Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 18.026
Filtrar
Más filtros

Publication year range
1.
Pediatr Nephrol ; 39(5): 1447-1457, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38041747

RESUMEN

BACKGROUND: Split kidney function (SKF) is critical for treatment decision in pediatric patients with hydronephrosis and is commonly measured using renal scintigraphy (RS). Non-contrast-enhanced magnetic resonance urography (NCE-MRU) is increasingly used in clinical practice. This study aimed to investigate the feasibility of using NCE-MRU as an alternative to estimate SKF in pediatric patients with hydronephrosis, compared to RS. METHODS: Seventy-five pediatric patients with hydronephrosis were included in this retrospective study. All patients underwent NCE-MRU and RS within 2 weeks. Kidney parenchyma volume (KPV) and texture analysis parameters were obtained from T2-weighted (T2WI) in NCE-MRU. The calculated split KPV (SKPV) percent and texture analysis parameters percent of left kidney were compared with the RS-determined SKF. RESULTS: SKPV showed a significant positive correlation with SKF (r = 0.88, p < 0.001), while inhomogeneity was negatively correlated with SKF (r = - 0.68, p < 0.001). The uncorrected and corrected prediction models of SKF were established using simple and multiple linear regression. Bland-Altman plots demonstrated good agreement of both predictive models. The residual sum of squares of the corrected prediction model was lower than that of the uncorrected model (0.283 vs. 0.314) but not statistically significant (p = 0.662). Subgroup analysis based on different MR machines showed correlation coefficients of 0.85, 0.95, and 0.94 between SKF and SKPV for three different scanners, respectively (p < 0.05 for all). CONCLUSIONS: NCE-MRU can be used as an alternative method for estimating SKF in pediatric patients with hydronephrosis when comparing with RS. Specifically, SKPV proves to be a simple and universally applicable indicator for predicting SKF.


Asunto(s)
Hidronefrosis , Urografía , Niño , Humanos , Estudios Retrospectivos , Urografía/métodos , Hidronefrosis/diagnóstico por imagen , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cintigrafía , Espectroscopía de Resonancia Magnética
2.
BMC Urol ; 24(1): 73, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532363

RESUMEN

PURPOSE: To investigate the value of CT urography (CTU) indicators in the quantitative differential diagnosis of bladder urothelial carcinoma (BUC) and inverted papilloma of the bladder (IPB). MATERIAL AND METHODS: The clinical and preoperative CTU imaging data of continuous 103 patients with histologically confirmed BUC or IPB were retrospectively analyzed. The imaging data included 6 qualitative indicators and 7 quantitative measures. The recorded clinical information and imaging features were subjected to univariate and multivariate logistic regression analysis to find independent risk factors for BUC, and a combined multi-indicator prediction model was constructed, and the prediction model was visualized using nomogram. ROC curve analysis was used to calculate and compare the predictive efficacy of independent risk factors and nomogram. RESULTS: Junction smoothness, maximum longitudinal diameter, tumor-wall interface and arterial reinforcement rate were independent risk factors for distinguishing BUC from IPB. The AUC of the combined model was 0.934 (sensitivity = 0.808, specificity = 0.920, accuracy = 0.835), and its diagnostic efficiency was higher than that of junction smoothness (AUC=0.667, sensitivity = 0.654, specificity = 0.680, accuracy = 0.660), maximum longitudinal diameter (AUC=0.757, sensitivity = 0.833, specificity = 0.604, accuracy = 0.786), tumor-wall interface (AUC=0.888, sensitivity = 0.755, specificity = 0.808, accuracy = 0.816) and Arterial reinforcement rate (AUC=0.786, sensitivity = 0.936, specificity = 0.640, accuracy = 0.864). CONCLUSION: Above qualitative and quantitative indicators based on CTU and the combination of them may be helpful to the differential diagnosis of BUC and IPB, thus better assisting in clinical decision-making. KEY POINTS: 1. Bladder urothelial carcinoma (BUC) and inverted papilloma of the bladder (IPB) exhibit similar clinical symptoms and imaging presentations. 2. The diagnostic value of CT urography (CTU) in distinguishing between BUC and IPB has not been documented. 3. BUC and IPB differ in lesion size, growth pattern and blood supply. 4. The diagnostic efficiency is optimized by integrating multiple independent risk factors into the prediction model.


Asunto(s)
Carcinoma de Células Transicionales , Papiloma Invertido , Neoplasias de la Vejiga Urinaria , Humanos , Neoplasias de la Vejiga Urinaria/cirugía , Carcinoma de Células Transicionales/patología , Vejiga Urinaria/patología , Papiloma Invertido/patología , Estudios Retrospectivos , Urografía/métodos , Tomografía Computarizada por Rayos X
3.
BMC Pediatr ; 24(1): 213, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38528521

RESUMEN

BACKGROUND: Urinary system anomalies, both congenital and acquired, constitute a relatively common clinical problem in children. The main role of diagnostic imaging is to determine early diagnosis and support therapeutic decisions to prevent the development of chronic renal disease. The aim of this study was to evaluate the utility of magnetic resonance urography (MRU) in assessment of urinary system in children, by comparing differential renal function calculated using MRU with dynamic renal scintigraphy (DRS). MATERIALS AND METHODS: The study group consisted of 46 patients aged 1 week to 17 years (median 7 (0.5; 13) years, 17 (37%) girls, 29 (63%) boys), who underwent dynamic renal scintigraphy due to various clinical reasons. All participants underwent MRU, which was used to measure differential renal function. Functional analysis was performed using dedicated external software (CHOP-fMRU and pMRI without prior knowledge of DRS results. MRU results acquired using pMRI were assessed for inter and intraobserver agreement. RESULTS: Statistical analysis of the results showed excellent agreement between MRU and DRS in measuring differential renal function with Pearson correlation coefficient 0.987 for CHOP-fMRU and 0.971 for pMRI, p < 0.001. Interclass correlation coefficient (ICC) for these programs was 0.987 (95% CI 0.976-0.993) and 0.969 (95% CI 0.945-0.983) respectively, p < 0.001. The Bland-Altman 95% limits of agreement for CHOP-fMRU results vs. DRS was - 6.29-5.50 p.p. and for pMRI results vs. DRS - 9.15-9.63 p.p. The differential renal function measurements calculated in pMRI showed excellent intraobserver and interobserver agreement with ICC 0.996 (95% CI 0.994-0.998) and 0.992 (95% CI 0.986-0.996) respectively, p < 0.001. CONCLUSIONS: The study showed no significant differences between magnetic resonance urography and dynamic renal scintigraphy in calculating differential renal function. It indicates high utility of MRU in the evaluation of urinary system in children.


Asunto(s)
Riñón , Urografía , Niño , Masculino , Femenino , Humanos , Urografía/métodos , Riñón/diagnóstico por imagen , Pruebas de Función Renal , Cintigrafía , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética
4.
Radiology ; 309(3): e230567, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38085083

RESUMEN

Background Estimating glomerular filtration rate (GFR) from serum creatinine can be inaccurate, and current procedures for measuring GFR are time-consuming and cumbersome. Purpose To develop a method for measuring GFR based on iomeprol clearance assessed at CT urography in kidney donor candidates and compare this with iohexol clearance (reference standard for measuring GFR). Materials and Methods This cross-sectional retrospective study included data from kidney donor candidates who underwent both iohexol clearance and CT urography between July 2016 and October 2022. CT-measured GFR was calculated as the iomeprol excretion rate in the urinary system between arterial and excretory phases (Hounsfield units times milliliters per minute) divided by a surrogate for serum iomeprol concentration in the aorta at the midpoint (in Hounsfield units). Performance of CT-measured GFR was assessed with use of mean bias (mean difference between CT-measured GFR and iohexol clearance), precision (the distance between quartile 1 and quartile 3 of the bias [quartile 3 minus quartile 1], with a small value indicating high precision), and accuracy (percentage of CT-measured GFR values falling within 10%, 20%, and 30% of iohexol clearance values). Intraobserver agreement was assessed for 30 randomly selected individuals with the Lin concordance correlation coefficient. Results A total of 75 kidney donor candidates were included (mean age, 51 years ± 13 [SD]; 45 female). The CT-measured GFR was unbiased (1.1 mL/min/1.73 m2 [95% CI: -1.9, 4.1]) and highly precise (16.2 mL/min/1.73 m2 [quartiles 1 to 3, -6.6 to 9.6]). The accuracy of CT-measured GFR within 10%, 20%, and 30% was 61.3% (95% CI: 50.3, 72.4), 88.0% (95% CI: 80.7, 95.4), and 100%, respectively. Concordance between CT-based GFR measurements taken 2 months apart was almost perfect (correlation coefficient, 0.99 [95% CI: 0.98, 0.99]). Conclusion In living kidney donors, GFR measured based on iomeprol clearance assessed at CT urography showed good agreement with GFR measured based on iohexol clearance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Davenport in this issue.


Asunto(s)
Trasplante de Riñón , Humanos , Femenino , Persona de Mediana Edad , Tasa de Filtración Glomerular , Yohexol , Estudios Retrospectivos , Estudios Transversales , Urografía , Creatinina , Tomografía Computarizada por Rayos X/métodos , Riñón/diagnóstico por imagen
5.
Magn Reson Med ; 89(1): 343-355, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36089805

RESUMEN

PURPOSE: To assess the potential of DCE MR CEST urography for assessing renal function in mice with unilateral ureter obstruction (UUO) by simultaneous pH and renal uptake/clearance measurements following injection of iopamidol. METHODS: The right ureter of nine mice was obstructed via suture ligation. The animals were imaged at day 1, 2, and 3 post-obstruction on an 11.7T MRI scanner. Ninety-six sets of saturated CEST images at 4.3 and 5.5 ppm were collected. Renal pH values were obtained by calculating the signal ratio for these two frequencies and using a pH calibration curve. Renal time activity curves were measured as a percentage change in the post-injection CEST signal at 4.3 ppm relative to the average pre-injection signal. RESULTS: For the healthy mice, the time activity curves of both kidneys were nearly identical and displayed rapid excretion of contrast. For the UUO mice, the dynamic CEST curves for the obstructed kidneys displayed prolonged time to peak (TTP) values and delayed contrast excretion compared with the contralateral (CL) kidneys. Renal pH maps of the healthy animals showed similar acidic values for both kidneys (pH 6.65 ± 0.04 vs 6.67 ± 0.02), whereas in the obstructed kidneys there was a significant increase in pH values compared with the CL kidneys (pH 6.67 ± 0.08 vs 6.79 ± 0.11 in CL and UUO kidneys, respectively). CONCLUSION: Our findings indicate that DCE-MR-CEST urography can detect changes in renal uptake/excretion and pH homeostasis and distinguish between obstructed and unobstructed kidney as early as 1 day after UUO.


Asunto(s)
Uréter , Obstrucción Ureteral , Animales , Ratones , Obstrucción Ureteral/diagnóstico por imagen , Riñón/diagnóstico por imagen , Riñón/fisiología , Imagen por Resonancia Magnética/métodos , Concentración de Iones de Hidrógeno , Urografía
6.
J Urol ; 209(6): 1099-1106, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36883858

RESUMEN

PURPOSE: Microhematuria is a highly prevalent condition with a low associated risk of urothelial and upper tract malignancy. The AUA Guidelines recently changed recommendations for imaging favoring renal ultrasound for low- and intermediate-risk patients with microhematuria. We summarize the diagnostic test characteristics of computed tomography urography, renal ultrasound, and magnetic resonance urography in comparison with surgical pathology for the diagnosis of upper urinary tract cancer in microhematuria and gross hematuria patients. MATERIALS AND METHODS: This study is a systematic review and meta-analysis using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines from evidence collected for the 2020 AUA Microhematuria Guidelines report, including studies assessing imaging following diagnosis of hematuria published from January 2010 through December 2019. RESULTS: The search identified 20 studies which reported the prevalence of malignant and benign diagnoses in relation to imaging modality, of which 6 were included in the quantitative analysis. For the detection of renal cell carcinoma and upper urinary tract carcinoma in patients with microhematuria and gross hematuria, computed tomography urography had a sensitivity of 94% (95% CI, 84%-98%) and a specificity of 99% (95%CI, 97%-100%) with a certainty of evidence rating of very low and low, respectively when 4 studies were pooled. In comparison, ultrasound demonstrated a sensitivity ranging from 14%-96% (low certainty of evidence) and a specificity of 99%-100% in 2 studies (moderate certainty of evidence), while magnetic resonance urography demonstrated a sensitivity of 83% and specificity of 86% in 1 study with a low certainty of evidence. CONCLUSIONS: In a limited data set for each individual imaging modality, computed tomography urography appears the most sensitive imaging modality for the diagnostic evaluation of microhematuria. Future studies will be needed to evaluate the clinical and health system financial impacts of the change in guideline recommendations from computed tomography urography to renal ultrasound in evaluating low- and intermediate-risk patients with microhematuria.


Asunto(s)
Neoplasias Renales , Neoplasias Urológicas , Humanos , Tomografía Computarizada por Rayos X/métodos , Hematuria/diagnóstico por imagen , Hematuria/etiología , Neoplasias Urológicas/diagnóstico , Neoplasias Urológicas/diagnóstico por imagen , Ultrasonografía , Urografía/métodos
7.
Acta Radiol ; 64(6): 2190-2197, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37032426

RESUMEN

BACKGROUND: Many ovarian cancer (OC) residual-disease prediction models were not externally validated after being constructed, the clinical applicability needs to be evaluated. PURPOSE: To compare computed tomography urography (CTU) with PET/CT in validating models for predicting residual disease in OC. MATERIAL AND METHODS: A total of 250 patients were included during 2018-2021. The CTU and PET/CT scans were analyzed, generating CT-Suidan, PET-Suidan, CT-Peking Union Medical College Hospital (PUMC), and PET-PUMC models. All imagings were evaluated by two readers independently, then compared to pathology. According to surgical outcomes, all patients were divided into the R0 group, with no visible residual disease, and the R1 group, with any visible residual disease. Logistic regression was used to assess the discrimination and calibration abilities of each model. RESULTS: CTU and PET/CT showed good diagnostic performance in predicting OC peritoneal metastases based on the Suidan and PUMC model (all the accuracies >0.8). As for model evaluation, the value of correct classification of the CT-Suidan, PET-Suidan, CT-PUMC, and PET-PUMC models was 0.89, 0.84, 0.88, and 0.83, respectively, representing stable calibration. The areas under the curve (AUC) of these models were 0.95, 0.90, 0.91, and 0.90, respectively. Furthermore, the accuracy of these models at the optimal threshold value (score 3) was 0.75, 0.78, 0.80, and 0.80, respectively. All two-paired comparisons of the AUCs and accuracies did not show a significant difference (all P > 0.05). CONCLUSION: CT-Suidan, CT-PUMC, PET-Suidan, and PET-PUMC models had equal abilities in predicting the residual disease of OC. The CT-PUMC model was recommended for its economic and user-friendly characteristics.


Asunto(s)
Neoplasias Ováricas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Urografía , Neoplasias Ováricas/diagnóstico por imagen , Neoplasias Ováricas/patología , Fluorodesoxiglucosa F18
8.
Pediatr Radiol ; 53(7): 1391-1404, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36149476

RESUMEN

Magnetic resonance urography (MRU) is an important MRI application that provides noninvasive comprehensive morphological and functional evaluation of the kidneys and urinary tract. It can be used to assess congenital anomalies of the kidney and urinary tract, which often present as urinary tract dilation. In children, MRU allows for high tissue contrast and high spatial resolution without requiring ionizing radiation. Magnetic resonance urography requires patient preparation in the form of pre-examination intravenous hydration, placement of a urinary catheter, and the administration of diuretics at the time of the exam. The imaging protocol is based on T2-weighted images for anatomical assessment and dynamic post-contrast images for functional evaluation. These images are then used to generate quantitative and graphic results including contrast transit and excretion time as well as to calculate differential renal function. This review focuses on a simple approach to pediatric MRU acquisition and interpretation based on clinical cases and the authors' experience.


Asunto(s)
Sistema Urinario , Urografía , Niño , Humanos , Urografía/métodos , Sistema Urinario/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Riñón , Espectroscopía de Resonancia Magnética
9.
Pediatr Radiol ; 53(5): 1033-1038, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36688972

RESUMEN

Bladder duplication is an extremely rare congenital anomaly of the urinary system that is more frequent in boys; the literature is limited to case reports and case series. We describe two cases of bladder duplication in two infant girls with an uncommon variant of complete sagittal septum not included in the Abrahamson classification. The diagnosis was made using magnetic resonance urography, combining excellent anatomical information and static and dynamic evaluation of the urinary tract. The diagnostic information provided by MR-urography was confirmed on surgical exploration. These cases provide an opportunity for paediatric radiologists and urologists to learn more about bladder duplication and improve their diagnosis of this rare condition.


Asunto(s)
Sistema Urinario , Anomalías Urogenitales , Masculino , Niño , Femenino , Humanos , Lactante , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/cirugía , Vejiga Urinaria/anomalías , Imagen por Resonancia Magnética , Urografía
10.
Pediatr Surg Int ; 40(1): 10, 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38006461

RESUMEN

BACKGROUND: To determine the utility of contrast-enhanced voiding urography (CeVUS) in the treatment of vesicoureteral reflux (VUR) through ureterovesical reimplantation in children. METHODS: A total of 159 children with recurrent urinary tract infections were selected for CeVUS and voiding cystourethrography (VCUG) from December 2018 to December 2020, among whom 78 patients were eventually diagnosed with VUR. Overall, 60 pyelo-ureteric units (PUUs) were operated according to surgical indications. Accordingly, we determined the general clinical characteristics of all children, obtained two-dimensional ultrasound images, assessed the reflux status of children using the contrast-enhanced technique, and compared the obtained results via CeVUS and VCUG. Both imaging modalities were reperformed at 6, 12, and 18 months after surgery to evaluate postoperative outcomes. In particular, we assessed the consistency of the evaluation and calculated the diagnostic efficacy of CeVUS for different levels of reflux at different time points. RESULTS: CeVUS showed considerable efficacy in the diagnosis of children with VUR. Notably, the diagnostic results of both CeVUS and VCUG achieved high agreement, with a kappa value of 0.966 (P < 0.001). The results of our follow-up at different stages and evaluation of postoperative efficacy revealed that CeVUS possessed substantial diagnostic efficacy and good consistency with VCUG. CONCLUSION: CeVUS is an accurate and safe examination, with considerable clinical significance for diagnosing VUR in children, determining the treatment approach, conducting follow-up during treatment, and evaluating subsequent treatment outcomes.


Asunto(s)
Uréter , Reflujo Vesicoureteral , Niño , Humanos , Lactante , Reflujo Vesicoureteral/diagnóstico por imagen , Reflujo Vesicoureteral/cirugía , Medios de Contraste , Ultrasonografía/métodos , Urografía/métodos , Micción
11.
Radiol Med ; 128(5): 601-611, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37027091

RESUMEN

CT urography is a single term used to refer to different scanning protocols that can be applied for a number of clinical indications. If, on the one hand, this highlights the role of the radiologist in deciding the most suitable technique to perform according to the patient's needs, on the other hand, a certain confusion may arise due to the different technical and clinical variables that have to be taken into account. This has been well demonstrated by a previous work based on an online questionnaire administered to a population of Italian radiologists that brought out similarities as well as differences across the national country. Defining precise guidelines for each clinical scenario, although desirable, is a difficult task to accomplish, if not even unfeasible. According to the prementioned survey, five relevant topics concerning CT urography have been identified: definition and clinical indications, opacification of the excretory system, techniques, post-processing reconstructions, and radiation dose and utility of dual-energy CT. The aim of this work is to deepen and share knowledge about these main points in order to assist the radiology in the daily practice. Moreover, a synopsis of recommendations agreed by the Italian board of genitourinary imaging is provided.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos
12.
Turk J Med Sci ; 53(1): 264-272, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36945947

RESUMEN

BACKGROUND: Dual-energy computed tomography scans can provide significant benefits to the urinary system. The aim of this study is to determine the limitations and benefits of using dual energy CT urography in patients with urinary system stones and cysts. METHODS: In the analysis of the images, the virtual noncontrasted images obtained from the combined nephrogenicexcretory phase and the true noncontrasted images were evaluated. The true noncontrast images were accepted as the gold standard for stone detection. RESULTS: Eighty-three different stones were detected in 26 of the 115 patients included in the study. Sensibilities of virtual noncontrast images in detecting urinary system stones were 66.7% and 65.4% according to the first and second radiologists, respectively. In this study, 32 hyperdense cysts were detected. According to iodine map images, there was no enhancement in 26 of 32 cysts; only 5 cysts showed minimal contrast enhancement. One patient could not decide on contrast enhancement. DISCUSSION: As a result, if CT urography is performed with dual energy, it can provide additional information in patients with urinary system disorder.


Asunto(s)
Cálculos Urinarios , Enfermedades Urológicas , Humanos , Medios de Contraste , Cálculos Urinarios/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos
13.
Eur Radiol ; 32(12): 8588-8596, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35763094

RESUMEN

OBJECTIVE: To determine the sensitivity of dual-energy (DE) virtual non-contrast computed tomography (vNCT), generated from the excretory phase of a CT urogram, compared to true non-contrast CT (tNCT) for the detection of urinary calculi. METHODS: A search of multiple medical literature databases was performed using predetermined search terms. Inclusion and exclusion criteria were applied, and bias risk was assessed by two independent reviewers using the quality assessment of diagnostic accuracy studies (QUADAS) tool. Collated estimates of sensitivity were generated, and sources of heterogeneity were identified and reviewed. RESULTS: Thirteen studies (1760 patients; 1740 urinary calculi) were included for sensitivity assessment. Pooled sensitivity for urinary calculi on vNCT was 78.1% (95% CI: 70.2 to 85.0%); however, heterogeneity between studies was very high (I2 = 92.0%). Sources of heterogeneity between studies were explored through subgroup analysis by categorising studies according to slice thickness (≥ 2 mm and < 2 mm), use of oral hydration, and use of intravenous furosemide. Pooled sensitivity for detection of urinary calculi on vNCT for studies that used oral hydration and < 2 mm slice thickness was 92.2% (95% CI: 89.5 to 94.5%). Pooled specificity was not performed as true negatives were not reported in most studies. Potential sources of bias were identified in included studies. CONCLUSION: vNCT demonstrated a moderate pooled sensitivity compared to tNCT for the detection of urinary calculi in split bolus CT urogram protocols. However, subgroup analysis suggests higher sensitivity when employing oral hydration and < 2 mm slice thickness or increment. KEY POINTS: • vNCT demonstrated moderate pooled sensitivity for the detection of urinary calculi in split bolus CT urogram protocols. • Subgroup analysis suggested higher sensitivity with oral hydration and < 2 mm slice thickness or increment.


Asunto(s)
Cálculos Urinarios , Urografía , Humanos , Urografía/métodos , Cálculos Urinarios/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Furosemida , Sensibilidad y Especificidad
14.
Q J Nucl Med Mol Imaging ; 66(3): 280-289, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31992688

RESUMEN

BACKGROUND: Accuracy of [68Ga]PSMA-11 PET/CT may be hampered by ureter accumulation, mimicking lymph node metastases depending on localization and configuration. The benefit of CT urography for differentiation of lymph node metastasis from urinary tract activity was evaluated in a "PET/CT with low-dose CT" setting. METHODS: Retrospective analysis of PET/CT for primary staging, biochemical recurrence or local treatment planning in patients with prostate cancer. For CT urography (CTU), iodinated contrast agent was administered 10 minutes prior to image acquisition. All potential pathologic (peri)ureteral tracer uptake was assigned to excretory ureteral accumulation or pathological lesion. To assess additional provided benefit of CTU all foci were rated with an introduced scoring system (ranging from 0 pts: CTU not needed; up to 3 pts: no differentiation possible without CTU). Success of ureter contrasting was assessed by measurement of Hounsfield units. Besides benefit for reading urography-enhanced PET/CT, the possible impact on subsequent patient treatment was evaluated. RESULTS: A number of N.=247 patients were included in this study. By CT urography, it was possible to identify each ureter on low-dose CT, with its major part contrasted. In 120/247 (48.6%) patients, urography increased the diagnostic confidence while providing substantial support for interpretation in 60 (24.3%) cases. In 42 (17.0%) patients, urography was clinically relevant (up-/downstaging) with potential impact on subsequent patient care. In 30 of these 42 cases (12.1% of all), discrepant treatment would have resulted from a misdiagnosed tracer accumulation without urography. CONCLUSIONS: CT urography benefits the interpretation of [68Ga]-PSMA-11 PET/CT with low-dose CT and leads to discrepant patient treatment in a small but significant subset of patients (12% in our cohort). The implementation of CT urography into standard protocols of [68Ga]PSMA-11 PET/CT with low-dose CT is recommended.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Radioisótopos de Galio , Humanos , Metástasis Linfática , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Urografía
15.
BMC Urol ; 22(1): 60, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413901

RESUMEN

BACKGROUND: To evaluate the diagnostic accuracy of computed tomography-urography (CTU) to rule out urinary bladder cancer (UBC) and whether patients thereby could omit cystoscopy. METHODS: All patients evaluated for macroscopic hematuria with CTU with cortico-medullary phase (CMP) and cystoscopy at our institute between 1st November 2016 and 31st December 2019 were included. From this study cohort a study group consisting of all UBC patients and a control group of 113 patients randomly selected from all patients in the study cohort without UBC. Two radiologists blinded to all clinical data reviewed the CTUs independently. CTUs were categorized as positive, negative or indeterminate. Diagnostic accuracy and proportion of potential omittable cystoscopies were calculated for the study cohort by generalizing the results from the study group. RESULTS: The study cohort consisted of 2195 patients, 297 of which were in the study group (UBC group, n = 207 and control group, n = 90). Inter-rater reliability was high (κ 0.84). Evaluation of CTUs showed that 174 patients were assesessed as positive (showing UBC), 46 patients as indeterminate (not showing UBC but with limited quality of CTU), and 77 patients as negative (not showing UBC with good quality of CTU). False negative rate was 0.07 (95%, CI 0.04-0.12), false positive rate was 0.01 (95% CI 0.0-0.07) and negative predictive value was 0.99 (95% CI 0.92-1.0). The area under the curve was 0.93 (95% CI 0.90-0.96). Only 2.9% (3/102) with high-risk tumors and 11% (12/105) with low- or intermediate-risk tumors had a false negative CTU. Cystoscopy could potentially have been omitted in 57% (1260/2195) of all evaluations. CONCLUSIONS: CTU with CMP can exclude UBC with high accuracy. In case of negative CTU, it might be reasonable to omit cystoscopy, but future confirmative studies with possibly refined technique are needed.


Asunto(s)
Neoplasias de la Vejiga Urinaria , Humanos , Cistoscopía/métodos , Hematuria/diagnóstico , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Vejiga Urinaria/patología , Urografía/métodos
16.
BMC Urol ; 22(1): 97, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35787264

RESUMEN

BACKGROUND: To assess the inter-observer and intra-observer reliability of the magnetic resonance urography (MRU)-upper urinary tract dilation (UUTD) grading system. METHODS: A total of 40 patients with a diagnosis of NB were enrolled in this study. The images were assembled in an electronic presentation randomly. The presentations were reviewed and graded by 4 junior and 4 senior urologists. One week later, the images were randomized again and reassessed. The inter-observer reliability was estimated by Kendall's coefficient of concordance and intra-class correlation coefficient (ICC), and the intra-observer reliability was estimated by weighted Cohen's kappa. RESULTS: The inter-observer reliability strength was excellent for all urologists, with the ICC value of 0.939 (0.908-0.963) and Kendall's W value of 0.967. The highest agreement was shown in Grade 4 at 92.50%, and the lowest in Grade 2 at 82.14%. All disagreements were within one grade of difference. Moreover, the Intra-observer reliability was excellent, with the weighted kappa value ranging from 0.904 to 0.954. CONCLUSIONS: The inter-observer and intra-observer reliability of this novel MRU-UUTD grading system is confirmed, providing adequate evidence for broader clinical application.


Asunto(s)
Vejiga Urinaria Neurogénica , Sistema Urinario , Dilatación , Humanos , Espectroscopía de Resonancia Magnética , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Vejiga Urinaria Neurogénica/diagnóstico por imagen , Sistema Urinario/diagnóstico por imagen , Urografía/métodos
17.
Pediatr Radiol ; 52(5): 985-997, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34839376

RESUMEN

Congenital abnormalities of the kidney and urinary tract include a wide range of malformations ranging from asymptomatic to life-threatening conditions. Although pediatric urogenital system imaging is based on the use of US (pre- and postnatal), voiding cystourethrography and scintigraphic study, magnetic resonance (MR) urography plays a fundamental role in the classification and management of congenital abnormalities of the kidney and urinary tract, giving an overview of the different clinical pictures, thanks to its panoramicity and high anatomical detail. In fact the anomalies of the urinary tract are phenotypically variable because they can affect simultaneously several segments of different embryonic derivation, with complex clinical pictures; they can appear both as isolated phenotypes or as complex malformative conditions, involving renal parenchyma, collecting system and bladder. A deep knowledge of this complex embryogenesis and its possible phenotypic patterns allows a correct interpretation of MR urography images. We describe the embryology and pathophysiology of congenital abnormalities of the kidney and urinary tract as well as MR urography technique and findings. Congenital abnormalities of the kidney and urinary tract are classified into four groups: (1) obstruction (proximal, middle and distal), (2) budding with respect to the Wolffian duct (site and number of ureter), (3) ascent and rotation (ectopia, malrotation and fusion of kidney) and (4) anomaly of metanephric differentiation (dysplasia, megapolicalycosis).


Asunto(s)
Sistema Urinario , Urografía , Niño , Humanos , Riñón/anomalías , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Radiólogos , Sistema Urinario/diagnóstico por imagen , Urografía/métodos
18.
Pediatr Radiol ; 52(2): 228-248, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35022851

RESUMEN

The goal of functional renal imaging is to identify and quantitate irreversible renal damage and nephron loss, as well as potentially reversible hemodynamic changes. MR urography has evolved into a comprehensive evaluation of the urinary tract that combines anatomical imaging with functional evaluation in a single test without ionizing radiation. Quantitative functional MR imaging is based on dynamic contrast-enhanced MR acquisitions that provide progressive, visible enhancement of the renal parenchyma and urinary tract. The signal changes related to perfusion, concentration and excretion of the contrast agent can be evaluated using both quantitative and qualitative measures. Functional evaluation with MR has continued to improve as a result of significant technical advances allowing for faster image acquisition as well as the development of new tracer kinetic models of renal function. The most common indications for MR urography in children are the evaluation of congenital anomalies of the kidney and urinary tract including hydronephrosis and renal malformations, and the identification of ectopic ureters in children with incontinence. In this paper, we review the underlying acquisition schemes and techniques used to generate quantitative functional parameters including the differential renal function (DRF), asymmetry index, mean transit time (MTT), signal intensity versus time curves as well as the calculation of individual kidney glomerular filtration rate (GFR). Visual inspection and semi-quantitative assessment using the renal transit time (RTT) and calyceal transit times (CTT) are fundamental to accurate diagnosis and are used as a basis for the interpretation of the quantitative data. The importance of visual assessment of the images cannot be overstated when analyzing the quantitative measures of renal function.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Niño , Humanos , Riñón/diagnóstico por imagen , Riñón/fisiología , Pelvis Renal , Espectroscopía de Resonancia Magnética , Urografía
19.
Urol Int ; 106(6): 638-643, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34758471

RESUMEN

OBJECTIVE: Patients with bladder cancer (BC) are at risk of developing upper tract urothelial carcinoma (UTUC). Therefore, CT urography is recommended for follow-up. To avoid intravenous contrast agents, retrograde pyelography (RPG) is an alternative. However, it is still unclear whether RPG increases the incidence of UTUC. The aim of this study was to investigate the impact of RPG in the presence of BC on the risk of developing UTUC. PATIENTS AND METHODS: Retrospectively analysing a total of 3,680 RPGs between 2009 and 2016, all patients with simultaneous BC (group 1) and those without synchronous BC (group 2) during RPG were compared. All patients were risk stratified according to the EORTC bladder calculator. In patients without BC during RPG, risk stratification was based on the worst prior tumour characteristics. RESULTS: A total of 145 patients with a history of BC were analysed. Of these, 112 patients underwent RPG with simultaneous BC. UTUC developed in 6 of 112 patients (5.4%) and 58.9% (66/112) had high-risk BC according to the EORTC bladder calculator. In the control group, one out of 33 (3%) patients with metachronous high-risk BC developed UTUC. CONCLUSIONS: Using RPG in the presence of BC did not increase the risk of UTUC. Due to the predominant number of high-risk/high-grade tumours, individual tumour biology appears to be the primary driver for the development of UTUC.


Asunto(s)
Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Neoplasias Urológicas , Carcinoma de Células Transicionales/patología , Humanos , Estudios Retrospectivos , Neoplasias de la Vejiga Urinaria/patología , Urografía
20.
Radiol Med ; 127(6): 577-588, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35381905

RESUMEN

Computed tomography-urography is currently the imaging modality of choice for the assessment of the whole urinary tract, giving the possibility to detect and characterize benign and malignant conditions. In particular, computed tomography-urography takes advantage from an improved visualization of the urinary collecting system due to acquisition of delayed scan obtained after excretion of intravenous contrast medium from the kidneys. Nevertheless, the remaining scans are of great help for identification, characterization, and staging of urological tumors. Considering the high number of diseases, urinary segment potentially involved and patients' features, scanning protocols of computed tomography-urography largely vary from one clinical case to another as well as selection and previous preparation of the patient. According to the supramentioned considerations, radiation exposure is also of particular concern. Italian radiologists were asked to express their opinions about computed tomography-urography performance and about its role in their daily practice through an online survey. This paper collects and summarizes the results.


Asunto(s)
Radiología , Sistema Urinario , Medios de Contraste , Humanos , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda