Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091338

RESUMEN

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Asunto(s)
Síndrome Coronario Agudo , Ácidos Alcanesulfónicos , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Trombosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Factores de Riesgo , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Implantes Absorbibles , Diseño de Prótesis , Fármacos Cardiovasculares/efectos adversos , Trombosis Coronaria/etiología , Stents/efectos adversos , Polímeros , Intervención Coronaria Percutánea/efectos adversos
2.
Herz ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656396

RESUMEN

BACKGROUND: This study aimed to evaluate the long-term outcomes of double kissing crush stenting (DKC) and mini-culotte technique (MCT) in patients with complex bifurcation lesions. METHODS: This retrospective study enrolled 236 patients who underwent percutaneous coronary intervention (PCI) for complex coronary bifurcation disease between January 2014 and November 2022. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). The secondary endpoint was major cardiovascular and cerebral events (MACCE) including all-cause death, MI, TLR, stroke, or stent thrombosis. The regression models were adjusted by applying the inverse probability weighted (IPW) approach to reduce treatment selection bias. RESULTS: The initial management strategy was DKC in 154 (65.3%) patients and MCT in 82 (34.7%) patients (male: 194 [82.2%], mean age: 60.85 ± 10.86 years). The SYNTAX scores were similar in both groups. The rates of long-term TLF and MACCE rates were 17.4% and 20%, respectively. The rate of TLF (26.8% vs. 12.3%, p = 0.005) was higher in patients treated with MCT than those treated with the DKC technique, mainly driven by more frequent TLR (15.9% vs. 7.1%, p = 0.035). The long-term TLF and MACCE rates were notably lower in the DKC group compared to the others: adjusted hazard ratio (HR; IPW): 0.407, p = 0.009 for TLF, and adjusted HR(IPW): 0.391 [95% CI: 0.209-0.730], p = 0.003 for MACCE. CONCLUSION: At long-term follow-up, the rates of TLF and MACCE were 17.4% and 20%, respectively. However, long-term TLF was significantly higher in patients treated with MCT than those treated with the DKC technique, primarily due to a more frequent occurrence of clinically driven TLR.

3.
Cardiovasc Diabetol ; 22(1): 283, 2023 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-37865782

RESUMEN

BACKGROUND: Early diagnosis and treatment effectiveness of early-onset coronary artery disease (EOCAD) are crucial, and non-invasive predictive biomarkers are needed for young adults. We aimed to evaluate the usefulness of the triglyceride-glucose (TyG) index, a novel marker of insulin resistance, in identifying young CAD patients and predicting their risk of developing target lesion failure (TLF). METHODS: We recruited EOCAD patients (luminal narrowing ≥ 70%) and controls free from CAD (luminal narrowing < 30%), both aged 45 years or younger, from 38 hospitals in China between 2017 and 2020. EOCAD patients who underwent successful percutaneous coronary intervention were followed for incident TLF. TyG index was defined as Ln [fasting triglyceride (mg/dL) × fasting blood glucose (mg/dL)/2]. We used logistic regression and Cox proportional hazards modeling to evaluate the association of TyG index with prevalent EOCAD and incident TLF, respectively. The discriminatory ability of TyG index was assessed by the area under the receiver-operating characteristic curve (AUC). RESULTS: Among the included 1513 EOCAD patients (39.6 ± 4.4 years, 95.4% male) and 1513 age-matched controls (39.0 ± 4.4 years, 46.4% male), TyG index was positively associated with the prevalence of EOCAD (adjusted odds ratio: 1.40, 95% confidence interval [CI] 1.23-1.60, per standard deviation [SD] increase in TyG index). The addition of TyG index to an empirical risk model provided an improvement in diagnostic ability for EOCAD, with a net reclassification improvement of 0.10 (95% CI 0.03-0.17, p = 0.005). During a medium of 33 month (IQR: 31-34 months) follow-up, 43 (3.3%) patients experienced TLF. Multivariate Cox regression model revealed that TyG index was an independent risk factor for TLF (adjusted hazard ratio [HR]: 2.410, 95% CI 1.07-5.42 comparing the top to bottom TyG index tertile groups; HR: 1.30, 95% CI 1.01-1.73, per SD increase in TyG index). Compared with a model of conventional risk factors alone, the addition of the TyG index modestly improved the AUC (0.722-0.734, p = 0.04) to predict TLF. CONCLUSIONS: TyG index is positively associated with prevalent EOCAD and incident TLF. TyG index appeared to be a valuable component of future efforts to improve CAD risk stratification and TLF outcome prediction among young adults.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Humanos , Masculino , Adulto Joven , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/terapia , Glucosa , Glucemia , Triglicéridos , Factores de Riesgo , Biomarcadores , Medición de Riesgo
4.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076703

RESUMEN

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

5.
Rev Cardiovasc Med ; 24(2): 53, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077417

RESUMEN

Background: In patients undergoing percutaneous coronary intervention (PCI), drug eluting stents (DES) are currently the standard of care. Stent design and alloy composition, biocompatibility of the drug-eluting polymer coating, the antiproliferative agent properties and release are the three main characteristics that affects DES performance. Cre8 (Alvimedica, Istanbul, Turkey) is a polymer-free amphilimus-eluting stents (PF-AES). In this study, we aimed to investigate the clinical efficacy and safety of Cre8 DES in daily cardiology practice. Methods: Patients presenting with chronic coronary syndrome (CCS) or acute coronary syndrome (ACS) including unstable angina pectoris (USAP), myocardial infarction with and without ST-segment elevation and treated with PCI using Cre8 DES between December 2015 and 2016 were retrospectively analyzed in this study. Results: Between December 2015 and 2016, 808 lesions of 664 patients treated with Cre8 DES in a single center were included in this retrospective analysis. The mean age of study group was 60 years (between 33 and 93 years) and were predominantly consisting of male patients (79.4%). The median follow-up duration was 487 days (min: 30 days, max: 919 days) and two-thirds of all patients presented with ACS. The culprit lesion was on left anterior descending artery (LAD) (40.5%) and right coronary artery (RCA) (25.9%) in most of the patients. The procedural success rate was 97.3%. Most of the lesions were type B1 (40.6%) according to American College of Cardiology/American Heart Association (ACC/AHA) coronary lesion classification. The device oriented primary end-point defined as target lesion failure (TLF) occurred in 52 (6.4%) of 808 lesions. The primary safety end-point was cardiac death in 20 patients (3.0%) and target vessel myocardial infarction in 2 patients (0.3%). Target vessel revascularization (TVR) occurred in 29 patients (4.4%) as primary safety endpoint. Multivariable logistic regression analysis revealed diabetes mellitus and ejection fraction as the predictors of mortality and device oriented primary end-point. Conclusions: This trial revealed clinical efficacy and safety of Cre8 stents in real world practice. Device oriented primary end points were similar with previous studies which are randomized, open label in nature and showed the efficacy and safety of Cre8 stent towards latest generation DES.

6.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378691

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Asunto(s)
Síndrome Coronario Agudo , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Factores de Tiempo , Diseño de Prótesis , Infarto del Miocardio/etiología , Stents Liberadores de Fármacos/efectos adversos
7.
BMC Cardiovasc Disord ; 23(1): 496, 2023 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-37805479

RESUMEN

BACKGROUND: Cell division control 42 (CDC42) regulates atherosclerosis, blood lipids, and inflammation and thus affects coronary artery disease (CAD), but its utility in drug-coated balloon (DCB)-treated small-vessel CAD (SV-CAD) patients is unclear. This study intended to evaluate the change and prognostic role of CDC42 in SV-CAD patients underwent DCB. METHODS: Serum CDC42 was measured by enzyme-linked immunosorbent assay in 211 SV-CAD patients underwent DCB at baseline, day (D) 1, D3, and D7, as well as in 50 healthy controls (HCs). RESULTS: CDC42 was decreased in SV-CAD patients compared to HCs (P < 0.001), and it was negatively associated with total cholesterol (P = 0.015), low-density lipoprotein cholesterol (P = 0.003), C-reactive protein (P = 0.001), multivessel disease (P = 0.020), and American college of cardiology/American heart association type B2/C lesions (P = 0.039) in SV-CAD patients. Longitudinally, CDC42 decreased from baseline to D1 and then gradually increased to D7 (P < 0.001) in SV-CAD patients after DCB. Interestingly, high CDC42 (cut-off value = 500 pg/mL) at baseline (P = 0.047), D3 (P = 0.046), and D7 (P = 0.008) was associated with a lower accumulating target lesion failure (TLF) rate; high CDC42 at D3 (P = 0.037) and D7 (P = 0.041) was related to a lower accumulating major adverse cardiovascular event (MACE) rate in SV-CAD patients underwent DCB. Importantly, CDC42 at D7 (high vs. low) independently predicted lower accumulating TLF (hazard ratio (HR) = 0.145, P = 0.021) and MACE (HR = 0.295, P = 0.023) risks in SV-CAD patients underwent DCB. CONCLUSIONS: Circulating CDC42 level relates to milder disease conditions and independently estimates lower risks of TLF and MACE in SV-CAD patients underwent DCB, but further validation is still needed.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Colesterol
8.
Cardiovasc Diabetol ; 21(1): 220, 2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36307791

RESUMEN

BACKGROUND: Diabetes mellitus (DM) and cardiovascular diseases often co-exist. Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of patients with coronary artery disease. Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of drug-eluting stents. In this analysis, we aimed to systematically compare the cardiovascular outcomes which are associated with polymer-free amphilimus-eluting stents (AES) versus the durable polymer zotarolimus-eluting stents (ZES) for the treatment of patients with DM. METHODS: Http://www. CLINICALTRIALS: gov, EMBASE, Web of Science, MEDLINE, Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM. Selective cardiovascular outcomes were assessed. Statistical analysis was carried out by the latest version of the RevMan software. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis. RESULTS: Four studies with a total number of 1795 participants with DM whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES were included in this analysis. In patients with DM, at one year, polymer-free AES were associated with significantly lower risk of major adverse cardiac events (MACEs) (RR: 0.69, 95% CI: 0.54-0.88; P = 0.002) and target lesion failure (TLF) (RR: 0.66, 95% CI: 0.48-0.91; P = 0.01) compared to durable polymer ZES. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51-1.22; P = 0.28), cardiac death and the other cardiovascular outcomes. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60-2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38-3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37-2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50-2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17-5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM. CONCLUSIONS: At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Fármacos Cardiovasculares/efectos adversos , Factores de Riesgo , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/inducido químicamente , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 99(7): 1965-1975, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35384254

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Antígenos CD34/inmunología , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Muerte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sirolimus/efectos adversos , Stents , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 99(3): 563-574, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34236755

RESUMEN

OBJECTIVE: Identify the effect of ultrathin drug eluting stents on long term outcomes in coronary artery disease. BACKGROUND: Although second-generation drug eluting stents (DES) are superior to first-generation DES, persistence of adverse outcomes has led to continued refinement in design. Ultrathin second-generation DES have been shown to improve outcomes at 1-year follow-up. Beyond 1-year their effect remains unknown. METHODS: PubMed, Embase and Cochrane Database were searched for randomized controlled trials that compared ultrathin (defined as <70 um) to standard thickness second-generation DES. Studies were chosen according to the PROSPERO protocol (CRD42020185374). Data from randomized controlled trials were pooled using random-effects model (Mantel-Haenszel). The primary outcome was target lesion failure (TLF) at 2 years, a composite of cardiac death, target vessel myocardial infarction, and ischemia-driven target vessel revascularization. Secondary outcomes included TLF at 3 and 5 years, the components of TLF and definite or probable stent thrombosis. Differences in outcomes between groups were presented in Forest plots as risk ratios (RR) with corresponding 95% confidence intervals (CIs) for each trial. RESULTS: We identified 18 publications from 10 trials with14,649 patients. At 2-years there was a significant 12% reduction in TLF (RR, 0.88; 95% CI 0.78-0.99; p < 0.05) associated with the use of ultrathin DES. At 3-years, there was a significant 19% reduction in TLF with ultrathin DES (RR, 0.79; 95% CI 0.64-0.98; p < 0.05). CONCLUSION: In patients undergoing percutaneous coronary intervention, ultrathin DES improve long term clinical outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 98(5): 848-856, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32890442

RESUMEN

OBJECTIVES: This analysis of pooled individual patient data (IPD) aimed to evaluate the safety and efficacy of a bioresorbable polymer sirolimus eluting stent system (BP-SES; Orsiro) compared to a durable polymer everolimus eluting stent system (DP-EES; Xience) in the pooled population as well as in subgroups. METHODS: IPD with up to 12 months follow-up of the randomized controlled trials BIOFLOW-II (NCT01356888), -IV (NCT01939249), and -V (NCT02389946) as well as the all comers registry BIOFLOW-III (NCT01553526) were pooled. A total of 3,717 subjects (2,923 in BP-SES and 794 in DP-EES) with 5,328 lesions (4,225 lesions in BP-SES and 1,103 in DP-EES) were included in the IPD. The primary endpoint was target lesion failure (TLF) at 12 months follow-up. Subgroups analyzed included diabetes, age (≥65 years), gender, complex lesions (B2/C), small vessels (reference vessel diameter ≤2.75 mm), multivessel treatment, renal disease, and patients with acute coronary syndrome. RESULTS: Overall, TLF at 12 months was significantly lower with 5.2%in the BP-SES group versus 7.6% in the DP-EES group (p = .0098). Similarly, target vessel myocardial infarction (TV-MI) was 3.1 versus 5.7% (p = .0005). The rate of stent thrombosis was similar in both groups (0.004%). By regression analysis, an independent stent effect in favor of BP-SES was observed for TLF (p = .0043) and TV-MI (p = .0364) in small vessels. CONCLUSION: Results of this IPD analysis suggest that the BP-SES with ultrathin struts is as safe as and more efficacious than DP-EES in the overall cohort and especially in small vessels.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Everolimus , Sirolimus , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Análisis de Datos , Stents Liberadores de Fármacos/efectos adversos , Everolimus/efectos adversos , Humanos , Polímeros , Diseño de Prótesis , Sirolimus/efectos adversos , Resultado del Tratamiento
12.
BMC Cardiovasc Disord ; 21(1): 537, 2021 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-34772347

RESUMEN

OBJECTIVES: To evaluate the 3-year clinical outcomes of a polymer-free sirolimus-eluting, Nano plus stent for the treatment of coronary artery disease in the NANO multicenter Registry. BACKGROUND: The long-term clinical data evaluating the safety and efficacy of the novel polymer-free sirolimus-eluting Nano plus stent (Lepu Medical, Beijing, China) is limited. METHODS: The NANO all-comers Registry trial was a prospective, multicenter clinical registry conducted in 26 centers in China between August 2016 and January 2017. A total of 2481 consecutive patients were exclusively treated with the Nano plus stent. The primary clinical endpoint, target lesion failure (TLF, defined as cardiac death, target vessel nonfatal myocardial infarction, and clinically driven target lesion revascularization [CD-TLR]), was analyzed at 3 years. RESULTS: At 3 years, 2295 patients (92.5%) were followed. The incidence of TLF was 6.8% (168/2481). The rate of cardiac death was 3.8% (94/2481), target vessel nonfatal myocardial infarction 0.7% (18/2481), and CD-TLR 2.9% (68/2481). The rate of definite/probable stent thrombosis was 0.5% (13/2481). The risk factors of diabetes mellitus, acute myocardial infarction, age, chronic renal failure, in-stent restenosis, chronic total occlusion, and left ventricular ejection fraction < 40% were the independent predictors of 3-year TLF. CONCLUSIONS: At three years, the rate of TLF was relatively low in patients treated with the polymer-free Nano plus stent. The polymer-free Nano plus stent showed a favorable safety and efficacy profile in real-world patients. Clinical trial registration URL: https://www.clinicaltrials.gov/ . Unique identifier: NCT02929030.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , China , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Polímeros , Estudios Prospectivos , Falla de Prótesis , Sistema de Registros , Insuficiencia del Tratamiento
13.
Eur Heart J ; 41(27): 2523-2536, 2020 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-32588060

RESUMEN

AIM: The present study aimed to assess the benefits of two-stent techniques for patients with DEFINITION criteria-defined complex coronary bifurcation lesions. METHODS AND RESULTS: In total, 653 patients with complex bifurcation lesions at 49 international centres were randomly assigned to undergo the systematic two-stent technique (two-stent group) or provisional stenting (provisional group). The primary endpoint was the composite of target lesion failure (TLF) at the 1-year follow-up, including cardiac death, target vessel myocardial infarction (TVMI), and clinically driven target lesion revascularization (TLR). The safety endpoint was definite or probable stent thrombosis. At the 1-year follow-up, TLF occurred in 37 (11.4%) and 20 (6.1%) patients in the provisional and two-stent groups, respectively [77.8%: double-kissing crush; hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.30-0.90; P = 0.019], largely driven by increased TVMI (7.1%, HR 0.43, 95% CI 0.20-0.90; P = 0.025) and clinically driven TLR (5.5%, HR 0.43, 95% CI 0.19-1.00; P = 0.049) in the provisional group. At the 1 year after indexed procedures, the incidence of cardiac death was 2.5% in the provisional group, non-significant to 2.1% in the two-stent group (HR 0.86, 95% CI 0.31-2.37; P = 0.772). CONCLUSION: For DEFINITION criteria-defined complex coronary bifurcation lesions, the systematic two-stent approach was associated with a significant improvement in clinical outcomes compared with the provisional stenting approach. Further study is urgently warranted to identify the mechanisms contributing to the increased rate of TVMI after provisional stenting. STUDY REGISTRATION: http://www.clinicaltrials.com; Identifier: NCT02284750.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Stents , Factores de Tiempo , Resultado del Tratamiento
14.
Acta Cardiol Sin ; 37(5): 484-495, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34584381

RESUMEN

BACKGROUND: Treating vessels with a very small reference vessel diameter (RVD) in coronary artery disease is challenging. OBJECTIVE: Long-term evaluation of new-generation drug-eluting stents (DESs) for the treatment of coronary lesions with different RVDs. METHODS: From April 2009 to March 2019, 780 patients who underwent single coronary stenting were divided into ≤ 2.25 (very small), 2.5-3.0 (small), and ≥ 3.5 mm (large) DES groups after 1:2:2 propensity score matching. The primary endpoint was target lesion failure (TLF), and the secondary endpoints were major adverse cardiac events (MACEs) and stent thrombosis (ST). RESULTS: During 3 years after new-generation DES implantation, TLF and MACE rates were significantly lower in the very small DES group. The risk of TLF was significantly lower in the very small DES group compared to the small DES group [very small vs. small: TLF, adjusted hazard ratio (HR) = 0.282, p = 0.040]. The risks of MACEs and all-cause mortality were significantly lower in the very small DES group compared to the small DES group (very small vs. small: MACEs, adjusted HR = 0.215, p = 0.001; all-cause mortality, adjusted HR = 0.181, p = 0.005). The cumulative incidence rates of TLF-free (log-rank test p = 0.001) and MACE-free (log-rank test p < 0.001) survival were significantly different among the groups, and the very small DES group had a high event-free survival rate. No cases of ST occurred in any group. CONCLUSIONS: Our results indicate that the use of new-generation DESs for treating coronary lesions in very small vessels is safe and effective.

15.
Catheter Cardiovasc Interv ; 95 Suppl 1: 558-564, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31909861

RESUMEN

OBJECTIVE: This study sought to assess whether the predilation, scaffold/stent sizing, and postdilation (PSP) score for bioresorbable scaffold (BRS) implantation was associated with outcomes following metallic drug-eluting stent (DES) implantation. BACKGROUND: The PSP score is associated with patients' prognoses after BRS implantation. METHODS: This study involved 2,348 patients who underwent biodegradable polymer DES implantations during the PANDA III trial. The optimal PSP technique was defined according to previous studies of BRS implantations. The main outcome was target lesion failure (TLF) that comprised cardiac death, target-vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: Twenty-five (1.1%) patients fulfilled all the PSP criteria. The BRS-derived PSP score was of limited prognostic value for 2-year TLF after metallic DES implantation; optimal sizing was a protective factor, but optimal predilation was a risk factor. We built a new PSP model for DESs by identifying the following risk factors: predilation performed with a residual stenosis ≥70% or a balloon-to-quantitative coronary angiography (QCA)-determined reference vessel diameter (RVD) ratio >1:1, sizing performed with an RVD <2.25 mm or a stent diameter >0.25 mm wider than the QCA-RVD, a postprocedural stenosis diameter ≥30%, age, and the baseline SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery (SYNTAX) score. The new PSP scoring system predicted 2-year TLF (area under the curve, 0.69; 95% confidence interval, 0.65-0.73); a cutoff value of 19.2 points identified high-risk patients. CONCLUSIONS: The new PSP scoring system, based on redefined PSP criteria, age, and the SYNTAX score, could help optimize metallic DES implantations.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Stents Liberadores de Fármacos , Metales , Isquemia Miocárdica/terapia , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 95 Suppl 1: 658-664, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31961057

RESUMEN

OBJECTIVES: We aimed to evaluate the safety and efficacy of Nano+™ (Lepu Medical, Beijing, China) stent implantation in all-comer patients at the 1-year follow-up. BACKGROUND: The Nano+™ stent is a novel polymer-free sirolimus-eluting stent polymer that employs nanoporous stent surface technology to control drug-delivery. The Nano+™ stent is one of the most widely used drug-eluting stent (DES) in China. METHODS: A total of 2,481 consecutive patients were included in the multicenter and prospective NANO registry. In this study, the primary endpoint was target lesion failure (TLF) at 1-year follow-up, defined as a composite of cardiac death, target vessel nonfatal myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR). The safety endpoint was the occurrence of definite or probable stent thrombosis (ST). RESULTS: Up to 40.2% of patients presented with acute myocardial infarction (AMI). A total of 63.9% of the 2,904 lesions were American College of Cardiology/American Heart Association (ACC/AHA) type B2 or C lesions. One-year follow-up data were available for 98.4% of patients. The 1-year rate of TLF was 3.1% with rates of 1.3, 1.8, and 0.4% for clinically driven TLR, cardiac death, and TV-MI, respectively. ST occurred in 0.4% of patients. Diabetes mellitus, AMI, left ventricular ejection fraction <40% and long lesions (>40 mm) were independent predictors of 1-year TLF. CONCLUSIONS: The 1-year clinical outcomes were excellent for Nano+™ polymer-free SES implantation in an all-comer patient population. Follow-up will be extended up to 5 years, to further elucidate the potential long-term clinical benefits. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02929030.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , China , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nanoporos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Sirolimus/efectos adversos , Propiedades de Superficie , Factores de Tiempo , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 93(4): 567-573, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244533

RESUMEN

OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared. BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention. METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years. RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95). CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 92(6): 1097-1103, 2018 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-29513378

RESUMEN

OBJECTIVES: To evaluate the target lesion failure (TLF) rate of the SYNERGY stent in all-comers, multiethnic Asian population. BACKGROUND: Currently, most drug eluting stents deliver anti-proliferative drugs from a durable polymer which is associated with a risk of late stent thrombosis. The novel everolimus-eluting, platinum chromium SYNERGY stent is coated with a bioabsorbable abluminal polymer that resolves within 4 months. METHODS: This was a prospective, single center registry of consecutive patients treated with the SYNERGY stent between December 2012 and April 2015. The primary outcome was the incidence of TLF, defined as the combination of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization (TLR) at 1 year. RESULTS: A total of 807 patients received the SYNERGY stent during the study period. One-year clinical outcome data was available for 765 patients (94.8%) and were considered for statistical analysis. The mean age was 60.7 ± 10.8 years, and 83.4% were males. Patients with acute myocardial infarction consisted of 50.3% (ST-segment elevation myocardial infarction: 23.0%, Non-ST-segment elevation myocardial infarction: 27.3%) of the study population. The treated lesions were complex (ACC/AHA type B2/C: 72.7%). The primary end point of TLF at 1 year was 5.8%. Rates of cardiac mortality, target vessel myocardial infarction, and TLR were 4.2, 1.0, and 1.3%, respectively, at 1 year. Predictors of the incidence and time to early TLF were female gender, Malay ethnicity, diabetes mellitus, acute myocardial infarction at presentation, a prior history of coronary artery bypass surgery and the presence of lesion calcification. The incidence of definite stent thrombosis was 0.4% at 1 year. CONCLUSIONS: In this registry, the use of the SYNERGY stent was associated with low rates of TLF at 1 year.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Pueblo Asiatico , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etnología , Enfermedad de la Arteria Coronaria/mortalidad , Everolimus/administración & dosificación , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etnología , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Singapur/epidemiología , Factores de Tiempo , Insuficiencia del Tratamiento
19.
Catheter Cardiovasc Interv ; 92(7): E493-E501, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29774986

RESUMEN

OBJECTIVES: To assess the efficacy and safety of the Xience Prime everolimus-eluting stent (EES) in long coronary lesions in a real-world population. BACKGROUND: Long lesions are considered difficult technically and in terms of achieving successful clinical outcomes. With first generation DES, MACE can be as high as 10% at a short-medium term follow-up. There are a few data available in this subset regarding the use of second generation DES METHODS: A prospective, multicenter registry of consecutive patients (aged 64.8 ± 11.2 years, 77% men and 33% diabetics) in 29 tertiary hospitals with de novo > 24 mm lesions in vessels of 2.25-4 mm was performed. The primary and secondary endpoints were major adverse cardiac events (MACE; cardiac death, myocardial infarction, and target lesion revascularization) and stent thrombosis (ST) at 1, 12, and 24 months. Patients were on dual antiplatelet therapy during 12 months. RESULTS: A total of 610 patients with 705 long lesions were included (1.2 per patient). Lesion length was 34.59 ± 11.17 mm and vessel size 2.93 ± 0.41 mm. Stented length was 39.83 ± 14.08 mm (1.4 stents per lesion). Predilatation/postdiltatation was performed in 75 and 33% of the cases, intravascular ultrasound in 15%. The device success rate was 99.1%. MACE and ST rates at 1, 12, and 24-months follow-up were 0.3, 2.1, and 5.4% and 0.2, 0.7, and 1.5%, respectively. CONCLUSION: In this real-world population, the Xience Prime EES performs extremely well in long lesions, with a very low rate of both MACE and ST.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 90(1): 78-86, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28295926

RESUMEN

OBJECTIVE: The objective of this study was to clarify the incidence and predictors of early and late target lesion revascularization (TLR) after everolimus-eluting stent (EES) implantation in actual clinical practice. BACKGROUND: Several clinical studies have reported the incidence and predictors of TLR after EES implantation. However, detailed features of early and late TLR are unknown. METHODS: We analyzed the clinical data of patients who underwent EES implantation between January 2010 and December 2011 at 22 institutions in Japan (Tokyo-MD PCI study). Patients who underwent ischemia-driven TLR (ID-TLR) were grouped according to the number of years elapsed since stent placement, and incidence and correlations between clinical factors were analyzed. RESULTS: Statistical analysis was performed for 1,899 patients and 2,305 lesions. The mean age was 70.0 ± 9.9 years, and the median follow-up period was 1,281 days (IQR: 762-1,440 days). The incidence of ID-TLR was 2.7% at 1 year and 5.4% at 4 years. After 2 years, the ID-TLR rates plateaued. The independent predictors of ID-TLR occurring within 2 years were hemodialysis, triple vessel disease, restenotic lesion, and ostial lesions. The independent predictors of ID-TLR between 2 and 4 years were diabetes mellitus and peripheral artery disease. CONCLUSION: The ID-TLR rates leveled off after 2 years. Furthermore, the predictors of ID-TLR that occurred within 2 years of EES implantation differed from those that occurred later than 2 years. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tokio/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda