Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Catheter Cardiovasc Interv ; 87(4): 735-41, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26616458

RESUMO

Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries.


Assuntos
Angioplastia com Balão , Aorta , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Vasos Coronários , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Aorta/diagnóstico por imagem , Aortografia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 87(2): 273-82, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26424295

RESUMO

OBJECTIVES AND BACKGROUND: Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity. METHODS: Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP. CDP was calculated as (ΔP)/(0.5 × ρ × APV(2)). The density of blood (ρ) was assumed to be 1.05 g/cm(3). The correlation of current diagnostic parameters (CFR, FFR, HSR, and HMR) with CDP was evaluated. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, corresponding to the clinically used cut-off values (FFR = 0.80 and CFR = 2.0). RESULTS: CDP correlated significantly with FFR (r = 0.81, P < 0.05) and had significant diagnostic efficiency (ROC-area under curve of 86%), specificity (72%) and sensitivity (85%) at FFR < 0.8. The corresponding cut-off value for CDP to detect FFR < 0.8 was at CDP>25.4. CDP also correlated significantly (r = 0.98, P < 0.05) with epicardial-specific parameter, HSR. CONCLUSIONS: CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under ROC curve = 86%) with FFR, the frequently used method of evaluating stenosis severity.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Área Sob a Curva , Angiografia Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
Catheter Cardiovasc Interv ; 83(3): 377-85, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23785016

RESUMO

OBJECTIVES AND BACKGROUND: Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV). The CDP is a nondimensional ratio, derived from fundamental fluid dynamic principles. We sought to evaluate the correlation of CDP with FFR, CFR, and hyperemic stenosis resistance (HSR: ratio of pressure drop to APV) in human subjects. METHODS: Twenty-seven patients with reversible perfusion defects based on SPECT were consented for the study before cardiac catheterization. Distal coronary pressure and APV were measured simultaneously for each coronary lesion using a Combowire(©) during cardiac catheterization. Reference diameter, minimal lumen diameter, and %AS were obtained by quantitative coronary angiography. Maximum hyperemia was induced by IV adenosine (140 µg/kg/min). CDP was calculated as, (Δp)/(0.5 × ρ × APV(2) ). The density of blood (ρ) was assumed to be 1.05 gm/cm(3) . RESULTS: The functional index, CDP, when correlated simultaneously with FFR and CFR, was found to have a significant correlation (r = 0.61; P < 0.05). Similarly a significant correlation was achieved when CDP was correlated with HSR (r = 0.91; P < 0.001). This is consistent with the definition of CDP, which is a functional parameter that includes both pressure and flow information. CONCLUSIONS: CDP, a nondimensional parameter combining simultaneous measurements of pressure drop and velocity data, can accurately define the severity of coronary stenoses and could prove advantageous clinically.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Adenosina/administração & dosagem , Administração Intravenosa , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Circulação Coronária , Estenose Coronária/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Ohio , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Vasodilatadores/administração & dosagem
4.
Heart Vessels ; 29(1): 97-109, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23624760

RESUMO

In this study, coronary diagnostic parameters, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to distal dynamic pressure), and lesion flow coefficient (LFC: ratio of % area stenosis (%AS) to the CDP at throat region), were evaluated to distinguish levels of %AS under varying contractility conditions, in the presence of microvascular disease (MVD). In 10 pigs, %AS and MVD were created using angioplasty balloons and 90-µm microspheres, respectively. Simultaneous measurements of pressure drop, left ventricular pressure (p), and velocity were obtained. Contractility was calculated as (dp/dt)max, categorized into low contractility <900 mmHg/s and high contractility >900 mmHg/s, and in each group, compared between %AS <50 and >50 using analysis of variance. In the presence of MVD, between the %AS <50 and >50 groups, values of CDP (71 ± 1.4 and 121 ± 1.3) and LFC (0.10 ± 0.04 and 0.19 ± 0.04) were significantly different (P < 0.05), under low-contractility conditions. A similar %AS trend was observed under high-contractility conditions (CDP: 18 ± 1.4 and 91 ± 1.4; LFC: 0.08 ± 0.04 and 0.25 ± 0.04). Under MVD conditions, similar to fractional flow reserve, CDP and LFC were not influenced by contractility.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Microcirculação , Contração Miocárdica , Função Ventricular Esquerda , Animais , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Modelos Animais de Doenças , Índice de Gravidade de Doença , Suínos , Pressão Ventricular
5.
Biomed Eng Online ; 7: 24, 2008 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-18752683

RESUMO

BACKGROUND: The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses. METHODS: Three models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (eta) was calculated as the ratio of pressure recovery coefficient and the area blockage. RESULTS: The mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (approximately 80%) area stenosis, which is between moderate (approximately 65%) and severe (approximately 90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 +/- 3.3 to 287 +/- 52, n = 3, p < 0.01) and mean eta decreased (0.54 +/- 0.04 to 0.37 +/- 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion. CONCLUSION: The wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.


Assuntos
Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Diagnóstico por Computador/métodos , Modelos Cardiovasculares , Pericárdio/fisiopatologia , Simulação por Computador , Hemorreologia/métodos , Humanos , Resistência Vascular
7.
J Invasive Cardiol ; 26(5): 188-95, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24791716

RESUMO

OBJECTIVES AND BACKGROUND: Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of intermediate stenosis. CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a non-dimensional index derived from fundamental fluid dynamic principles based on a combination of intracoronary pressure and flow, may improve the functional assessment of coronary lesion severity. METHODS: We performed a meta-analysis of seven studies, retrieved from MEDLINE and PubMed, comparing the results of FFR and CFR of the same lesions. Two studies reported functional measurements (pressure and flow) obtained in individual patients. Five studies reported two-dimensional plots of FFR vs. CFR. The FFR and CFR data were digitized and corresponding functional measurements were extracted using the reported mean values of hemodynamic data from each of the five studies. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, which corresponds to the clinically used cut-off values (FFR = 0.80, FFR = 0.75, and CFR = 2.0). RESULTS: CDP correlated significantly with FFR (r = 0.78; P<.001) and had significant diagnostic efficiency (area under the ROC curve = 89%), specificity (83% and 85%), and sensitivity (81% and 76%) at FFR <0.8 and FFR <0.75, respectively. The corresponding cut-off value for CDP to detect FFR <0.80 and FFR <0.75 was at CDP >27.1 and CDP >27.9, respectively. CONCLUSIONS: CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under the ROC curve = 89%) with FFR, the most frequently used method for evaluation of coronary stenosis severity.


Assuntos
Pressão Sanguínea/fisiologia , Circulação Coronária/fisiologia , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Índice de Gravidade de Doença
9.
J Invasive Cardiol ; 24(1): 6-12, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22210582

RESUMO

OBJECTIVES AND BACKGROUND: Decisions based on invasive functional diagnostic measurements are often made in the setting of fluctuating hemodynamic variables that may alter resting or hyperemic measurements. The purpose of this investigation is to analyze the effect of myocardial contractility (CY) on invasive functional parameters. We hypothesize that the pressure drop coefficient (CDPe; ratio of pressure drop to distal dynamic pressure) and fractional flow reserve (FFR; ratio of average pressures distal and proximal to a stenosis) are not affected by fluctuations in CY and can distinguish between different severities of epicardial stenosis. METHODS: Simultaneous measurements of distal coronary-arterial pressure and velocity were performed in 10 pigs using a dual-sensor tipped guidewire for heart rate (HR) <110 bpm and HR >110 bpm, in the presence of coronary lesions of <50% area stenosis (AS) and >50% AS. Variations in myocardial function and vascular resistance were induced by atrial pacing, papaverine and balloon obstruction, respectively. The maximum rate of rise of left ventricular pressure ([dp/dt]max) was the index of contractility. The contractile function of the heart was empirically defined as CY >900 mm Hg/sec (higher) and CY <900 mm Hg/sec (normal). RESULTS: For CY >900 mm Hg/sec, under AS <50% and AS >50%, the mean values of FFR (0.91 ± 0.02 and 0.78 ± 0.02), and CDPe (15.6 ± 5.3 and 70.7 ± 24.7) were significantly different (P<.05). Similarly, for CY <900 mm Hg/sec, under AS <50% and AS >50%, the mean values of FFR (0.83 ± 0.04 and 0.63 ± 0.04), and CDPe (43.8 ± 14.9 and 191.8 ± 61.4) were also significantly different (P<.05). CONCLUSIONS: Both FFR and CDPe could effectively distinguish between stenosis severity at normal and higher levels of myocardial contractility.


Assuntos
Pressão Sanguínea/fisiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Modelos Animais , Contração Miocárdica/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Coronária , Estenose Coronária/diagnóstico , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Índice de Gravidade de Doença , Suínos , Resistência Vascular/fisiologia
10.
J Invasive Cardiol ; 21(10): 511-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19805837

RESUMO

BACKGROUND: Simultaneously measured pressure and flow distal to coronary stenoses can be combined, in conjunction with anatomical measurements, to assess the status of both the epicardial and microvascular circulations. METHODS AND RESULTS: Assessments of coronary hemodynamics were performed using fundamental fluid dynamics principles. We hypothesized that the pressure-drop coefficient (CDPe; trans-stenotic pressure drop divided by the dynamic pressure in the distal vessel) correlates linearly with epicardial and microcirculatory resistances concurrently. In 14 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire in the setting of both normal and disrupted microcirculation, with the presence of epicardial coronary lesions of lt; 50% area stenosis (AS) and > 50% AS. The CDPe progressively increased from lesions of < 50% AS to > 50% AS and had a higher resolving power (45 +/- 22 to 193 +/- 140 in normal microcirculation; 248 +/- 137 to 351 +/- 140 in disrupted microcirculation) as compared to fractional flow reserve (FFR) and coronary flow reserve (CFR). Strong multiple linear correlation was observed for CDPe with combined FFR and CFR (r = 0.72; p < 0.0001). Further, the ratio of maximum pressure drop coefficient evaluated at the site of stenosis and its theoretical limiting value of minimum cross-sectional area was also able to distinguish different combinations of coronary artery diseases. CONCLUSIONS: The CDPe can be readily obtained during routine pressure and flow measurements during cardiac catheterization. It is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment.


Assuntos
Estenose Coronária/fisiopatologia , Hemodinâmica/fisiologia , Microvasos/fisiopatologia , Modelos Cardiovasculares , Fluxo Sanguíneo Regional/fisiologia , Angioplastia com Balão , Animais , Interpretação Estatística de Dados , Modelos Animais de Doenças , Determinação de Ponto Final , Microcirculação/fisiologia , Microesferas , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa