Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 477
Filtrar
1.
Nano Lett ; 24(23): 6906-6915, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38829311

RESUMEN

Herein, a multifunctional nanohybrid (PL@HPFTM nanoparticles) was fabricated to perform the integration of chemodynamic therapy, photothermal therapy, and biological therapy over the long term at a designed location for continuous antibacterial applications. The PL@HPFTM nanoparticles consisted of a polydopamine/hemoglobin/Fe2+ nanocomplex with comodification of tetrazole/alkene groups on the surface as well as coloading of antimicrobial peptides and luminol in the core. During therapy, the PL@HPFTM nanoparticles would selectively cross-link to surrounding bacteria via tetrazole/alkene cycloaddition under chemiluminescence produced by the reaction between luminol and overexpressed H2O2 at the infected area. The resulting PL@HPFTM network not only significantly damaged bacteria by Fe2+-catalyzed ROS production, effective photothermal conversion, and sustained release of antimicrobial peptides but dramatically enhanced the retention time of these therapeutic agents for prolonged antibacterial therapy. Both in vitro and in vivo results have shown that our PL@HPFTM nanoparticles have much higher bactericidal efficiency and remarkably longer periods of validity than free antibacterial nanoparticles.


Asunto(s)
Antibacterianos , Nanopartículas , Antibacterianos/farmacología , Antibacterianos/química , Animales , Nanopartículas/química , Ratones , Escherichia coli/efectos de los fármacos , Polímeros/química , Indoles/química , Indoles/farmacología , Terapia Fototérmica , Humanos , Staphylococcus aureus/efectos de los fármacos , Péptidos Antimicrobianos/química , Péptidos Antimicrobianos/farmacología , Peróxido de Hidrógeno/química , Peróxido de Hidrógeno/farmacología
2.
Chemistry ; : e202400777, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38924153

RESUMEN

Following a new approach, we prepared a nanoink with two separate photothermally responsive absorption bands. One is the localized surface plasmon resonance (LSPR) absorption of gold nanoparticles (AuNP, d =17 nm), the second is the absorption band of two cyanine (Cy) dyes, Cy7-C6 or Cy7-C11, grafted to the AuNP surface through thiolated bridges of different lengths: the close proximity to the Au surface induces full quenching of the Cy fluorescence, resulting in thermal relaxation on irradiation. Attempts to full coat AuNP with the lipophilic Cy7-C6 and Cy7-C11 lead to precipitation from aqueous solutions. We thus prepared AuNP with partial pegylation (30, 50, or 70%), using a long chain thiol-terminated PEG bearing a -COOH function. Addition until saturation of either Cy7-C6 or Cy7-C11 to the partially pegylated AuNP gave the AuNP@Cy/PEGX% hybrids (X = 30, 50, 70) that are stable in water and in the water/alcohol mixtures used to prepare the nanoinks. Further overcoating of AuNP@Cy7-C6/PEG50% with PAH (polyallylamine hydrochloride) avoids LSPR hybridization in the dry nanoink printouts, that present two separate bands. When irradiated with laser sources near their absorption maxima, the printouts of the AuNP@Cy7-C6/PEG50%@PAH nanoink respond on two channels, giving different temperature increases depending on the irradiation wavelength.

3.
Chemphyschem ; 25(6): e202300658, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38269420

RESUMEN

Synthesising and designing pseudocapacitive material with good electrochemical and electrocatalytic behaviour is essential to use as supercapacitor as well as non-enzymatic glucose sensor electrode. In this work, NiCo2 S4 nanoparticles decorated onto the 2D-Carbyne nanosheets are achieved by the solvothermal process. The as-prepared NiCo2 S4 @2D-Carbyne provides rich reaction sites and better diffusion pathways. On usage as an electrode for supercapacitor application, the NiCo2 S4 @2D-Carbyne exhibits the specific capacitance of about 2507 F g-1 at 1 A g-1 . In addition, the fabricated hybrid device generates an energy density of 52.2 Wh kg-1 at a power density of 1.01 kW kg-1 . Besides, the glucose oxidation behaviour of NiCo2 S4 @2D-Carbyne modified GCE has also been performed. The diffusion of glucose from the electrolyte to the electrode obeys the kinetic control process. Furthermore, the fabricated NiCo2 S4 @2D-Carbyne non-enzymatic glucose sensor exhibits a limit of detection of about 34.5 µM with a sensitivity of about 135 µA mM-1 cm-2 . These findings highlight the need to design and synthesis electrode materials with adequate electrolyte-electrode contact, strong structural integrity, and rapid ion/electron transport.

4.
Nanotechnology ; 35(19)2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38271717

RESUMEN

Precise identification of cholesterol levels is crucial for the early diagnosis of cardiovascular risk factors. This paper presents a novel approach for cholesterol detection that circumvents the reliance on enzymatic processes. Leveraging the unique properties of advanced materials and electrochemical principles, our non-enzymatic approach demonstrates enhanced sensitivity, specificity, and limit of detection in cholesterol analysis. A non-enzymatic electrochemical biosensor for Cholesterol, employing a nanohybrid comprising Cu2O nanoparticles decorated with MoS2, is presented. The cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometry techniques were employed to investigate the electrochemical behaviour of the glassy carbon electrode modified with the Cu2O/MoS2nanohybrid. The modified electrode exhibited an excellent sensitivity of 111.74µAµM-1cm-2through the CV method and showcased a low detection limit of 2.18µM and an expansive linear range spanning 0.1-180µM when employing the DPV method. The electrode also showed good selectivity to various interfering components in 0.1 M NaOH and a satisfied stability of about 15 days at room temperature. The study demonstrates the potential for broader applications in clinical diagnostics and monitoring cardiovascular health, paving the way for a paradigm shift in cholesterol detection methodologies and offering a more efficient and cost-effective alternative to traditional enzymatic assays.


Asunto(s)
Molibdeno , Nanopartículas , Molibdeno/química , Cobre/química , Técnicas Electroquímicas/métodos , Nanopartículas/química , Electrodos , Colesterol , Límite de Detección
5.
Environ Res ; 252(Pt 4): 119121, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38734291

RESUMEN

Extensive utilization of pesticides and herbicides to boost agricultural production increased the environmental health risks, which can be mitigate with the aid of highly sensitive detection systems. In this study, an electrochemical sensor for monitoring the carcinogenic pesticides in the environmental samples has been developed based on sulfur-doped graphitic-carbon nitride-gold nanoparticles (SCN-AuNPs) nanohybrid. Thermal polycondensation of melamine with thiourea followed by solvent exfoliation via ultrasonication leads to SCN formation and electroless deposition of AuNPs on SCN leads to SCN-AuNPs nanohybrid synthesis. The chemical composition, S-doping, and the morphology of the nanohybrid were confirmed by various microscopic and spectroscopic tools. The as-synthesized nanohybrid was fabricated with glassy carbon (GC) electrode for determining the carcinogenic hydrazine (HZ) and atrazine (ATZ) in field water samples. The present sensor exhibited superior electrocatalytic activity than GC/SCN and GC/AuNPs electrodes due to the synergism between SCN and AuNPs and the amperometric studies showed the good linear range of detection of 20 nM-0.5 mM and 500 nM-0.5 mM with the limit of detection of 0.22 and 69 nM (S/N = 3) and excellent sensitivity of 1173.5 and 13.96 µA mM-1 cm-2 towards HZ and ATZ, respectively. Ultimately, the present sensor is exploited in environmental samples for monitoring HZ and ATZ and the obtained results are validated with high-performance liquid chromatography (HPLC) technique. The excellent recovery percentage and close agreement with the results of HPLC analysis proved the practicability of the present sensor. In addition, the as-prepared materials were utilized for the photocatalytic degradation of ATZ and the SCN-AuNPs nanohybrid exhibited higher photocatalytic activity with the removal efficiency of 93.6% at 90 min. Finally, the degradation mechanism was investigated and discussed.


Asunto(s)
Carcinógenos , Oro , Grafito , Nanopartículas del Metal , Contaminantes Químicos del Agua , Oro/química , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química , Nanopartículas del Metal/química , Grafito/química , Carcinógenos/análisis , Atrazina/análisis , Atrazina/química , Azufre/química , Azufre/análisis , Técnicas Electroquímicas/métodos , Hidrazinas/análisis , Hidrazinas/química , Compuestos de Nitrógeno/química , Compuestos de Nitrógeno/análisis , Nitrilos/química , Nitrilos/análisis , Monitoreo del Ambiente/métodos
6.
Ecotoxicol Environ Saf ; 275: 116221, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38547728

RESUMEN

Photocatalysis is gaining prominence as a viable alternative to conventional biohazard treatment technologies. Two-dimensional (2D) nanomaterials have become crucial for fabricating novel photocatalysts due to their nanosheet architectures, large surface areas, and remarkable physicochemical properties. Furthermore, a variety of applications are possible with 2D nanomaterials, either in combination with other functional nanoparticles or by utilizing their inherent properties. Henceforth, the review commences its exploration into the synthesis of these materials, delving into their inherent properties and assessing their biocompatibility. Subsequently, an overview of mechanisms involved in the photocatalytic degradation of pollutants and the processes related to antimicrobial action is presented. As an integral part of our review, we conduct a systematic analysis of existing challenges and various types of 2D nanohybrid materials tailored for applications in the photocatalytic degradation of contaminants and the inactivation of pathogens through photocatalysis. This investigation will aid to contribute to the formulation of decision-making criteria and design principles for the next generation of 2D nanohybrid materials. Additionally, it is crucial to emphasize that further research is imperative for advancing our understanding of 2D nanohybrid materials.


Asunto(s)
Contaminantes Ambientales , Nanopartículas , Nanoestructuras , Sustancias Peligrosas , Análisis de Sistemas
7.
Clin Oral Investig ; 28(1): 104, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38243032

RESUMEN

OBJECTIVE: To evaluate the 5-year clinical performance of a glass hybrid restorative system and a nano-hybrid resin composite in moderate to large two-surface class II cavities. MATERIALS AND METHODS: This study was carried out by dental schools in Zagreb, Croatia; Izmir, Turkey; Belgrade, Serbia; and Milan, Italy. A total of 180 patients requiring two class-II two-surface restorations in the molars of the same jaw were recruited. The teeth were randomly restored with either a nano-hybrid resin composite (Tetric EvoCeram, Ivoclar Vivadent) or a glass-hybrid material (EQUIA Forte, GC). During the 5-year follow-up, two calibrated evaluators at each centre scored the restorations annually using the FDI-2 scoring system. The survival rates were calculated using the Kaplan-Meier method and compared using non-parametric matched pair tests (p < 0.05). RESULTS: There were no statistically significant differences between the overall survival and success rates of the two types of restorations (p>0.05). The success rates (FDI-2 scores 1-3) for EQUIA Forte were 81.9% (average annual failure rate: 3.9%) and 90.7% for Tetric EvoCeram (average annual failure rate: 1.9%). The survival rates (FDI-2 scores 1-4) for EQUIA Forte and Tetric EvoCeram were 94.5% and 94.4%, respectively, with an average annual failure rate of 1.1%. CONCLUSIONS: In terms of success and survival rates, both the glass-hybrid restorative system and the nano-hybrid resin composite have been shown to perform satisfactorily. CLINICAL RELEVANCE: The results of this study indicate that EQUIA Forte can be one of the therapeutic options for moderate to large two-surface class II restorations of posterior teeth.


Asunto(s)
Caries Dental , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Resinas Compuestas/uso terapéutico , Materiales Dentales , Diente Molar , Caries Dental/terapia , Vidrio , Cementos de Ionómero Vítreo/uso terapéutico
8.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902697

RESUMEN

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Asunto(s)
Óxido de Aluminio , Café , Color , Resinas Compuestas , Pulido Dental , Propiedades de Superficie , Resinas Compuestas/química , Pulido Dental/métodos , Óxido de Aluminio/química , Ensayo de Materiales , Espectrofotometría , Técnicas In Vitro , Humanos , Diamante/química , Nanocompuestos/química , Blanqueadores Dentales/química , Agua/química , Materiales Dentales/química , Factores de Tiempo
9.
BMC Oral Health ; 24(1): 101, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38233771

RESUMEN

TRIAL DESIGN: This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. The aim of this trial was to compare the two-year clinical performance of partial indirect restorations fabricated from CAD/CAM nano-hybrid composite and ceramic lithium disilicate blocks using the modified USPHS criteria. METHODS: In two parallel groups (n = 50 restorations), fifty participants having mutilated vital teeth with a minimum of two remaining walls were randomly enrolled in this trial and received indirect restorations of either nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland) or Lithium Disilicate (IPS Emax CAD). The restorations were assessed using modified USPHS criteria by two independent blinded assessors at baseline, six months, one-year and two years follow-up visits. Categorical and ordinal data were presented as frequencies and percentages. Categorical data were analyzed using the chi-square test. Ordinal data were analyzed using the Mann-Whitney U test for intergroup comparisons and Freidman's test followed by the Nemenyi post hoc test for intragroup comparisons. Numerical data were presented as mean and standard deviation values. They were analyzed for normality using the Shapiro-Wilk test. Data were found to be normally distributed and were analyzed using the independent t-test. The significance level was set at p ≤ 0.05 within all tests. RESULTS: Forty-eight participants received the allocated intervention and completed the follow-up periods. There was a statistically significant difference between both tested materials for all USPHS criteria regarding Marginal integrity and Marginal discoloration at six-months Follow-up, but with no statistically significant difference at one- and two-year follow-up. CONCLUSIONS: Both materials showed an acceptable, successful clinical performance along the two-years follow-up period. CLINICAL RELEVANCE: The CAD/CAM nano-hybrid composite blocks are as reliable as Lithium disilicate for restoring mutilated vital teeth.


Asunto(s)
Porcelana Dental , Incrustaciones , Humanos , Cerámica , Diseño Asistido por Computadora , Materiales Dentales , Ensayo de Materiales
10.
J Contemp Dent Pract ; 25(3): 221-225, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690693

RESUMEN

AIM: This study aimed to assess the color stability of bioactive restorative materials vs nanohybrid resin composites after 3 months of immersion in three frequently consumed beverages. MATERIALS AND METHODS: Thirty disk-shaped specimens of Giomer dental restorative material (Shofu, Japan) and nanohybrid resin composite (Tokuyama, Japan) were performed using a Teflon mold. Super-Snap system (Shofu, Japan) was utilized to finish and polish the specimens to be preserved for 24 hours in distilled water at 37°C. The samples had been divided into three subgroups (Coffee, tea, Pepsi) (n = 5). The initially displayed color measurements of the samples were performed using a spectrophotometer (VITA Easyshade® V). After 7 days, 30 days, and 90 days, color measurements were repeated, and the E of each sample was estimated. E of each sample was calculated. RESULTS: The Giomer group showed statistically significant higher E values than the nanohybrid resin composite where the p-value was ≤0.0001. Tea subgroup showed the highest statistically significant E values in both groups where the p-value was ≤ 0.0001. The highest statistically significant color change was recorded at 3 months. CONCLUSION: The color of bioactive restorative material is less stable if compared with nanohybrid resin composite. CLINICAL SIGNIFICANCE: As tea and coffee are popular beverages, particularly in Middle Eastern nations, dentists must advise patients about the color change of resin restorations. Patients are advised to brush their teeth immediately after consuming these beverages. How to cite this article: Saber EH, Abielhassan MH, Abed YA, et al. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024;25(3):221-225.


Asunto(s)
Color , Resinas Compuestas , Ensayo de Materiales , , Resinas Compuestas/química , Técnicas In Vitro , Café , Espectrofotometría , Restauración Dental Permanente , Nanocompuestos/química , Materiales Dentales/química , Humanos , Bebidas
11.
Small ; 19(16): e2205320, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36720798

RESUMEN

Capturing rare disease-associated biomarkers from body fluids can offer an early-stage diagnosis of different cancers. Circulating tumor cells (CTCs) are one of the major cancer biomarkers that provide insightful information about the cancer metastasis prognosis and disease progression. The most common clinical solutions for quantifying CTCs rely on the immunomagnetic separation of cells in whole blood. Microfluidic systems that perform magnetic particle separation have reported promising outcomes in this context, however, most of them suffer from limited efficiency due to the low magnetic force generated which is insufficient to trap cells in a defined position within microchannels. In this work, a novel method for making soft micromagnet patterns with optimized geometry and magnetic material is introduced. This technology is integrated into a bilayer microfluidic chip to localize an external magnetic field, consequently enhancing the capture efficiency (CE) of cancer cells labeled with the magnetic nano/hybrid microgels that are developed in the previous work. A combined numerical-experimental strategy is implemented to design the microfluidic device and optimize the capturing efficiency and to maximize the throughput. The proposed design enables high CE and purity of target cells and real-time time on-chip monitoring of their behavior. The strategy introduced in this paper offers a simple and low-cost yet robust opportunity for early-stage diagnosis and monitoring of cancer-associated biomarkers.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microgeles , Células Neoplásicas Circulantes , Humanos , Separación Celular/métodos , Microfluídica , Separación Inmunomagnética/métodos , Células Neoplásicas Circulantes/patología , Línea Celular Tumoral , Fenómenos Magnéticos , Técnicas Analíticas Microfluídicas/métodos
12.
Small ; : e2304862, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38050931

RESUMEN

Atopic dermatitis (AD) is a widespread, recurrent, and chronic inflammatory skin condition that imposes a major burden on patients. Conventional treatments, such as corticosteroids, are associated with various side effects, underscoring the need for innovative therapeutic approaches. In this study, the possibility of using indole-3-acetic acid-loaded layered double hydroxides (IAA-LDHs) is evaluated as a novel treatment for AD. IAA is an auxin-class plant hormone with antioxidant and anti-inflammatory effects. Following the synthesis of IAA-LDH nanohybrids, their ability to induce M2-like macrophage polarization in macrophages obtained from mouse bone marrow is assessed. The antioxidant activity of IAA-LDH is quantified by assessing the decrease in intracellular reactive oxygen species levels. The anti-inflammatory and anti-atopic characteristics of IAA-LDH are evaluated in a mouse model of AD by examining the cutaneous tissues, immunological organs, and cells. The findings suggest that IAA-LDH has great therapeutic potential as a candidate for AD treatment based on its in vitro and in vivo modulation of AD immunology, enhancement of macrophage polarization, and antioxidant activity. This inorganic drug delivery technology represents a promising new avenue for the development of safe and effective AD treatments.

13.
Mol Pharm ; 20(12): 6345-6357, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-37942616

RESUMEN

Despite the continuous advancement of surgical resection techniques, postoperative tumor recurrence and metastasis remain a huge challenge. Here, we constructed an injectable curcumin/doxorubicin-loaded nanoparticle (NanoCD) hydrogel, which could effectively inhibit tumor regrowth and metastasis via reshaping the tumor immune microenvironment (TIME) for highly effective postsurgical cancer treatment. NanoCD was prepared by the controlled assembly of curcumin (CUR) and doxorubicin (DOX) via π-π stacking and hydrogen bonding in the presence of human serum albumin. To facilitate prolonged treatment of postsurgical tumors, NanoCD was further incorporated into the temperature-sensitive Poloxamer 407 gel (NanoCD@Gel) for intracavity administration. Mechanistically, DOX induced the generation of intracellular reactive oxygen species (ROS) and CUR reduced the ROS metabolism by inhibiting thioredoxin reductase (TrxR). The synergy of DOX and CUR amplified intracellular ROS levels and thus resulted in enhanced immunogenic cell death (ICD) of tumor cells. Upon being injected into the tumor cavity after resection, the in situ-generated NanoCD@Gel allowed the local release of CUR and DOX in a controlled manner to induce local chemotherapy and persistently activate the antitumor immune response, thereby achieving enhanced immunogenic chemotherapy with reduced systemic toxicity. Our work provides an elegant strategy for persistently stimulating effective antitumor immunity to prevent postsurgical tumor recurrence and metastasis.


Asunto(s)
Curcumina , Nanopartículas , Humanos , Curcumina/farmacología , Hidrogeles , Especies Reactivas de Oxígeno , Recurrencia Local de Neoplasia/tratamiento farmacológico , Recurrencia Local de Neoplasia/prevención & control , Línea Celular Tumoral , Doxorrubicina , Microambiente Tumoral
14.
Environ Res ; 233: 116355, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37329944

RESUMEN

Lead ions (Pb2+), as one of many common heavy metallic environmental pollutants, can cause serious side-effects and result in chronic poisoning to people's health, so it is highly significant to monitor Pb2+ efficiently and sensitively. Here, we proposed an antimonene@Ti3C2Tx nanohybrid-based electrochemical aptamer sensor (aptasensor) for high sensitive Pb2+ determination. The sensing platform of nanohybrid was synthesized by ultrasonication, possessing the advantages of both antimonene and Ti3C2Tx, which not only can vastly enlarge the sensing signal of the proposed aptasensor, but also greatly simplified its manufacturing flow, because antimonene can strongly interact with aptamer through noncovalently bound. The surface morphology and microarchitecture of the nanohybrid were perused by several methods such as scanning electron microscope (SEM), energy-dispersive X-ray mapping spectroscopy (EDS), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and atomic force microscope (AFM). Under optimal empirical conditions, the proposed aptasensor exhibited a wide linear correlation of the current signals with the logarithm of CPb2+ (Log CPb2+) over the span from 1 × 10-12 to 1 × 10-7 M and provided a trace discernment limit of 3.3 × 10-13 M. Moreover, the constructed aptasensor displayed superior repeatability, great consistency, eminent selectivity, and beneficial reproducibility, implying its extreme potential application for water quality control and the environmental monitoring of Pb2+.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Humanos , Plomo , Reproducibilidad de los Resultados , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas , Titanio , Límite de Detección
15.
Mikrochim Acta ; 190(2): 73, 2023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36695940

RESUMEN

An innovative strategy is proposed to simultaneously exfoliate multi-walled carbon nanotubes (MWCNTs) and generate MWCNTs with immunoaffinity properties. This strategy was based on the non-covalent functionalization of MWCNTs with human immunoglobulin G (IgG) by sonicating 2.5 mg mL-1 MWCNTs in 2.0 mg mL-1 IgG for 15 min with sonicator bath. Impedimetric experiments performed at glassy carbon electrodes (GCE) modified with the resulting MWCNT-IgG nanohybrid in the presence of anti-human immunoglobulin G antibody (Anti-IgG) demonstrated that the immunoglobulin retains their biorecognition properties even after the treatment during the MWCNT functionalization. We proposed, as proof-of-concept, two model electrochemical sensors, a voltammetric one for uric acid quantification by taking advantages of the exfoliated MWCNTs electroactivity (linear range, 5.0 × 10-7 M - 5.0 × 10-6 M; detection limit, 165 nM) and an impedimetric immunosensor for the detection of Anti-IgG through the use of the bioaffinity properties of the IgG present in the nanohybrid (linear range, 5-50 µg mL-1; detection limit, 2 µg mL-1).


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Humanos , Técnicas Biosensibles/métodos , Nanotubos de Carbono/química , Inmunoensayo , Inmunoglobulina G , Electrodos
16.
Mikrochim Acta ; 190(11): 427, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37792071

RESUMEN

The simple preparation of a nanohybrid of terbium-doped carbon dots/glutathione-capped copper nanoclusters (Tb@CDs/GSH-CuNCs) was for the first time developed for ratiometric detection of phosphate anion (Pi). Blue-emission of Tb@CDs can trigger non-luminescence of GSH-CuNCs for aggregation-induced emission (AIE) performance due to the strong reserved coordination capacity of Tb3+. Thus, Tb@CDs/GSH-CuNCs rapidly generated dual-emission signals at 630 nm and 545 nm by directly mixing the two individual materials via the AIE effect, alongside fluorescence resonance energy transfer (FRET) process. However, by the introduction of Pi, both AIE and FRET processes were blocked because of the stronger binding affinity of Tb3+ and Pi than that of Tb3+ and -COOH on Tb@CDs, thus realizing successful ratiometric detection of Pi. The linear concentration range was 0-16 µM, with the limit of detection (LOD) of 0.32 µM. The proposed method provided new ideas for designing nanohybrid of CDs and nanoclusters (MNCs) as ratiometric fluorescent probes for analytical applications.

17.
Bioprocess Biosyst Eng ; 46(12): 1755-1763, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37855914

RESUMEN

The non-enzymatic electrochemical sensors are attractive due to their high sensitivity, quick detection, low cost, and simple construction. Hence, in this work, a non-enzymatic biosensor was constructed with NiCo2O4 nanoparticles (~ 82 nm) decorated over Ti2NbC2 nanosheets by an in-situ method. The crystal structure, phase purity, morphology and elemental composition of the synthesized NiCo2O4/Ti2NbC2 nanohybrid was investigated using XRD, Raman and FESEM analysis. The electrocatalytic and electrochemical behaviour of the prepared nanohybrid was investigated using cyclic voltammetry and amperometry analysis. Hybrid of NiCo2O4/Ti2NbC2 produces a biocompatible, electrochemically active surface with enhanced electrical conductivity. The enhanced surface area of NiCo2O4 and superior electrical conductivity of Ti2NbC2 nanosheets helped to develop non-enzymatic electrochemical glucose sensor with enhanced sensitivity (425.6 µA mM-1cm-2), low limit of detection and quick response time that satisfy glucose detection applications. Thus, the developed non-enzymatic electrochemical glucose sensor has excellent electrochemical properties and making it as a strong candidate for the detection of glucose concentration in sweat.


Asunto(s)
Técnicas Biosensibles , Glucosa , Glucosa/análisis , Sudor/química , Técnicas Electroquímicas/métodos , Titanio , Técnicas Biosensibles/métodos , Electrodos
18.
Int J Mol Sci ; 24(24)2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38139068

RESUMEN

Carbon nanotubes (CNTs) have rapidly received increasing attention and great interest as potential materials for energy storage and catalyst fields, which is due to their unique physicochemical and electrical properties. With continuous improvements in fabrication routes, CNTs have been modified with various types of materials, opening up new perspectives for research and state-of-the-art technologies. Amorphous CNTs (aCNTs) are carbon nanostructures that are distinctively different from their well-ordered counterparts, such as single-walled and multi-walled carbon nanotubes (SWCNTs and MWCNTs, respectively), while the atoms in aCNTs are grouped in a disordered, crystalline/non-crystalline manner. Owing to their unique structure and properties, aCNTs are attractive for energy storage, catalysis, and aerospace applications. In this review, we provide an overview of the synthetic routes of aCNTs, which include chemical vapor deposition, catalytic pyrolysis, and arc discharge. Detailed morphologies of aCNTs and the systematic elucidation of tunable properties are also summarized. Finally, we discuss the future perspectives as well as associated challenges of aCNTs. With this review, we aim to encourage further research for the widespread use of aCNTs in industry.


Asunto(s)
Nanotubos de Carbono , Nanotubos de Carbono/química , Tecnología , Catálisis , Gases
19.
BMC Oral Health ; 23(1): 49, 2023 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-36710338

RESUMEN

BACKGROUND: Currently, the demands for restorations have increased considerably; thus, improvements and modifications have been made in dental composite technologies especially using materials that have been claimed to improve color stability. OBJECTIVE: This study aimed to determine the effect of various solutions on the color stability of different restorative materials in vitro study. METHODS: This study used three types of esthetic restorative materials. The samples comprised 45 discs, including 15 micro-hybrids, 15 nano-hybrids, and 15 glass ionomers). These discs were immersed in various beverages an hour a day for one month at room temperature. The color stability was measured using a spectrophotometer before/after immersion (days 7 and 30). RESULTS: We realized a significant difference in color change with Coca-Cola and tea-milk solution after seven days and 30 days (p < 0.05). However, no significant difference was found in the samples immersed in DM after seven days and 30 days (p > 0.05). The highest value of lightness (∆L) and stainability (∆a) was seen in micro-hybrid after 30 days of immersion in tea-milk solution (- 12.16 ± 1.74 and 11.4 ± 3.82, respectively), while most samples had a positive ∆b value. CONCLUSION: After one month, the tea-milk solution affected the color stability of all used restorative materials. In addition, micro-hybrid had higher color stability than nano-hybrid and glass ionomer.


Asunto(s)
Estética Dental , Inmersión , Humanos , Materiales Dentales , Bebidas , , Color , Ensayo de Materiales , Resinas Compuestas , Propiedades de Superficie
20.
BMC Oral Health ; 23(1): 55, 2023 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-36717844

RESUMEN

BACKGROUND: Safety issues for dental restorative composites are critical to material selection, but, limited information is available to dental practitioners. This study aimed to compare the chemical and biological characteristics of three nanohybrid dental composites by assessing filler particle analysis, monomer degree of conversion (DC), the composition of eluates, and cytotoxicity and reactive oxygen species (ROS) production in fibroblasts. METHODS: Three nanohybrid composites (TN, Tetric N-Ceram; CX, Ceram X Sphere Tec One; and DN, DenFil NX) were used. The size distribution and morphology of the filler particles were analysed using scanning electron microscopy (n = 5). The DC was measured via micro-Raman spectroscopy (n = 5). For the component analysis, methanol eluates from the light-polymerised composites were evaluated by gas chromatography/mass spectrometry (n = 3). The eluates were prepared from the polymerised composites after 24 h in a cell culture medium. A live/dead assay (n = 9) and Water-Soluble Tetrazolium-1 assay (n = 9) were performed and compared with negative and positive controls. The ROS in composites were compared with NC. Statistical significance in differences was assessed using a t-test and ANOVA (α = 0.05). RESULTS: Morphological variations in different-sized fillers were observed in the composites. The DC values were not significantly different among the composites. The amounts of 2-hydroxyethyl methacrylate (HEMA) were higher in TN than DN (p = 0.0022) and triethylene glycol dimethacrylate (TEGDMA) in CX was higher than in others (p < 0.0001). The lowest cell viability was shown in CX (p < 0.0001) and the highest ROS formation was detected in TN (p < 0.0001). CONCLUSIONS: Three nanohybrid dental composites exhibited various compositions of filler sizes and resin components, resulting in different levels of cytotoxicity and ROS production. Chemical compositions of dental composites can be considered with their biological impact on safety issues in the intraoral use of dental restorative composites. CX with the highest TEGDMA showed the highest cytotoxicity induced by ROS accumulation. DN with lower TEGDMA and HEMA presented the highest cell viability.


Asunto(s)
Odontólogos , Rol Profesional , Humanos , Especies Reactivas de Oxígeno , Resinas Compuestas/toxicidad , Resinas Compuestas/química , Metacrilatos , Ácidos Polimetacrílicos/química , Ensayo de Materiales , Bisfenol A Glicidil Metacrilato/toxicidad , Materiales Dentales/toxicidad , Materiales Dentales/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda