Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
1.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978963

RESUMO

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Humanos , Polegar , Ligamento Colateral Ulnar/diagnóstico por imagem , Ligamento Colateral Ulnar/lesões , Ligamentos Colaterais/lesões , Fenômenos Biomecânicos , Articulação Metacarpofalângica
2.
Artigo em Inglês | MEDLINE | ID: mdl-38942223

RESUMO

OBJECTIVE: Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum. METHODS: In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into three groups: fixation was either performed with 3 x 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 x 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 x 3.0 mm HCCSs in PA orientation and 1 x 3.0 mm HCCS in lateral orientation (LAT group). Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens. RESULTS: There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 ± 0.5 mm vs. 0.8 ± 0.6 mm; p = 0.987) or PA and LAT groups (0.8 ± 0.6 mm vs. 0.8 ± 0.3 mm; p = 0.966). LAT group showed the highest load-to-failure (548 ± 250 N) without reaching statistically significant difference to AP group (388 ± 173 N; p = 0.101). There was also no significant difference between AP and PA groups (388 ± 173 N vs. 422 ± 114 N; p = 0.649). CONCLUSIONS: Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in two planes - both the coronal and the sagittal plane - by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.

3.
Pediatr Emerg Care ; 40(1): 2-5, 2024 Jan 01.
Artigo em Alemão, Inglês | MEDLINE | ID: mdl-36898049

RESUMO

OBJECTIVES: Buckle fractures of the distal forearm are a common fracture entity in children treated conservatively. Diagnostics primarily include radiographs in 2 planes. Inadequate images may occur in the mostly very young patients. Therefore, additional lateral radiographs are often obtained to assess a possible angular tilt. The aim of this study is to investigate whether a strictly lateral x-ray image has an influence on fracture management. METHODS: Seventy-three children with buckle fractures of the distal forearm were included in this retrospective analysis. All cases were analyzed by quality of radiographs, necessity to obtain an additional lateral radiograph, and what influence on fracture management resulted. Follow-up was performed 2 to 4 weeks after immobilization. RESULTS: Thirty-five girls and 38 boys with a mean age of 7.16 years were included; 40 had fractured right and 33 had fractured left arms, respectively. Isolated distal radius fractures occurred in 48 cases, isolated distal ulna fractures in 6 cases, and both bones in 19 cases. Initial radiographic images were evaluated as inadequate in 25 cases. In each of those cases, an additional lateral image was obtained by fluoroscopy without resulting in an alternated fracture management protocol, which was chosen conservatively in each case and resulted in excellent clinical outcome at follow-up examination. CONCLUSIONS: Based on our results, the acquisition of additional lateral radiographs seems to be unnecessary in the diagnostic procedure of buckle fractures of the distal forearm, in case a possible palmar or dorsal angulation cannot be entirely assessed on the initial set of radiographs. An additional lateral image had no influence on fracture management, which was chosen conservatively in every case and led to excellent clinical results.Level of evidence: level III.


Assuntos
Fraturas Múltiplas , Fraturas do Rádio , Fraturas da Ulna , Masculino , Criança , Feminino , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/terapia , Antebraço , Estudos Retrospectivos , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/terapia , Punho
4.
Int Orthop ; 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39031202

RESUMO

PURPOSE: Searching for quick determinable biomarkers with high sensitivity and specificity is necessary to improve and optimise the early diagnosis of periprosthetic elbow infection (PEI). Therefore, this study's objective was to evaluate the diagnostic value of synovial fluid interleukin-6 (IL-6) levels for diagnosing PEI in total elbow arthroplasty. METHOD: Twelve prospective enrolled patients underwent total elbow arthroplasty revision surgery, during which synovial fluid was obtained. Between the initial implantation and the revision procedure were 33.5 ± 41 months (range, 2-144 months). Synovial fluid was collected for immediate IL-6 analysis parallel to the revision surgery. Furthermore, microbiological samples were obtained and analysed. Two groups were defined based on the microbiological results: non-infection and infection group. The ability of synovial fluid IL-6 analysis to predict infection status was explored using receiver operating characteristic curves and further statistical analysis. RESULTS: Synovial fluid IL-6 analysis had a good diagnostic accuracy of 83% for PEI with an area under the curve of 0,79 and an ideal cutoff value (determined using Youden's criterion) of 15244 pg/mL. DISCUSSION: This is the first study to clinically evaluate IL-6 as a diagnostical marker for periprosthetic joint infection (PJI) in total elbow arthroplasty. Our results suggest a good accuracy and high sensitivity for IL-6 to identify a PEI. The analysis of IL-6 can improve surgical decision-making regarding managing total elbow arthroplasty in terms of one- or two-staged revision. CONCLUSION: IL-6 can play an important role in the perioperative differentiation of infected and non-infected situations.

5.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329521

RESUMO

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Assuntos
Articulação do Cotovelo , Nervo Ulnar , Masculino , Adulto , Humanos , Feminino , Nervo Ulnar/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Cotovelo/inervação , Tomografia Computadorizada por Raios X
6.
Arch Orthop Trauma Surg ; 143(5): 2383-2393, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35482109

RESUMO

INTRODUCTION: Stiffness after elbow injuries can severely limit daily life. If adequate conservative treatment does not result in satisfactory improvement of elbow function, surgical intervention should be considered. Whether an open or arthroscopic procedure is preferable is still a topic of debate and a systematic review of functional outcomes is lacking. MATERIALS AND METHODS: We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and EMBASE, for studies published between 2013 and 2021. Primary objective was to compare open and arthroscopic arthrolysis' functional outcomes, respectively, especially ROM and MEPS, as well as the accompanied complications. The PRISMA guidelines were applied. RESULTS: 27 studies comprising 1666 patients were included. 1059 patients (63.6%) were treated with open arthrolysis, and 607 patients (36.4%) were treated with arthroscopic arthrolysis. The results presented indicate satisfactory outcomes in open and arthroscopic arthrolysis with regard to functional outcome parameters. Treatment success, defined as excellent or good results according to the Mayo Elbow Performance Score, among the patients treated with an open procedure was 88.8%; 6.3% required revision whereas 18.1% had complications without the need for revision surgery. Within the cohort of arthroscopically treated patients, treatment success was 91.8%. Revisions and complications without further surgical intervention were significantly less frequent than in the open cohort, at 1.6% and 9.1%, respectively. CONCLUSIONS: Both open and arthroscopic arthrolysis provide good to excellent functional outcomes. Since the number of complications and revision increases with the invasiveness of the treatment, an arthroscopic procedure might be favored if feasible by indication. The role of forearm rotation and the use of a hinged external fixator remains of interest. STUDY DESIGN: Level IV; Systematic review.


Assuntos
Articulação do Cotovelo , Artropatias , Procedimentos Ortopédicos , Humanos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Artropatias/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
7.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35635575

RESUMO

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Assuntos
Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Idoso , Parafusos Ósseos , Fraturas do Ombro/cirurgia , Úmero/cirurgia , Placas Ósseas , Cadáver , Fenômenos Biomecânicos
8.
Arch Orthop Trauma Surg ; 143(5): 2467-2474, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35579703

RESUMO

INTRODUCTION: In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS: Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS: In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION: A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Manguito Rotador/cirurgia , Fraturas do Ombro/cirurgia , Ombro , Úmero , Cadáver
9.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35731264

RESUMO

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Assuntos
Articulação do Cotovelo , Fraturas Cominutivas , Fraturas do Úmero , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/métodos , Úmero , Redução Aberta/métodos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
10.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35064826

RESUMO

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Cotovelo , Instabilidade Articular/cirurgia , Articulação do Cotovelo/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Cadáver , Suturas , Ligamentos Colaterais/cirurgia , Ligamentos Colaterais/lesões
11.
Arch Orthop Trauma Surg ; 143(10): 6243-6249, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37421514

RESUMO

PURPOSE: Postoperative soft tissue swelling is a significant factor influencing outcomes after elbow surgery. It can crucially affect important parameters such as postoperative mobilization, pain, and subsequently the range of motion (ROM) of the affected limb. Furthermore, lymphedema is considered a significant risk factor for numerous postoperative complications. Manual lymphatic drainage is nowadays part of the standardized post-treatment concept, basing on the concept of activating the lymphatic tissue to absorb stagnated fluid from the tissue into the lymphatic system. This prospective study aims to investigate the influence of technical device-assisted negative pressure therapy (NP) on early functional outcomes after elbow surgery. NP was therefore compared to manual lymphatic drainage (MLD). Is a technical device-based NP suitable for treatment of lymphedema after elbow surgery? METHODS: A total of 50 consecutive patients undergoing elbow surgery were enrolled. The patients were randomized into 2 groups. 25 participants per group were either treated by conventional MLD or NP. The primary outcome parameter was defined as the circumference of the affected limb in cm postoperative up to seven days postoperatively. The secondary outcome parameter was a subjective perception of pain (measured via visual analogue scale, VAS). All parameters were measured on each day of postoperative inpatient care. RESULTS AND CONCLUSION: NP showed an overall equivalent influence compared to MLD in reducing upper limb swelling after surgery. Moreover, the application of NP showed a significant decrease in overall pain perception compared to manual lymphatic drainage on days 2, 4 and 5 after surgery (p < 0.05). CONCLUSION: Our findings show that NP could be a useful supplementary device in clinical routine treating postoperative swelling after elbow surgery. Its application is easy, effective and comfortable for the patient. Especially due to the shortage of healthcare workers and physical therapists, there is a need for supportive measures which NP could be.


Assuntos
Linfedema , Drenagem Linfática Manual , Humanos , Drenagem Linfática Manual/efeitos adversos , Estudos Prospectivos , Cotovelo , Edema/etiologia , Edema/terapia , Linfedema/complicações , Dor , Resultado do Tratamento
12.
Arch Orthop Trauma Surg ; 143(7): 4229-4237, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36512058

RESUMO

INTRODUCTION: The aim of the present study was to develop a technical process to reproducibly generate terrible triad injuries (TTI) in fresh-frozen human cadaveric specimens, while leaving the skin intact. Such "pre-fractured" specimens, used for scientific analysis and for surgical education, might help to improve current treatment, which is complex and prone to complications. MATERIALS AND METHODS: To induce the desired fractures, a custom-made fracturing unit was used to apply an axial force on the extended cadaveric elbow specimens, with the forearm pronated and under valgus load. To simulate the valgus load, a pneumatic cylinder was developed to apply valgus stress to the joint by an additional force vector from the lateral side of the joint. RESULTS: The success rate of TTI induction was 92.3% (12/13). Of the 12 radial head fractures, 3 (25%) were classified Mason type II and 9 (75%) Mason type III. The coronoid fractures were grouped in tip subtype 2 (5 fractures, 41.7%), anteromedial facet (AMF) subtype 2 (4 fractures, 33.3%), AMF subtype 3 (1 fracture, 8.3%) and basal subtype 1 (2 fractures, 16.7%). CONCLUSIONS: The present study provides an instrument for successful and reproducible production of dislocation fracture patterns with their typical accompanying soft tissue lesions. The methodology might be applied on a broad basis to be able to perform biomechanical studies regarding primary stability of fixation concepts for TTI and to educate surgeons in a fairly realistic scenario with the surgical treatment of TTI.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo , Luxações Articulares , Fraturas do Rádio , Fraturas da Ulna , Humanos , Luxações Articulares/cirurgia , Fraturas do Rádio/cirurgia , Articulação do Cotovelo/cirurgia , Cadáver , Fraturas da Ulna/cirurgia
13.
Arch Orthop Trauma Surg ; 143(7): 4111-4116, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197491

RESUMO

PURPOSE: The optimal screw placement in arthroscopically assisted fixation of radial head fractures is still an issue and no guiding methods have been evaluated in the recent literature. The study hypothesis was that using a "reference k-wire" percutaneously inserted in and parallel to the radiocapitellar joint would enable to achieve a trajectory more parallel to the radial head articular surface as compared to a free-hand k-wire placement. METHODS: Arthroscopically assisted placement of a k-wire in the radial head was performed in seven fresh-frozen human cadaver specimens by three surgeons. Three different techniques were evaluated: freehand drilling (technique A), placement using a "reference" k-wire in the radiocapitellar joint as a reference without (technique B), and with the AO parallel k-wire guide (technique C). Radiographs from all procedures were obtained and the inclination angle "α" between the k-wire and the articular surface of the radial head was measured and compared among the techniques. RESULTS: Angles of 84 radiographs were obtained and showed a mean α angle of 30.1° ± 13° for technique A, 5.7° ± 4.5° for technique B, and 5.4° ± 3.7° for technique C. The angle α was significantly higher with technique A as compared to B (p < 0.0001) and C (p < 0.0001). There was no difference between methods B and C (n.s.). No difference was observed among the surgeons for all three methods (p = 0.66). CONCLUSION: With the use of an additional "reference" k-wire placed in the radiocapitellar joint, the guiding k-wire for screw drilling can be placed almost parallel to the radial head joint line with limited variability and a good reproducibility during arthroscopically assisted radial head fracture fixation. CLINICAL RELEVANCE: The here-presented method of an additional, percutaneous introduced "reference" k-wire is easily applicable and helpful to achieve parallel screw placement during arthroscopically assisted radial head fracture fixation. LEVEL OF EVIDENCE: IV, biomechanical cadaver study.


Assuntos
Articulação do Cotovelo , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Reprodutibilidade dos Testes , Parafusos Ósseos , Fios Ortopédicos , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Cotovelo/cirurgia , Cadáver
14.
Arch Orthop Trauma Surg ; 143(10): 6201-6208, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37341804

RESUMO

INTRODUCTION: The SARS-CoV-2 pandemic and its associated lockdowns had a profound effect on orthopedic trauma emergencies. This study aimed to investigate the patient volume and injury patterns at a level-one trauma center during the SARS-CoV-2 pandemic and compare them to the pre-pandemic conditions. MATERIALS AND METHODS: A retrospective chart review of all patients who presented to the orthopedic trauma emergency department of a level-one trauma center in Cologne, Germany within a 2 year period from March 16th, 2019 to March 15th, 2020 (pre-pandemic control) and from March 16th, 2020 and March 15th, 2021 (pandemic) was performed. The pandemic year was separated into three periods: (1) first lockdown, (2) between lockdowns and (3) second lockdown. The absolute numbers of patient presentations, the Manchester triage score (MTS) and the relative proportion of patients with structural organ injuries, fractures and dislocations, of polytraumatized patients, of hospital admissions, of subsequent emergency or semi-elective surgeries and of work-related accidents were evaluated in comparison to the pre-pandemic control. RESULTS: A total of 21,642 patient presentations were included in this study. Significantly less weekly orthopedic trauma emergency patient presentations were recorded during the pandemic (p < 0.01). The MTS was significantly lower during the first lockdown and between lockdowns (p < 0.01). The proportional incidence of overall structural organ injuries, fractures and dislocations, of upper limb fractures/dislocations, of hospital admissions and of patients requiring surgery was significantly increased during the pandemic (p ≤ 0.03). The proportional incidence of work-related injuries was significantly decreased during the pandemic (p < 0.01). CONCLUSIONS: Orthopedic trauma emergency presentations were reduced during the SARS-CoV-2 pandemic. Due to the reluctancy of patients to visit the emergency department during the pandemic, the proportions of relevant injuries in general and of upper limb injuries in particular as well as of patients requiring hospital admission and trauma-related surgery were significantly increased.


Assuntos
COVID-19 , Fraturas Ósseas , Luxações Articulares , Humanos , SARS-CoV-2 , Centros de Traumatologia , COVID-19/epidemiologia , Pandemias/prevenção & controle , Estudos Retrospectivos , Emergências , Controle de Doenças Transmissíveis , Serviço Hospitalar de Emergência , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Luxações Articulares/epidemiologia
15.
Arch Orthop Trauma Surg ; 143(8): 5027-5034, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37042984

RESUMO

INTRODUCTION: Nailing of the proximal humerus is an established method for the treatment of proximal humerus fractures. Choice of the correct length for potentially four proximal locking screws is essential for postoperative outcome. Due to positioning of the patient, intraoperative determination of the correct length of the anteroposterior (AP) screw with the x-ray beam is particularly challenging even for experienced surgeons. We hypothesized that there would be a correlation between the projected lengths of the different proximal locking screws and therefore the length of the AP-screw could be determined based on the three lateromedial (LM) screws. MATERIALS AND METHODS: In this retrospective study (level of evidence: III) CT-scans of shoulders of 289 patients were 3D reconstructed with the program Horos. Using the manufacturer Stryker's instructions, the four proximal locking screws of the T2 Humeral Nail system were reproduced in the 3D reconstructed shoulders. The length of the AP-screw was correlated with the lengths of the LM-screws by Linear Regression and Multiple Linear Regression. RESULTS: The results of this study showed that the lengths of proximal locking screws in proximal humeral nailing correlated significantly with each other. Based on the given data, a formula could be established to calculate the length of the AP-screw based on the lengths of the LM-screws with a probability of 76.5%. CONCLUSIONS: This study was able to show that the length of the AP-screw could be determined from the intraoperatively measured lengths of the LM-screws. As our findings base on measurements performed in CT scans, clinical studies are needed to support our data.


Assuntos
Úmero , Fraturas do Ombro , Humanos , Estudos Retrospectivos , Úmero/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Tomografia Computadorizada por Raios X , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Placas Ósseas
16.
Surg Radiol Anat ; 45(12): 1587-1592, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37837464

RESUMO

PURPOSE: A comprehensive analysis of the morphology of fractures of the coronoid process (CP) can aid diagnosis and guide treatment. The involvement of the radial notch of the ulna (RN)-e.g., in anterolateral facet fractures and transverse fractures of the CP-may influence the biomechanical conditions of the proximal radioulnar joint. However, the morphometric relation between the CP and the RN and the extent to what the proximal radioulnar joint can be affected in these types of fractures is unknown. METHODS: A total of 113 embalmed, cadaveric ulnae were dissected. All soft tissue was removed. Strictly lateral, high-resolution photographs were taken and digitally analyzed. The height of the CP and its relation to the RN was measured. Sex differences and correlations between measured parameters were calculated. RESULTS: Mean height of the CP was 16 mm (range: 12-23 mm; SD: 2). Mean height of the RN was 16 mm (11-25 mm; 2.2). The 50% mark of the CP corresponded to 18% (0-56%; 11.2) of the height of the RN. No significant differences were found between male and female specimens. CONCLUSION: The RN of the ulna extends only to a small part to the CP. Transverse or anterolateral fractures of less than 50% of the coronoid process may involve only a small portion of the proximal radioulnar joint.


Assuntos
Articulação do Cotovelo , Fraturas do Rádio , Fraturas da Ulna , Humanos , Masculino , Feminino , Ulna/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Extremidade Superior
17.
Surg Radiol Anat ; 45(5): 571-580, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36892617

RESUMO

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.


Assuntos
Articulação do Cotovelo , Úmero , Adulto , Humanos , Reprodutibilidade dos Testes , Úmero/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Cotovelo/diagnóstico por imagem , Radiografia
18.
Eur J Orthop Surg Traumatol ; 33(8): 3643-3648, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37268872

RESUMO

PURPOSE: After major COVID-19 lockdown measures were suspended in 2021, E-scooter mobility regrew rapidly. In the meantime, multiple studies were published on the potential risks for e-scooter drivers and the necessity for wearing protective equipment. But did the drivers learn their lessons? METHODS: We observed data of E-scooter-related accidents admitted to the emergency department of a level 1 German trauma center in the year 2021 and compared the data with our previous report (July 2019-July 2020). RESULTS: N = 97 E-scooter-related accidents were included, marking a 50% increase when compared to the previous observation. Most patients were young adults (28.18 ± 1.13 years) with a notable shift towards a male population (25 vs. 63, p = 0.007). While the injury pattern remained unchanged, injury severity, reflected by a significant increase in shock room treatments (p = 0.005), hospital admissions (p = 0.45), and ICU admissions (p = 0.028), increased. Lastly, we report a higher injury severity of patients driving under the influence of alcohol, expressed by significant differences in hospital admissions, shock room treatments, ICU admissions, intracerebral bleeding (p < 0.0001), and injuries requiring surgery (p = 0.0017). CONCLUSION: The increase in injury severity and especially the substantial number of accidents due to driving under the influence of alcohol, are alarming for both trauma- and neurosurgeons. As the controversy surrounding the general use of E-scooters will continue, we urge representatives to intensify their efforts regarding prevention campaigns focusing on the potential dangers of E-scooters, especially when driving under the influence of alcohol.


Assuntos
Acidentes , Centros de Traumatologia , Adulto Jovem , Humanos , Masculino , Seguimentos , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Acidentes de Trânsito/prevenção & controle
19.
J Hand Surg Am ; 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36400651

RESUMO

PURPOSE: Indirect fixation of coronoid process fractures of the ulna, especially arthroscopically, offers the possibility to avoid extensive medial surgical approaches. However, optimal placement of K-wires for cannulated screw fixation is technically challenging. The aim of the present study was to present guide values for K-wire placement for indirect screw fixation of coronoid tip (COT) and anteromedial facet (AMF) fractures of the ulna. METHODS: Computed tomography scans of the elbows of 197 patients with an uninjured ulna were identified and evaluated following a standard measuring protocol. Optimal placement of K-wires was defined as the bisector between the anterior and articular cortex while respecting a 1.6-mm safe zone for each placement. This placement of the K-wires in the COT and the AMF was analyzed by measuring the wire angulation in relation to the posterior ulnar cortex (AUC), the distance from the entry point to the posterior olecranon edge (DPE), and the intraosseous length (IOL). Because the coronoid has a curved shape, measurements of the COT and AMF were expected to differ significantly. Sex was also expected to influence measurements. To determine whether this optimal placement of K-wires can be reliably identified, interobserver and intraobserver reliabilities were evaluated. RESULTS: To address tip fragments, we determined a mean AUC of 64°, DPE of 36 mm, and IOL of 38 mm. Regarding wire placement toward the AMF, the means for the AUC, DPE, and IOL were 79°, 27 mm, and 33 mm, respectively. Statistically significant differences were found between the COT and the AMF for the AUC, DPE, and IOL. Our measuring protocol showed good interobserver and intraobserver reliability. CONCLUSIONS: K-wire placement toward the COT demands a smaller angle, a longer IOL, and a more distal entry point than wires placed toward AMF. These differences reflect the curved and complex anatomy of the coronoid. CLINICAL RELEVANCE: This measuring algorithm can be used to plan osteosynthesis, and the obtained reference values can help understand the coronoid's complex anatomy.

20.
J Shoulder Elbow Surg ; 31(8): 1666-1673, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35247574

RESUMO

BACKGROUND: The purpose of this study was to investigate the primary stability and displacement tendencies of an external fixation system in 2 different configurations in comparison to locking plate fixation in a 3-part proximal humeral fracture model. METHODS: Twenty-one fresh-frozen human cadaveric proximal humeral specimens were divided into 3 groups of 7 stripped specimens. An unstable 3-part fracture of the proximal humerus was set. Construct A consisted of the Galaxy Fixation Shoulder System, with fixation in accordance with the manufacturer's recommended technique (3 pairs of threaded wires). Construct B was fixed with an additional pair of threaded wires according to the recommendations of Gumina et al (4 pairs of threaded wires). The remaining 7 specimens were fixed with a locking plate. By use of an optical motion capture system, relative motion at the fracture site and failure load were evaluated during a cyclic loading protocol. RESULTS: Plate osteosynthesis showed the highest cyclic load to failure (895 ± 239 N; range, 597-1135 N), followed by construct B (692 ± 121 N; range, 432-788 N) and construct A (350 ± 190 N; range, 139-615 N). Statistically significant differences were found between plating and construct A (P < .001), between plating and construct B (P = .031), and between construct B and construct A (P = .013). Relative motion at the fracture site, in terms of change in distance during cyclic loading, was lowest with construct B measured at the peak load of 395 N after 11 steps (1.73 ± 1.98 mm; range, 0.53-5.96 mm) and highest with construct A (8.46 ± 10.67 mm; range, 2.26-20.79 mm). Angular change measured at the peak load after 11 steps was lowest with construct B (1.19° ± 0.36°; range, 0.59°-1.7°) and highest with construct A (2.44° ± 1.63°; range, 0.77°-4.04°). Statistically significant differences were found between construct A and construct B and between construct A and plating at various steps of cyclic loading. CONCLUSION: In this biomechanical study of unstable 3-part proximal humeral fractures, locking plate osteosynthesis demonstrated the highest possible load application. External fixator application with 8 threaded wires (construct B) revealed the least relative motion at the fracture site, without a statistically significant difference compared with locking plates. It therefore represents another valid technique for treatment regarding primary stability. The use of external fixator application with 6 threaded wires (construct A) resulted in the lowest stability and the highest rates of displacement.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Humanos , Úmero/cirurgia , Ombro , Fraturas do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa