Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Catheter Cardiovasc Interv ; 88(2): 239-43, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26893203

RESUMO

A failing intracardiac device is traditionally addressed by open-heart surgery. Surgical explantation of the device, although a simple procedure, carries risks that some patients are not able or willing to cope with. Thus, a nonsurgical option seems desirable in selected cases. We report on four cases of early malfunction of the Polyvinyl Alcohol membrane of Ultrasept II™ CARDIA ASD devices. In all cases, transthoracic echo (TTE) surveillance 4-6 months after the index procedure, depicted significant left-to-right atrial shunts through the center portion of the devices. A second nitinol double disk device with a connecting pin (Lifetech CERA™ Multifenestrated ASD device) was implanted over the CARDIA devices, with excellent results. All procedures were uneventful and all patients are asymptomatic with no residual shunts, in short-term follow-up. This device-in-device technique prevents surgical explantation of failing ASD devices, and may become a less invasive option in selected patients. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Falha de Prótese , Dispositivo para Oclusão Septal , Adolescente , Adulto , Ligas , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Membranas Artificiais , Pessoa de Meia-Idade , Álcool de Polivinil , Desenho de Prótese , Retratamento , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 83(2): 315-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23703798

RESUMO

We report on a 57-year-old patient suffering from advanced squamous cell carcinoma of the left lung, ultimately submitted to intrapericardial left pneumonectomy with hilar and mediastinal lymphadenectomy. Imaging examination showed a left bronchopleural fistula that needed to be occluded. Due to the patient's high surgical risk, endobronchial closure with intracardiac device was performed. The ASD CERA™ device (Lifetech Schenzhen, China) was chosen. The procedure was successful and the patient was discharge from the hospital 5 days thereafter. Endobronchial closure of bronchopleural fistulas with intracardiac devices is feasible and may become an excellent option for those very ill patients.


Assuntos
Fístula Brônquica/terapia , Broncoscopia/instrumentação , Carcinoma de Células Escamosas/cirurgia , Neoplasias Pulmonares/cirurgia , Doenças Pleurais/terapia , Pneumonectomia/efeitos adversos , Fístula do Sistema Respiratório/terapia , Dispositivo para Oclusão Septal , Fístula Brônquica/diagnóstico , Fístula Brônquica/etiologia , Carcinoma de Células Escamosas/patologia , Desenho de Equipamento , Humanos , Neoplasias Pulmonares/patologia , Excisão de Linfonodo , Masculino , Pessoa de Meia-Idade , Doenças Pleurais/diagnóstico , Doenças Pleurais/etiologia , Fístula do Sistema Respiratório/diagnóstico , Fístula do Sistema Respiratório/etiologia , Resultado do Tratamento
3.
AsiaIntervention ; 9(1): 70-77, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36936101

RESUMO

Percutaneous left atrial appendage closure (LAAC) has proven to be an effective alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). International guidelines traditionally recommend LAAC for NVAF patients at high thromboembolic risk and contraindication to or at high risk for OAC. However, there are many other clinical situations in which this procedure may also be beneficial. This paper discusses the potential role of LAAC in specific haemorrhagic diseases (cerebral amyloid angiopathy, age-related macular degeneration, hereditary haemorrhagic telangiectasia, and Moyamoya disease), after left atrial appendage (LAA) electrical isolation, in cases of persistent thrombus inside the LAA, in end-stage renal disease and in special groups of patients for whom low compliance and persistence to OAC may be anticipated.

4.
Arq Bras Cardiol ; 119(1): 48-56, 2022 07.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35544849

RESUMO

BACKGROUND: Left atrial appendage (LAA) closure has been an alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVES: To report the first results of an initial multicenter experience in Brazil and to investigate the feasibility, safety, and efficacy of LAA closure with the new LAmbre device. METHODS: We collected procedural and follow-up data of 51 consecutive patients with non-valvular atrial fibrillation, restrictions for long-term OAC and suitable anatomy that underwent LAA closure with the LAmbre device in 18 centers in Brazil. Procedural indications were significant bleeding under OAC (47.1%), stroke or persistent LAA thrombus despite OAC (27.5%), bleeding plus stroke (17.6%), other clinical contraindications for OAC (5.9%), and patient's choice due to sports practice (1.9%). RESULTS: Twenty-five men (49%) and 26 women (51%), with a mean age of 76±7.7 years, mean CHA2DS2-VASc score of 4.6± 1.7 and mean HAS-BLED score of 3.4± 1.1 were studied. Procedural success rate was 100%. Procedure-related immediate complications were pericardial effusion in two patients, and immediate device embolization in one case. No large residual shunts (> 5 mm) were observed, and small shunts (<5mm) were detected in four patients by color Doppler at the end of the procedure. After a mean follow-up of 18 ± 12 months, there were no deaths, strokes nor any other major complications. CONCLUSION: LAA occlusion with the LAmbre device was safe and effective in this small case series. Despite these encouraging initial results, the small number of cases warrants further studies with longer-term follow-up.


FUNDAMENTO: A oclusão do apêndice atrial esquerdo (AAE) tem se mostrado uma alternativa à terapia de anticoagulação oral (ACO) para prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não valvar (FANV). OBJETIVOS: Descrever os primeiros resultados de uma experiência inicial multicêntrica no Brasil e investigar a viabilidade, a segurança e a eficácia da oclusão do AAE com o novo dispositivo LAmbre. MÉTODOS: Coletamos dados do procedimento e do acompanhamento de 51 pacientes consecutivos com FANV, restrições para ACO em longo prazo e com anatomia adequada, submetidos à oclusão do AAE com o dispositivo LAmbre em 18 centros no Brasil. Indicações para o procedimento foram: sangramento importante em pacientes recebendo ACO (47,1%), AVC ou trombo persistente no AAE apesar de ACO adequada (27.5%), sangramento e AVC (17.6%), outras contraindicações clínicas apara ACO (5,9%), e escolha do paciente devido à prática esportiva (1,9%). RESULTADOS: Foram estudados 25 homens (49%) e 26 mulheres (51%), com idade média de 76±7,7 anos, escore CHA2DS2-VASc médio de 4,6± 1,7 e escore HAS-BLED médio de 3.4± 1,1. A taxa de sucesso do procedimento foi de 100%. As complicações imediatas relacionadas ao procedimento foram derrame pericárdico em dois pacientes, e embolização do dispositivo em um caso. Não foram observados shunts residuais > 5mm. Shunts < 5mm foram detectados em quatro pacientes por Doppler colorido ao final do procedimento. Após um período médio de acompanhamento de 18 meses ± 12 meses, não foram observados óbito, AVC ou complicações maiores. CONCLUSÃO: A oclusão do AAE com o dispositivo LAmbre foi segura e eficaz nesta pequena série de casos. Apesar desses resultados iniciais encorajadores, dado o pequeno número de casos, serão necessários mais estudos com um maior período de acompanhamento.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Brasil , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
5.
J. Transcatheter Interv ; 31(supl.1): 4-4, jul.-set. 2023.
Artigo em Português | SES-SP, CONASS, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1512160

RESUMO

INTRODUÇÃO: O implante percutâneo de valva pulmonar foi introduzido em 2000 como uma alternativa de baixo risco para pacientes previamente operados com disfunção da via de saída do ventrículo direito (VSVD). Até recentemente, pacientes com VSVD nativas e ectásicas não eram candidatos a essa terapêutica devido à ausência de um dispositivo adequado a esta população no Brasil. O advento da MyVal (Meril Life Sciences, Gujarat, India), uma válvula balão-expansível, com diâmetros de 30,5mm e 32mm proporcionou o tratamento destes pacientes que frequentemente já possuem cirurgias prévias com risco cirúrgico de nova intervenção muito alto. OBJETIVO: Descrever os resultados imediatos da experiência inicial brasileira do implante de MyVal em vias de saída nativas e ectásicas em diferentes centros do país. MÉTODOS: 14 pacientes foram submetidos ao implante percutâneo de MyVal para o tratamento da disfunção da via de saída nativa e ectásica. A idade média dos pacientes foi de 31,3 anos (14-67) e o peso médio de 66,4 Kg (40-90). Todos os pacientes, à exceção de um idoso que havia sido diagnosticado com estenose de valva pulmonar, foram submetidos a, pelo menos, um procedimento cirúrgico previamente. RESULTADOS: O implante foi bem-sucedido em todos os pacientes, tendo sido realizado sem pré-stent. A via de saída mediu em média 27,6mm (20-32) e após a insuflação de balão Cristal 30mm, mediu em média 29,8mm (28-32,5). Foram implantadas 3 valvas 30,5mm com diâmetro final médio de 30,1mm (30- 30,5) e 11 valvas 32mm com diâmetro final de 32,8mm (32-35). Não houve complicações ou mortalidade relacionadas ao procedimento Todos os pacientes apresentaram insuficiência pulmonar trivial no ecocardiograma antes da alta hospitalar. CONCLUSÕES: Atualmente, esta é a maior experiência mundial implante de valva pulmonar com MyVal de calibres 30,5 e 32mm. O implante de valva pulmonar é um procedimento seguro e efetivo que substitui a troca valvar cirúrgica e beneficia principalmente pacientes com toracotomias prévias. O implante da MyVal de calibres de 30,5 e 32mm propiciou o tratamento de pacientes com vias de saída ectásicas e que não possuíam alternativa percutânea atualmente no Brasil. Diâmetro final pode chegar a 35mm sem o surgimento de insuficiência pulmonar. Pré-stent não é necessário na maioria dos casos.


Assuntos
Disfunção Ventricular Direita , Próteses e Implantes
6.
Arq. bras. cardiol ; 120(5 supl. 6): 15-15, maio. 2023.
Artigo em Português | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1443654

RESUMO

FUNDAMENTO: O implante percutâneo de valva pulmonar foi introduzido em 2000 como uma alternativa de baixo risco para pacientes previamente operados com disfunção da via de saída do ventrículo direito (VSVD). Até recentemente, pacientes com VSVD nativas e ectásicas não eram candidatos a essa terapêutica devido à ausência de um dispositivo adequado a esta população no Brasil. O advento da MyVal (Meril Life Sciences, Gujarat, India), uma válvula balãoexpansível, com diâmetros de 30,5mm e 32mm proporcionou o tratamento destes pacientes que frequentemente já possuem cirurgias prévias com risco cirúrgico de nova intervenção muito alto. OBJETIVO: Descrever os resultados imediatos da experiência inicial brasileira do implante de MyVal em vias de saída nativas e ectásicas em diferentes centros do país. Amostra e MÉTODOS: 13 pacientes foram submetidos ao implante percutâneo de MyVal para o tratamento da disfunção da via de saída nativa e ectásica. A idade média dos pacientes foi de 32,6 anos (14-67) e o peso médio de 69,3Kg (45-90). Todos os pacientes, à exceção de um idoso que havia sido diagnosticado com estenose de valva pulmonar, foram submetidos a, pelo menos, um procedimento cirúrgico previamente. RESULTADOS: O implante foi bem-sucedido em todos os pacientes, tendo sido realizado sem pré-stent. A via de saída mediu em média 27,7mm (20-32) e após a insuflação de balão Cristal 30mm, mediu em média 29,8mm (28-32). Foram implantadas 4 valvas 30,5mm com diâmetro final médio de 30,3mm (30-30,5) e 9 valvas 32mm com diâmetro final de 33,3mm (32- 35). Não houve complicações ou mortalidade relacionadas ao procedimento Todos os pacientes apresentaram insuficiência pulmonar trivial no ecocardiograma antes da alta hospitalar. CONCLUSÃO: Atualmente, esta é a maior experiência mundial implante de valva pulmonar com MyVal de calibres 30,5 e 32mm. O implante de valva pulmonar é um procedimento seguro e efetivo que substitui a troca valvar cirúrgica e beneficia principalmente pacientes com toracotomias prévias. O implante da MyVal de calibres de 30,5 e 32mm propiciou o tratamento de pacientes com vias de saída ectásicas e que não possuíam alternativa percutânea atualmente no Brasil. Diâmetro final pode chegar a 35mm sem o surgimento de insuficiência pulmonar. Préstent não é necessário na maioria dos caso. Palavras-chave: cateterismo; congênitos; implante de valva pulmonar.


Assuntos
Substituição da Valva Aórtica Transcateter , Valvuloplastia com Balão
7.
Arq. bras. cardiol ; 119(1): 48-56, abr. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1383717

RESUMO

Resumo Fundamento A oclusão do apêndice atrial esquerdo (AAE) tem se mostrado uma alternativa à terapia de anticoagulação oral (ACO) para prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não valvar (FANV). Objetivos Descrever os primeiros resultados de uma experiência inicial multicêntrica no Brasil e investigar a viabilidade, a segurança e a eficácia da oclusão do AAE com o novo dispositivo LAmbre. Métodos Coletamos dados do procedimento e do acompanhamento de 51 pacientes consecutivos com FANV, restrições para ACO em longo prazo e com anatomia adequada, submetidos à oclusão do AAE com o dispositivo LAmbre em 18 centros no Brasil. Indicações para o procedimento foram: sangramento importante em pacientes recebendo ACO (47,1%), AVC ou trombo persistente no AAE apesar de ACO adequada (27.5%), sangramento e AVC (17.6%), outras contraindicações clínicas apara ACO (5,9%), e escolha do paciente devido à prática esportiva (1,9%). Resultados Foram estudados 25 homens (49%) e 26 mulheres (51%), com idade média de 76±7,7 anos, escore CHA2DS2-VASc médio de 4,6± 1,7 e escore HAS-BLED médio de 3.4± 1,1. A taxa de sucesso do procedimento foi de 100%. As complicações imediatas relacionadas ao procedimento foram derrame pericárdico em dois pacientes, e embolização do dispositivo em um caso. Não foram observados shunts residuais > 5mm. Shunts < 5mm foram detectados em quatro pacientes por Doppler colorido ao final do procedimento. Após um período médio de acompanhamento de 18 meses ± 12 meses, não foram observados óbito, AVC ou complicações maiores. Conclusão A oclusão do AAE com o dispositivo LAmbre foi segura e eficaz nesta pequena série de casos. Apesar desses resultados iniciais encorajadores, dado o pequeno número de casos, serão necessários mais estudos com um maior período de acompanhamento.


Abstract Background Left atrial appendage (LAA) closure has been an alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). Objectives To report the first results of an initial multicenter experience in Brazil and to investigate the feasibility, safety, and efficacy of LAA closure with the new LAmbre device. Methods We collected procedural and follow-up data of 51 consecutive patients with non-valvular atrial fibrillation, restrictions for long-term OAC and suitable anatomy that underwent LAA closure with the LAmbre device in 18 centers in Brazil. Procedural indications were significant bleeding under OAC (47.1%), stroke or persistent LAA thrombus despite OAC (27.5%), bleeding plus stroke (17.6%), other clinical contraindications for OAC (5.9%), and patient's choice due to sports practice (1.9%). Results Twenty-five men (49%) and 26 women (51%), with a mean age of 76±7.7 years, mean CHA2DS2-VASc score of 4.6± 1.7 and mean HAS-BLED score of 3.4± 1.1 were studied. Procedural success rate was 100%. Procedure-related immediate complications were pericardial effusion in two patients, and immediate device embolization in one case. No large residual shunts (> 5 mm) were observed, and small shunts (<5mm) were detected in four patients by color Doppler at the end of the procedure. After a mean follow-up of 18 ± 12 months, there were no deaths, strokes nor any other major complications. Conclusion LAA occlusion with the LAmbre device was safe and effective in this small case series. Despite these encouraging initial results, the small number of cases warrants further studies with longer-term follow-up.

8.
Arq Bras Cardiol ; 109(5): 440-447, 2017 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29069203

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). OBJECTIVE: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. METHODS: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. RESULTS: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). CONCLUSIONS: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
10.
Arq Neuropsiquiatr ; 63(2B): 427-9, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16059593

RESUMO

OBJECTIVE: Although its role is a matter of debate, some studies described a higher prevalence of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in young stroke patients, with higher risk with PFO / ASA association (OR 4.96). The aim of this study was determine the prevalence of PFO and ASA in a cohort of cryptogenic ischemic stroke (IS) patients younger than 55 years and to follow-up after surgical or percutaneous endovascular closure (PEC). METHOD: In 21 months we identified all patients less than 55 years old with IS who were admitted to our hospital. Cryptogenic IS was considered if there is not an identifiably cause to cerebral ischemia. Transesophageal echocardiography (TEE) was performed in all patients. After interatrial septal abnormalities diagnosis, percutaneous device closure was offered to all. Patients were followed monthly and keeped with oral AAS or Clopidogrel. RESULTS: We identified 189 patients with IS and 32 were less than 55 years old (16.9%). In 29 the IS was cryptogenic. TEE was performed in all patients and some form of interatrial septal abnormality was identified in 12 (12/29 - 41.3%); 5 had a PFO and in 7 there was PFO plus ASA. Ten patients were submitted to PEC and 2 were submitted to surgical closure. In mid-term follow-up (28 months) no ischemic events occurred and 2 patients related disappearance of migraine symptoms. CONCLUSION: Our small series description is in accordance with other studies and suggests a possible relation between interatrial septal abnormalities and IS in a cohort of young patient.


Assuntos
Isquemia Encefálica/etiologia , Comunicação Interatrial/epidemiologia , Aneurisma Intracraniano/epidemiologia , Adulto , Brasil/epidemiologia , Estudos de Coortes , Feminino , Comunicação Interatrial/complicações , Humanos , Aneurisma Intracraniano/complicações , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia
11.
Expert Rev Cardiovasc Ther ; 2(2): 253-64, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15151473

RESUMO

The isolated perimembranous ventricular septal defect is one of the most common congenital cardiac malformations. Although surgery has been performed and has a low associated risk, it still involves morbidity due to factors such as residual leaks, atrioventricular block, postpericardiotomy syndrome and arrhythmias. It has been speculated that percutaneous closure of these defects could minimize such complications. Recently, a device designed specifically for perimembranous ventricular septal defect closure, the Amplatzer membranous ventricular septal defect occluder, has been developed. Initial clinical experience with this device has been very encouraging with results showing a high rate of complete closure and a low incidence of complications at mid-term follow-up. In this article, the authors review their own and others' experience with this device.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Transesofagiana , Seguimentos , Comunicação Interventricular/diagnóstico por imagem , Humanos , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos
12.
Arq Bras Cardiol ; 81(5): 435-52, 2003 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-14666265

RESUMO

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 3.3mm, and 15.2 3.8mm, respectively. The Qp/Qs ratio was 1.9 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Próteses e Implantes , Adolescente , Adulto , Análise de Variância , Angiocardiografia , Brasil , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Fluoroscopia , Seguimentos , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Humanos
13.
Arq. bras. cardiol ; 109(5): 440-447, Nov. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887971

RESUMO

Abstract Background: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). Objective: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. Methods: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. Results: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). Conclusions: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Resumo Fundamento: A oclusão percutânea do apêndice atrial esquerdo (OAAE) é uma alternativa eficaz à anticoagulação oral (ACO) para a prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não-valvular (FANV). Objetivo: Apresentar os resultados imediatos e o seguimento tardio de pacientes submetidos a OAAE e incluídos no Registro Brasileiro de Oclusão Percutânea do Apêndice Atrial Esquerdo. Métodos: 91 pacientes com FANV, alto risco de AVC (escore CHA2DS2VASc = 4,5 ± 1,5) e restrição à AO (escore HAS-BLED = 3,6 ± 1,0) foram submetidos a 92 procedimentos de OAAE com as próteses Amplatzer Cardiac Plug e Watchman em 11 centros do Brasil, entre o final de 2010 e a metade de 2016. Resultados: Utilizaram-se 96 próteses no total (1,04 próteses/procedimento, incluindo-se o uso de 1 prótese não-dedicada adicional em um dos casos), obtendo-se sucesso em 97,8% dos procedimentos. Realizaram-se procedimentos associados à OAAE em 8,7% dos pacientes. Observou-se oclusão total do AAE em 93,3% dos casos com sucesso, e nos casos de oclusão incompleta, nenhum leak foi > 2,5 mm. Um paciente necessitou do implante simultâneo de 2 próteses. Houve 7 complicações maiores periprocedimento (5 derrames pericárdicos necessitando pericardiocentese, 1 embolização da prótese não-dedicada e 1 embolia aérea coronariana sem sequelas) e 4 menores. No seguimento de 128,6 pacientes-ano, houve 3 óbitos não relacionados ao procedimento, 2 sangramentos maiores (um deles em um dos casos de insucesso da OAAE), formação de trombo sobre a prótese em 2 casos (tratados com sucesso com reinstituição da ACO por 3 meses), e 2 AVCs (2,2%). Conclusões: Neste registro multicêntrico de mundo real, que incluiu pacientes com FANV e alto risco de sangramento e de eventos tromboembólicos, a OAAE foi eficaz na prevenção de AVC e sangramento quando comparada às taxas de AVC previstas pelos escores CHA2DS2VASc e HASBLED para esta população. O índice de complicações do procedimento foi aceitável, considerando se tratar do início da curva de aprendizado da maioria dos operadores envolvidos.


Assuntos
Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal , Fibrilação Atrial/diagnóstico por imagem , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Apêndice Atrial/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia
15.
Rev. bras. cardiol. invasiva ; 23(1): 61-65, abr.-jun.2015. ilus, tab
Artigo em Português | LILACS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: lil-782178

RESUMO

Defeitos congênitos múltiplos são tradicionalmente corrigidos cirurgicamente, mas, atualmente, podem ser tratados percutaneamente. Existem poucos relatos na literatura atestandosua eficácia e segurança. Objetivamos descrever uma experiência com a realização de procedimentoscombinados para tratar diferentes defeitos, congênitos e estruturais, numa mesma sessão terapêutica. Métodos: Desde 2007, foram tratados, numa mesma sessão terapêutica, diferentes defeitos. Todos foram selecionados por ecocardiograma. Os procedimentos foram realizados segundo as técnicas tradicionais já descritas para cada defeito encontrado. Resultados: Foram tratados dez pacientes, cinco do sexo masculino, com idades de 1 a 67 anos, e pesos de 11 a 90 kg. O defeito mais prevalente de forma isolada foi a persistência do canal arterial (PCA, n = 5), seguido da comunicação interatrial ostium secundum (CIA OS, n = 4) e da comunicação interventricular (CIV, n = 4). As combinações mais frequentes foram CIV com PCA (n = 2) e CIV com CIA OS (n = 2). Foram dilatadas duasestenoses valvares pulmonares com CIA OS e com forame oval patente (FOP), e uma coarctação de aorta com PCA. Adicionalmente, foi ocluído um apêndice atrial esquerdo com FOP e foi embolizada uma fístula aortopulmonar com PCA. Todos os procedimentos foram bem-sucedidos. O tempo médio de seguimento foi de 31 ± 28,1 meses, havendo apenas duas complicações. Não houve nenhum óbito. Conclusões: A pequena série de casos relatada mostrou que os procedimentos combinados foram seguros e eficazes, podendo ser reproduzidos por operadores experientes em centros especializados, podendo vir a se constituir como primeira opção terapêutica para esses pacientes...


Multiple congenital defects are traditionally corrected surgically, but nowadays can be treatedpercutaneously. There are few reports in the literature attesting to its efficacy and safety. We aimed to describe an experience with combined procedures to treat different congenital and structural defects, in a single therapeutic session.Methods: Since 2007, different defects were treated in a single treatment session. All were selected byechocardiography. The procedures were performed using traditional techniques already described for each defect.Results: Ten patients were treated, five males, aged 1-67 years, weighting 11-90 kilograms. The most prevalent isolated defect was patent ductus arteriosus (PDA, n = 5), followed by ostium secundum atrial septal defects (ASD, n = 4) and ventricular septal defects (VSD, n = 4). The most common combinations were VSD with PDA (n = 2) and VSD with osASD (n = 2). Two pulmonary valve stenosis were dilated with ASD and patent foramen ovale (PFO), and one aorta coarctation with PDA. Additionally, a left atrial appendage with PFO was occluded and an aorto pulmonary fistula with PDA was embolized. All procedures were successful. The mean follow-up was 31 ± 28.1 months, with only two complications. There were no deaths.Conclusions: The small number of reported cases showed that the combined procedures were safe andeffective and can be reproduced by experienced operators in specialized centers and may be considered asthe first therapeutic option in these patients...


Assuntos
Humanos , Masculino , Feminino , Próteses e Implantes , Cateterismo Cardíaco/métodos , Defeitos dos Septos Cardíacos/terapia , Canal Arterial/anormalidades , Cardiopatias Congênitas/terapia , Comunicação Interatrial/complicações , Comunicação Interatrial/terapia , Ecocardiografia Transesofagiana/métodos , Estenose da Valva Pulmonar/terapia , Forame Oval Patente/terapia
16.
Rev. bras. cardiol. invasiva ; 23(2): 139-144, abr.-jun. 2015. tab, ilus
Artigo em Português | LILACS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: lil-786998

RESUMO

Introdução: A ampla variedade morfológica das coarctações da aorta (CoA) e algumas complicações derivadasdo implante de stents convencionais tornam desejáveis a utilizaçào de stents recobertos (SR). Descrevemos aexperiência com o uso de SR para tratar CoA em crianças e adultos. Métodos: Foram revisados, retrospectivamente, os registros dos pacientes nos quais foram utilizados os SR. Os procedimentos foram realizados segundo a técnica consagrada. Foram estudados casos em que os SRforam utilizados como primeiro tratamento e também aqueles realizados em complicações derivadas doprocedimento inicial. Resultados: Entre 2007 e 2014, foram utilizados SR em 14 pacientes, sendo 9 (64,3%) do sexo masculino. A média de idades foi 19,5 ± 10,5 anos, e a média dos pesos, 61,7 ± 25,5 kg. Valva aórtica bicúspide estavapresente em 74% dos casos, e dois apresentaram persistência do canal arterial. Coarctações subatréticasforam encontradas em cinco pacientes. Onze pacientes apresentaram hipertensão arterial sistêmica, e73% normalizaram as cifras tensionais após a dilatação com stents. O implante foi possível em todos os casos. Foram realizados implantes primários em dez (71,4%) pacientes portadores de coarctações nativas e em quatro como segundo dispositivo, para corrigir problemas derivados de procedimentos anteriores. O tempo médio de seguimento foi de 51,7 ± 29,8 meses. Três complicações menores estiveram relacionadas aos procedimentos, e não houve registro de óbito. Conclusões: O uso de SR foi seguro e eficaz na nossa pequena série de casos. Mais estudos, enfocando a evolução de longo prazo e a possibilidade de redilatação dos SR, são necessários para corroborar seu uso em crianças.


Background: The wide morphological variety of coarctation of the aorta (CoA) and some complications resulting from the implantation of conventional stents has made the utilization of covered stents (CS) desirable. We describe our experience with the use of CS to treat CoA in children and adults. Methods: The records of patients that received CS were retrospectively reviewed. The procedures were performed according to the established technique. Use of CS as primary treatment were assessed, as well as those deployed due to complications resulting from the initial procedure. Results: Between 2007 and 2014, CS were used in 14 patients, 9 (64.3%) of whom were males. The meanage was 19.5 ± 10.5 years, and the mean weight 61.7 ± 25.5 kg. Bicuspid aortic valve was present in 74% ofcases, and two patients had patent ductus arteriosus. Subatretic aortic coarctations were found in five patients. Eleven patients had systemic arterial hypertension, and 73% had normalized blood pressure levelsafter stent dilation. Implantation was possible in all cases. Primary implants were performed in ten (71.4%)patients with native coarctation and in four patients as a second device to correct problems originating from previous procedures. The mean time of follow-up was 51.7 ± 29.8 months. Three minor complicationswere related to procedures, and there were no deaths. Conclusions: The use of CS was safe and effective in this small case series. Further studies focusing on the long-term evolution and the possibility of CS redilation are needed to support its use in children.


Assuntos
Humanos , Masculino , Feminino , Criança , Adulto Jovem , Adulto , Coartação Aórtica/terapia , Criança , Stents , Cardiopatias Congênitas/fisiopatologia , Cateterismo Cardíaco/métodos , Cefazolina/administração & dosagem , Doenças das Valvas Cardíacas/terapia , Heparina/administração & dosagem , Próteses e Implantes , Valva Aórtica/cirurgia
17.
Rev. bras. cardiol. invasiva ; 23(3): 177-182, jul.-set.2015. ilus, tab
Artigo em Português | LILACS | ID: lil-794194

RESUMO

A fibrilação atrial (FA) aumenta o risco de eventos tromboembólicos por êmbolos origina do sem apêndice atrial esquerdo (AAE). Métodos mecânicos para a oclusão do AAE foram desenvolvidos como alternativa à anticoagulação oral. O objetivo deste trabalho foi apresentar uma experiência inicial com o AMPLATZER® Cardiac Plug. Métodos: Incluímos pacientes com FA permanente ou paroxística, que apresentavam contraindicações ou complicações derivadas da anticoagulação oral. Pacientes com anatomia e medidas do AAE compatíveis com o oclusor, e sem trombos foram selecionados por meio de ecocardiograma transesofágico. Resultados: Foram realizados 14 procedimentos em 13 pacientes (5M:8F), com média de idade de 66,7 anos. Sangramento significativo e acidentes vasculares cerebrais prévios foram encontrados em 69,2% e em 53,8%, respectivamente. A FA era permanente em 84,6% e paroxística no restante da amostra. Os diâmetros médiodo óstio e da zona alvo mediram 23,9 mm e 20,8 mm, respectivamente. AAE bilobulados foram observados em 76,9%. Os procedimentos foram possíveis em todos os casos. Dezesseis dispositivos foram usados em 13 pacientes, numa razão de 1,2:1, e apenas 1 paciente precisou de um segundo dispositivo para oclusão do AAE. O tempo médio de acompanhamento foi de 12,2 meses. Todos os AAE permanecem fechados e sem defeito residual até o momento. Houve apenas um óbito tardio não relacionado ao procedimento. Conclusões: A oclusão do AAE com o dispositivo de AMPLATZER® Cardiac Plug mostrou ser segura e eficaz nesta pequena série de pacientes. Os resultados iniciais são encorajadores e apontam para o fechamento transcateter do AAE como alternativa para a anticoagulação oral em pacientes selecionados...


Atrial fibrillation (AF) increases the risk of thromboembolic events caused by embolioriginating in the left atrial appendage (LAA). Mechanical methods for LAA occlusion have been developed as an alternative to oral anticoagulation. The aim of this study was to present an initial experience with the AMPLATZER® Cardiac Plug. Methods: Patients with permanent or paroxysmal AF and with contraindications or complications of oral anticoagulation were included. Patients with LAA anatomy and measures compatible with the occluder, and without thrombi, were selected through transesophageal echocardiography. Results: A total of 14 procedures were performed in 13 patients (5M:8F), with mean age of 66.7 years. Significant bleeding and previous strokes were found in 69.2% and 53.8%, respectively. AF was permanent in 84.6% and paroxysmal in the remainder. The mean diameters of the ostium and the landing zone were 23.9 mm and 20.8mm, respectively. Bilobulated LAA was observed in 76.9%. Procedures were possible in all cases. Sixteen devices were used in 13 patients, a ratio of 1.2:1, and only one patient required a second device for LAA occlusion. The mean follow-up was 12.2 months. All LAA remain closed, with no residual defect to date. There was only one late death, unrelated to the procedure. Conclusions: LAA occlusion using the AMPLATZER® Cardiac Plug device was shown to be safe and effective in this small series of patients. The initial results are encouraging and indicate the transcatheter closure of the LAA as an alternative to oral anticoagulation therapy in selected patients...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acidente Vascular Cerebral , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Fibrilação Atrial/prevenção & controle , Tromboembolia/prevenção & controle , Próteses e Implantes , Angiografia/métodos , Catéteres , Ecocardiografia Transesofagiana/métodos , Fatores de Risco , Heparina/administração & dosagem , Átrios do Coração
18.
Rev. bras. cardiol. invasiva ; 22(3): 264-270, Jul-Sep/2014. graf
Artigo em Português | LILACS-Express | LILACS, SES-SP | ID: lil-732782

RESUMO

Introdução: As comunicações interatriais pequenas são geralmente bem toleradas na infância, mas podem apresentar problemas na vida adulta. O procedimento de oclusão percutânea desses defeitos é seguro e apresenta baixíssimo risco, mas é questionado. Este manuscrito objetivou avaliar os resultados do fechamento de defeitos considerados pequenos e sua evolução a médio prazo. Métodos: Análise retrospectiva dos procedimentos de oclusão em pacientes portadores de comunicações interatriais tipo ostium secundum cujos diâmetros estáticos eram ≤ 6 mm. Resultados: De novembro de 2003 a março de 2014, foram analisados os procedimentos realizados em 34 pacientes, dos quais 22 eram do sexo feminino, com idades variando de 2 a 60 anos. Os diâmetros estáticos variaram de 2 a 6 mm e apresentaram um aumento médio de 55% após o uso do balão medidor. Os implantes foram possíveis em todos os casos e foi utilizado um dispositivo por paciente, de diferentes tipos e marcas. Não ocorreram óbitos e todos os paciente apresentaram oclusão completa de seus defeitos. Houve apenas uma complicação menor durante um procedimento e uma complicação maior, após 4 meses, em outro paciente. Conclusões: A oclusão percutânea de pequenas comunicações interatriais tipo ostium secundum foi segura e eficaz. Os bons resultados ...


Background: Small atrial septal defects are usually well tolerated in childhood but may present problems later in life. The percutaneous occlusion of such defects is safe and presents very low risk, but is questioned. This manuscript was aimed at evaluating the results of the percutaneous occlusion of small defects and patients’ mid-term follow-up. Methods: Retrospective analysis of percutaneous closure procedures performed in patients with ostium secundum atrial septal defects whose static diameters were ≤ 6 mm. Results: From November 2003 to March 2014, procedures performed in 34 patients were evaluated. Of these, 22 were female, with ages ranging from 2 to 60 years. The static diameters ranged between 2 to 6 mm and a mean increase of 55% was observed after balloon sizing. Implants were feasible in all of the cases and each patient received one device, of different types and brands. There were no deaths and all patients had their defects completely closed. There was only one minor complication during the procedure and a major complication 4 months after the procedure in another patient. Conclusions: The percutaneous closure of small ostium secundum atrial septal defects was safe and effective. The good results of occlusion procedures suggest that the use of devices may be considered the treatment of choice for ostium secundum atrial septal defects ≤ 6 mm. .

19.
Rev. bras. cardiol. invasiva ; 22(1): 41-47, Jan-Mar/2014. graf
Artigo em Português | LILACS | ID: lil-712742

RESUMO

Introdução: A oclusão percutânea das comunicações interatriais tipo ostium secundum com as próteses disponíveis comercialmente é procedimento seguro e eficaz. Apresentamos a experiência com duas próteses de nova geração, com fios de nitinol revestidos. Métodos: Descrevemos as características das próteses, a técnica de implante e os resultados de pacientes portadores de comunicações interatriais, tratados com as próteses Lifetech CERA® ASD Occluder e Cocoon Septal Occluder. Resultados: Foram realizados procedimentos em 49 pacientes, sendo 37 do sexo feminino. A idade variou de 7 a 68 anos, e o peso de 17 a 90 kg. A borda aórtica estava presente em 34,7% e aneurisma de septo atrial em 14,3% dos pacientes. Os diâmetros estáticos dos orifícios principais foram de 13 ± 7 mm e os diâmetros estirados de 22 ± 7 mm. O implante foi possível em todos os casos, sendo empregados 55 dispositivos. Foram utilizadas próteses CERA® em 45 pacientes e Cocoon nos demais. Três pacientes necessitaram ocluir um segundo orifício. Durante os procedimentos, foi necessária a substituição da primeira prótese por outra de maior diâmetro em dois casos e por deformidade da prótese (configuração em tulipa) no terceiro caso. A oclusão imediata ocorreu em 91,9% e em 95,9% no 6° mês. Não ocorreram óbitos ou outras complicações significativas. Conclusões: O manuseio das próteses CERA® e Cocoon foi simples e reprodutível nas mãos de operadores experientes. As taxas de oclusão imediata foram semelhantes às obtidas com as próteses Amplatzer®. Mais estudos e seguimento de longo prazo se fazem necessários para determinar as reais vantagens do revestimento dos fios de nitinol.


Background: Transcatheter occlusion of secundum atrial septal defects using commercial available devices is a safe and effective procedure. We present our experience with two new generation coated nitinol wire devices. Methods: We report device characteristics, implantation technique and outcomes of patients with atrial septal defects treated with the Lifetech CERATM ASD Occluder and the Cocoon Septal Occluder. Results: Procedures were performed in 49 patients, 37 were female. Ages ranged from 7 to 68 years and body weight from 17 to 90 kg. The aortic rim was present in 34.7% and atrial septal aneurysms in 14.3% of the patients. Mean diameter was 13 ± 7 mm whereas the balloonstretched diameter was 22 ± 7 mm. Implantation was possible in all cases and 55 devices were used. Fortyfive CERATM and four Cocoon devices were used. Three patients required occlusion of a second orifice. During the procedures the first device had to be replaced by a larger one in two cases, and in the third case it was replaced due to a tuliplike malformation of the left atrial disc. Immediate occlusion occurred in 91.9% and in 95.9% at 6 months. There were no deaths or other significant complications. Conclusions: The use of both CERATM and Cocoon devices was simple and reproducible in experienced hands. Shortterm occlusion rates were similar to the ones obtained with the AmplatzerTM device. More studies and longterm followup are required to determine the actual advantages of coated nitinol wire devices.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Comunicação Interatrial/terapia , Próteses e Implantes , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Estudos Retrospectivos
20.
Rev. bras. cardiol. invasiva ; 22(4): 382-385, Oct-Dec/2015. graf
Artigo em Português | LILACS, SES-SP | ID: lil-744578

RESUMO

A oclusão do apêndice atrial esquerdo tem sido realizada com sucesso para a prevenção de fenômenos embólicos em pacientes com fibrilação atrial, como alternativa à anticoagulação oral. O acesso atrial, através de forame oval ou comunicação interatrial tipo ostium secundum, tem sido evitado em função da crença de que o posicionamento do dispositivo é dificultado pela disposição mais alta do forame no septo interatrial. Neste manuscrito, relatamos um caso em que foram ocluídos, sequencialmente, o apêndice atrial esquerdo e o forame oval sem a necessidade de punção transeptal, que simplificou e tornou mais seguro o procedimento.


Left atrial appendage occlusion has been successfully employed to prevent embolic events in patients with atrial fibrillation as an alternative to oral anticoagulation. Left atrial access through the patent foramen ovale or ostium secundum atrial septal defect has been discouraged due to the fear that entering the septum in a higher position through the foramen would prevent adequate device positioning. In this manuscript we report a case in which the left atrial appendage and the foramen ovale were sequentially occluded avoiding transseptal puncture, making the procedure simpler and faster.


Assuntos
Humanos , Feminino , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Forame Oval Patente/fisiopatologia , Próteses e Implantes , Cateterismo Cardíaco , Comunicação Interatrial , Átrios do Coração/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa