Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; : e14416, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38812120

RESUMO

BACKGROUND AND PURPOSE: This study recommends clinical epidermal dose calculation methods based on in-vivo film measurements and registered skin dose distributions with the Eclipse (Varian Medical Systems) treatment planning system's Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms. MATERIALS AND METHODS: Eighteen AAA V13.6 breast plans were recalculated using AXB (dose to medium) V13.5 with the same beam parameters and monitor units as in the original plans. These are compared against in-vivo Gafchromic film measurements from the lateral and inferior breast regions. Three skin structures in the treatment planning system are evaluated: a surface layer of voxels of the body contour, a 0.2 cm internal skin rind, and a 0.5 cm internal skin rind. RESULTS: Systematic shifts are demonstrated between the film measurements of skin dose and the Eclipse dose calculations. On average, the dose to the surface layer of pixels is underestimated by AAA by 8% and overestimated by AXB by 3%. A 5 mm skin rind extended into the body can increase epidermal dose calculations on average by 8% for AAA and 4% for AXB. CONCLUSION: This is the first study to register in-vivo skin dose distributions in the breast to the treatment planning system for comparison. Based on the results from this study it is recommended that epidermal dose is calculated with a 0.5 cm skin rind for the AAA algorithm and with rind thickness up to 0.2 cm for the AXB algorithm.

2.
J Appl Clin Med Phys ; 25(6): e14269, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38235952

RESUMO

INTRODUCTION: Dynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the "Boolean OAR Method" and the "Aperture Sorting Method," to determine if they can successfully spare an OAR while maintaining sufficient target coverage. MATERIALS AND METHODS: A step-and-shoot intensity modulated radiation therapy (sIMRT) treatment plan was re-optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the "Boolean OAR Method" created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the "Aperture Sorting Method" assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose. RESULTS: All 10 OARs exceeded their dose constraints on the original plan four-dimensional (4D) dose distributions and average target coverage was V100% = 91.3% ± 2.9% (ranging from 85.1% to 94.8%). The "Boolean OAR Method" spared 7/10 OARs, and mean target coverage decreased to V100% = 87.1% ± 3.8% (ranging from 80.7% to 93.7%). The "Aperture Sorting Method" spared 9/10 OARs and the mean target coverage remained high at V100% = 91.7% ± 2.8% (ranging from 84.9% to 94.5%). CONCLUSIONS: 4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The "Boolean OAR Method" improved sparing of OARs but target coverage was reduced. The "Aperture Sorting Method" further improved sparing of OARs and maintained target coverage.


Assuntos
Órgãos em Risco , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Radiocirurgia/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Respiração , Algoritmos , Tomografia Computadorizada Quadridimensional/métodos , Movimento
3.
J Appl Clin Med Phys ; 22(6): 16-25, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34042251

RESUMO

PURPOSE: In this study we present a novel method for re-calculating a treatment plan on different respiratory phases by accurately modeling the panning and tilting beam motion during DTT (the "rotation method"). This method is used to re-calculate the dose distribution of a plan on multiple breathing phases to accurately assess the dosimetry. METHODS: sIMRT plans were optimized on a breath hold computed tomography (CT) image taken at exhale (BHexhale ) for 10 previous liver stereotactic ablative radiotherapy patients. Our method was used to re-calculate the plan on the inhale (0%) and exhale (50%) phases of the four-dimensional CT (4DCT) image set. The dose distributions were deformed to the BHexhale CT and summed together with proper weighting calculated from the patient's breathing trace. Subsequently, the plan was re-calculated on all ten phases using our method and the dose distributions were deformed to the BHexhale CT and accumulated together. The maximum dose for certain organs at risk (OARs) was compared between calculating on two phases and all ten phases. RESULTS: In total, 26 OARs were examined from 10 patients. When the dose was calculated on the inhale and exhale phases six OARs exceeded their dose limit, and when all 10 phases were used five OARs exceeded their limit. CONCLUSION: Dynamic tumor tracking plans optimized for a single respiratory phase leave an OAR vulnerable to exceeding its dose constraint during other respiratory phases. The rotation method accurately models the beam's geometry. Using deformable image registration to accumulate dose from all 10 breathing phases provides the most accurate results, however it is a time consuming procedure. Accumulating the dose from two extreme breathing phases (exhale and inhale) and weighting them properly provides accurate results while requiring less time. This approach should be used to confirm the safety of a DTT treatment plan prior to delivery.


Assuntos
Neoplasias Pulmonares , Neoplasias , Tomografia Computadorizada Quadridimensional , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Respiração
4.
Adv Radiat Oncol ; 9(1): 101318, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38260224

RESUMO

Purpose: Moist desquamation (MD) is a concerning acute side effect of radiation therapy for breast cancer, often seen in skin folds for patients having large or pendulous breasts. In vivo skin dosimetry, clinical assessments, and patient-reported skin reactions were used to determine a relationship between dose-area metrics and the development of MD, to lend insight into skin tolerances and possibly guide future treatment planning dose constraints. Methods and Materials: Skin dose was measured using GafChromic film on the inner surface of an early prototype carbon-fiber accessory for breast support to remove the inframammary fold in 20 patients at high risk of developing MD undergoing adjuvant whole breast radiation therapy. Prescribed doses were 42.5 Gray (Gy) in 16 fractions or 50 Gy in 25 fractions using 6 to 15 MV x-rays. To account for fraction size differences, analysis was performed using the equivalent dose in 2 Gy fractions using α/ß = 11 (EQD211). MD was assessed out to 2 weeks post radiation therapy by trained therapists and by a patient-reported outcome questionnaire. Results: Statistically significant differences in areas receiving 30 to 48 Gy (EQD211) were observed between patients who did and did not develop MD in the inframammary area. Patients receiving EQD211 maximum dose ≤ 46 Gy and ≥ 38 Gy to ≤ 50 cm2 of their breast skin did not develop MD. Conclusions: The findings of this study offer insight into the relationship between skin toxicity and areas of skin irradiated to doses up to 50 Gy. Potential skin dose constraints to test in future studies to prevent MD are suggested.

5.
J Med Phys ; 48(1): 50-58, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37342609

RESUMO

Purpose and Aim: The Vero4DRT (Brainlab AG) linear accelerator is capable of dynamic tumor tracking (DTT) by panning/tilting the radiation beam to follow respiratory-induced tumor motion in real time. In this study, the panning/tilting motion is modeled in Monte Carlo (MC) for quality assurance (QA) of four-dimensional (4D) dose distributions created within the treatment planning system (TPS). Materials and Methods: Step-and-shoot intensity-modulated radiation therapy plans were optimized for 10 previously treated liver patients. These plans were recalculated on multiple phases of a 4D computed tomography (4DCT) scan using MC while modeling panning/tilting. The dose distributions on each phase were accumulated to create a respiratory-weighted 4D dose distribution. Differences between the TPS and MC modeled doses were examined. Results: On average, 4D dose calculations in MC showed the maximum dose of an organ at risk (OAR) to be 10% greater than the TPS' three-dimensional dose calculation (collapsed cone [CC] convolution algorithm) predicted. MC's 4D dose calculations showed that 6 out of 24 OARs could exceed their specified dose limits, and calculated their maximum dose to be 4% higher on average (up to 13%) than the TPS' 4D dose calculations. Dose differences between MC and the TPS were greatest in the beam penumbra region. Conclusion: Modeling panning/tilting for DTT has been successfully modeled with MC and is a useful tool to QA respiratory-correlated 4D dose distributions. The dose differences between the TPS and MC calculations highlight the importance of using 4D MC to confirm the safety of OAR doses before DTT treatments.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa