Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 16.044
Filtrar
Más filtros

Colección SES
Publication year range
1.
Proc Natl Acad Sci U S A ; 120(39): e2309822120, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37725651

RESUMEN

External control of chemical reactions in biological settings with spatial and temporal precision is a grand challenge for noninvasive diagnostic and therapeutic applications. While light is a conventional stimulus for remote chemical activation, its penetration is severely attenuated in tissues, which limits biological applicability. On the other hand, ultrasound is a biocompatible remote energy source that is highly penetrant and offers a wide range of functional tunability. Coupling ultrasound to the activation of specific chemical reactions under physiological conditions, however, remains a challenge. Here, we describe a synergistic platform that couples the selective mechanochemical activation of mechanophore-functionalized polymers with biocompatible focused ultrasound (FUS) by leveraging pressure-sensitive gas vesicles (GVs) as acousto-mechanical transducers. The power of this approach is illustrated through the mechanically triggered release of covalently bound fluorogenic and therapeutic cargo molecules from polymers containing a masked 2-furylcarbinol mechanophore. Molecular release occurs selectively in the presence of GVs upon exposure to FUS under physiological conditions. These results showcase the viability of this system for enabling remote control of specific mechanochemical reactions with spatiotemporal precision in biologically relevant settings and demonstrate the translational potential of polymer mechanochemistry.


Asunto(s)
Fuentes Generadoras de Energía , Polímeros , Transductores , Extremidad Superior
2.
Proc Natl Acad Sci U S A ; 119(12): e2113645119, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35294287

RESUMEN

Acute nociception is essential for survival by warning organisms against potential dangers, whereas tissue injury results in a nociceptive hypersensitivity state that is closely associated with debilitating disease conditions, such as chronic pain. Transient receptor potential (Trp) ion channels expressed in nociceptors detect noxious thermal and chemical stimuli to initiate acute nociception. The existing hypersensitivity model suggests that under tissue injury and inflammation, the same Trp channels in nociceptors are sensitized through transcriptional and posttranslational modulation, leading to nociceptive hypersensitivity. Unexpectedly and different from this model, we find that in Drosophila larvae, acute heat nociception and tissue injury-induced hypersensitivity involve distinct cellular and molecular mechanisms. Specifically, TrpA1-D in peripheral sensory neurons mediates acute heat nociception, whereas TrpA1-C in a cluster of larval brain neurons transduces the heat stimulus under the allodynia state. As a result, interfering with synaptic transmission of these brain neurons or genetic targeting of TrpA1-C blocks heat allodynia but not acute heat nociception. TrpA1-C and TrpA1-D are two splicing variants of TrpA1 channels and are coexpressed in these brain neurons. We further show that Gq-phospholipase C signaling, downstream of the proalgesic neuropeptide Tachykinin, differentially modulates these two TrpA1 isoforms in the brain neurons by selectively sensitizing heat responses of TrpA1-C but not TrpA1-D. Together, our studies provide evidence that nociception and noncaptive sensitization could be mediated by distinct sensory neurons and molecular sensors.


Asunto(s)
Nocicepción , Canales de Potencial de Receptor Transitorio , Animales , Drosophila/fisiología , Neuronas , Nocicepción/fisiología , Nociceptores/fisiología , Transductores , Canales de Potencial de Receptor Transitorio/genética
3.
Nano Lett ; 24(42): 13147-13152, 2024 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-39319575

RESUMEN

Electrophysiological recordings from brain cells are performed routinely using implanted electrodes, but they traditionally require a wired connection to the outside of the brain. A completely passive, wireless device that does not require on-board power for active transmission but that still facilitates remote detection could open the door for mass-scale direct recording of action potentials and transform the way we acquire brain signals. We present a nanofabricated coil that forms a neuroelectromagnetic junction, yielding a highly enhanced magnetic field transduction of electrophysiology. We show that this micrometer-scale device enables remote magnetic detection of neuronal fields from the center of the coil using room temperature superconducting quantum interference device (SQUID) microscopy. Further, time-locked stimulation in conjunction with magnetometry demonstrates thresholding behavior that affirms the viability of the technology for detection with no requirement for wires or on-board power. This strategy may permit unprecedented detection of electrophysiology using magnetoencephalography and magnetic resonance imaging.


Asunto(s)
Neuronas , Neuronas/fisiología , Potenciales de Acción/fisiología , Encéfalo/fisiología , Encéfalo/diagnóstico por imagen , Transductores , Magnetoencefalografía/instrumentación , Magnetoencefalografía/métodos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/instrumentación , Animales , Diseño de Equipo , Nanotecnología/instrumentación
4.
Magn Reson Med ; 92(1): 389-405, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38342981

RESUMEN

PURPOSE: There are 118 known elements. Nearly all of them have NMR active isotopes and at least 39 different nuclei have biological relevance. Despite this, most of today's MRI is based on only one nucleus-1H. To facilitate imaging all potential nuclei, we present a single transmit coil able to excite arbitrary nuclei in human-scale MRI. THEORY AND METHODS: We present a completely new type of RF coil, the Any-nucleus Distributed Active Programmable Transmit Coil (ADAPT Coil), with fast switches integrated into the structure of the coil to allow it to operate at any relevant frequency. This coil eliminates the need for the expensive traditional RF amplifier by directly converting direct current (DC) power into RF magnetic fields with frequencies chosen by digital control signals sent to the switches. Semiconductor switch imperfections are overcome by segmenting the coil. RESULTS: Circuit simulations demonstrated the effectiveness of the ADAPT Coil approach, and a 9 cm diameter surface ADAPT Coil was implemented. Using the ADAPT Coil, 1H, 23Na, 2H, and 13C phantom images were acquired, and 1H and 23Na ex vivo images were acquired. To excite different nuclei, only digital control signals were changed, which can be programmed in real time. CONCLUSION: The ADAPT Coil presents a low-cost, scalable, and efficient method for exciting arbitrary nuclei in human-scale MRI. This coil concept provides further opportunities for scaling, programmability, lowering coil costs, lowering dead-time, streamlining multinuclear MRI workflows, and enabling the study of dozens of biologically relevant nuclei.


Asunto(s)
Diseño de Equipo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Imagen por Resonancia Magnética/instrumentación , Humanos , Procesamiento de Señales Asistido por Computador , Análisis de Falla de Equipo , Transductores
5.
J Vasc Res ; 61(5): 252-259, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39074454

RESUMEN

INTRODUCTION: Current microvascular assessments may not be practical or accessible requiring experienced personnel and/or ongoing equipment costs. Piezoelectric transducers can reliably obtain finger blood pressure waves, similar to peripheral arterial tonometry devices; thus, they could be used to estimate microvascular function. We aimed to validate piezoelectric transducers as an alternative measure of microvascular function compared to EndoPAT. METHODS: Twenty-five adults (aged 20-64 years) completed reactive hyperemia (5 min forearm circulatory occlusion and 3 min recovery) with piezoelectric transducers on the middle fingers and EndoPAT probes on the index fingers. Average area under the curve (AUC) of the pulse wave signal for the occluded and control arms was determined at baseline, every 30 s post-occlusion, and 10 s around the peak response. Microvascular function index (MFI) was calculated as the ratio of AUC post-occlusion to AUC baseline in the test arm, then normalized to the same ratio in the control arm. MFI at each time point was correlated with the reactive hyperemia index (RHI) from the EndoPAT. RESULTS: The greatest significance was found between RHI and MFI at 10 s around the peak response (Spearman's r = 0.67, p = 0.0002; Pearson's r = 0.76, p = 0.00001). CONCLUSION: MFI is a reusable and user-friendly microvascular function assessment that could provide better access to vascular health screening.


Asunto(s)
Análisis Costo-Beneficio , Diseño de Equipo , Dedos , Hiperemia , Microcirculación , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Humanos , Adulto , Persona de Mediana Edad , Masculino , Femenino , Hiperemia/fisiopatología , Adulto Joven , Dedos/irrigación sanguínea , Proyectos Piloto , Transductores , Reproducibilidad de los Resultados , Factores de Tiempo , Análisis de la Onda del Pulso/instrumentación , Velocidad del Flujo Sanguíneo
6.
Opt Lett ; 49(11): 3054-3057, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824326

RESUMEN

Photoacoustic imaging (PAI) utilizes the photoacoustic effect to record both vascular and functional characteristics of a biological tissue. Photoacoustic signals have typically low amplitude that cannot be read efficiently by data acquisition systems. This necessitates the use of one or more amplifiers. These amplifiers are somewhat bulky (e.g., the ZFL-500LN+, Mini-Circuits, USA, or 351A-3-50-NI, Analog Modules Inc., USA). Here, we describe the fabrication and development process of a transducer with a built-in low-noise preamplifier that is encased within the transducer housing. This new, to the best of our knowledge, design could be advantageous for applications where a compact transducer + preamplifier is required. We demonstrate the performance of this compact detection unit in a laser scanning photoacoustic microscopy system by imaging a rat ear ex vivo and a rat brain vasculature in vivo.


Asunto(s)
Diseño de Equipo , Técnicas Fotoacústicas , Transductores , Técnicas Fotoacústicas/instrumentación , Técnicas Fotoacústicas/métodos , Animales , Ratas , Miniaturización , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Oído/diagnóstico por imagen , Oído/irrigación sanguínea , Amplificadores Electrónicos
7.
J Vasc Interv Radiol ; 35(6): 900-908.e2, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38508448

RESUMEN

PURPOSE: To develop a noninvasive therapeutic approach able to alter the biophysical organization and physiology of the extracellular matrix (ECM) in breast cancer. MATERIALS AND METHODS: In a 4T1 murine model of breast cancer, histoplasty treatment with a proprietary 700-kHz multielement therapy transducer using a coaxially aligned ultrasound (US) imaging probe was used to target the center of an ex vivo tumor and deliver subablative acoustic energy. Tumor collagen morphology was qualitatively evaluated before and after histoplasty with second harmonic generation. Separately, mice bearing bilateral 4T1 tumors (n = 4; total tumors = 8) were intravenously injected with liposomal doxorubicin. The right flank tumor was histoplasty-treated, and tumors were fluorescently imaged to detect doxorubicin uptake after histoplasty treatment. Next, 4T1 tumor-bearing mice were randomized into 2 treatment groups (sham vs histoplasty, n = 3 per group). Forty-eight hours after sham/histoplasty treatment, tumors were harvested and analyzed using flow cytometry. RESULTS: Histoplasty significantly increased (P = .002) liposomal doxorubicin diffusion into 4T1 tumors compared with untreated tumors (2.12- vs 1.66-fold increase over control). Flow cytometry on histoplasty-treated tumors (n = 3) demonstrated a significant increase in tumor macrophage frequency (42% of CD45 vs 33%; P = .022) and a significant decrease in myeloid-derived suppressive cell frequency (7.1% of CD45 vs 10.3%; P = .044). Histoplasty-treated tumors demonstrated increased CD8+ (5.1% of CD45 vs 3.1%; P = .117) and CD4+ (14.1% of CD45 vs 11.8%; P = .075) T-cell frequency. CONCLUSIONS: Histoplasty is a nonablative focused US approach to noninvasively modify the tumor ECM, increase chemotherapeutic uptake, and alter the tumor immune microenvironment.


Asunto(s)
Doxorrubicina , Ratones Endogámicos BALB C , Microambiente Tumoral , Animales , Doxorrubicina/farmacología , Doxorrubicina/administración & dosificación , Doxorrubicina/análogos & derivados , Femenino , Línea Celular Tumoral , Ratones , Antibióticos Antineoplásicos/farmacología , Antibióticos Antineoplásicos/administración & dosificación , Neoplasias Mamarias Experimentales/patología , Neoplasias Mamarias Experimentales/diagnóstico por imagen , Neoplasias Mamarias Experimentales/cirugía , Neoplasias Mamarias Experimentales/metabolismo , Neoplasias Mamarias Experimentales/tratamiento farmacológico , Neoplasias de la Mama/patología , Transductores , Matriz Extracelular/metabolismo , Matriz Extracelular/patología , Polietilenglicoles/química , Modelos Animales de Enfermedad , Antígenos Comunes de Leucocito
8.
Radiographics ; 44(10): e240029, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39298354

RESUMEN

High-frequency US provides excellent visualization of superficial structures and lesions, is a preferred diagnostic modality for anatomic characterization of neck abnormalities, and has a central role in clinical decision making. Recent technological advancements have led to the development of transducers that surpass 20 MHz, elevating high-frequency US to a highly valuable diagnostic tool with broader clinical use and enabling greater spatial resolution in the assessment of skin and superficial nerves and muscles. The authors focus on evolving applications of high-frequency US in neck imaging, emphasizing practical insights and strategies in skin and neuromuscular applications. ©RSNA, 2024 Supplemental material and the slide presentation from the RSNA Annual Meeting are available for this article.


Asunto(s)
Cuello , Piel , Transductores , Ultrasonografía , Humanos , Cuello/diagnóstico por imagen , Ultrasonografía/métodos , Piel/diagnóstico por imagen , Músculos del Cuello/diagnóstico por imagen
9.
Int J Hyperthermia ; 41(1): 2389288, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39134055

RESUMEN

The exponential growth of therapeutic ultrasound applications demonstrates the power of the technology to leverage the combinations of transducer technology and treatment monitoring techniques to effectively control the preferred bioeffect to elicit the desired clinical effect.Objective: This review provides an overview of the most commonly used bioeffects in therapeutic ultrasound and describes existing transducer technologies and monitoring techniques to ensure treatment safety and efficacy.Methods and materials: Literature reviews were conducted to identify key choices that essential in terms of transducer design, treatment parameters and procedure monitoring for therapeutic ultrasound applications. Effective combinations of these options are illustrated through descriptions of several clinical indications, including uterine fibroids, prostate disease, liver cancer, and brain cancer, that have been successful in leveraging therapeutic ultrasound to provide effective patient treatments.Results: Despite technological constraints, there are multiple ways to achieve a desired bioeffect with therapeutic ultrasound in a target tissue. Visualizations of the interplay of monitoring modality, bioeffect, and applied acoustic parameters are presented that demonstrate the interconnectedness of the field of therapeutic ultrasound. While the clinical indications explored in this review are at different points in the clinical evaluation path, based on the ever expanding research being conducted in preclinical realms, it is clear that additional clinical applications of therapeutic ultrasound that utilize a myriad of bioeffects will continue to grow and improve in the coming years.Conclusions: Therapeutic ultrasound will continue to improve in the next decades as the combination of transducer technology and treatment monitoring techniques will continue to evolve and be translated in clinical settings, leading to more personalized and efficient therapeutic ultrasound mediated therapies.


Asunto(s)
Transductores , Terapia por Ultrasonido , Humanos , Terapia por Ultrasonido/métodos
10.
Int J Hyperthermia ; 41(1): 2376681, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39111806

RESUMEN

OBJECTIVE: To demonstrate the feasibility of using a ring array ultrasound (US) transducer, guided by ultrasound tomography (UST), for generating and monitoring mild hyperthermia (MHTh). METHODS: In silico and in vitro experiments were designed to evaluate the efficacy of a ring array US transducer for generating MHTh and monitoring changes in temperature. In a series of in silico studies, we compared the acoustic focal profiles produced by a ring array US transducer transmitting at different frequencies and further investigated the effectiveness of UST-guidance in implementing aberration correction to enhance the focal profile. In vitro experiments evaluated the capability of using a ring array US transducer to generate and maintain MHTh and the accuracy of using UST to monitor temperature changes. RESULTS: The simulations demonstrated that a ring array US transducer achieves symmetrical and localized acoustic focusing. In a heterogenous tissue model, a ring array US transducer achieved a superior acoustic focus by implementing aberration correction with guidance from UST. In vitro experiments demonstrated the capability of a ring array US transducer to generate MHTh in a tissue-mimicking phantom in an average of 117 ± 18 s and subsequently maintain MHTh. Lastly, a ring array US transducer utilized UST to track temperature changes in a preheated water-filled inclusion while it passively cooled from 45 °C to 25 °C, with a maximum error of 0.58 °C. CONCLUSION: A ring array US transducer can noninvasively generate and monitor MHTh, overcoming many limitations of current clinical systems. The closed geometry of the transducer is optimal for acoustic focusing and UST-guidance allows for improved aberration correction in a heterogenous medium. Utilizing UST thermometry with the same ring array US transducer will allow for implementing an image-guided, temperature-controlled, all-acoustic MHTh system.


Asunto(s)
Hipertermia Inducida , Transductores , Hipertermia Inducida/métodos , Hipertermia Inducida/instrumentación , Humanos , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Fantasmas de Imagen
11.
Int J Hyperthermia ; 41(1): 2325477, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38439505

RESUMEN

OBJECTIVE: Monitoring sensitivity of sonography in focused ultrasound ablation surgery (FUAS) is limited (no hyperechoes in ∼50% of successful coagulation in uterine fibroids). A more accurate and sensitive approach is required. METHOD: The echo amplitudes of the focused ultrasound (FUS) transducer in a testing mode (short pulse duration and low power) were found to correlate with the ex vivo coagulation. To further evaluate its coagulation prediction capabilities, in vivo experiments were carried out. The liver, kidney, and leg muscles of three adult goats were treated using clinical FUAS settings, and the echo amplitude of the FUS transducer and grayscale in sonography before and after FUAS were collected. On day 7, animals were sacrificed humanely, and the treated tissues were dissected to expose the lesion. Echo amplitude changes and lesion areas were analyzed statistically, as were the coagulation prediction metrics. RESULTS: The echo amplitude changes of the FUS transducer correlate well with the lesion areas in the liver (R = 0.682). Its prediction in accuracy (94.4% vs. 50%), sensitivity (92.9% vs. 35.7%), and negative prediction (80% vs. 30.8%) is better than sonography, but similar in specificity (80% vs. 100%) and positive prediction (100% vs. 100%). In addition, the correlation between tissue depth and the lesion area is not good (|R| < 0.2). Prediction performances in kidney and leg muscles are similar. CONCLUSION: The FUS echo amplitudes are sensitive to the tissue properties and their changes after FUAS. They are sensitive and reliable in evaluating and predicting FUAS outcomes.


Asunto(s)
Terapia por Ultrasonido , Animales , Hígado/diagnóstico por imagen , Hígado/cirugía , Riñón/diagnóstico por imagen , Riñón/cirugía , Coagulación Sanguínea , Transductores
12.
Eur J Pediatr ; 183(8): 3589-3598, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38831135

RESUMEN

The quality of cranial ultrasound has improved over time, with advancing technology leading to higher resolution, faster image processing, digital display, and back-up. However, some brain lesions may remain difficult to characterize: since higher frequencies result in greater spatial resolution, the use of additional transducers may overcome some of these limitations. The very high-frequency transducers (18-5 MHz) are currently employed for small parts and lung ultrasound. Here we report the first case series comparing the very high-frequency probes (18-5 MHz) with standard micro-convex probes (8-5 MHz) for cranial ultrasound in preterm infants. In this case series, we compared cranial ultrasound images obtained with a micro-convex transducer (8-5 MHz) and those obtained with a very high-frequency (18-5 MHz) linear array transducer in 13 preterm infants ≤ 32 weeks gestation (9 with cerebral abnormalities and 4 with normal findings). Ultrasound examinations using the very high-frequency linear transducer and the standard medium-frequency micro-convex transducer were performed simultaneously. We also compared ultrasound findings with brain MRI images obtained at term corrected age. Ultrasound images obtained with the very high-frequency (18-5 MHz) transducer showed high quality and accuracy. Notably, despite their higher frequency and expected limited penetration capacity, brain size is small enough in preterm infants, so that brain structures are close to the transducer, allowing for complete evaluation.    Conclusion: We propose the routine use of very high-frequency linear probes as a complementary scanning modality for cranial ultrasound in preterm infants ≤ 32 weeks gestation. What is Known: • Brain lesions in preterm infants may remain insufficiently defined through conventional cranial ultrasound scan. • Higher frequency probes  offer better spatial resolution but have a narrower filed of exploration and limited penetration capacity. What is New: • Very high-frequency probes were compared with standard medium-frequency probes for cranial ultrasound in infants  ≤ 32 weeks' gestation. • Thanks to the smaller skull size of preterm infants, the new very high-frequency transducers allowed a complete and accurate evaluation.


Asunto(s)
Ecoencefalografía , Recien Nacido Prematuro , Transductores , Humanos , Recién Nacido , Femenino , Masculino , Ecoencefalografía/métodos , Edad Gestacional , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Enfermedades del Prematuro/diagnóstico por imagen
13.
Pediatr Radiol ; 54(5): 737-742, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38418631

RESUMEN

BACKGROUND: Ultrasound is the modality of choice for the diagnosis of hypertrophic pyloric stenosis (HPS). The evolution of high-frequency transducers in ultrasound has led to inconsistent ways of measuring the pylorus. OBJECTIVE: To standardize the measurements and evaluate the appearance of the normal and hypertrophied pylorus with high-frequency transducers. MATERIALS AND METHODS: We retrospectively analyzed abdominal ultrasounds of infants with suspected HPS from January 2019-December 2020. We classified the layers of the pylorus while assessing the stratified appearance. Two pediatric radiologists measured the muscle thickness of the pylorus independently by two methods for interrater agreement. Measurement (a) includes the muscularis propria and muscularis mucosa. Measurement (b) includes only the muscularis propria. We also evaluated the echogenicity of the muscularis propria. The interrater agreement, mean, range of the muscle thickness, and the diagnostic accuracy of the two sets of measurements were calculated. RESULTS: We included 300 infants (114 F:186 M), 59 with HPS and 241 normal cases. There was a strong agreement between the readers assessed in the first 100 cases, and ICC was 0.99 (95% CI, 0.98-0.99). Measurement (a), median thickness is 2.4 mm in normal cases and 4.8 mm in HPS. Measurement (b), median thickness is 1.4 mm in normal cases and 4.0 mm in HPS. Measurement (a) has an accuracy of 89.7% (95% CI, 85.7-92.8%) with 98.3% sensitivity and 87.6% specificity. Measurement (b) has an accuracy of 98.0% (95% CI, 95.7-99.3%) with 89.8% sensitivity and 100.0% specificity. The pylorus stratification is preserved in all normal cases and 31/59 (52.5%) cases of HPS. There was complete/partial loss of stratification in 28/59 (47.5%) cases of HPS. In all HPS cases, the muscularis propria was echogenic. CONCLUSION: Measuring the muscularis propria solely has a better diagnostic accuracy, decreasing the overlap of negative and positive cases. The loss of pyloric wall stratification and echogenic muscularis propria is only seen in HPS.


Asunto(s)
Estenosis Hipertrófica del Piloro , Píloro , Transductores , Ultrasonografía , Humanos , Estudios Retrospectivos , Masculino , Femenino , Ultrasonografía/métodos , Píloro/diagnóstico por imagen , Lactante , Estenosis Hipertrófica del Piloro/diagnóstico por imagen , Recién Nacido , Sensibilidad y Especificidad
14.
J Acoust Soc Am ; 156(2): 954-967, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39133632

RESUMEN

Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.


Asunto(s)
Hueso Cortical , Fantasmas de Imagen , Ultrasonografía , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/fisiología , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Análisis de Fourier , Ondas Ultrasónicas , Humanos , Transductores , Análisis Numérico Asistido por Computador , Simulación por Computador
15.
Int J Audiol ; 63(2): 127-135, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36633444

RESUMEN

OBJECTIVE: The aim of this study was to investigate whether consumer-grade mobile audio equipment can be reliably used as a platform for the notched-noise test, including when the test is conducted outside the laboratory. DESIGN: Two studies were conducted: Study 1 was a notched-noise masking experiment with three different setups: in a psychoacoustic test booth with a standard laboratory PC; in a psychoacoustic test booth with a mobile device; and in a quiet office room with a mobile device. Study 2 employed the same task as Study 1, but compared circumaural headphones to insert earphones. STUDY SAMPLE: Nine and ten young, normal-hearing participants completed studies 1 and 2, respectively. RESULTS: The test-retest accuracy of the notched-noise test on the mobile implementation did not differ from that for the laboratory setup. A possible effect of the earphone design was identified in Study 1, which was corroborated by Study 2, where test-retest variability was smallest when comparing results from experiments conducted using identical acoustic transducers. CONCLUSIONS: Results and test-retest repeatability comparable to standard laboratory settings for the notched-noise test can be obtained with mobile equipment outside the laboratory.


Asunto(s)
Acústica , Ruido , Humanos , Ruido/efectos adversos , Psicoacústica , Computadoras de Mano , Transductores
16.
Ultrason Imaging ; 46(6): 312-319, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39189365

RESUMEN

Sm-doped Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 (PMN-0.28PT) ceramic has been reported to exhibit very large piezoelectric response (d33~1300 pC/N) that can be comparable with PMN-0.30PT single crystal. Based on the Sm-doped PMN-0.28PT ceramics, a high frequency ultrasound transducer with the center frequency above 30 MHz has been designed and fabricated for intravascular ultrasound imaging, and the performance of the transducer was investigated via ultrasound pulse-echo tests. Further, for a porcine vessel wall, the 2D and 3D ultrasound images were constructed using signal acquisition and processing from the fabricated high-frequency transducer. The obtained details of the vessel wall by the IVUS transducer indicate that Sm-doped PMN-0.28PT ceramic is a promising candidate for high frequency transducers.


Asunto(s)
Cerámica , Diseño de Equipo , Plomo , Transductores , Ultrasonografía Intervencional , Porcinos , Animales , Ultrasonografía Intervencional/métodos , Titanio , Imagenología Tridimensional/métodos
17.
Ultrason Imaging ; 46(3): 139-150, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38334055

RESUMEN

Two-dimensional ultrasound transducers enable the acquisition of fully volumetric data that have been demonstrated to provide greater diagnostic information in the clinical setting and are a critical tool for emerging ultrasound methods, such as super-resolution and functional imaging. This technology, however, is not without its limitations. Due to increased fabrication complexity, some matrix probes with disjoint piezoelectric panels may require initial calibration. In this manuscript, two methods for calibrating the element positions of the Vermon 1024-channel 8 MHz matrix transducer are detailed. This calibration is a necessary step for acquiring high resolution B-mode images while minimizing transducer-based image degradation. This calibration is also necessary for eliminating vessel-doubling artifacts in super-resolution images and increasing the overall signal-to-noise ratio (SNR) of the image. Here, we show that the shape of the point spread function (PSF) can be significantly improved and PSF-doubling artifacts can be reduced by up to 10 dB via this simple calibration procedure.


Asunto(s)
Artefactos , Diseño de Equipo , Relación Señal-Ruido , Transductores , Ultrasonografía , Calibración , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Fantasmas de Imagen
18.
Ultrason Imaging ; 46(3): 186-196, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38647142

RESUMEN

Conventional B-mode ultrasound imaging has difficulty in delineating homogeneous soft tissues with similar acoustic impedances, as the reflectivity depends on the acoustic impedance at the interface. As a quantitative imaging biomarker sensitive to alteration of biomechanical properties, speed-of-sound (SoS) holds promising potential for tissue and disease differentiation such as delineation of different breast tissue types with similar acoustic impedance. Compared to two-dimensional (2D) SoS images, three-dimensional (3D) volumetric SoS images achieved through a full-angle ultrasound scan can reveal more intricate morphological structures of tissues; however, they generally require a ring transducer. In this study, we introduce a 3D SoS reconstruction system that utilizes hand-held linear arrays instead. This system employs a passive reflector positioned opposite the linear arrays, serving as an echogenic reference for time-of-flight (ToF) measurements, and a high-definition camera to track the location corresponding to each group of transmit-receive data. To merge these two streams of ToF measurements and location tracking, a voxel-based reconstruction algorithm is implemented. Experimental results with gelatin phantom and ex vivo tissue have demonstrated the stability of our proposed method. Moreover, the results underscore the potential of this system as a complementary diagnostic modality, particularly in the context of diseases such as breast cancer.


Asunto(s)
Imagenología Tridimensional , Fantasmas de Imagen , Ultrasonografía , Ultrasonografía/métodos , Imagenología Tridimensional/métodos , Animales , Algoritmos , Transductores , Diseño de Equipo , Humanos , Femenino
19.
Clin Oral Investig ; 28(5): 294, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698252

RESUMEN

OBJECTIVES: To compare ultrasonic scaler prototypes based on a planar piezoelectric transducer with different working frequencies featuring a titanium (Ti-20, Ti-28, and Ti-40) or stainless steel (SS-28) instrument, with a commercially available scaler (com-29) in terms of biofilm removal and reformation, dentine surface roughness and adhesion of periodontal fibroblasts. MATERIALS AND METHODS: A periodontal multi-species biofilm was formed on specimens with dentine slices. Thereafter specimens were instrumented with scalers in a periodontal pocket model or left untreated (control). The remaining biofilms were quantified and allowed to reform on instrumented dentine slices. In addition, fibroblasts were seeded for attachment evaluation after 72 h of incubation. Dentine surface roughness was analyzed before and after instrumentation. RESULTS: All tested instruments reduced the colony-forming unit (cfu) counts by about 3 to 4 log10 and the biofilm quantity (each p < 0.01 vs. control), but with no statistically significant difference between the instrumented groups. After 24-hour biofilm reformation, no differences in cfu counts were observed between any groups, but the biofilm quantity was about 50% in all instrumented groups compared to the control. The attachment of fibroblasts on instrumented dentine was significantly higher than on untreated dentine (p < 0.05), with the exception of Ti-20. The dentine surface roughness was not affected by any instrumentation. CONCLUSIONS: The planar piezoelectric scaler prototypes are able to efficiently remove biofilm without dentine surface alterations, regardless of the operating frequency or instrument material. CLINICAL RELEVANCE: Ultrasonic scalers based on a planar piezoelectric transducer might be an alternative to currently available ultrasonic scalers.


Asunto(s)
Biopelículas , Raspado Dental , Dentina , Fibroblastos , Ligamento Periodontal , Propiedades de Superficie , Titanio , Humanos , Raspado Dental/instrumentación , Técnicas In Vitro , Dentina/microbiología , Ligamento Periodontal/citología , Transductores , Adhesión Celular , Acero Inoxidable , Diseño de Equipo , Terapia por Ultrasonido/instrumentación
20.
Sensors (Basel) ; 24(11)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38894228

RESUMEN

Piezoelectric effects were first discovered more than a hundred years ago and, since then, have been widely used across various fields [...].


Asunto(s)
Transductores , Humanos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda