurally similar analogs. IMS provides an additional layer of separation when combined with front-end LC approaches, thereby, enhancing peak capacity and analytical specificity. CCS (and also ion mobility drift time) can be plotted against m/z ion intensity and/or LC retention time in order to generate in-depth molecular profiles of a sample. Utilization of IMS-MS for routine clinical laboratory testing remains relatively unexplored, but areas do exist for potential implementation. A brief update is provided here on lipid analysis using IMS-MS with a perspective on some applications in the clinical laboratory.

13.
J Mass Spectrom Adv Clin Lab ; 23: 26-38, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35156074

RESUMEN

Mass spectrometry imaging (MSI) is used in many aspects of clinical research, including pharmacokinetics, toxicology, personalised medicine, and surgical decision-making. Maximising its potential requires the spatial integration of MSI images with imaging data from existing clinical imaging modalities, such as histology and MRI. To ensure that the information is properly integrated, all contributing images must be accurately aligned. This process is called image registration and is the focus of this review. In light of the ever-increasing spatial resolution of MSI instrumentation and a diversification of multi-modal MSI studies (e.g., spatial omics, 3D-MSI), the accuracy, versatility, and precision of image registration must increase accordingly. We review the application of image registration to align MSI data with different clinically relevant ex vivo and in vivo imaging techniques. Based on this, we identify steps in the current image registration processes where there is potential for improvement. Finally, we propose a roadmap for community efforts to address these challenges in order to increase registration quality and help MSI to fully exploit its multi-modal potential.

14.
J Mass Spectrom Adv Clin Lab ; 26: 36-46, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36388058

RESUMEN

Introduction: Although Staphylococcus aureus is the leading cause of biofilm-related infections, the lipidomic distributions within these biofilms is poorly understood. Here, lipidomic mapping of S. aureus biofilm cross-sections was performed to investigate heterogeneity between horizontal biofilm layers. Methods: S. aureus biofilms were grown statically, embedded in a mixture of carboxymethylcellulose/gelatin, and prepared for downstream matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS). Trapped ion mobility spectrometry (TIMS) was also applied prior to mass analysis. Results: Implementation of TIMS led to a âˆ¼ threefold increase in the number of lipid species detected. Washing biofilm samples with ammonium formate (150 mM) increased signal intensity for some bacterial lipids by as much as tenfold, with minimal disruption of the biofilm structure. MALDI TIMS IMS revealed that most lipids localize primarily to a single biofilm layer, and species from the same lipid class such as cardiolipins CL(57:0) - CL(66:0) display starkly different localizations, exhibiting between 1.5 and 6.3-fold intensity differences between layers (n = 3, p < 0.03). No horizontal layers were observed within biofilms grown anaerobically, and lipids were distributed homogenously. Conclusions: High spatial resolution analysis of S. aureus biofilm cross-sections by MALDI TIMS IMS revealed stark lipidomic heterogeneity between horizontal S. aureus biofilm layers demonstrating that each layer was molecularly distinct. Finally, this workflow uncovered an absence of layers in biofilms grown under anaerobic conditions, possibly indicating that oxygen contributes to the observed heterogeneity under aerobic conditions. Future applications of this workflow to study spatially localized molecular responses to antimicrobials could provide new therapeutic strategies.

15.
Metabolites ; 11(3)2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33806402

RESUMEN

The combination of 13C-isotopic labeling and mass spectrometry imaging (MSI) offers an approach to analyze metabolic flux in situ. However, combining isotopic labeling and MSI presents technical challenges ranging from sample preparation, label incorporation, data collection, and analysis. Isotopic labeling and MSI individually create large, complex data sets, and this is compounded when both methods are combined. Therefore, analyzing isotopically labeled MSI data requires streamlined procedures to support biologically meaningful interpretations. Using currently available software and techniques, here we describe a workflow to analyze 13C-labeled isotopologues of the membrane lipid and storage oil lipid intermediate-phosphatidylcholine (PC). Our results with embryos of the oilseed crops, Camelina sativa and Thlaspi arvense (pennycress), demonstrated greater 13C-isotopic labeling in the cotyledons of developing embryos compared with the embryonic axis. Greater isotopic enrichment in PC molecular species with more saturated and longer chain fatty acids suggest different flux patterns related to fatty acid desaturation and elongation pathways. The ability to evaluate MSI data of isotopically labeled plant embryos will facilitate the potential to investigate spatial aspects of metabolic flux in situ.

16.
Curr Res Food Sci ; 4: 821-828, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34841268

RESUMEN

Ellagitannins (ETs) are hydrolysable tannins composed of a polyol core, primarily glucose, which is esterified with hexahydroxydiphenic acid (HHDP), and in some cases, gallic acid. ETs are the major phenolic compounds found in strawberries and may contribute to the health-related properties of strawberries, because of their strong antioxidative activity. However, their distribution in the strawberry fruit remains unclear. In this study, matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) was used to visualize ETs in ripe strawberry fruits. Five peaks, corresponding to the m/z values of ET [M-H]- ions detected in the MALDI-MS spectrum of strawberry extracts, were identified as strictinin, pedunculagin, casuarictin, davuriicin M1, and an unknown ET using MALDI-tandem MS (MS/MS). In addition, liquid chromatography-electrospray ionization-MS/MS of the extracts revealed the presence of pedunculagin isomers and the unknown ET. Ion images of these five ETs were reconstructed using MALDI-MSI. Strictinin was widely distributed in and around the achene seed coats, while the other ETs were dispersed in and around the seed coats, and at the bottom of the receptacle; pedunculagin was distributed in the epidermis and pith, whereas casuarictin, the unknown ET, and davuriicin M1 were distributed in the pith. Moreover, MALDI-MSI of a casuarictin standard indicated that in-source fragmentation weakly affected the ion images. The results suggest that the distribution of ETs depends on the presence or absence of their constituents, namely galloyl units, HHDP, and bis-HHDP. To the best of my knowledge, this is the first report on the visualization of ETs in plant tissues using MSI, MALDI-MSI may be a useful tool for analyzing the distribution of ETs in the strawberry fruit.

17.
Food Chem (Oxf) ; 3: 100048, 2021 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-35415658

RESUMEN

The processing of dry-cured ham results in the generation of small peptides by the action of endogenous enzymes on muscle proteins. Common proteomic workflows involve previous separation techniques based on liquid chromatography which are expensive and time-consuming. In this study, a convenient proteomic approach based on MALDI-ToF is proposed for the first time for the detection of dipeptides in Spanish dry-cured ham. Dipeptides AH, AL, DD, EV, and VF were identified in hams of 18 and 24 months of dry-curing. This work provides insights on the efficiency of a new peptidomic workflow for the short peptide identification from a complex food matrix and permits to evaluate the sample in terms of the presence of taste-related and bioactive dipeptides.

18.
J Mass Spectrom Adv Clin Lab ; 20: 25-34, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34820668

RESUMEN

INTRODUCTION: Antibiotic-resistant Gram-negative bacteria are of a growing concern globally, especially those producing enzymes conferring resistance. OXA-48-like carbapenemases hydrolyze most ß-lactam antibiotics, with typically low-level hydrolysis of carbapenems, but have limited effect on broad-spectrum cephalosporins. These are frequently co-expressed with extended spectrum ß-lactamases, especially CTX-M-15, which typically shows high level resistance to broad-spectrum cephalosporins, yet is carbapenem susceptible. The combined resistance profile makes the need for successful detection of these specific resistance determinants imperative for effective antibiotic therapy. OBJECTIVES: The objective of this study is to detect and identify OXA-48-like and CTX-M-15 enzymes using mass spectrometry, and to subsequently develop a method for detection of both enzyme types in combination with liquid chromatography. METHODS: Cells grown in either broth or on agar were harvested, lysed, and, in some cases buffer-exchanged. Lysates produced from bacterial cells were separated and analyzed via liquid chromatography with mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS). RESULTS: The intact proteins of OXA-48, OXA-181, and OXA-232 (collectively OXA-48-like herein) and CTX-M-15 were characterized and detected. Acceptance criteria based on sequence-informative fragments from each protein group were established as confirmatory markers for the presence of the protein(s). A total of 25 isolates were successfully tested for OXA-48 like (2), CTX-M-15 (3), or expression of both (7) enzymes. Thirteen isolates served as negative controls. CONCLUSIONS: Here we present a method for the direct and independent detection of both OXA-48-like carbapenemases and CTX-M-15 ß-lactamases using LC-MS/MS. The added sensitivity of MS/MS allows for simultaneous detection of at least two co-eluting, co-isolated and co-fragmented proteins from a single mass spectrum.

19.
Acta Pharm Sin B ; 11(11): 3665-3677, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34900545

RESUMEN

Detailed knowledge on tissue-specific metabolic reprogramming in diabetic nephropathy (DN) is vital for more accurate understanding the molecular pathological signature and developing novel therapeutic strategies. In the present study, a spatial-resolved metabolomics approach based on air flow-assisted desorption electrospray ionization (AFADESI) and matrix-assisted laser desorption ionization (MALDI) integrated mass spectrometry imaging (MSI) was proposed to investigate tissue-specific metabolic alterations in the kidneys of high-fat diet-fed and streptozotocin (STZ)-treated DN rats and the therapeutic effect of astragaloside IV, a potential anti-diabetic drug, against DN. As a result, a wide range of functional metabolites including sugars, amino acids, nucleotides and their derivatives, fatty acids, phospholipids, sphingolipids, glycerides, carnitine and its derivatives, vitamins, peptides, and metal ions associated with DN were identified and their unique distribution patterns in the rat kidney were visualized with high chemical specificity and high spatial resolution. These region-specific metabolic disturbances were ameliorated by repeated oral administration of astragaloside IV (100 mg/kg) for 12 weeks. This study provided more comprehensive and detailed information about the tissue-specific metabolic reprogramming and molecular pathological signature in the kidney of diabetic rats. These findings highlighted the promising potential of AFADESI and MALDI integrated MSI based metabolomics approach for application in metabolic kidney diseases.

20.
J Mass Spectrom ; 55(10): e4609, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32881213

RESUMEN

The mass spectral analysis of metal salts, especially lanthanide and transition metal salts, can be challenging. Although getting information on the metal present is usually straightforward, obtaining information on the correct oxidation state and anion composition is challenging. Many ionisation techniques have some redox component to the ionisation process, which commonly results in changing the oxidation state of the metal and the associated loss of ligand and anion information. We present here a simple method for negative ion matrix-assisted laser desorption/ionisation mass spectrometry using the non-acidic flavonoid flavone as a novel matrix. This results in reliable information on the oxidation state of the metal as spectra are dominated by anion adduct ions with very little (typically no) redox processes occurring.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda