1.
Eur Radiol ; 32(2): 806-814, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34331118

RESUMO

OBJECTIVES: This study was designed to compare the detection of subtle lesions (calcification clusters or masses) when using the combination of digital breast tomosynthesis (DBT) and synthetic mammography (SM) with digital mammography (DM) alone or combined with DBT. METHODS: A set of 166 cases without cancer was acquired on a DBT mammography system. Realistic subtle calcification clusters and masses in the DM images and DBT planes were digitally inserted into 104 of the acquired cases. Three study arms were created: DM alone, DM with DBT and SM with DBT. Five mammographic readers located the centre of any lesion within the images that should be recalled for further investigation and graded their suspiciousness. A JAFROC figure of merit (FoM) and lesion detection fraction (LDF) were calculated for each study arm. The visibility of the lesions in the DBT images was compared with SM and DM images. RESULTS: For calcification clusters, there were no significant differences (p > 0.075) in FoM or LDF. For masses, the FoM and LDF were significantly improved in the arms using DBT compared to DM alone (p < 0.001). On average, both calcification clusters and masses were more visible on DBT than on DM and SM images. CONCLUSIONS: This study demonstrated that masses were detected better with DBT than with DM alone and there was no significant difference (p = 0.075) in LDF between DM&DBT and SM&DBT for calcifications clusters. Our results support previous studies that it may be acceptable to not acquire digital mammography alongside tomosynthesis for subtle calcification clusters and ill-defined masses. KEY POINTS: • The detection of masses was significantly better using DBT than with digital mammography alone. • The detection of calcification clusters was not significantly different between digital mammography and synthetic 2D images combined with tomosynthesis. • Our results support previous studies that it may be acceptable to not acquire digital mammography alongside tomosynthesis for subtle calcification clusters and ill-defined masses for the imaging technology used.


Assuntos
Neoplasias da Mama , Calcinose , Neoplasias , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Mamografia
2.
Radiology ; 290(3): 629-637, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30526360

RESUMO

Purpose To report the impact of changing from screen-film mammography to digital mammography (DM) in a large organized national screening program. Materials and Methods A retrospective analysis of prospectively collected annual screening data from 2009-2010 to 2015-2016 for the 80 facilities of the English National Health Service Breast Cancer Screening Program, together with estimates of DM usage for three time periods, enabled the effect of DM to be measured in a study of 11.3 million screening episodes in women aged 45-70 years (mean age, 59 years). Regression models were used to estimate percentage and absolute change in detection rates due to DM. Results The overall cancer detection rate was 14% greater with DM (P < .001). There were higher rates of detection of grade 1 and 2 invasive cancers (both ductal and lobular), but no change in the detection of grade 3 invasive cancers. The recall rate was almost unchanged by the introduction of DM. At prevalent (first) screening episodes for women aged 45-52 years, DM increased the overall detection rate by 19% (P < .001) and for incident screening episodes in women aged 53-70 years by 13% (P < .001). Conclusion The overall cancer detection rate was 14% greater with digital mammography with no change in recall rates and without confounding by changes in other factors. There was a substantially higher detection of grade 1 and grade 2 invasive cancers, including both ductal and lobular cancers, but no change in the detection of grade 3 invasive cancers. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by C.I. Lee and J.M. Lee in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Continuidade da Assistência ao Paciente/estatística & dados numéricos , Mamografia/métodos , Idoso , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Detecção Precoce de Câncer , Inglaterra/epidemiologia , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Gradação de Tumores , Invasividade Neoplásica , Estudos Retrospectivos , Medicina Estatal
3.
Eur Radiol ; 26(3): 874-83, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26105023

RESUMO

OBJECTIVE: To compare the performance of different types of detectors in breast cancer detection. METHODS: A mammography image set containing subtle malignant non-calcification lesions, biopsy-proven benign lesions, simulated malignant calcification clusters and normals was acquired using amorphous-selenium (a-Se) detectors. The images were adapted to simulate four types of detectors at the same radiation dose: digital radiography (DR) detectors with a-Se and caesium iodide (CsI) convertors, and computed radiography (CR) detectors with a powder phosphor (PIP) and a needle phosphor (NIP). Seven observers marked suspicious and benign lesions. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). The cancer detection fraction (CDF) was estimated for a representative image set from screening. RESULTS: No significant differences in the FoMs between the DR detectors were measured. For calcification clusters and non-calcification lesions, both CR detectors' FoMs were significantly lower than for DR detectors. The calcification cluster's FoM for CR NIP was significantly better than for CR PIP. The estimated CDFs with CR PIP and CR NIP detectors were up to 15% and 22% lower, respectively, than for DR detectors. CONCLUSION: Cancer detection is affected by detector type, and the use of CR in mammography should be reconsidered. KEY POINTS: The type of mammography detector can affect the cancer detection rates. CR detectors performed worse than DR detectors in mammography. Needle phosphor CR performed better than powder phosphor CR. Calcification clusters detection is more sensitive to detector type than other cancers.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/instrumentação , Idoso , Detecção Precoce de Câncer/instrumentação , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Mamografia/métodos , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Agulhas , Variações Dependentes do Observador , Curva ROC , Intensificação de Imagem Radiográfica/métodos
4.
AJR Am J Roentgenol ; 203(2): 387-93, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25055275

RESUMO

OBJECTIVE. The objective of our study was to investigate the effect of image processing on the detection of cancers in digital mammography images. MATERIALS AND METHODS. Two hundred seventy pairs of breast images (both breasts, one view) were collected from eight systems using Hologic amorphous selenium detectors: 80 image pairs showed breasts containing subtle malignant masses; 30 image pairs, biopsy-proven benign lesions; 80 image pairs, simulated calcification clusters; and 80 image pairs, no cancer (normal). The 270 image pairs were processed with three types of image processing: standard (full enhancement), low contrast (intermediate enhancement), and pseudo-film-screen (no enhancement). Seven experienced observers inspected the images, locating and rating regions they suspected to be cancer for likelihood of malignancy. The results were analyzed using a jackknife-alternative free-response receiver operating characteristic (JAFROC) analysis. RESULTS. The detection of calcification clusters was significantly affected by the type of image processing: The JAFROC figure of merit (FOM) decreased from 0.65 with standard image processing to 0.63 with low-contrast image processing (p = 0.04) and from 0.65 with standard image processing to 0.61 with film-screen image processing (p = 0.0005). The detection of noncalcification cancers was not significantly different among the image-processing types investigated (p > 0.40). CONCLUSION. These results suggest that image processing has a significant impact on the detection of calcification clusters in digital mammography. For the three image-processing versions and the system investigated, standard image processing was optimal for the detection of calcification clusters. The effect on cancer detection should be considered when selecting the type of image processing in the future.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Reino Unido
5.
Med Phys ; 39(6): 3202-13, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22755704

RESUMO

PURPOSE: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. METHODS: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. RESULTS: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. CONCLUSIONS: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.


Assuntos
Calcinose/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Neoplasias da Mama/complicações , Neoplasias da Mama/diagnóstico por imagem , Calcinose/complicações , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Controle de Qualidade , Curva ROC , Doses de Radiação
7.
Phys Med Biol ; 62(7): 2778-2794, 2017 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-28291738

RESUMO

A novel method has been developed for generating quasi-realistic voxel phantoms which simulate the compressed breast in mammography and digital breast tomosynthesis (DBT). The models are suitable for use in virtual clinical trials requiring realistic anatomy which use the multiple alternative forced choice (AFC) paradigm and patches from the complete breast image. The breast models are produced by extracting features of breast tissue components from DBT clinical images including skin, adipose and fibro-glandular tissue, blood vessels and Cooper's ligaments. A range of different breast models can then be generated by combining these components. Visual realism was validated using a receiver operating characteristic (ROC) study of patches from simulated images calculated using the breast models and from real patient images. Quantitative analysis was undertaken using fractal dimension and power spectrum analysis. The average areas under the ROC curves for 2D and DBT images were 0.51 ± 0.06 and 0.54 ± 0.09 demonstrating that simulated and real images were statistically indistinguishable by expert breast readers (7 observers); errors represented as one standard error of the mean. The average fractal dimensions (2D, DBT) for real and simulated images were (2.72 ± 0.01, 2.75 ± 0.01) and (2.77 ± 0.03, 2.82 ± 0.04) respectively; errors represented as one standard error of the mean. Excellent agreement was found between power spectrum curves of real and simulated images, with average ß values (2D, DBT) of (3.10 ± 0.17, 3.21 ± 0.11) and (3.01 ± 0.32, 3.19 ± 0.07) respectively; errors represented as one standard error of the mean. These results demonstrate that radiological images of these breast models realistically represent the complexity of real breast structures and can be used to simulate patches from mammograms and DBT images that are indistinguishable from patches from the corresponding real breast images. The method can generate about 500 radiological patches (~30 mm × 30 mm) per day for AFC experiments on a single workstation. This is the first study to quantitatively validate the realism of simulated radiological breast images using direct blinded comparison with real data via the ROC paradigm with expert breast readers.


Assuntos
Neoplasias da Mama/patologia , Mama/anatomia & histologia , Mamografia/métodos , Modelos Biológicos , Imagens de Fantasmas , Projetos de Pesquisa , Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Ensaios Clínicos como Assunto , Simulação por Computador , Feminino , Humanos , Mamografia/instrumentação , Curva ROC , Intensificação de Imagem Radiográfica/métodos
8.
Phys Med ; 32(4): 568-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27061872

RESUMO

PURPOSE: To investigate the relationship between image quality measurements and the clinical performance of digital mammographic systems. METHODS: Mammograms containing subtle malignant non-calcification lesions and simulated malignant calcification clusters were adapted to appear as if acquired by four types of detector. Observers searched for suspicious lesions and gave these a malignancy score. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). Images of a CDMAM contrast-detail phantom were adapted to appear as if acquired using the same four detectors as the clinical images. The resultant threshold gold thicknesses were compared to the FoMs using a linear regression model and an F-test was used to find if the gradient of the relationship was significantly non-zero. RESULTS: The detectors with the best image quality measurement also had the highest FoM values. The gradient of the inverse relationship between FoMs and threshold gold thickness for the 0.25mm diameter disk was significantly different from zero for calcification clusters (p=0.027), but not for non-calcification lesions (p=0.11). Systems performing just above the minimum image quality level set in the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis resulted in reduced cancer detection rates compared to systems performing at the achievable level. CONCLUSIONS: The clinical effectiveness of mammography for the task of detecting calcification clusters was found to be linked to image quality assessment using the CDMAM phantom. The European Guidelines should be reviewed as the current minimum image quality standards may be too low.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Calcinose/diagnóstico por imagem , Calcinose/metabolismo , Calcinose/patologia , Feminino , Guias como Assunto , Humanos , Mamografia/normas , Intensificação de Imagem Radiográfica/métodos
9.
Radiology ; 237(2): 444-9, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16244252

RESUMO

PURPOSE: To evaluate prospectively the recall and cancer detection rates with and without computer-aided detection (CAD) in the United Kingdom National Health Service Breast Screening Programme. MATERIALS AND METHODS: The study had appropriate ethics committee approval. Informed consent was not required; however, patients were informed that their mammograms might be used in research efforts, and all patients agreed to participate. Mammograms obtained in 6111 women (mean age, 58.4 years) undergoing routine screening every 3 years were analyzed with a CAD system. Mammograms were independently double read. Twelve readers participated. Readers recorded an initial evaluation, viewed the CAD prompts, and recorded a final evaluation. Recall to assessment was decided after arbitration. Sensitivities were calculated for single reading, single reading with CAD, and double reading, as a proportion of the total number of cancers detected by using double reading with CAD. RESULTS: A total of 62 cancers were detected in 61 women. CAD prompted 51 (84%) of 61 radiographically detected cancers. Of 12 cancers missed on single reading, nine were correctly prompted; however, seven prompts were overruled by the reader. Sensitivity of single reading was 90.2% (95% confidence interval [CI]: 83.0%, 95.0%), single reading with CAD was 91.5% (95% CI: 85.0%, 96.0%), and double reading without CAD was 98.4% (95% CI: 91.0%, 100%). Cancer detection rate was 1%. Recall to assessment rate was 6.1%, with an increase of 5.8% because of CAD. Average time required, per reader, to read a case was 25 seconds without CAD and 45 seconds with CAD. CONCLUSION: CAD increases sensitivity of single reading by 1.3%, whereas double reading increases sensitivity by 8.2%.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Computador , Mamografia/normas , Programas de Rastreamento/métodos , Adulto , Neoplasias da Mama/epidemiologia , Intervalos de Confiança , Feminino , Humanos , Pessoa de Meia-Idade , Programas Nacionais de Saúde , Estudos Prospectivos , Sensibilidade e Especificidade , Reino Unido/epidemiologia