Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Can J Urol ; 30(5): 11703-11707, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37838999

RESUMO

INTRODUCTION: Liposomal bupivacaine (LB) is a depot formulation of bupivacaine, which releases the drug over 72 hours to prolong local pain control. This retrospective study compares the effect of using LB versus plain bupivacaine on postoperative pain control, length of hospital stay and cost among patients undergoing vaginal reconstructive surgery. MATERIALS AND METHODS: Patients who underwent vaginal reconstructive surgery with levatorplasty and received an injection of 20 cc of either plain bupivacaine or LB for pudendal nerve block were included. The primary outcomes included postoperative narcotic use and subjective pain score. The secondary outcome was postoperative length of stay. Comparisons between groups were performed using the T test, Mann Whitney U and Chi-square tests with p < 0.05 considered significant. RESULTS: Between June 2016 and December 2021, 25 patients had received LB as a pudendal nerve block and 25 had received plain bupivacaine. Demographics between groups were similar. There was no difference between postoperative morphine equivalent dose (MED) for plain bupivacaine versus LB (25.3 ± 65.8 vs. 24.9 ± 31.7 MED; p = 0.159) or length of hospital stay (15.8 ± 12.0 hours vs. 23.8 ± 20.0; p = 0.094). Furthermore, subjective pain was also similar between groups (0 vs. 1.6 ± 2.6, p = 0.68), (4.6 ± 2.3 vs. 4.9 ± 2.0 average POD 1 pain, p = 0.534) and (4.3 ± 2.1 for vs. 4.9 ± 2.1 average POD 2 pain, p = 0.373). CONCLUSION: LB is not superior to plain bupivacaine for controlling pain following vaginal reconstructive surgery, and justification for the exponentially greater cost of LB is not supported. Prospective investigations with larger sample sizes are needed to determine the optimal pain management for levatorplasty in vaginal reconstructive surgery.


Assuntos
Bupivacaína , Manejo da Dor , Feminino , Humanos , Anestésicos Locais , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Estudos Prospectivos , Lipossomos , Analgésicos Opioides
2.
Can J Urol ; 29(6): 11371-11377, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36495579

RESUMO

INTRODUCTION: During in situ lower pole laser lithotripsy, the dependent location may result in increased challenge fragmenting stones and a risk for stone regrowth if residual fragments remain. The purpose of this study was to compare the thulium fiber laser (TFL) with the holmium laser (HL) for in situ lower pole lithotripsy. MATERIALS AND METHODS: In a 3D printed kidney benchtop model, sixty 1 cm BegoStones were placed in the lower pole and fragmented in situ until fragments passed through a 2 x 2 mm mesh. Laser lithotripsy was performed using twelve energy, frequency and fiber size combinations and residual fragments were compared. In addition, laser fiber diameters and subsequent ureteroscope deflections and flow rates were compared between fibers. RESULTS: The TFL resulted in decreased residual fragments compared to the HL (11% vs. 17%, p < 0.001) and the three settings with least residual fragments were all TFL. Compared to the 150 µm TFL (265° deflection), there was a loss of 9° and 34° in the 200 µm TFL and 272 µm HL fibers, respectively. The measured fiber sizes were greater than manufacturer specified fiber size in every instance. Irrigation rates inversely correlated with fiber size. CONCLUSION: The TFL resulted in 35% less residual stone fragments, up to 34° additional deflection, and an increased irrigation rate when compared to the HL. Optimal fragmentation settings are identified to further improve lower pole lithotripsy. The combination of reduced residual fragments, improved deflection, and better flow rates make the TFL advantageous for in situ lower pole lithotripsy.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Litotripsia a Laser/métodos , Túlio , Hólmio , Lasers de Estado Sólido/uso terapêutico , Ureteroscópios
3.
Urology ; 185: 150-156, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38350550

RESUMO

OBJECTIVE: To compare the radiation dose and image quality between flat panel detector (FPD) and traditional image intensifier (II) C-arms at their lowest radiation settings. METHODS: In a ureteroscopy simulation using a cadaver model, the radiation exposure was compared between FPD and II at 4 pulses-per-second (pps) using both low dose and automatic exposure control (AEC) settings. Additionally, the lowest dose settings for each machine were compared (4 pps with low dose in the FPD and 1 pps with low dose in the II). Five trials of 5 minutes were conducted for each setting. Four new optically stimulated luminescent dosimeters were used in each trial to record radiation exposure. Ten blinded urologists completed a survey rating image quality for each setting. RESULTS: When comparing the FPD and II at their lowest possible settings, the FPD produced significantly more radiation (P <.05). Using both machines at 4 pps in low dose mode resulted in no significant difference between C-arms (P >.05). Conversely, operating the C-arms at 4 pps and AEC resulted in significantly higher radiation exposure from the FPD compared to the II (P <.05). There was no significant difference in image quality at each setting. CONCLUSION: FPDs produce significantly more radiation at the lowest settings compared to IIs. Surgeons should employ IIs when reducing radiation exposure as low as possible is imperative, such as when operating on pediatric and pregnant patients.


Assuntos
Exposição à Radiação , Intensificação de Imagem Radiográfica , Humanos , Criança , Doses de Radiação , Imagens de Fantasmas , Simulação por Computador
4.
J Endourol ; 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39155817

RESUMO

BACKGROUND: Urologists frequently activate foot pedals in a low-light operating room (OR). Pedal activation in low-light conditions poses the potential for incorrect pedal activation, potentially leading to increased radiation exposure, patient burns, or OR fires. This study compares speed, accuracy, dark adaptation, and surgeon preference for pedal activation in 4 lighting conditions. MATERIALS AND METHODS: During a simulated percutaneous nephrolithotomy (PCNL), pedals for C-arm, laser, and ultrasonic lithotripter (USL) were randomized to 3 different positions. Urology attendings, residents, and medical students activated pedals in a randomized order in 4 settings: a dark OR with no illumination, an OR with overhead illumination, a dark OR with glowstick illumination, and a dark OR with blacklight illumination. Endpoints included pedal activation time, number of attempted, incomplete, and incorrect activations, dark adaptation, and subjective pedal preference. ANOVA was used for analysis with p<0.05 considered significant. RESULTS: In our study with twenty participants, the mean pedal activation times were significantly faster when using glowstick illumination (6.77 s) and blacklight illumination (5.34 s) compared to the no illumination arm (8.47 s, p <0.001). Additionally, individual pedal activations for the C-arm, laser, and USL were significantly faster with glowstick and blacklight illumination compared to a dark OR (p<0.001 for all). The blacklight illumination arm demonstrated decreased attempted (0.30 vs. 3.45, p<0.001), incomplete (1.25 vs. 7.75, p<0.001), and incorrect activations (0.35 vs. 1.25, p<0.001) compared to the dark setting, while demonstrating no difference compared to having room lights on. Dark adaptation was significantly improved with blacklight illumination compared to having the room lights on (134.5 vs. 140.5 luminance, p<0.001). All participants (100%) preferred illuminated pedals compared to the dark OR, with 90% favoring the blacklight illumination. CONCLUSIONS: During a simulated PCNL, blacklight illumination significantly improved accuracy and efficiency of pedal activation compared to the conventional dark OR, while maintaining the surgeon's dark adaptation.

5.
J Endourol ; 38(1): 53-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37800857

RESUMO

Introduction: A flexible cystoscope is an indispensable tool for urologists, facilitating a variety of procedures in both the operating room and at bedside. Single-use cystoscopes offer benefits including accessibility and decreased burden for reprocessing. The aims of this study were to compare time efficiency and performance of single-use and reusable cystoscopes. Methods: Ten new Ambu® aScope™ 4 Cysto single-use and two Olympus CYF-5 reusable cystoscopes were compared in simulated bedside cystoscopy and benchtop testing. Ten urologists performed simulated cystoscopy using both cystoscopes in a randomized order. Times for supply-gathering, setup, cystoscopy, cleanup, and cumulative time were recorded, followed by a Likert feedback survey. For benchtop assessment, physical, optical, and functional specifications were assessed and compared between cystoscopes. Results: The single-use cystoscope demonstrated shorter supply-gathering, setup, cleanup, and cumulative times (824 vs 1231 seconds; p < 0.05) but a comparable cystoscopy time to the reusable cystoscope (202 vs 212 seconds; p = 0.32). The single-use cystoscope had a higher image resolution, but a narrower field of view. Upward deflection was greater for the single-use cystoscope (214.50° vs 199.45°; p < 0.01) but required greater force (2.5 × ). The working channel diameter and irrigation rate were greater in the reusable cystoscope. While the single-use cystoscope lacked tumor enhancing optical features, it had higher Likert scale scores for Time Efficiency and Overall Satisfaction. Conclusion: The single-use cystoscope demonstrates comparable benchtop performance and superior time efficiency compared to reusable cystoscopes. However, the reusable cystoscope has superior optical versatility and flow rate. Knowledge of these differences allows for optimal cystoscope selection based on procedure indication.


Assuntos
Cistoscópios , Cistoscopia , Humanos , Desenho de Equipamento , Cistoscopia/métodos , Salas Cirúrgicas , Exame Físico
6.
Urolithiasis ; 52(1): 66, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630256

RESUMO

The purpose of this study was to measure and compare renal pelvic pressure (RPP) between prone and supine percutaneous nephrolithotomy (PCNL) in a benchtop model. Six identical silicone kidney models were placed into anatomically correct prone or supine torsos constructed from patient CT scans in the corresponding positions. A 30-Fr renal access sheath was placed in either the upper, middle, or lower pole calyx for both prone and supine positions. Two 9-mm BegoStones were placed in the respective calyx and RPPs were measured at baseline, irrigating with a rigid nephroscope, and irrigating with a flexible nephroscope. Five trials were conducted for each access in both prone and supine positions. The average baseline RPP in the prone position was significantly higher than the supine position (9.1 vs 2.7 mmHg; p < 0.001). Similarly, the average RPP in prone was significantly higher than supine when using both the rigid and flexible nephroscopes. When comparing RPPs for upper, middle, and lower pole access sites, there was no significant difference in pressures in either prone or supine positions (p > 0.05 for all). Overall, when combining all pressures at baseline and with irrigation, with all access sites and types of scopes, the mean RPP was significantly higher in the prone position compared to the supine position (14.0 vs 3.2 mmHg; p < 0.001). RPPs were significantly higher in the prone position compared to the supine position in all conditions tested. These differences in RPPs between prone and supine PCNL could in part explain the different clinical outcomes, including postoperative fever and stone-free rates.


Assuntos
Nefrolitotomia Percutânea , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Pelve Renal , Rim/diagnóstico por imagem , Rim/cirurgia , Cálices Renais , Posicionamento do Paciente
7.
J Endourol ; 38(3): 228-233, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185836

RESUMO

Introduction: Flat-panel detector C-arms (FCs) are reported to reduce radiation exposure and improve image quality compared with conventional image intensifier C-arms (CCs). The purpose of this study was to compare radiation exposure and image quality between three commonly used FCs. Materials and Methods: A cadaver model was placed in the prone position to simulate percutaneous nephrolithotomy. We compared the following three FCs: OEC Elite CFD from GE HealthCare, Zenition 70 from Philips, and Ziehm Vision RFD from Ziehm Imaging. To measure the radiation dose, optically stimulated luminescence dosimeters (OSLDs) were utilized during five 300-second trials, conducted under three settings: automatic exposure control (AEC), AEC with low dose (LD), and LD with the lowest pulse rate (LDLP). Ten blinded urologists evaluated the image quality. Data were statistically analyzed using the analysis of variance (ANOVA) and Tukey's B post hoc tests. Results: In the AEC setting, the Philips C-arm demonstrated lower ventral OSLD exposure (42,446 mrad) compared with both the GE (51,076 mrad) and Ziehm (83,178 mrad; p < 0.001) C-arms. Similarly, in the LD setting, the Philips C-arm resulted in less ventral OSLD exposure (25,926 mrad) than both the Ziehm (30,956 mrad) and GE (38,209 mrad; p < 0.001) C-arms. Meanwhile, in the LDLP setting, the Ziehm C-arm showed less ventral OSLD exposure (4019 mrad) than both the GE (7418 mrad) and Philips (8229 mrad; p < 0.001) C-arms. All three manufacturers received adequate image quality ratings at the AEC and LD settings. However, at LDLP, the Ziehm C-arm received inadequate ratings in 8% of images, whereas both the GE and Philips C-arms received 100% adequate ratings (p = 0.016). Conclusions: Radiation produced by flat-panel C-arms varies dramatically, with the highest exposure (Ziehm) being almost double the lowest (Philips) in AEC. Improved picture quality at the lowest settings may come at the cost of increased radiation dose. Surgeons should carefully select the machine and settings to minimize radiation exposure while still preserving the image quality.


Assuntos
Doses de Radiação , Humanos , Imagens de Fantasmas , Fluoroscopia/métodos
8.
Urolithiasis ; 52(1): 27, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217570

RESUMO

Percutaneous nephrolithotomy confers the highest radiation to the urologist's hands compared to other urologic procedures. This study compares radiation exposure to the surgeon's hand and patient's body when utilizing three different techniques for needle insertion during renal access. Simulated percutaneous renal access was performed using a cadaveric patient and separate cadaveric forearm representing the surgeon's hand. Three different needle-holding techniques were compared: conventional glove (control), a radiation-attenuating glove, and a novel needle holder. Five 300-s fluoroscopy trials were performed per treatment arm. The primary outcome was radiation dose (mSv) to the surgeon's hand. The secondary outcome was radiation dose to the patient. One-way ANOVA and Tukey's B post-hoc tests were performed with p < 0.05 considered significant. Compared to the control (3.92 mSv), both the radiation-attenuating glove (2.48 mSv) and the needle holder (1.37 mSv) reduced hand radiation exposure (p < 0.001). The needle holder reduced hand radiation compared to the radiation-attenuating glove (p < 0.001). The radiation-attenuating glove resulted in greater radiation produced by the C-arm compared to the needle holder (83.49 vs 69.22 mGy; p = 0.019). Patient radiation exposure was significantly higher with the radiation-attenuating glove compared to the needle holder (8.43 vs 7.03 mSv; p = 0.027). Though radiation-attenuating gloves decreased hand radiation dose by 37%, this came at the price of a 3% increase in patient exposure. In contrast, the needle holder reduced exposure to both the surgeon's hand by 65% and the patient by 14%. Thus, a well-designed low-density needle holder could optimize radiation safety for both surgeon and patient.


Assuntos
Nefrolitotomia Percutânea , Exposição Ocupacional , Cirurgiões , Humanos , Nefrolitotomia Percutânea/efeitos adversos , Exposição Ocupacional/análise , Mãos/cirurgia , Fluoroscopia/efeitos adversos , Cadáver , Doses de Radiação
9.
J Endourol ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38959117

RESUMO

Introduction: The thulium fiber laser (TFL) generates a focused beam, which can be transmitted to laser fibers with small core diameters and may facilitate in situ lower-pole lithotripsy. This study compares lithotripsy performance of the 150 and 200 µm TFL in a lower pole benchtop kidney model. Materials and Methods: Using a 3D model printed from an actual kidney, in situ laser lithotripsy was performed on 1 cm lower-pole BegoStones (calcium oxalate monohydrate consistency) using four different settings (all 20W) and two fiber sizes (150 and 200 µm). Procedure time, laser time, total pulse energy, and fiber stripping were compared between the two fibers using an ANOVA or independent t-test. Results: The 150 µm fiber at 0.2 J × 100 Hz had the shortest lasing and procedure time (17.3 and 18.5 minutes) and lowest total pulse energy (20.75 kJ) compared with other study arms (p < 0.001). Overall procedure time, lasing time, and total pulse energy were significantly different between the 8 settings (p < 0.001 for all). At higher frequency (100 and 200 Hz), lasing time was significantly faster compared with 20 and 50 Hz (19.9 vs 27.3 minutes; p < 0.001). Furthermore, the average total procedure time was shorter with 150 µm compared with 200 µm regardless of settings (23.2 vs 29.8 minutes; p < 0.001). Conclusion: The 150 µm fiber results in shorter procedure and lasing time at lower total energy levels during lower-pole in situ lithotripsy. Overall, the fastest setting was 0.2 J and 100 Hz with the 150 µm fiber. Smaller laser fibers can potentially allow more efficient in situ laser lithotripsy with better irrigation and visibility at higher deflection angles.

10.
J Endourol ; 37(11): 1221-1227, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37698888

RESUMO

Introduction and Objective: A variety of laser sources are available to treat bladder stones. The aim of this study was to compare time and cost efficiency of the thulium fiber laser (TFL) to four holmium lasers (HLs) with different powers or technologies, including MOSES™ during simulated cystolithotripsy. Materials and Methods: In a benchtop simulation of laser cystolithotripsy, 25 identical 4-cm BegoStones (calcium oxalate monohydrate consistency) were placed on a grid within a 3D-printed bladder model. Lasers were operated at maximal energy, using a 550 µm fiber. Lasers compared were as follows: 60 W TFL, 120 W HL with MOSES, and conventional 120, 100, and 30 W HLs. Five trials were performed for each laser with endpoints of laser time, total time, number of fiber strippings, and total energy. Cost-effectiveness was modeled using laser purchase price, fiber, and operating room (OR) time cost. ANOVA with Tukey's B post hoc was performed to compare outcomes. Spearman's test was used to assess correlation between laser power and procedure time. Results: The laser and total operating times were significantly different between the five systems (p < 0.001). The 120 W HL with MOSES was the fastest with 60.9 minutes of laser and 68.3 minutes of procedure times, while the 30 W HL was the slowest with 281.2 minutes of laser and 297.5 minutes of procedure times. The 60 W TFL was faster than the 30 W HL, but slower than the higher power HLs. Higher laser power was associated with shorter procedure time (Rs = -0.98; p = 0.002). When estimating cost per procedure, the MOSES HL was the cheapest, but had the highest purchase cost. The TFL was not cost-effective for large bladder stones compared with the 100 W HL. Conclusions: When treating large bladder stones, total laser power was highly correlated with laser and procedure times and the TFL was limited by its total power. The most cost-effective laser for use will depend on the case volume.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos da Bexiga Urinária , Humanos , Cálculos da Bexiga Urinária/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Túlio , Oxalato de Cálcio , Hólmio
11.
Int Urol Nephrol ; 55(10): 2439-2445, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37440005

RESUMO

OBJECTIVE: To investigate the impact of renal function on the risk, severity, and management of radiation cystitis in patients who underwent postoperative radiation therapy for prostate cancer. METHODS: Retrospective data was assessed from patients treated with adjuvant/salvage radiation therapy at a single academic institution between 2006 and 2020. The incidence, severity, and management of radiation cystitis were compared between three groups: CKD 0-2, CKD 3-4, and CKD 5. Associations of clinicopathologic factors with radiation cystitis were assessed in univariate and multivariate Cox regression models. RESULTS: A total of 110 patients who underwent radiation therapy following robot-assisted laparoscopic radical prostatectomy were included. The incidence of radiation cystitis following postoperative radiation therapy was 17% with a median presentation time of 34 months (interquartile range 16-65 months). The incidence of radiation cystitis was 100% in CKD 5 patients compared to 15% in CKD 0-2 and 17% in CKD 3-4 patients (p < 0.001). CKD 5 patients required more treatments, emergency department visits, and longer hospitalization times than CKD 0-4 patients (all p < 0.001). Multivariate analyses identified CKD 5 as the only significant factor associated with radiation cystitis (HR = 10.39, p = 0.026). CONCLUSION: End-stage renal failure is associated with the risk and severity of radiation cystitis in patients receiving postoperative radiation therapy. Knowledge of the potential morbidity of this complication in this population could guide physicians and patients as they evaluate risks and benefits prior to selecting adjuvant or salvage radiation therapy.


Assuntos
Cistite , Falência Renal Crônica , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Prostatectomia/efeitos adversos , Falência Renal Crônica/complicações , Cistite/etiologia , Cistite/cirurgia , Terapia de Salvação , Antígeno Prostático Específico
12.
Urol Pract ; 10(6): 666-670, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37498667

RESUMO

INTRODUCTION: This study investigated the effectiveness of buprenorphine as an alternative to the use of conventional opioids perioperatively in an effort to help mitigate the impact of the use of perioperative conventional opioids for patients undergoing robotic-assisted laparoscopic prostatectomy. METHODS: Outcomes of patients with localized prostate cancer undergoing robotic-assisted laparoscopic prostatectomy were examined before and after implementation of novel quality improvement study that included receiving buprenorphine compared to conventional opioids for pain control intraoperatively and postoperatively. The primary end point was adequate pain control with secondary end points being analgesic consumption at home, opioid-related side effects, and patient satisfaction. RESULTS: When analyzing the secondary end point of oral morphine milligram equivalents, the buprenorphine group received significantly less morphine milligram equivalent compared to the conventional opioid group (15.19 vs 47.91, P = .006). The buprenorphine group also had lower reported pain scores at discharge (4.3; scale 1-10) compared to the conventional opioid group (5.4), though this did not reach significance (P = .069). In the buprenorphine group, 76.9% strongly agreed that their pain was adequately controlled in the hospital compared to 57.5% of the conventional opioid group (P = .223). There was no difference in overall satisfaction at postoperative day 5 (P = .358). CONCLUSIONS: Our study demonstrates buprenorphine's analgesic capabilities to maintain adequate pain control and patient satisfaction compared to conventional opioids during robotic-assisted laparoscopic prostatectomy, while decreasing perioperative opioid use.

13.
J Endourol ; 36(9): 1249-1254, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35302382

RESUMO

Introduction and Objective: The novel thulium fiber laser (TFL) has been shown to break stones more rapidly than the holmium:YAG laser (HL). However, some evidence suggests that the TFL generates more heat. The purpose of this study is to compare ureteral temperatures generated by these lasers during ureteroscopic laser lithotripsy in a benchtop model. Methods: A 1-cm BegoStone was manually impacted in the proximal ureter of a three-dimensional printed kidney-ureter model and submerged in 35.5°C saline. Lithotripsy was performed using a 7.6F flexible ureteroscope and a 200 µm laser fiber without a ureteral access sheath. The Dornier 30 W HL, Olympus 100 W HL, and Olympus 60 W TFL were compared. A needle thermocouple to measure temperature was inserted 2 mm from the laser tip. Irrigation was maintained at 35 cc/minute at room temperature using the Thermedx FluidSmart System. Intraluminal temperature was continuously recorded for 60 seconds of laser activation. Five trials were performed for each of four different power settings: 3.6, 10, 20, and 30 W. Analysis of variance and Mann-Whitney U tests were performed with p < 0.05 considered significant. Results: Intraureteral fluid temperature increased as laser power settings increased for all lasers (p < 0.05). The TFL generated higher average ureteral fluid temperatures than the Dornier and Empower HL at all power settings tested (p < 0.001). The maximum temperature for the TFL was higher than the Dornier and Empower HL at all power settings tested (p < 0.001), except at 20 W with the Empower HL. At 30 W, the TFL exceeded 43°C, the threshold for tissue damage. Conclusions: The TFL generated more heat at all settings tested. Supraphysiologic ureteral temperatures may be generated with extended use at high energy settings and low irrigation rates. Understanding the heat generation properties of both lasers could help improve the safety of ureteroscopic laser lithotripsy.


Assuntos
Queimaduras , Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Hólmio , Humanos , Lasers de Estado Sólido/efeitos adversos , Litotripsia a Laser/métodos , Túlio , Ureter/cirurgia , Ureteroscópios
14.
Turk J Urol ; 47(1): 58-65, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33112732

RESUMO

OBJECTIVE: Sacral neuromodulation (SNM) is an advanced treatment option for patients with refractory overactive bladder (OAB) symptoms, urinary retention, and bowel disorders; it is usually performed in 2 separate procedures. This study aims to determine a cohort's progression rate from stage 1 to 2 and predict factors for progression and unplanned device removal or revision. MATERIAL AND METHODS: A retrospective review was conducted in patients who underwent SNM at a single institution between June 2012 and May 2019. Progression rates from stage 1 to 2, patient characteristics, and indications for unplanned SNM removal or revision were recorded. Chi-square, Mann-Whitney U, and Fisher's exact tests were used for data analysis. RESULTS: A total of 128 patients underwent SNM for 1 or more of the following diagnoses: OAB (n=103), urinary retention (n=15), neurogenic bladder dysfunction (n=4), fecal incontinence (n=2), and constipation (n=4). The progression rate to stage 2 was 92.2% (118/128). Patients who failed to progress to stage 2 had additional diagnoses other than OAB, such as urinary retention or bowel disorders (p=0.007). Fifteen patients (12.7%) required SNM removal or revision within 4 years of surgery. Among these patients, the body mass index was significantly lower (p=0.036). CONCLUSION: Most patients (92.2%) progressed to stage 2. Patients with only OAB symptoms had a higher progression rate to stage 2. Single full-stage procedures may be considered in select patients to reduce morbidity, time, and costs.

15.
J Endourol ; 34(5): 629-636, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32070125

RESUMO

Introduction and Objectives: To determine the optimal guidewire for bypassing an impacted ureteral stone. Materials and Methods: Three different benchtop models of varying impaction (300, 362, and 444 mm Hg pressure) were used to compare the ability of 13 different guidewires to bypass an impacted ureteral stone. In the first and second models, we recorded the maximum force required to bypass the stone. In the first model (300 mm Hg) 10 new wires for each of the 13 types were advanced past a ureteral stone using a series 5 digital force gauge. In the second model (362 mm Hg), the top 5 performing guidewires were similarly tested. In the third model (444 mm Hg), 5 attending urologists and 5 urology residents (blinded to wire type) compared the 13 guidewires and rated the wire performance using a Likert scale. Statistical analysis was performed with analysis of variance and the chi-square test. Results: In the first model, there was a significant difference between wires (p < 0.001) with the lowest mean force to bypass a stone seen in the Glidewire (0.117 ± 0.02 lbs) and HiWire (0.130 ± 0.01 lbs). Of the five wires tested in the second model, the Glidewire (0.24 ± 0.09 lbs) and UltraTrack (0.40 ± 0.35 lbs) both required less force than the other three wires (p = 0.018). In the third model, only two wires (Roadrunner and Glidewire) bypassed the impacted stone in 100% of trials. When comparing standard, hybrid, and hydrophilic wires, the hydrophilic had the highest success rate (standard = 0%, hybrid = 36.67%, and hydrophilic = 70.67%; p = 0.000) and Likert score (standard = 1.03, hybrid = 2.38, and hydrophilic = 3.24; p = 0.000). Hydrophilic wires required the least time to bypass the stone (hybrid = 82.81 seconds vs hydrophilic = 45.37 seconds, p = 0.000). Conclusions: In this benchtop study, standard wires performed poorly and hybrid wires were not as effective as hydrophilic wires. The Glidewire required the least force, the shortest insertion time, and had the highest surgeon satisfaction rating.


Assuntos
Cálculos Ureterais , Humanos , Cálculos Ureterais/cirurgia
16.
J Endourol Case Rep ; 5(3): 128-130, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32775645

RESUMO

Background: Autosomal dominant polycystic kidney disease is the most prevalent hereditary renal disease, associated with progressive renal insufficiency, usually leading to dialysis. It is rarely diagnosed with other renal abnormalities. We present a case of a 35-year-old woman with a duplicated left polycystic kidney, who had recurrent pain and pyelonephritis because of ureteropelvic junction (UPJ) obstruction of the upper moiety. Case Presentation: A 35-year-old female patient initially presented with left flank pain for 7 days. Evaluation demonstrated enlarged bilateral polycystic kidneys with the appearance of a duplicated system of the left kidney and UPJ obstruction of the upper moeity. She underwent endoscopic management, including balloon dilatation and stent placement. After stent removal she had no symptoms, and ultrasonography showed resolution of the upper pole hydronephrosis. Conclusion: Minimally invasive nephron sparing approaches for UPJ obstruction could delay the process of end-stage renal disease development in polycystic kidney disease patients who have additional congenital renal anomalies. Balloon dilatation should be considered as a feasible therapy for UPJ obstruction in polycystic kidney disease patients with duplicated systems.

17.
J Endourol ; 33(8): 626-633, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31088307

RESUMO

Introduction and Objectives: Fluoroscopy units are routinely operated in the automatic brightness control (ABC) mode to optimize image quality. During ureteroscopy, objects may be placed within the fluoroscopy beam and the effect upon radiation exposure is unknown. The purpose of this study is to investigate the effects of equipment within the fluoroscopy beam during simulated ureteroscopy. Methods: ABC fluoroscopy of a cadaver was performed in eight clinical scenarios, including a control (no equipment), and seven groups with different equipment within the fluoroscopy beam. Equipment tested included electrocardiogram (EKG) leads, a Kelly clamp, camera and light cords (straight and coiled configurations), flexible ureteroscope, rigid cystoscope, and the lateral table support beam. Ten 145-second fluoroscopy trials were performed for each arm. The primary outcome was radiation dose (mGy) compared using the Mann-Whitney test with p < 0.05 considered significant. Results: Compared with control (18.5 mGy), radiation exposure was significantly increased with the presence of a straight camera and light cords (19.3 mGy), Kelly clamp (19.4 mGy), coiled camera and light cords (20.2 mGy), a flexible ureteroscope (21.0 mGy), a rigid cystoscope (21.2 mGy), and when the lateral table support beam was in the path of the X-ray (25.0 mGy; a 35% increase; p < 0.007 for all). The EKG leads did not affect the radiation dose. Conclusions: Avoiding equipment within the fluoroscopy beam using ABC mode can reduce radiation exposure. Adjusting the table and patient position to exclude the lateral table support beam will reduce radiation exposure by 35%.


Assuntos
Cistoscópios , Fluoroscopia/métodos , Mesas Cirúrgicas , Doses de Radiação , Exposição à Radiação , Instrumentos Cirúrgicos , Ureteroscópios , Ureteroscopia/métodos , Cadáver , Instalação Elétrica , Eletrodos , Humanos
20.
Med Oncol ; 29(3): 1928-34, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21904836

RESUMO

This study was conducted to investigate the association of genetic polymorphisms in the MnSOD and GPX1 genes with the risk and invasiveness of bladder cancer in a Turkish population. This prospectively designed study enrolled 157 patients with bladder cancer (mean age 63.2 ± 10.86 years) and 224 healthy controls (mean age 61.7 ± 8.39 years). Genotyping of the MnSOD Ala-9Val and GPX1 Pro198Leu polymorphisms was carried out by PCR-RFLP. No significant difference was found in MnSOD genotype distributions between the controls and the bladder cancer patients. However, the Leu/Leu genotype of GPX1 was associated with a significantly higher risk of bladder cancer than the Pro/Pro genotype. When stratified according to tumor stage, the Leu/Leu genotype of GPX1 was more frequently observed in bladder cancer patients with high-stage tumors than those with low-stage tumors. Additionally, patients carrying both Ala/Ala of MnSOD and Leu/Leu of GPX1 had the highest risk of developing bladder cancer. In conclusion, the present study indicates that the GPX1 Pro198Leu polymorphism may be associated with the risk and development of invasive bladder cancer. In addition, the combination of the MnSOD Ala/Ala and GPX1 Leu/Leu genotypes may have a synergistic effect on disease risk.


Assuntos
Carcinoma de Células de Transição/genética , Predisposição Genética para Doença/genética , Glutationa Peroxidase/genética , Superóxido Dismutase/genética , Neoplasias da Bexiga Urinária/genética , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo de Fragmento de Restrição , Polimorfismo de Nucleotídeo Único , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Turquia , Glutationa Peroxidase GPX1
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa