Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Vasc Surg ; 77(6): 1598-1606.e3, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36822256

RESUMO

OBJECTIVE: To investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent. METHODS: The COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier: NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards. RESULTS: Two hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001). CONCLUSIONS: The use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Grau de Desobstrução Vascular , Desenho de Prótese , Resultado do Tratamento , Stents , Itália , Procedimentos Endovasculares/efeitos adversos , Sistema de Registros
2.
Emerg Radiol ; 28(4): 735-742, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33604768

RESUMO

PURPOSE: To evaluate the feasibility of triple rule out computed tomography (TRO-CT) in an emergency radiology workflow by comparing the diagnostic performance of cardiovascular and general radiologists in the interpretation of emergency TRO-CT studies in patients with acute and atypical chest pain. METHODS: Between July 2017 and December 2019, 350 adult patients underwent TRO-CT studies for the assessment of atypical chest pain. Three radiologists with different fields and years of expertise (a cardioradiologist-CR, an emergency senior radiologist-SER, and an emergency junior radiologist-JER) retrospectively and independently reviewed all TRO-CT studies, by trans-axial and multiplanar reconstruction only. Concordance rates were then calculated using as reference blinded results from a different senior cardioradiologist, who previously evaluated studies using all available analysis software. RESULTS: Concordance rate was 100% for acute aortic syndrome (AAS) and pulmonary embolism (PE). About coronary stenosis (CS) for non-obstructive (<50%), CS concordance rates were 97.98%, 90.91%, and 97.18%, respectively, for CR, SER, and JER; for obstructive CS (>50%), concordance rates were respectively 88%, 85.7%, and 71.43%. Moreover, it was globally observed a better performance in the evaluation of last half of examinations compared with the first one. CONCLUSIONS: Our study confirm the feasibility of the TRO-CT even in an Emergency Radiology department that cannot rely on a 24/7 availability of a dedicated skilled cardiovascular radiologist. The "undedicated" radiologists could exclude with good diagnostic accuracy the presence of obstructive stenosis, those with a clinical impact on patient management, without needing time-consuming software and/or reconstructions.


Assuntos
Dor no Peito , Embolia Pulmonar , Adulto , Dor no Peito/diagnóstico por imagem , Angiografia Coronária , Serviço Hospitalar de Emergência , Humanos , Radiologistas , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
Surg Technol Int ; 38: 331-338, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-34000753

RESUMO

Although the endovascular approach is the therapeutic option of choice for thoracic and abdominal aortic diseases, open surgery is still the treatment of choice for aortic arch diseases. While open surgical repair remains the gold standard treatment for complete aortic arch replacement, it continues to be burdened by high mortality and neurologic complications, especially for patients who require redo surgery. Therefore, in the era of endovascular surgery, it is not surprising that hybrid operating rooms, new technologies, and new approaches are strongly challenging open surgery. Less-invasive endovascular procedures, when used to treat aortic arch diseases, when feasible and indicated, have clear advantages over open surgery, primarily because there is no need for cardiopulmonary bypass, hypothermic circulatory arrest, or cerebral protection. Moreover, patients who have already been treated for acute type A aortic dissection continue to have a considerable risk for future aortic reintervention, which is associated with increased risk for short- and long-term mortality. In light of these advantages, it is clear how selected high-risk patients with aortic arch disease could benefit from the endovascular approach. However, the hemodynamic and anatomic characteristics of the aortic arch make the endovascular approach in this region challenging. In fact, uncorrected stent-graft placement can have fatal consequences for the patient and increase the risk of endoleaks and stroke. To minimize these potential risks, precise and accurate preoperative planning to achieve optimal stent-graft dimensions and implantation is essential together with careful patient selection. Endovascular options for the treatment of aortic arch disease include both hybrid procedures and total endovascular solutions. This manuscript provides an overview of the current strategies for endovascular aortic arch treatment, including the most recent available series on this topic. In addition, a literature search offers insight into the current state of the art.


Assuntos
Aneurisma da Aorta Torácica , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Prótese Vascular , Humanos , Fatores de Risco , Stents , Resultado do Tratamento
4.
Eur Radiol ; 26(2): 359-69, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26003792

RESUMO

OBJECTIVE: To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. METHODS: Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). RESULTS: Image quality (aortic root-ascending portion) was average-to-excellent in more than 94% of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50%, with only 21.5% of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8% (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6% (p < 0.001). CONCLUSIONS: Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. KEY POINTS: • CT image quality of aortic root-ascending aorta is challenging. • Non ECG-gated scans are often limited by pulsatility artefacts. • ECG-gated examinations are usually limited by high radiation doses. • Non ECG-gated 128-slice low dose CTAA provides high quality images. • 128-slice CTAA low dose protocol could frequently replace ECG-gated CTAA.


Assuntos
Aortografia/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Meios de Contraste , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Rotação , Adulto Jovem
5.
Radiol Med ; 119(9): 667-73, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24297597

RESUMO

OBJECTIVE: The authors sought to evaluate the diagnostic accuracy of high-resolution computed tomography (HRCT) in the detection of pulmonary veno-occlusive disease (PVOD) in patients with pre-capillary pulmonary arterial hypertension (PAH) of unknown aetiology, and to identify the role of CT in diagnosis and therapy. MATERIALS AND METHODS: The CT scans of 96 patients were retrospectively reviewed and assessed for specific HRCT findings: ground-glass opacities, septal lines and mediastinal lymph nodal enlargement (short diameter ≥1 cm). According to the HRCT findings, patients were divided into PVOD-suspicious and not PVOD-suspicious. Subsequently, a clinical-instrumental evaluation was performed, and the response to therapy and histopathological reports were evaluated. RESULTS: Radiological evaluation based on HRCT findings revealed 29 patients as PVOD-suspicious and 67 as not PVOD-suspicious. The final diagnosis was PVOD in 22 patients and idiopathic PAH in 74 patients. The CT scan showed 95.5 % sensitivity, 89% specificity, 72.5% positive predictive value, and 98.5% negative predictive value, with a diagnostic accuracy of 90.5% in identifying patients with PVOD. CONCLUSIONS: Chest CT can be considered a screening test in the assessment of patients with PAH of unknown aetiology, and the radiologist can help the clinician to identify patients with CT findings that make PVOD highly probable.


Assuntos
Pneumopatia Veno-Oclusiva/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
G Ital Cardiol (Rome) ; 24(9): 731-739, 2023 09.
Artigo em Italiano | MEDLINE | ID: mdl-37642124

RESUMO

Aortic dissection is a life-threatening condition caused by a tear in the tunica intima which creates a false lumen into the aortic wall. Acute type B aortic dissection (TBAD) is defined by the presence of the entry tear in the aorta distal to the left subclavian artery, without ascending aorta and arch involvement, and accounts for 25-40% of all aortic dissections. Optimal medical therapy (OMT), focused on blood pressure and heart rate control, remains the gold standard treatment, especially for patients with uncomplicated TBAD, while complicated dissections require surgical therapy. Recent studies have shown that a considerable number of patients treated only with OMT develop late aorta-related complications that increase morbidity and mortality, as well as the need for surgical intervention. During the last decades, emerging evidence indicates that thoracic endovascular aortic repair (TEVAR) is safe and effective in the treatment of TBAD, both complicated and uncomplicated, with improved long-term survival outcomes and aortic remodeling in combination with OMT compared to OMT alone. However, in cases of acute uncomplicated TBAD the optimal timing for TEVAR is not entirely clarified and there is lack of long-term evidence. Therefore, the role of pre-emptive TEVAR for these patients is still uncertain and the management of acute uncomplicated TBAD remains challenging.


Assuntos
Dissecção Aórtica , Humanos , Seguimentos , Dissecção Aórtica/cirurgia , Aorta , Pressão Sanguínea , Correção Endovascular de Aneurisma
7.
Indian J Thorac Cardiovasc Surg ; 39(Suppl 2): 224-232, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38093927

RESUMO

Purpose: Frozen elephant trunk (FET) was born as an ideal one-step procedure to treat complex arch and descending thoracic aorta pathology. It was then proved that it frequently needs reintervention, which can often be performed by thoracic endovascular aortic repair (TEVAR) extension since FET provides a safe proximal landing zone. We hereby describe our experience in TEVAR extension after FET, its main indications, technique, and outcomes. Methods: Between 2007 and 2022, 371 patients underwent FET at our center. Of these, 119 needed TEVAR extension. Some required more than one TEVAR, with a total of 154 procedures. The preoperative characteristics, indications, and outcomes were analyzed retrospectively. Results: Of 154 TEVAR procedures, 15 were performed in an urgent setting. Mean time from FET to TEVAR was 22,2 ± 28,73 months. Two patients died in the operating room; no others died during the hospital stay. Survival after 1, 2, 5, and 10 years was 96.2%, 93.9%, 90.1%, and 70.5% respectively. There was no statistically significant difference in the rates of TEVAR extension for patients in which a Thoraflex™ vs E-vita™ graft was used, nor for zone 2 vs zone 3 anastomosis and stent length. Conclusion: Though TEVAR extension is often required after FET, it is a safe and effective procedure with excellent post-operative outcomes in the short-, mid-, and long-term and allows successful treatment of complex aortic pathologies. Rigorous and specialized follow-up after FET is central to identify the right moment to intervene.

8.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37878821

RESUMO

OBJECTIVES: Acute aortic syndromes are associated with poor outcomes, despite diagnostic and therapeutic advances. We analysed trends in volumes and outcomes from 2000 to 2021. METHODS: The study population includes 494 type A acute aortic syndromes (TAAAS) (54.2%) and 418 type B acute aortic syndromes (TBAAS) (45.8%). Primary outcomes were in-hospital mortality, long-term survival and freedom from aortic reoperation. RESULTS: Regardless the type of acute aortic syndrome, patient volumes increased over time. Patients with TBAAS were older, more likely to have comorbid conditions and previous cardiac surgery (P < 0.001), while cerebrovascular accidents were more frequent in TAAAS (P < 0.05). Among TAAAS, 143 (28.9%) required total arch and 351 (71.1%) hemiarch replacement. TBAAS management was medical therapy in 182 (43.5%), endovascular in 198 (47.4%) and surgical in 38 (9.1%) cases. Overall in-hospital mortality was 14.6% [18.2% in TAAAS (95% confidence interval (CI) 14.4-21.2%) vs 10.7% in TBAAS (95% CI 7.8%-13.7%); P = 0.0027]. After propensity score adjustment, in-hospital mortality exhibited a significantly decreasing trend from 2000 to 2021 (P < 0.001) in TAAAS and TBAAS. 1-, 5- and 10-year survival was 74.2%, 62.2% and 45.5% in TAAAS and 75.4%, 60.7% and 41.0% in TBAAS (P = 0.975), with no differences among treatment strategies. The adjusted cumulative reoperation risk at 10 years was more than two-fold in TBAAS versus TAAAS (9.5% vs 20.5%, hazard ratio (HR) = 2.30, 95% I 1.31-4.04). CONCLUSIONS: In the last decades, better patient triage and surgical/endovascular techniques led to substantial improvements in the management of acute aortic syndrome, with reduction in early mortality and reoperation rate. However, long-term mortality is still >50%.


Assuntos
Síndrome Aórtica Aguda , Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/cirurgia , Reoperação , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco
9.
Cardiovasc Diagn Ther ; 13(2): 408-417, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37583692

RESUMO

Background: The introduction of hybrid total arch replacement with the frozen elephant trunk (FET) technique has improved the field of aortic surgery by allowing single-stage treatment of complex aortic pathologies. Although FET has been associated with favorable aortic remodeling, it is also associated with the potential development of distal stent graft-induced new entries (dSINEs). The aim of our review is to collect data about the incidence and the supposed conditions for the occurrence of dSINE after total hybrid arch replacement with FET technique. Methods: The literature review was performed using PubMed databases from inception to January 2022. A descriptive approach to detect and display supposed risk factors and predictors for dSINE occurrence has been adopted. Results: Eight studies summarized the state-of-the-art of dSINE in a total number of 544 FET procedures performed to treat acute and chronic aortic dissections. The scoping review showed dSINEs occurrence in 69 patients (12.7%). The mean time between surgery and the diagnosis ranged from 12.6 to 30.6 months. Most patients that developed dSINE received endovascular treatment, whereas a couple of them needed open surgery. According to our experience, from January 2007 to December 2021, in 225 FET procedures a total of 54 cases of dSINE, both with Thoraflex and E-vita grafts have been detected. The mean time between the surgical procedure and the diagnosis was 27.2±33.6 months. Conclusions: dSINEs are frequent complications after FET. Although not emergent, they require proper treatment. Due to dSINE's asymptomatic nature and potential harm, a rigorous follow-up including angio-computed tomography (CT) should be planned.

10.
Eur Radiol ; 22(5): 1059-66, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22205444

RESUMO

OBJECTIVES: To correlate the severity of lung neovascularity (Sheehan vessels) with the cause and haemodynamic severity of pulmonary arterial hypertension (PAH), pulmonary artery (PA) size and heart disease type in patients with PH associated with congenital heart diseases (PAH-CHD) and idiopathic PH (IPAH). METHODS: We reviewed the HRCT and CT pulmonary angiography studies of 87 patients with PAH-CHD and 111 with IPAH; all had undergone right heart catheterisation. We evaluated the PA size and severity of neovascularity on CT. RESULTS: Neovascularity, which was found in 72% of PAH-CHD (56% with Eisenmenger's syndrome) and in 22% of IPAH patients, is significantly related to the severity of PH and all patients with severe neovascularity had intermediate or high PH. All PAH-CHD patients had a dilated PA with a greater risk of developing severe dilatation (diameter >5 cm). The neovascularity correlated with the PA size only in IPAH. CONCLUSIONS: Neovascularity even if not pathognomonic for PAH-CHD, is significantly more common in these patients, especially in Eisenmenger's syndrome. It is often the first CT sign to indicate the severity of PH in PAH-CHD and IPAH. A neovascularity ≥5 on CT indicates a intermediate or high PH. KEY POINTS: • Large retrospective studying specific lung disorders in patients with pulmonary arterial hypertension. • Neovascularity is often the first CT sign indicating the severity of pulmonary hypertension Alterations of lung parenchyma on CT in pulmonary hypertension are described • The first study to assess the severity of pulmonary hypertension by CT • If substantiated, CT might eventually replace some cardiac catheterisation for evaluating PH.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/epidemiologia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/epidemiologia , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Idoso , Angiografia/estatística & dados numéricos , Comorbidade , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
11.
J Cardiovasc Thorac Res ; 14(3): 205-207, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36398049

RESUMO

We report a case of a 56-year-old male who underwent Frozen Elephant Trunk procedure for residual type A chronic aortic dissection, complicated by the release of the distal endovascular portion of the hybrid prosthesis in the false lumen. This complication was successfully treated with a totally endovascular approach.

12.
JTCVS Open ; 10: 12-21, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36004263

RESUMO

Objective: Thoracic endovascular aortic repair (TEVAR) is the treatment of choice for thoracic aorta diseases including penetrating aortic ulcer (PAU). The objective of this study was to analyze the results of TEVAR for the treatment of PAU in our population. Methods: From January 1999 to January 2019, 830 patients with type B aortic syndromes were treated with TEVAR in our institution. Of these we selected 73 patients treated for a PAU. Clinical and radiologic follow-up was performed in all patients. Results: Mean age of our population was 72 ± 8 years. Fifteen patients (20.5%) were treated in an emergency setting. The proximal landing zone was in arch zone 2 in 22 patients (30.1%). In-hospital mortality was 6.8% and was associated with acute presentation (P = .005). Distal arch delivery of the endograft was unrelated to mortality (Fisher exact test, P = .157). Survival at 1 and 5 years was 81.7% and 67.3%, respectively. Sixteen patients underwent reintervention of the thoracic aorta. Patients who underwent emergency surgery and older patients had a shorter survival (log rank test, P < .001). No difference in survival was shown according to the proximal landing zone (log rank P = .292) or the dimension of the thoracic aorta (log rank P = .067). In multivariable Cox regression analysis, only age older than 75 years was associated with 5-year mortality (hazard ratio, 6.60; 95% CI, 2.12-20.56); P < .001). Conclusions: The use of TEVAR for treatment of aortic PAU is a safe procedure in an elective setting despite necessity of arch stent grafting. An early intervention performed at smaller aortic diameters of <55 mm might be beneficial in selected patients to improve late survival.

13.
Int J Cardiol ; 335: 26-31, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33838151

RESUMO

BACKGROUND: The aims of this study were to analyse the incidence of visceral malperfusion syndrome (MPS) following Frozen Elephant trunk operations in patients affected by chronic aortic dissection and the associated risk factors. METHODS: Between January 2007 and February 2019, 165 patients underwent surgery with FET for chronic aortic dissection. Post-operative computer tomography angiogram parameters (diameters, early post-operative false lumen enhancement and involving of aortic branches by the dissection) were collected and analysed to evaluate their impact on the occurrence of visceral malperfusion. RESULTS: Visceral (renal and mesenteric) MPS (with both clinical and radiological signs of MPS) was detected in 10 cases (6.1%). Post-operative visceral malperfusion was strongly related with in hospital mortality. The involvement of the visceral branches in the dissection was not a risk factor for visceral malperfusion occurrence, while a larger post-operative total aortic diameter at level of the coeliac trunk increased the risk of visceral MPS (OR 1.05; CI 1.002-1.102, p-value = 0.04). Furthermore, visceral MPS was associated to a complete thrombosis of the false lumen at level of the distal descending thoracic aorta. CONCLUSIONS: The development of post-operative MPS in frozen elephant trunk is strongly related to in-hospital mortality. The involvement of aortic branches by the dissection does not represent a real predictive risk factor for MPS, while early larger aortic diameters and false lumen thrombosis represent independent risk factors for MPS and in-hospital mortality.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
14.
Integr Cancer Ther ; 19: 1534735419900554, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32009477

RESUMO

Background: Primary soft tissue sarcomas arising from the male urinary and genital tract are rare tumors, only accounting for 1% to 2% of all malignancies of the genitourinary tract. Clinical management of advanced disease is lacking in standardized recommendations due to the rarity of the disease. To date, complete and extensive surgery represents the only curative and standardized approach for localized disease, while the impact of retroperitoneal lymphadenectomy and adjuvant treatments on clinical outcomes are still unclear. Similarly, a standardized systemic treatment for advanced metastatic disease is still missing. Cases Presentation: Four out of 274 patients have been identified in our sarcoma population. The mean age was 54 years (range = 45-73). The histotypes showed liposarcoma in 2 cases and leiomyosarcoma in the remaining 2 cases. In all 4 cases, the disease was localized at presentation, patients underwent complete surgery, and no adjuvant treatments were done. Three cases presented a recurrence of disease at a mean follow-up of 86 months (range = 60-106 months), more than 7 years. Two cases were treated with a second surgery and chemotherapy and 1 case only with chemotherapy. Discussion and Conclusions: Sharing data about clinical management of paratesticular mesenchymal tumors is a key issue due to the rarity of this tumor's subtype. In this article, we report the clinical history of 4 patients affected by paratesticular mesenchymal tumor. In particular, main issues of interest are the decision of postoperative treatment and systemic treatment at time of disease recurrence.


Assuntos
Dor Abdominal/etiologia , Neoplasias Testiculares/patologia , Testículo/patologia , Dor Abdominal/diagnóstico por imagem , Idoso , Herniorrafia , Humanos , Excisão de Linfonodo , Masculino , Pessoa de Meia-Idade , Orquiectomia , Sarcoma/patologia , Sarcoma/cirurgia , Neoplasias Testiculares/cirurgia , Tomógrafos Computadorizados , Resultado do Tratamento
15.
Interact Cardiovasc Thorac Surg ; 28(1): 23-28, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29961884

RESUMO

OBJECTIVES: The aim of this study was to evaluate a new self-expanding tract sealant device, designed to prevent pneumothorax after computed tomography (CT)-guided lung biopsy, as an intraoperative marker for small pulmonary nodules or ground-glass opacities during minimally invasive thoracic surgery. METHODS: Three patients with pulmonary nodules underwent CT-guided biopsies in our radiology department. During the same procedure, using a 19-gauge coaxial needle, a self-expanding tract sealant device was positioned in the lung nodule to be used not only for the prevention of pneumothorax but also as an intraoperative marker. A few days later, conventional thoracoscopic surgery was scheduled. A visual examination was performed. The site of the deployment of the BioSentry device was determined by checking for the proximal end of it beyond the visceral pleura. Thoracoscopic wedge resections using endoscopic staplers were performed to confirm histological characteristics, surgical margins and correct placement of the plug. RESULTS: Three consecutive patients underwent CT-guided placement of this self-expanding tract sealant device (BioSentry) before surgery, without complications. The thoracoscopic resection was performed with success. The plug was easy to visualize with the scope, and all removed nodules had surgical free margins and the plug was correctly positioned in all patients. CONCLUSIONS: The self-expanding tract sealant device was created for the reduction of pneumothorax and chest tube placement rates after percutaneous lung biopsy. We used it for the first time for intraoperative localization of peripheral small solid nodules or ground-glass opacities with good results.


Assuntos
Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/cirurgia , Pulmão/diagnóstico por imagem , Pneumonectomia/instrumentação , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico , Nódulos Pulmonares Múltiplos/cirurgia , Pneumotórax/prevenção & controle , Nódulo Pulmonar Solitário/diagnóstico , Cirurgia Assistida por Computador
16.
World J Clin Cases ; 7(19): 3018-3026, 2019 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-31624749

RESUMO

BACKGROUND: Cardiac tumors are rare and complex entities. Surgery represents the cornerstone of therapy, while the role of adjuvant treatment remains unclear and, in case of relapse or metastatic disease, the prognosis is very poor. Lack of prospective, randomized clinical trials hinders the generation of high level evidence for the optimal diagnostic workup and multimodal treatment of cardiac sarcomas. Herein, we describe the multidisciplinary clinical management and molecular characterization of a rare case of cardiac myxofibrosarcoma in an elderly woman. CASE SUMMARY: A 73-year-old woman presented signs and symptoms of acute left-sided heart failure. Imaging examination revealed a large, left atrial mass. With suspicion of a myxoma, she underwent surgery, and symptoms were promptly relieved. Histology showed a cardiac myxofibrosarcoma, a rare histotype of cardiac sarcoma. Eight months later, disease unfortunately relapsed, and after a multidisciplinary discussion, a chemotherapy with doxorubicin and then gemcitabine was started, achieving partial radiologic and complete metabolic response, which was maintained up to 2 years and is still present. This report is focused on the entire clinical path of our patient from diagnosis to follow-up, through surgery and strategies adopted at relapse. Moreover, due to their rarity, very little is known about the molecular landscape of myxofibrosarcomas. Thus, we also performed and described preliminary genome analysis of the tumor tissue to get further insight on mechanisms involved in tumor growth, and to possibly unveil new clinically actionable targets. CONCLUSION: We report a case of cardiac myxofibrosarcoma that achieved a very good prognosis due to an integrated surgical, cardiac and oncologic treatment strategy.

18.
J Vis Surg ; 4: 116, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29963405

RESUMO

We present a case of a 48-year-old female patient with Marfan syndrome and previous open surgeries for Bentall procedure and arch replacement with frozen elephant trunk (FET) technique, who was admitted at our Department with a diagnosis of ascending aorta pseudoaneurysm at the anastomosis-site between composite valve graft and arch prosthesis treated by endovascular procedure because of she was considered to be at high-risk for a third open surgery and for the patient's favorable anatomy for endovascular closure of the pseudoaneurysm. The patient was successfully treated with the positioning of two abdominal cuffs through the left axillary artery. The postoperative course was uneventful and at 2-month follow-up, the patient was free of complications with CT angiogram showing complete endovascular exclusion of the pseudoaneurysm.

19.
J Vis Surg ; 4: 63, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29682473

RESUMO

Pulmonary sequestration (PS) is a rare congenital malformation of the respiratory tract. Two main variants are described, the intralobar and the extralobar PS. Clinical manifestations vary from accidental findings to life threatening complications. Surgical resection is the definitive and indicated treatment of PS. The operation could be performed through an open thoracotomy or video-assisted thoracic surgery approach. We report the management of two patients with diagnosis of extralobar PS in the first case and intralobar PS in the second case. Both patients underwent uniportal video-assisted thoracic surgery resection of PS with success. In our experience, we confirm that uniportal video-assisted thoracic surgery is a safe and feasible approach for extralobar and intralobar PS.

20.
Ann Thorac Surg ; 102(2): 527-32, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27112653

RESUMO

BACKGROUND: Aortic dissection is a major cardiovascular disease associated with a high mortality rate. In complicated type B dissection, with favorable anatomy, endovascular surgical repair (thoracic endovascular aortic repair [TEVAR]) is considered the treatment of choice. Intimomedial injury induced by stent graft, or stent graft-induced new entry (SINE), has a clinically significant incidence. SINE can occur at the proximal or distal level of the stent graft. The aim of this retrospective study was to investigate the incidence, mechanism, and predictive factors of late distal SINE. METHODS: We reviewed 139 discharged patients after TEVAR for type B or residual aortic dissection after type A surgery, from January 2007 to March 2013. Three intervals of computed tomography imaging were collected, including before and after primary TEVAR and with the first detection of distal SINE. Four accessible measurement methods for precise size selection of the stent graft before and after the procedure were analyzed at the distal end level of the primary stent graft. RESULTS: Among the 139 patients, only 108 had complete preoperative and follow-up imaging and were enrolled in the study. The mean age of the patients was 59.7 ± 11.7 years, and 92 patients (85.2%) were men. Seventy had type B aortic dissection, and 38 had residual aortic dissection after type A surgery. The mean follow-up period was 36.1 ± 25.7 months. During follow-up, distal SINE occurred in 30 patients (27.8%), and 18 of them (60%) underwent secondary TEVAR whereas the remaining 12 patients were medically treated. No statistically significant differences in demographic and clinical conditions were seen between patients with or patients without SINE. The incidence of SINE was lower for acute than for chronic dissection (16% versus 50%). At the multivariate analysis, the independent factors associated with SINE development were the oversizing ratio of the area (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p = 0.018) and of the mean diameter (odds ratio 1.858; 95% confidence interval: 1.109 to 3.064; p = 0.018). CONCLUSIONS: Type B aortic dissection can be treated effectively with TEVAR. The incidence of distal SINE is not negligible but is not associated with poor outcomes. The main determinant of SINE seems to be an excessive oversizing, which is particularly evident in the distal end. More accurate sizing can be obtained by evaluating the area of the true lumen.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aortografia/métodos , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa