Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
BMC Public Health ; 24(1): 963, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580984

RESUMO

BACKGROUND: Migrants face several barriers when accessing care and tend to rely on emergency services to a greater extent than primary care. Comparing emergency department (ED) utilization by migrants and non-migrants can unveil inequalities affecting the migrant population and pave the way for public health strategies aimed at improving health outcomes. This systematic review aims to investigate differences in ED utilization between migrant and non-migrant populations to ultimately advance research on migrants' access to care and inform health policies addressing health inequalities. METHODS: A systematic literature search was conducted in March 2023 on the Pubmed, Scopus, and Web of Science databases. The included studies were limited to those relying on data collected from 2012 and written in English or Italian. Data extracted included information on the migrant population and the ED visit, the differences in ED utilization between migrants and non-migrants, and the challenges faced by migrants prior to, during, and after the ED visit. The findings of this systematic review are reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. RESULTS: After full-text review, 23 articles met the inclusion criteria. All but one adopted a quantitative methodology. Some studies reported a higher frequency of ED visits among migrants, while others a higher frequency among non-migrants. Migrants tend to leave the hospital against medical advice more frequently than the native population and present at the ED without consulting a general practitioner (GP). They are also less likely to access the ED via ambulance. Admissions for ambulatory care-sensitive conditions, namely health conditions for which adequate, timely, and effective outpatient care can prevent hospitalization, were higher for migrants, while still being significant for the non-migrant population. CONCLUSIONS: The comparison between migrants' and non-migrants' utilization of the ED did not suggest a clear pattern. There is no consensus on whether migrants access EDs more or less than non-migrants and on whether migrants are hospitalized at a higher or lower extent. However, migrants tend to access EDs for less urgent conditions, lack a referral from a GP and access the ED as walk-ins more frequently. Migrants are also discharged against medical advice more often compared to non-migrants. Findings of this systematic review suggest that migrants' access to care is hindered by language barriers, poor insurance coverage, lack of entitlement to a GP, and lack of knowledge of the local healthcare system.


Assuntos
Migrantes , Humanos , Atenção à Saúde , Serviço Hospitalar de Emergência , Saúde Pública , Barreiras de Comunicação , Acessibilidade aos Serviços de Saúde
2.
J Clin Monit Comput ; 38(1): 89-100, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37863862

RESUMO

PURPOSE: This systematic review of randomized-controlled trials (RCTs) with meta-analyses aimed to compare the effects on intraoperative arterial oxygen tension to inspired oxygen fraction ratio (PaO2/FiO2), exerted by positive end-expiratory pressure (PEEP) individualized trough electrical impedance tomography (EIT) or esophageal pressure (Pes) assessment (intervention) vs. PEEP not tailored on EIT or Pes (control), in patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach. METHODS: PUBMED®, EMBASE®, and Cochrane Controlled Clinical trials register were searched for observational studies and RCTs from inception to the end of August 2022. Inclusion criteria were: RCTs comparing PEEP titrated on EIT/Pes assessment vs. PEEP not individualized on EIT/Pes and reporting intraoperative PaO2/FiO2. Two authors independently extracted data from the enrolled investigations. Data are reported as mean difference and 95% confidence interval (CI). RESULTS: Six RCTs were included for a total of 240 patients undergoing general anesthesia for surgery, of whom 117 subjects in the intervention group and 123 subjects in the control group. The intraoperative mean PaO2/FiO2 was 69.6 (95%CI 32.-106.4 ) mmHg higher in the intervention group as compared with the control group with 81.4% between-study heterogeneity (p < 0.01). However, at meta-regression, the between-study heterogeneity diminished to 44.96% when data were moderated for body mass index (estimate 3.45, 95%CI 0.78-6.11, p = 0.011). CONCLUSIONS: In patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach, PEEP personalized by EIT or Pes allowed the achievement of a better intraoperative oxygenation compared to PEEP not individualized through EIT or Pes. PROSPERO REGISTRATION NUMBER: CRD 42021218306, 30/01/2023.


Assuntos
Respiração com Pressão Positiva , Tomografia Computadorizada por Raios X , Humanos , Impedância Elétrica , Ensaios Clínicos Controlados Aleatórios como Assunto , Respiração com Pressão Positiva/métodos , Oxigênio
3.
Matern Child Nutr ; : e13676, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38837325

RESUMO

Recommendations for the management of malnutrition among infants aged less than 6 months (<6 m) are based on limited evidence. This study aimed to describe the characteristics, treatment outcomes and outcome-associated factors among malnourished infants <6 m admitted at Médecins Sans Frontières (MSF) inpatient and ambulatory therapeutic feeding centres (ITFC and ATFC) in North-East Nigeria, 2019-2022. We conducted a descriptive analysis of the cohorts and logistic regression to measure the association between two selected outcomes-inpatient mortality and defaulting from the ambulatory programme-and possible factors associated. In total, 940 infants <6 m were admitted at ITFC. Most of them presented severe acute malnutrition and comorbidities, with diarrhoea being the most frequent. On discharge, 13.3% (n = 125) of infants were cured, 72.9% (n = 684) stabilized (referred to ATFC), 6.5% (n = 61) left against medical advice and 4.2% (n = 39) died. The median length of hospital stay was 10 days [IQR 7-14]. A hospital stay shorter than 10 days was significantly associated with inpatient mortality (aOR = 12.51, 95% confidence interval [CI] = 3.72-42.11, p ≤ 0.01). Among 561 infants followed up at the ATFC, only 2.8% reported comorbidities. On discharge, 80.9% (n = 429) were cured, 16.2% (n = 86) defaulted and 1.1% (n = 6) died. Male sex (aOR = 1.94, 95% CI = 1.15-3.27, p = 0.01), internally displaced status (aOR = 1.70, 95% CI = 1.05-2.79, p = 0.03) and <-3 WLZ (aOR = 1.95, 95% CI = 1.05-3.63, p = 0.03) were significantly associated with programme defaulting. Stabilization and recovery rates among malnourished infants <6 m in the studied project align with acceptable standards in this humanitarian setting. Notable defaulting rates from outpatient care should be further explored.

4.
Int J Equity Health ; 22(1): 135, 2023 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-37481546

RESUMO

BACKGROUND: Disasters have an unequal impact on the population because of differences in conditions of vulnerability, exposure, and capacity. Migrants and women are among the groups that are at greater risk for and disproportionately affected by disasters. However, despite the large body of evidence that analyzes their vulnerability separately, disaster research that targets migrant women is scant. The aim of this scoping review was to analyze the published scientific literature concerning the vulnerability of migrant women and the consequent negative impact they experience during disasters. METHODS: A literature search was conducted on December 15th, 2021 on Pubmed, Scopus, and Web of Science databases. No time filter was applied to the search. Information regarding the article's main characteristics and design, migrant women and their migration experience, as well as about the type of disaster was collected. The factors responsible for the vulnerability of migrant women and the negative outcomes experienced during a disaster were extracted and inductively clustered in main themes reflecting several vulnerability pathways. The review followed the Joanna Briggs Institute methodology for scoping reviews and relied on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). RESULTS: After full text review, 14 articles met the inclusion criteria. All of them adopted a qualitative methodology and focused on COVID-19. The pandemic negatively affected migrant women, by triggering numerous drivers that increased their level of exposure and vulnerability. Overall, six vulnerability factors have been identified: legal status, poverty conditions, pre-existing health conditions, limited agency, gender inequality and language and cultural barriers. These resulted in nine impacts: worsening of mental health status, poor access to care, worsening of physical health conditions, fraud, exacerbation of poverty, gender-based violence, jeopardization of educational path, and unfulfillment of their religious needs. CONCLUSIONS: This review provided an analysis of the vulnerability factors of migrant women and the pathways leading to negative outcomes during a disaster. Overall, the COVID-19 pandemic demonstrated that health equity is a goal that is still far to reach. The post-pandemic era should constitute the momentum for thoroughly addressing the social determinants of health that systematically marginalize the most vulnerable groups.


Assuntos
COVID-19 , Desastres , Migrantes , Humanos , Feminino , Pandemias , Bases de Dados Factuais
5.
J Med Internet Res ; 25: e46639, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37902810

RESUMO

Electronic simulation (e-simulation)-particularly scenario-based e-simulation (SBES)-is an increasingly used, promising educational strategy for global health education that can address gaps in training access, effectiveness, and cost. However, there is little guidance for educators on how to develop an SBES, and guidance is lacking outside the clinical context. Moreover, literature on medical education rarely uses the theoretical basis for e-simulation design and development, including for SBES. Hence, we aim to differentiate and describe the concept, design elements, and theoretical basis of SBES with examples from different topics in global health. In addition to enhancing the understanding of the potential of SBES for global health education, this manuscript also provides practical recommendations for global health educators in designing and developing SBESs based on the existing literature and authors' experiences. Overall, this manuscript will be useful for global health educators as well as other medical educators seeking to develop an SBES for similar skill sets.


Assuntos
Educação Médica , Saúde Global , Humanos , Competência Clínica , Educação em Saúde , Simulação por Computador
6.
Int J Mol Sci ; 24(19)2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37834361

RESUMO

Circulating extracellular vesicles (EVs) may play a pathophysiological role in the onset of complications of subarachnoid hemorrhage (SAH), potentially contributing to the development of vasospasm (VP). In this study, we aimed to characterize circulating EVs in SAH patients and examine their effects on endothelial and smooth muscle cells (SMCs). In a total of 18 SAH patients, 10 with VP (VP), 8 without VP (NVP), and 5 healthy controls (HC), clinical variables were recorded at different time points. EVs isolated from plasma samples were characterized and used to stimulate human vascular endothelial cells (HUVECs) and SMCs. We found that EVs from SAH patients expressed markers of T-lymphocytes and platelets and had a larger size and a higher concentration compared to those from HC. Moreover, EVs from VP patients reduced cell viability and mitochondrial membrane potential in HUVECs and increased oxidants and nitric oxide (NO) release. Furthermore, EVs from SAH patients increased intracellular calcium levels in SMCs. Altogether, our findings reveal an altered pattern of circulating EVs in SAH patients, suggesting their pathogenic role in promoting endothelial damage and enhancing smooth muscle reactivity. These results have significant implications for the use of EVs as potential diagnostic/prognostic markers and therapeutic tools in SAH management.


Assuntos
Vesículas Extracelulares , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Hemorragia Subaracnóidea/complicações , Células Endoteliais/metabolismo , Vesículas Extracelulares/metabolismo , Plaquetas/metabolismo , Vasoespasmo Intracraniano/metabolismo
7.
Matern Child Nutr ; 19(1): e13440, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36222214

RESUMO

In 1998, the World Health Organisation (WHO) published general guidelines proposing essential measures to achieve relactation. Yet, increased knowledge about the practical set-up of relactation support interventions in different contexts is needed, especially in humanitarian settings, where nonbreastfed infants are particularly at risk. This study aimed to compile and assess the characteristics, outcomes and factors influencing the implementation of relactation support interventions reported since the latest WHO recommendations. We conducted a systematic review following Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines, undertaking a search from Medline, Embase, PubMed Central, Web of Science, Global Health and CINAHL electronic databases. Studies published in English and Spanish, reporting characteristics and outcomes of relactation support provided to non-(breastfeeding) BF mothers with infants aged less than 6 months were included. Data were analysed by narrative synthesis and the Johanna Briggs Institute Critical Appraisal Tools were used for quality assessment. Overall, 16 studies met the inclusion criteria. Most were observational and conducted in middle-income countries, only one focused on humanitarian settings. Studies reported inpatient and community-based interventions, which generally followed WHO recommendations for relactation. In 13 out of 16 studies, over 80% of mothers restarted BF after receiving relactation support. Enabling factors included younger infant age, shorter lactation gap, mother's strong motivation, family support, and continuous skilled support. Although current literature suggests that intensive relactation support can contribute to re-establish BF, its application and effectiveness in humanitarian settings remain uncertain. Further research is needed to explore the effectiveness, feasibility and acceptability of different approaches to relactation support, especially in humanitarian settings.


Assuntos
Aleitamento Materno , Lactação , Lactente , Feminino , Humanos , Mães
8.
Sensors (Basel) ; 22(21)2022 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-36365817

RESUMO

The number of older people needing healthcare is a growing global phenomenon. The assistance in long-term care comprises a complex of medical, nursing, rehabilitation, and social assistance services. The cost is substantial, but technology can help reduce spending by ensuring efficient health services and improving the quality of life. Advances in artificial intelligence, wireless communication systems, and nanotechnology allow the creation of intelligent home care systems avoiding hospitalization with evident cost containment. They are capable of ensuring functions of recognition of activities, monitoring of vital functions, and tracking. However, it is essential to also have information on location in order to be able to promptly intervene in case of unforeseen events or assist people in carrying out activities in order to avoid incorrect behavior. In addition, the automatic detection of physical activities performed by human subjects is identified as human activity recognition (HAR). This work presents an overview of the positioning system as part of an integrated HAR system. Lastly, this study contains each technology's concepts, features, accuracy, advantages, and limitations. With this work, we want to highlight the relationship between HAR and the indoor positioning system (IPS), which is poorly documented in the literature.


Assuntos
Inteligência Artificial , Qualidade de Vida , Humanos , Idoso , Atividades Humanas , Tecnologia sem Fio , Atenção à Saúde
9.
J Clin Monit Comput ; 36(4): 1193-1203, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34494204

RESUMO

PURPOSE: A number of studies performed in the operating room evaluated the hemodynamic effects of the fluid challenge (FC), solely considering the effect before and after the infusion. Few studies have investigated the pharmacodynamic effect of the FC on hemodynamic flow and pressure variables. We designed this trial aiming at describing the pharmacodynamic profile of two different FC infusion times, of a fixed dose of 4 ml kg-1. METHODS: Forty-nine elective neurosurgical patients received two consecutive FCs of 4 ml kg-1 of crystalloids in 10 (FC10) or 20 (FC20) minutes, in a random order. Fluid responsiveness was defined as stroke volume index increase ≥ 10%. We assessed the net area under the curve (AUC), the maximal percentage difference from baseline (dmax), time when the dmax was observed (tmax), change from baseline at 1-min (d1) and 5-min (d5) after FC end. RESULTS: After FC10 and FC20, 25 (51%) and 14 (29%) of 49 patients were classified as fluid responders (p = 0.001). With the exception of the AUCs of SAP and MAP, the AUCs of all the considered hemodynamic variables were comparable. The dmax and the tmax were overall comparable. In both groups, the hemodynamic effects on flow variables were dissipated within 5 min after FC end. CONCLUSIONS: The infusion time of FC administration affects fluid responsiveness, being higher for FC10 as compared to FC20. The effect on flow variables of either FCs fades 5 min after the end of infusion.


Assuntos
Hidratação , Hemodinâmica , Soluções Cristaloides , Humanos , Estudos Prospectivos , Volume Sistólico
10.
Crit Care ; 25(1): 189, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074314

RESUMO

BACKGROUND: Usefulness of noninvasive ventilation (NIV) in weaning patients with non-hypercapnic hypoxemic acute respiratory failure (hARF) is unclear. The study aims to assess in patients with non-hypercapnic hARF, the efficacy of NIV after early extubation, compared to standard weaning. METHODS: In this individual patient data meta-analysis, we searched EMBASE, Medline and Cochrane Central Register of Controlled Trials to identify potentially eligible randomized controlled trials published from database inception to October 2020. To be eligible, studies had to include patients treated with NIV after early extubation and compared to conventional weaning in adult non-hypercapnic hARF patients. Anonymized individual patient data from eligible studies were provided by study investigators. Using one-step and two-step meta-analysis models we tested the difference in total days spent on invasive ventilation. RESULTS: We screened 1605 records. Six studies were included in quantitative synthesis. Overall, 459 participants (mean [SD] age, 62 [15] years; 269 [59%] males) recovering from hARF were included in the analysis (233 in the intervention group and 226 controls). Participants receiving NIV had a shorter duration of invasive mechanical ventilation compared to control group (mean difference, - 3.43; 95% CI - 5.17 to - 1.69 days, p < 0.001), a shorter duration of total days spent on mechanical ventilation (mean difference, - 2.04; 95% CI - 3.82 to - 0.27 days, p = 0.024), a reduced risk of ventilatory associated pneumonia (odds ratio, 0.24; 95% CI 0.08 to 0.71, p = 0.014), a reduction of time spent in ICU (time ratio, 0.81; 95% CI 0.68 to 0.96, p = 0.015) and in-hospital (time ratio, 0.81; 95% CI 0.69 to 0.95, p = 0.010), with no difference in ICU mortality. CONCLUSIONS: Although primary studies are limited, using an individual patient data metanalysis approach, NIV after early extubation appears useful in reducing total days spent on invasive mechanical ventilation. TRIAL REGISTRATION: The protocol was registered to PROSPERO database on 12/06/2019 and available at PROSPERO website inserting the study code i.e., CRD42019133837.


Assuntos
Extubação/métodos , Hipóxia/terapia , Ventilação não Invasiva/normas , Fatores de Tempo , Humanos , Hipóxia/fisiopatologia , Ventilação não Invasiva/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Respiração Artificial/métodos , Desmame do Respirador/métodos
11.
Eur J Anaesthesiol ; 38(4): 422-431, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399372

RESUMO

BACKGROUND: The fluid challenge response in surgical patients can be predicted by functional haemodynamic tests. Two tests, the mini-fluid challenge (mini-FC) and end-expiratory occlusion test (EEOT), have been assessed in a few small single-centre studies with conflicting results. In general, functional haemodynamic tests have not performed reliably in predicting fluid responsiveness in patients undergoing laparotomy. OBJECTIVE: This trial is designed to address and compare the reliability of the EEOT and the mini-FC in predicting fluid responsiveness during laparotomy. DESIGN: Prospective, multicentre study. SETTING: Three university hospitals in Italy. PATIENTS: A total of 103 adults patients scheduled for elective laparotomy with invasive arterial monitoring. INTERVENTIONS: The study protocol evaluated the changes in the stroke volume index (SVI) 20 s (EEOT20) and 30 s (EEOT30) after an expiratory hold and after a mini-FC of 100 ml over 1 min. Fluid responsiveness required an increase in SVI at least 10% following 4 ml kg-1 of Ringer's solution fluid challenge infused over 10 min. MAIN OUTCOME MEASUREMENTS: Haemodynamic data, including SVI, were obtained from pulse contour analysis. The area under the receiver operating characteristic curves of the tests were compared with assess fluid responsiveness. RESULTS: Fluid challenge administration induced an increase in SVI at least 10% in 51.5% of patients. The rate of fluid responsiveness was comparable among the three participant centres (P = 0.10). The area under the receiver operating characteristic curves (95% CI) of the changes in SVI after mini-FC was 0.95 (0.88 to 0.98), sensitivity 98.0% (89.5 to 99.6) and specificity 86.8% (75.1 to 93.4) for a cut-off value of 4% of increase in SVI. This was higher than the SVI changes after EEOT20, 0.67 (0.57 to 0.76) and after EEOT30, 0.73 (0.63 to 0.81). CONCLUSION: In patients undergoing laparotomy the mini-FC reliably predicted fluid responsiveness with high-sensitivity and specificity. The EEOT showed poor discriminative value and cannot be recommended for assessment of fluid responsiveness in this surgical setting. TRIAL REGISTRATION: NCT03808753.


Assuntos
Hidratação , Salas Cirúrgicas , Adulto , Pressão Sanguínea , Hemodinâmica , Humanos , Itália , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Respiração Artificial , Volume Sistólico
12.
Eur J Anaesthesiol ; 38(1): 22-31, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32833857

RESUMO

BACKGROUND: Beat-to-beat stroke volume (SV) results from the interplay between left ventricular function and arterial load. Fluid challenge induces time-dependent responses in cardiac performance and peripheral vascular and capillary characteristics. OBJECTIVE: To assess whether analysis of the determinants of the haemodynamic response during fluid challenge can predict the final response at 10 and 30 min. DESIGN: Observational multicentric cohort study. SETTING: Three university ICUs. PATIENTS: 85 ICU patients with acute circulatory failure diagnosed within the first 48 h of admission. INTERVENTION(S): The fluid challenge consisted of 500 ml of Ringer's solution infused over 10 min. A SV index increase at least 10% indicated fluid responsiveness. MAIN OUTCOME MEASURES: The SV, pulse pressure variation (PPV), arterial elastance, the systolic-dicrotic pressure difference (SAP-Pdic) and cardiac cycle efficiency (CCE) were measured at baseline, 1, 2, 3, 4, 5, 10, 15 and 30 min after the start of the fluid challenge. All haemodynamic data were submitted to a univariable logistic regression model and a multivariable analysis was then performed using the significant variables given by univariable analysis. RESULTS: The multivariable model including baseline PPV, and the changes of arterial elastance at 1 min and of the CCE and SAP-Pdic at 5 min when compared with their baseline values, correctly classified 80.5% of responders and 90.7% of nonresponders at 10 min. For the response 30 min after starting the fluid challenge, the model, including the changes of PPV, CCE, SAP-Pdic at 5 min and of arterial elastance at 10 min compared with their baseline values, correctly identified 93.3% of responders and 91.4% of nonresponders. CONCLUSION: In a selection of mixed ICU patients, a statistical model based on a multivariable analysis of the changes of PPV, CCE, arterial elastance and SAP-Pdic, with respect to baseline values, reliably predicts both the early and the late response to a standardised fluid challenge. TRIAL REGISTRATION: ACTRN12617000076370.


Assuntos
Hidratação , Hemodinâmica , Pressão Sanguínea , Estudos de Coortes , Humanos , Estudos Prospectivos , Volume Sistólico
13.
Sensors (Basel) ; 21(15)2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34372207

RESUMO

Measuring the distance between two points has multiple uses. Position can be geometrically calculated from multiple measurements of the distance between reference points and moving sensors. Distance measurement can be done by measuring the time of flight of an ultrasonic signal traveling from an emitter to receiving sensors. However, this requires close synchronization between the emitter and the sensors. This synchronization is usually done using a radio or optical channel, which requires additional hardware and power to operate. On the other hand, for many applications of great interest, low-cost, small, and lightweight sensors with very small batteries are required. Here, an innovative technique to measure the distance between emitter and receiver by using ultrasonic signals in air is proposed. In fact, the amount of the signal attenuation in air depends on the frequency content of the signal itself. The attenuation level that the signal undergoes at different frequencies provides information on the distance between emitter and receiver without the need for any synchronization between them. A mathematical relationship here proposed allows for estimating the distance between emitter and receiver starting from the measurement of the frequency dependent attenuation along the traveled path. The level of attenuation in the air is measured online along the operation of the proposed technique. The simulations showed that the range accuracy increases with the decrease of the ultrasonic transducer diameter. In particular, with a diameter of 0.5 mm, an error of less than ± 2.7 cm (average value 1.1 cm) is reached along two plane sections of the typical room of the office considered (4 × 4 × 3 m3).

14.
Anesthesiology ; 133(1): 145-153, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32349074

RESUMO

BACKGROUND: Esophageal balloon calibration was proposed in acute respiratory failure patients to improve esophageal pressure assessment. In a clinical setting characterized by a high variability of abdominal load and intrathoracic pressure (i.e., pelvic robotic surgery), the authors hypothesized that esophageal balloon calibration could improve esophageal pressure measurements. Accordingly, the authors assessed the impact of esophageal balloon calibration compared to conventional uncalibrated approach during pelvic robotic surgery. METHODS: In 30 adult patients, scheduled for elective pelvic robotic surgery, calibrated end-expiratory and end-inspiratory esophageal pressure, and the associated respiratory variations were obtained at baseline, after pneumoperitoneum-Trendelenburg application, and with positive end-expiratory pressure (PEEP) administration and compared to uncalibrated values measured at 4-ml filling volume, as per manufacturer recommendation. Data are expressed as median and [25th, 75th percentile]. RESULTS: Ninety calibrations were successfully performed. Chest wall elastance worsened with pneumoperitoneum-Trendelenburg and PEEP (19.0 [15.5, 24.6] and 16.7 [11.4, 21.7] cm H2O/l) compared to baseline (8.8 [6.3, 9.8] cm H2O/l; P < 0.0001 for both comparisons). End-expiratory and end-inspiratory calibrated esophageal pressure progressively increased from baseline (3.7 [2.2, 6.0] and 7.7 [5.9, 10.2] cm H2O) to pneumoperitoneum-Trendelenburg (6.2 [3.8, 10.2] and 16.1 [13.1, 20.6] cm H2O; P = 0.014 and P < 0.001) and PEEP (8.8 [7.7, 15.6] and 18.9 [16.3, 22.0] cm H2O; P < 0.0001 vs. baseline for both comparison; P < 0.001 and P = 0.002 vs. pneumoperitoneum-Trendelenburg) and, at each study step, they were persistently lower than uncalibrated esophageal pressure (P < 0.0001 for all comparisons). Overall, difference among uncalibrated and calibrated esophageal pressure was 5.1 [3.8, 8.4] cm H2O at end-expiration and 3.8 [3.0, 6.3] cm H2O at end-inspiration. Uncalibrated esophageal pressure swing was always lower than calibrated one (P < 0.0001 for all comparisons) with a difference of -1.0 [-1.8, -0.4] cm H2O. CONCLUSIONS: In a clinical setting with variable chest wall mechanics, uncalibrated measurements substantially overestimated absolute values and underestimated respiratory variations of esophageal pressure. Calibration could substantially improve mechanical ventilation guided by esophageal pressure.


Assuntos
Esôfago/fisiologia , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Idoso , Algoritmos , Oclusão com Balão , Calibragem , Oscilação da Parede Torácica , Elasticidade , Feminino , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/cirurgia , Pneumoperitônio Artificial , Respiração com Pressão Positiva , Pressão , Testes de Função Respiratória , Procedimentos Cirúrgicos Robóticos/métodos
15.
Anesth Analg ; 130(3): 752-761, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31651455

RESUMO

BACKGROUND: In patients in the prone position, the reliability of pulse pressure variation and stroke volume variation (PPV and SVV) and the use of functional hemodynamic tests to predict fluid responsiveness have not previously been established. Perioperatively, in this setting, optimizing fluid management can be challenging, and fluid overload is associated with both intraoperative and postoperative complications. We designed this study to assess the sensitivity and specificity of baseline PPV and SVV, the tidal volume (VT) challenge (VTC) and the end-expiratory occlusion test (EEOT) in predicting fluid responsiveness during elective spinal surgery. METHODS: The study protocol was started during a period of intraoperative hemodynamic stability after prone positioning and before the administration of any vasopressor: (1) at baseline, the controlled ventilation was set at 6 mL/kg of predicted body weight (PBW) (T0); (2) patients underwent the first EEOT (EEOT6) by interrupting the mechanical ventilation for 30 seconds; (3) the ventilation was set again at 6 mL/kg PBW for 1 minute (T1); (4) the VTC was applied by increasing the VT up to 8 mL/kg PBW for 1 minute; (5) the ventilation was kept at 8 mL/kg PBW for 1 minute (T2); (6) a second EEOT (EEOT8) was performed; (7) the VT was reduced back to 6 mL/kg PBW for 1 minute (T3); (8) a fluid challenge of 250 mL of Ringer's solution was infused over 10 minutes. After each step, a complete set of hemodynamic measurements was recorded. RESULTS: Neither PPV and SVV values recorded at T3 nor the EEOT6 or the EEOT8 predicted fluid responsiveness. The change in PPV after VTC application predicted fluid responsiveness with an area under the curve of 0.96 (95% confidence interval, 0.87-1.00), showing a sensitivity of 95.2% and a specificity of 94.7%, using a cutoff increase of 12.2%. The change in SVV after VTC application predicted fluid responsiveness with an area under the curve 0.96 (95% confidence interval, 0.89-1.00) showing a sensitivity of 95.2% and a specificity of 94.7%, using a cutoff increase of 8.0%. A linear correlation between stroke volume index changes after fluid challenge administration and the changes in PPV and SVV after VTC application was observed (r = 0.71; P < .0001 and r = 0.68; P < .0001, respectively). CONCLUSIONS: In prone elective neurosurgical patients, the baseline values of PPV and SVV and the EEOT fail to predict fluid responsiveness, while the VTC is a very reliable functional hemodynamic test and could be helpful in guiding intraoperative fluid therapy.


Assuntos
Hidratação , Hemodinâmica , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos , Posicionamento do Paciente , Decúbito Ventral , Respiração Artificial , Mecânica Respiratória , Solução de Ringer/administração & dosagem , Coluna Vertebral/cirurgia , Idoso , Pressão Sanguínea , Tomada de Decisão Clínica , Feminino , Hidratação/efeitos adversos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Posicionamento do Paciente/efeitos adversos , Assistência Perioperatória , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Respiração Artificial/efeitos adversos , Solução de Ringer/efeitos adversos , Fatores de Risco , Volume Sistólico , Volume de Ventilação Pulmonar , Fatores de Tempo
17.
Sensors (Basel) ; 20(3)2020 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-32012789

RESUMO

The growing interest for indoor position-based applications and services, as well as ubiquitous computing and location aware information, have led to increasing efforts toward the development of positioning techniques. Many applications require accurate positioning or tracking of people and assets inside buildings, and some market sectors are waiting for such technologies for starting a fast growth. Ultrasonic systems have already been shown to possess the desired positioning accuracy and refresh rate. However, they still require accurate synchronization between ultrasound emitters and receivers to work properly. Usually, synchronization is carried out through radio frequency (RF) signals, adding system complexity and raising the cost. In this work, this limit is overcome by introducing a novel self-synchronizing indoor positioning technique. Ultrasonic signals travel from emitters placed at fixed reference positions to any number of mobile devices (MD). The travelled distance is computed from the time of flight (TOF), which requires in turn synchronism between emitter and receiver. It is shown that this synchronism can be indirectly estimated from the time difference of arrival (TDOA) of the ultrasonic signals. The obtained positioning information is private, in the sense that the positioning infrastructure is not aware of the number or identity of the MDs that use it. Computer simulations and experimental results obtained in a typical office room are provided.

18.
Sensors (Basel) ; 20(12)2020 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-32585908

RESUMO

Increasing efforts toward the development of positioning techniques testify the growing interest for indoor position-based applications and services. Many applications require accurate indoor positioning or tracking of people and assets, and some market sectors are starting a rapid growth of products based on these technologies. Ultrasonic systems have already been demonstrating their effectiveness and to possess the desired positioning accuracy and refresh rates. In this work, it is shown that a typical signal used in ultrasonic positioning systems to estimate the range between the target and reference points-namely, the linear chirp-due to the effects of acoustic diffraction, in some cases, undergoes a shape aberration, depending on the shape and size of the transducer and on the angle under which the transducer is seen by the receiver. In the presence of such signal shape aberrations, even one of the most robust ranging techniques, which is based on cross-correlation, provides results affected by a much greater error than expected. Numerical simulations are carried out for a typical ultrasonic chirp, ultrasonic emitter, and range technique based on cross-correlation and for a typical office room, obtained using the academic acoustic simulation software Field II. Spatial distributions of the ranging error are provided, clearly showing the favorable low error regions. The work demonstrates that particular attention must be paid to the design of the acoustic section of the ultrasonic positioning systems, considering both the shape and size of the ultrasonic emitters and the shape of the acoustic signal used.

19.
J Clin Monit Comput ; 34(6): 1223-1231, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31792760

RESUMO

Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated Pes (Pescal) was compared to uncalibrated one acquired at 4 ml-filling volume (PesV4), as per manufacturer recommendation. After a naso-gastric tube equipped with oesophageal balloon was correctly positioned in 21 adult patients undergoing invasive volume-controlled ventilation (VCV) for acute hypoxemic respiratory failure, the balloon was progressively inflated, applying a series of end-inspiratory and end-expiratory holds at each filling volume during VCV and PSV. Upon optimal balloon filling volume (Vbest) was identified, Pescal was computed by correcting the Pes measured at Vbest for the oesophageal wall pressure elicited at same filling volume. Finally, end-expiratory and end-inspiratory PesV4 were recorded too. A total of 42 calibrations, 21 per ventilatory mode, were performed. Vbest was 1.9 ± 1.6 ml in VCV and 1.7 ± 1.6 ml in PSV (p = 0.5217). PesV4 was overestimated compared to Pescal at end-expiration and end-inspiration (p <0.0001 for all comparisons) in both VCV (13.4 ± 3.4 cmH2O and 15.4 ± 3 cmH2O vs. 8.5 ± 2.9 cmH2O and 11.4 ± 3 cmH2O) and PSV (14.7 ± 4.2 cmH2O and 17 ± 3.9 cmH2O vs. 8.9 ± 3.4 cmH2O and 12.4 ± 3.9 cmH2O). In PSV, oesophageal balloon calibration is feasible and allows to obtain a reliable Pes assessment compared to uncalibrated approach.


Assuntos
Respiração com Pressão Positiva , Mecânica Respiratória , Adulto , Calibragem , Humanos , Estudo de Prova de Conceito , Respiração Artificial
20.
Epidemiol Prev ; 44(5-6 Suppl 1): 179-184, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33415961

RESUMO

Barbara Pacelli, a young Italian epidemiologist, passed away unexpectedly in September 2019. During her prolific professional life, she gave several scientific contributions to natural disaster epidemiology, particularly in relation to the medium and long-term health effects of earthquakes. In this opinion paper, we reflect on Barbara's legacy and outline potential actions that could arise from her work. Particularly, availability of electronic health records would enable a systematic and large-scale investigation into the long-term health effects of earthquakes in Italy, a country with high seismic risk. This effort would have high societal value as it would likely enable mitigation of substantial morbidity and mortality in areas affected by earthquakes. In this paper, we define scope, objectives, potential data sources, and analysis methods that could be used to systematically assess the chronic health effects of recent earthquakes in Italy. Keywords: earthquakes; chronic diseases; electronic health records; retrospective cohort; case crossover study.


Assuntos
Doença Crônica/epidemiologia , Terremotos , Estudos Cross-Over , Feminino , Humanos , Itália/epidemiologia , Morbidade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa