Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
J Card Fail ; 28(6): 963-972, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35041933

RESUMO

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Volume Sistólico
2.
Internist (Berl) ; 63(2): 230-237, 2022 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-34762155

RESUMO

BACKGROUND: Patients with atrial fibrillation are at a significantly increased risk of thromboembolic events, especially ischemic strokes. Oral anticoagulation reduces this risk, but cannot be used in some patients for various reasons and is associated with a relevantly increased risk of bleeding. As an alternative for prophylaxis of thromboembolic events in patients with atrial fibrillation, there are different options of left atrial appendage closure. AIM: This article explains the possibilities of interventional atrial occlusion as well as the suitable patient clientele using an overview of the currently available systems for atrial occlusion, a guideline for patient selection and a summary of the current scientific data. CONCLUSION AND AVAILABLE SCIENTIFIC DATA: In carefully selected patients suffering from atrial fibrillation with relative or absolute contraindications for oral anticoagulation, interventional closure of the atrial appendage is a safe alternative for prophylaxis against thromboembolic events. The currently available scientific evidence from randomized controlled trials is sparse. Nevertheless, extensive amounts of registry study data suggest a benefit, while the results of several large randomized controlled trials are expected in the coming years.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Anticoagulantes/efeitos adversos , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
3.
J Card Surg ; 36(9): 3308-3316, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34173273

RESUMO

BACKGROUND: During the Italian Phase-2 of the coronavirus pandemic, it was possible to restart elective surgeries. Because hospitals were still burdened with coronavirus disease 2019 (COVID-19) patients, it was focal to design a separate "clean path" for the surgical candidates and determine the possible effects of major surgery on previously infected patients. METHODS: From May to July 2020 (postpandemic peak), 259 consecutive patients were scheduled for elective cardiac surgery in three different centers. Our original roadmap with four screening steps included: a short item questionnaire (STEP-1), nasopharyngeal swab (NP) (STEP-2), computed tomography (CT)-scan using COVID-19 reporting and data system (CO-RADS) scoring (STEP-3), and final NP swab before discharge (STEP-4). RESULTS: Two patients (0.8%) resulted positive at STEP-2: one patient was discharged home for quarantine, the other performed a CT-scan (CO-RADS: <2), and underwent surgery for unstable angina. Chest-CT was positive in 6.3% (15/237) with mean CO-RADS of 2.93 ± 0.8. Mild-moderate lung inflammation (CO-RADS: 2-4) did not delay surgery. Perioperative mortality was 1.15% (3/259), and cumulative incidence of pulmonary complications was 14.6%. At multivariable analysis, only age and cardiopulmonary bypass (CPB) time were independently related to pulmonary complications composite outcome (age >75 years: odds ratio [OR]: 2.6; 95% confidence interval [CI]: 1.25-5.57; p = 0.011; CPB >90 min. OR: 4.3; 95% CI: 1.84-10.16; p = 0.001). At 30 days, no periprocedural contagion and rehospitalization for COVID-19 infections were reported. CONCLUSIONS: Our structured roadmap supports the safe restarting of an elective cardiac surgery list after a peak of a still ongoing COVID-19 pandemic in an epicenter area. Mild to moderate CT residuals of coronavirus pneumonia do not justify elective cardiac surgery procrastination.


Assuntos
COVID-19 , Procedimentos Cirúrgicos Cardíacos , Idoso , Humanos , Itália/epidemiologia , Pandemias , SARS-CoV-2
4.
Heart Surg Forum ; 23(3): E343-E349, 2020 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-32524971

RESUMO

BACKGROUND: Out-of-center extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) implantation for the treatment of acute cardiorespiratory failure with subsequent transport to a tertiary care center has been introduced successfully into the medical practice. However, due to the very specific and resource intensive nature of this therapeutic concept, it seems important to generate algorithms for adequate patient selection. The aim of our study was to analyze the impact of patients' gender on early clinical outcome in this specific therapeutic scenario. METHODS: Ninety-seven consecutive patients treated by out-of-center ECMO/ECLS implantation and subsequent transport and treatment in our tertiary care cardiovascular center within the Hallesche Extracorporeal Life Support Program (HELP) retrospectively were analyzed, regarding the impact of patients' gender on early clinical outcome. RESULTS: Mechanical circulatory support successfully was weaned in two-thirds of the male patients. This result was achieved in only one-third of the female patients (59.4% in male vs. 33.3% in female, P = .0267). Overall survival significantly was higher in the male group (62.5% in male versus 30.3% in female, P = .0052). In uni- and multivariate logistic regression analysis, female gender was an independent predictor of in-hospital mortality (uni: OR:3.833, CI:1.597-9.745, P = .0034; multi: OR:3.477, CI:1.146-11.494, P = .0322). Worse outcome also was associated with following independent predictors, age, SOFA score, lactate and ventilation time pre-ECMO/ECLS implantation. CONCLUSION: The current study demonstrates a worse early survival for women, following emergent out-of- center ECMO/ECLS implantation and subsequent transport and treatment in our tertiary care cardiovascular center. Gender should be included in patient selection algorithms while basic research approaches are needed to better understand the mechanisms underlying these gender- specific outcome disparities.


Assuntos
Circulação Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/terapia , Medição de Risco/métodos , Adulto , Idoso , Feminino , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Distribuição por Sexo , Fatores Sexuais , Taxa de Sobrevida/tendências
5.
Catheter Cardiovasc Interv ; 94(5): 755-763, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30790414

RESUMO

OBJECTIVES: To identify prevalence/impact of previous implantation of cardiac electronic devices (CEDs), such as cardioverter defibrillator (ICD) and cardiac resynchronization (CRT), in a group of MitraClip (MC) candidates with LVEF < 30%. BACKGROUND: MC therapy is nowadays often considered in patients with depressed left ventricular ejection fraction (LVEF%) and symptomatic severe secondary MR. METHODS: Data from the German Transcatheter Mitral Valve Interventions (TRAMIs) registry were analyzed. Patients with pre-procedural LVEF <30% were selected and divided according to the presence of CEDs. Pre-procedural, peri-procedural, and 1-year follow-up data were analyzed. RESULTS: Out of 689 MC patients, 235 had LVEF<30%. Of these, 23% (54/235) had CRT, 36.6% (86/235) ICD, and 40.4% (95/235) had no CEDs. Risk profile was similar (median STS score CRT 6.0 (IQR: 3.0-12.0); ICD 7.0 (IQR: 4.0-12.0); No-CED 6.5 (IQR: 2.0-10.0); p = 0.8). No procedural mortality was observed and hospital mortality was 5.6% in CRT, 2.3% in ICD, and 3.2% in No-CED (p = 0.5). At discharge, severe MV regurgitation was reported in 3.8% of CRT, 3.7% of ICD, and 1.1% of No-CED (p = 0.9). One year estimated survival (CRT 75.7%; ICD 75.8%; No-CED 78%; p = 0.94) and freedom from MACCE (CRT 73.6%; ICD 75.8%; No-CED 74.5%; p = 0.88) were similar. CONCLUSIONS: A third of patients have been already submitted to CEDs implantation at time of referral for MC therapy and 40% of those with severely depressed LVEF% arrive to MC therapy before ICD/CRT implantation. The presence of CED does not impair acute MC therapy success. Mid-term follow-up outcomes are similar in patients with and without CEDs.


Assuntos
Cateterismo Cardíaco , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
6.
Heart Vessels ; 34(12): 1969-1975, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31134380

RESUMO

The objectives of the study were to evaluate the impact of aortic angulation (AA) on success of transcatheter aortic valve replacement (TAVR) with a new generation self-expandable prosthesis (Medtronic Evolut R®). Specific anatomical conditions, such as for example the presence of a horizontal aorta with elevated AA, have seemed to pose a significant challenge for the correct positioning and consequent functioning of self-expandable TAVR prostheses. We assessed 146 patients treated with Evolut R. AA was measured at computed tomography and two groups were identified using as cutoff the mean AA value. Acute outcomes were collected and compared. AA mean value was 49.6 ± 9.4° (AA ≥ 50°: 76 and AA < 50°: 70 patients). Risk profile (Logistic euroSCORE: AA ≥ 50°: 15.7; 75% IQR: 11.1-22.1 vs. AA < 50°: 14.7; 75% IQR: 10.7-24.0; p = 0.8) was equivalent. Perioperative results were similar: valve resheathing (AA ≥ 50°: 21.0% vs. AA < 50°: 24.2%; p = 0.6), recapturing (AA ≥ 50°: 19.7% vs. AA < 50°: 25.7%; p = 0.3), fluoroscopy time (AA ≥ 50°: 11.1 IQR: 8.6-17.0 min. vs. AA < 50°: 11.0 IQR: 8.0-15.7 min.; p = 0.9), and contrast agent use (AA ≥ 50°: 99.0 ± 41.8 ml. vs. AA < 50°: 104.2 ± 38.5 ml.; p = 0.4). At discharge, moderate paravalvular leak was present in 8/76 (10.5%) of the AA ≥ 50° and 6/70 (8.6%) of the AA < 50° (p = 0.7) patients. Severe paravalvular leak, implantation of a second valve, and/or conversion to surgery did not occur. Early safety (AA ≥ 50°: 7.8% vs. AA < 50°: 5.7%; p = 0.6) was similar in the two groups. AA did not affect procedural outcomes and valve performance of the Evolut R prosthesis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Heart Surg Forum ; 22(2): E134-E139, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-31013224

RESUMO

BACKGROUND: We present our initial institutional experience with transaortic (TAo) transcatheter aortic valve implantation (TAVI) using a self-expanding aortic bioprosthesis. METHODS: A total of 106 patients underwent TAo TAVI with Medtronic CoreValve through a small partial upper sternotomy. We focus our analysis on the overall perioperative results, procedural learning curve (first 30 patients), and midterm follow-up outcomes. RESULTS: VARC-2 device success was achieved in 95 patients (89%), and there were no intraoperative deaths. Nine patients (8.4%) required a second valve and conversion to standard surgery was required in 2 patients (1.8%). The final aortic insufficiency was grade 0 in 65 patients (62%) and grade 1 in 39 (37%). Although patients treated in the TAo TAVI learning phase required a significantly longer radiation time and contrast agent use, device success (93.4% versus 88.2%, P = .7) and prostheses hemodynamics were similar. All-cause mortality at 30 days was 12% (13/106). At a median follow-up of 392 days (IQR: 216-494 days) estimated overall 1-year survival was 72%. No significant differences were reported in terms of 30-day and 1-year observed mortality, and estimated 1-year survival in the learning and later phase of TAo TAVI. CONCLUSION: TAo TAVI can be performed safely even in the very early phase of the learning curve. Although satisfactory results can be achieved from the beginning, a significant reduction in contrast agent use and radiological exposure are expected as the technique is mastered. Good hemodynamics have been documented and should be further improved with modifications achieved in the TAVI self-expandable valves technology.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Feminino , Alemanha , Humanos , Masculino , Esternotomia , Substituição da Valva Aórtica Transcateter/mortalidade
8.
Pacing Clin Electrophysiol ; 41(2): 128-135, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29222869

RESUMO

OBJECTIVES: The study aim is to present the long-term performance of a new generation implantable cardioverter defibrillator (ICD) electrode with floating atrial dipole (Linox S DX, Biotronik, Berlin, Germany). BACKGROUND: The single ICD electrode with a floating dipole in the atrial chamber was introduced about 15 years ago to overcome risk of inappropriate shock. METHODS: After implantation, internal electrocardiogram data were prospectively collected via telemonitoring (Home Monitoring, Biotronik). RESULTS: A total of 93 patients (81.5% male, 18.5% female; 58.9 ± 12.3 years) were implanted with a single-chamber ICD using the Linox S DX. Patients were followed up for a median of 693 days (33-2,460 days). At time of implantation average p-wave value was 3.5 ± 1.7 mV and remained stable throughout follow-up with an average value of 3.7 ± 1 mV (P = 0.2). A total of 460 arrhythmic episodes were recorded and 185 (40.2%) were incorrectly stratified by the device software. Seven patients (7.5%) experienced inappropriate ICD therapy. In three patients, VT episodes were not detected and remained untreated. CONCLUSIONS: Although the Linox S DX lead presents a satisfactory long-term stability of the atrial sensing, many of the messages sent to the device during follow-up were incorrectly classified by the ICD software. As a result, inappropriate therapy occurred with a rate similar to that observed with dual-chamber ICDs, but some malignant arrhythmias remained undiagnosed and untreated while occurring. Results in larger prospective cohorts should be analyzed and software improvements of the device should be suggested to overcome these potential drawbacks.


Assuntos
Desfibriladores Implantáveis/tendências , Eletrodos Implantados , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Resultado do Tratamento
9.
Heart Vessels ; 33(2): 205-211, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28808788

RESUMO

Prediction of follow-up shock is crucial to stratify patients with dilated cardiomyopathy (DCM) requiring implantable cardioverter defibrillator (ICD). The objective of the article is to assess the predictive value of endo-myocardial biopsy (EMB) towards ICD shock and follow-up mortality. A series of patients with DCM scheduled for ICD implantation underwent EMB to further determine the genesis of DCM. Presence of fibrosis and inflammation was documented and related to outcomes. A total of 240 patients were referred for ICD as primary (56%) and secondary (44%) prophylaxis. EMB showed myocardial fibrosis in 55.4%, inflammation in 55.7%, and viral genomic material in 60%. Median follow-up was 39 months (1-209). Appropriate and inappropriate shocks occurred in 29.2 and 20.4%. At logistic regression, determinants of appropriate shock were ICD indication for secondary prophylaxis (direct relationship: p = 0.009, OR 3.4, CI 1.3-8.8) and presence of inflammation at EMB (inverse relationship: p = 0.04, OR 0.4, CI 0.1-0.9). Moreover, the sole determinant of inappropriate shock was age at implant (inverse relationship: p = 0.003, OR = 0.9, CI 0.90-0.98). Overall mean estimated survival was 168 months and 5-year survival was 83%. Degree of improvement in LVEF% was the sole determinant of follow-up mortality (inverse relationship p = 0.02; HR = 0.9; CI 0.88-0.99). Present selection criteria for ICDs implant rely mainly on LVEF% that lacks sensitivity and specificity. EMB can identify the substrate of increased or reduced life-threatening arrhythmias. Presence of inflammation is a positive prognostic factor for reduced arrhythmogenic risk, independently by the ICD implantation indication.


Assuntos
Biópsia/métodos , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Miocárdio/patologia , Choque Cardiogênico/etiologia , Cardiomiopatia Dilatada/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Taxa de Sobrevida/tendências
10.
Catheter Cardiovasc Interv ; 89(1): 135-142, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27739165

RESUMO

OBJECTIVES: We present our single center experience with the direct flow medical (DFM) prosthesis addressing the impact of native aortic valve (AV) calcification degree on outcomes. BACKGROUND: The DFM® has been introduced for transcatheter aortic valve implantation (TAVI). The valve has a nonmetallic and inflatable support structure. METHODS: Patients were divided in two groups according to preoperative cardiac computed tomography (CT): group I moderate calcification and group II heavy calcification of the total AV area. We evaluated 118 patients: 53 (45%) group I and 65 (55%) group II. RESULTS: Preoperative trans-AV gradient and calcification extension across the aortic unit were significantly higher in group II (P = 0.008 and P < 0.0001). CT perimeter derived annular diameter (group I 24.7 ± 2.1 mm vs. group II 24.8 ± 1.9; P = 0.6) and implanted prosthesis size (group I 26.1 ± 1.5 mm vs. group II 25.7 ± 1.5; P = 0.1) were similar. Hemodynamics were similar: mean gradient 16.1 ± 5.9 mm Hg (group I) vs. 17.3 ± 6.5 mm Hg (group II) (P = 0.3). Total aortic regurgitation (AR) was mild in 5.7% in group I and 20% in group II (P = 0.03). None developed moderate/severe AR. Heavy AV calcification was the sole independent determinant for mild regurgitation (P = 0.02; OR = 7; 95% CI: 1.2-37.6). Follow-up (289 days; 40-760 days) estimated survival was 88.1% (group I) and 93.8% (group II) (P = 0.3). CONCLUSIONS: Independent of AV calcification degree, adequate sizing and implantation can be achieved with the DFM®. Although higher burden of calcification increases the rate of mild AR, no patient developed moderate and severe AR. Short-term estimated survival was not influenced by calcification degree. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Bioprótese , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 89(3): 420-428, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27739170

RESUMO

OBJECTIVES: To analyze our single center experience with the Direct Flow Medical (DFM). BACKGROUND: The DFM has been recently introduced to the market and large real world experiences are lacking. METHODS: A total of 126 patients with severe aortic valve stenosis (AVS) were treated by the same team from March 2013 to May 2015. Device success and procedural safety were classified, according to valve academic research consortium (VARC) criteria, for the entire cohort, including patients treated in the early phases of our learning curve. RESULTS: Clinical and trans-thoracic echocardiography follow-up was performed (median duration 279 days; 36-761 days). Mean age was 80.9 ± 5.5 years and median logistic Euro-SCORE was 15.9 (5.5-84.2). Cardiovascular 30-day mortality was 4.8% (6/126), device success 89.6% (113/126), and early safety 85.7% (108/126). At discharge, no aortic regurgitation (AR) was present in 85.7% and mild AR in 14.3% of the patients. Estimated 1-year follow-up survival was 91%. At follow-up, no AR was present in 87.3%, mild AR in 10.9%, and moderate AR in 1.8%. Mean gradient of 15.1 ± 6.3 mm Hg and prosthesis effective orifice area of 1.6 ± 0.6 cm2 were reported. CONCLUSIONS: In this single center experience, the DFM valve showed satisfactory clinical and hemodynamic results. Short-term follow-up confirmed the consistent clinical results, with low rates of AR and acceptable trans-prosthetic gradients and prosthetic effective orifice area. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Ecocardiografia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Curva de Aprendizado , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 87(3): 500-7, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26013307

RESUMO

OBJECTIVES: We present our experience with an inflatable, non-metallic, fully retrievable, and repositionable transcatheter aortic valve [Direct Flow® Medical (DFM)] focusing on technical features adopted during implantation. BACKGROUND: Implantation techniques of new generation percutaneous aortic valves are still developing and with experience implementations are described. METHODS: The "low pressure" (initial valve inflation at 4 ATM, lower than the recommended 12 ATM) and the "alternate aortic curve" techniques (initial valve pulling either from the wire running on the side of the inner or from the one on the outer aortic curve) are part of our modified protocol for DFM® implantation. RESULTS: Forty-two consecutive patients underwent TAVI with DFM. The "low pressure" technique was used in all patients. In 27 (64.3%) patients the bulkiest calcifications were on the inner aortic curve side, and an inner curve technique was used to initiate valve pulling toward the annular hinge point. In the remaining 15 (35.7%) patients, an outer curve technique was used. Neither pull-through nor re-valving was reported. Valve performance showed mean gradient of 8.9 mm Hg. Mild paravalvular leak was reported in seven (16%) patients. No one experienced moderate or severe aortic insufficiency. Thirty-day mortality was 9.5% (4/42). CONCLUSION: The "low pressure technique" and the "alternate curve technique" guarantee an anatomy and patient tailored approach to achieve controlled and finely tuned valve seating.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Valvuloplastia com Balão , Calcinose/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Aortografia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pressão , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
13.
J Endovasc Ther ; 23(1): 172-81, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26496956

RESUMO

PURPOSE: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. METHODS: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. RESULTS: The bird-beak configuration with the greatest protrusion extension exhibited the maximum TAG device displacement (1.66 mm), while the lowest protrusion extension configuration led to the minimum amount of both displacement and rotation parameters (0.25 mm and 0.6°, respectively). A positive relationship was found between the infolding parameters and the flow circulating in the aorta and left subclavian artery. Similarly, TAG device displacement was positively and significantly (p<0.05) correlated with the pulse pressure for all bird-beak configurations and device sizes. However, no collapse was observed under chronic perfusion testing maintained for 30 days and pulse pressure of 100 mm Hg. CONCLUSION: These findings suggest that endograft infolding depends primarily on the amount of aortic pulsatility and flow rate and that physiological flows do not necessarily engender hemodynamic loads on the proximal bird-beak segment sufficient to cause TAG collapse. Hemodynamic variables may allow for identification of patients at high risk of endograft infolding and help guide preventive intervention to avert its occurrence.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Modelos Anatômicos , Modelos Cardiovasculares , Falha de Prótese , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aortografia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/fisiopatologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Desenho de Prótese , Fluxo Pulsátil , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
Artif Organs ; 40(4): 394-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26517844

RESUMO

Acute type A retrograde aortic dissection is characterized by a port of entry located in the descending aorta near the subclavian take-off, and is currently treated with surgery. Our experience with two patients who underwent a complicated postoperative course stimulated a review of the current literature and discussion of possible alternative strategies in light of recent advances in endovascular treatment.


Assuntos
Aneurisma da Aorta Torácica/terapia , Dissecção Aórtica/terapia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Adulto , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aortografia , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento
15.
J Heart Valve Dis ; 24(2): 169-72, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26204679

RESUMO

A case is reported of iatrogenic mitral valve chordal rupture occurring during transcatheter aortic valve implantation (TAVI) with an inflatable and repositionable valve (Direct Flow; Direct Flow Medical, Santa Rosa, CA, USA). The specific implantation technique requires initial valve advancement into the left ventricular cavity, valve inflation within the ventricular cavity, and a final finely tuned valve upward pulling through the left ventricular outflow tract until contact with the aortic annulus is achieved. During this phase of the procedure, entangling with the mitral subvalvular apparatus should be excluded, to avoid inadvertent tissue tearing and consequent mitral valve malfunction. The present patient underwent TAVI but then developed symptomatic severe mitral valve regurgitation resulting from chordal rupture. The condition was successfully treated percutaneously by implanting a Mitra-Clip.


Assuntos
Cordas Tendinosas/lesões , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/etiologia , Idoso de 80 Anos ou mais , Valva Aórtica , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Doença Iatrogênica , Complicações Intraoperatórias , Masculino , Ruptura
16.
Ann Vasc Surg ; 29(4): 841.e13-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25733217

RESUMO

Whenever some basic rules for endovascular aortic repair of type B aortic dissection are not followed, iatrogenic complications may develop. A 64-year-old gentleman was referred to our institution for revision of previous treatment of complex type B aortic dissection with 2 bare stents. At 3 months, the most proximal aortic bare stent had entered, via the proximal tear, the false lumen. Aortic expansion and dynamic obstruction at the level of the renal arteries had also developed. In a first step, we removed the proximal aortic bare stent surgically. Few days later, 2 covered endografts were implanted into the true lumen of the thoracic aorta with clinical success. The rationale for using endovascular treatment in patients with complicated type B aortic dissection is coverage of the entry tear with covered nonoversized endografts. Negative results are achieved whenever these very simple rules are not strictly followed.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Stents , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Aortografia/métodos , Prótese Vascular , Remoção de Dispositivo , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Artif Organs ; 39(6): 526-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25735566

RESUMO

Endoventricular thrombolytic procedure (ETP) has been used to treat continuous-flow left ventricle assist device (CF-LVAD) thrombosis. The study aims to investigate the occurrence of complications after ETP. Data were retrospectively reviewed and analyzed in a series of patients who underwent CF-LVAD followed by ETP. Since November 2010, 20 patients underwent HeartWare CF-LVAD implantation at our institute. Four patients (20%) developed pump thrombosis and underwent a total of nine ETPs with tissue plasminogen activator infused into the left ventricle. The mean age was 60.2 ± 9 years. ETP was performed via either the femoral (n = 6) or radial artery (n = 3). Five ETPs (55.5%) were complicated by left and right radial artery occlusion, two by groin hematomas, and one by femoral artery false aneurysm. ETP carries a strong risk of vascular access complications that, in CF-LVAD patients, may add to the already complex clinical profile and economic burden; thus, a less invasive treatment is advisable whenever required.


Assuntos
Fibrinolíticos/uso terapêutico , Coração Auxiliar/efeitos adversos , Terapia Trombolítica/métodos , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Idoso , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
18.
J Card Surg ; 29(5): 653-62, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25080972

RESUMO

Thoracic aortic diseases are life-threatening conditions causing significant mortality and morbidity despite advances in diagnostic and surgical treatments. Computational methods combined with imaging techniques provide quantitative information of disease progression, which may improve clinical treatments and therapeutic strategies for clinical practice. Since hemodynamic and wall mechanics play important roles in the natural history and progression of aortic diseases, we reviewed the potential application of computational modeling of the thoracic aorta. We placed emphasis on the clinical relevance of these techniques for the assessment of aortic dissection, thoracic aortic aneurysm, and aortic coarctation. Current clinical guidelines and treatment are also described.


Assuntos
Aorta Torácica , Doenças da Aorta/diagnóstico , Modelagem Computacional Específica para o Paciente , Dissecção Aórtica/diagnóstico , Aorta Torácica/fisiopatologia , Aneurisma Aórtico/diagnóstico , Coartação Aórtica/diagnóstico , Doenças da Aorta/fisiopatologia , Fenômenos Biomecânicos , Diagnóstico por Imagem , Progressão da Doença , Hemodinâmica , Humanos , Guias de Prática Clínica como Assunto
19.
J Thorac Dis ; 16(3): 1825-1835, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38617758

RESUMO

Background: Atrial fibrillation (AF) is a cardiac arrhythmia frequently documented in patients requiring implantable cardioverter defibrillators (ICDs) and/or cardiac resynchronization therapy with defibrillator (CRT-D). Patients with diagnosed AF at the point of ICD or CRT-D implantation may have an impaired follow-up outcome. Methods: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR). Results: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation. Conclusions: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.

20.
Catheter Cardiovasc Interv ; 82(4): E552-63, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23359543

RESUMO

OBJECTIVES: To summarize our single Institution experience with staged total percutaneous management of aorto-mitral pathology. BACKGROUND: Percutaneous treatment of aortic valve stenosis (AVS) and mitral valve regurgitation (MVR) has been recently proposed for patients at high surgical risk. METHODS: Data concerning consecutive patients undergoing percutaneous transcatheter AV implantation (TAVI) followed by MV repair with MitraClip® were prospectively collected and analyzed. RESULTS: From January 2010 to February 2012 a total of 254 patients were referred to undergo TAVI in our Institution. Seventeen (6.7%) had preoperative severe MVR that remained unchanged after TAVI. Due to exacerbation of symptoms 12 patients were subsequently submitted to MV repair with the MitraClip® device. Mean age was 79 years (72-86 years), median Ambler score was 30.1 (17.2-42.6) and EuroSCORE 22.3 (10.2-48.6). Procedural success rate was 100%. Postprocedural hospitalization was 7.1 ± 2.7 and 4.6 ± 0.9 days after TAVI and MV repair, respectively. Six months follow-up echocardiography confirms improvement in LV-EF (37.2 ± 9.9 vs. 43.5 ± 10.7, P < 0.0001). No patient presents MVR exceeding grade I(+) or prosthetic aortic insufficiency > I grade and all patients experienced an improvement in functional status. CONCLUSIONS: Percutaneous treatment of AVS and MVR is feasible and safe. A tailored approach should be considered to treat firstly the AVS and subsequently the MVR when severe MV dysfunction and symptoms persist. Short-term durability of this combined percutaneous approach seems encouraging and justifies the economical burden to treat patients that have no other option.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/terapia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores , Estudos de Viabilidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Tempo de Internação , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Estudos Prospectivos , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa