Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 296
Filtrar
1.
Radiology ; 310(3): e231429, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38530172

RESUMO

Background Differentiating between benign and malignant vertebral fractures poses diagnostic challenges. Purpose To investigate the reliability of CT-based deep learning models to differentiate between benign and malignant vertebral fractures. Materials and Methods CT scans acquired in patients with benign or malignant vertebral fractures from June 2005 to December 2022 at two university hospitals were retrospectively identified based on a composite reference standard that included histopathologic and radiologic information. An internal test set was randomly selected, and an external test set was obtained from an additional hospital. Models used a three-dimensional U-Net encoder-classifier architecture and applied data augmentation during training. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with that of two residents and one fellowship-trained radiologist using the DeLong test. Results The training set included 381 patients (mean age, 69.9 years ± 11.4 [SD]; 193 male) with 1307 vertebrae (378 benign fractures, 447 malignant fractures, 482 malignant lesions). Internal and external test sets included 86 (mean age, 66.9 years ± 12; 45 male) and 65 (mean age, 68.8 years ± 12.5; 39 female) patients, respectively. The better-performing model of two training approaches achieved AUCs of 0.85 (95% CI: 0.77, 0.92) in the internal and 0.75 (95% CI: 0.64, 0.85) in the external test sets. Including an uncertainty category further improved performance to AUCs of 0.91 (95% CI: 0.83, 0.97) in the internal test set and 0.76 (95% CI: 0.64, 0.88) in the external test set. The AUC values of residents were lower than that of the best-performing model in the internal test set (AUC, 0.69 [95% CI: 0.59, 0.78] and 0.71 [95% CI: 0.61, 0.80]) and external test set (AUC, 0.70 [95% CI: 0.58, 0.80] and 0.71 [95% CI: 0.60, 0.82]), with significant differences only for the internal test set (P < .001). The AUCs of the fellowship-trained radiologist were similar to those of the best-performing model (internal test set, 0.86 [95% CI: 0.78, 0.93; P = .39]; external test set, 0.71 [95% CI: 0.60, 0.82; P = .46]). Conclusion Developed models showed a high discriminatory power to differentiate between benign and malignant vertebral fractures, surpassing or matching the performance of radiology residents and matching that of a fellowship-trained radiologist. © RSNA, 2024 See also the editorial by Booz and D'Angelo in this issue.


Assuntos
Aprendizado Profundo , Fraturas da Coluna Vertebral , Humanos , Feminino , Masculino , Idoso , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Hospitais Universitários
2.
Int J Obes (Lond) ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926461

RESUMO

BACKGROUND/OBJECTIVES: Weight loss outcomes vary individually. Magnetic resonance imaging (MRI)-based evaluation of adipose tissue (AT) might help to identify AT characteristics that predict AT loss. This study aimed to assess the impact of an 8-week low-calorie diet (LCD) on different AT depots and to identify predictors of short-term AT loss using MRI in adults with obesity. METHODS: Eighty-one adults with obesity (mean BMI 34.08 ± 2.75 kg/m², mean age 46.3 ± 10.97 years, 49 females) prospectively underwent baseline MRI (liver dome to femoral head) and anthropometric measurements (BMI, waist-to-hip-ratio, body fat), followed by a post-LCD-examination. Visceral and subcutaneous AT (VAT and SAT) volumes and AT fat fraction were extracted from the MRI data. Apparent lipid volumes based on MRI were calculated as approximation for the lipid contained in the AT. SAT and VAT volumes were subdivided into equidistant thirds along the craniocaudal axis and normalized by length of the segmentation. T-tests compared baseline and follow-up measurements and sex differences. Effect sizes on subdivided AT volumes were compared. Spearman Rank correlation explored associations between baseline parameters and AT loss. Multiple regression analysis identified baseline predictors for AT loss. RESULTS: Following the LCD, participants exhibited significant weight loss (11.61 ± 3.07 kg, p < 0.01) and reductions in all MRI-based AT parameters (p < 0.01). Absolute SAT loss exceeded VAT loss, while relative apparent lipid loss was higher in VAT (both p < 0.01). The lower abdominopelvic third showed the most significant SAT and VAT reduction. The predictor of most AT and apparent lipid losses was the normalized baseline SAT volume in the lower abdominopelvic third, with smaller volumes favoring greater AT loss (p < 0.01 for SAT and VAT loss and SAT apparent lipid volume loss). CONCLUSIONS: The LCD primarily reduces lower abdominopelvic SAT and VAT. Furthermore, lower abdominopelvic SAT volume was detected as a potential predictor for short-term AT loss in persons with obesity.

3.
NMR Biomed ; : e5147, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561247

RESUMO

Partial Fourier encoding is popular in single-shot (ss) diffusion-weighted (DW) echo planar imaging (EPI) because it enables a shorter echo time (TE) and, hence, improves the signal-to-noise-ratio. Motion during diffusion encoding causes k-space shifting and dispersion, which compromises the quality of the homodyne reconstruction. This work provides a comprehensive understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data in the presence of motion-induced phase and proposes the motion-induced phase-corrected homodyne (mpc-hdyne) reconstruction method to ameliorate these artifacts. Simulations with different types of motion-induced phase were performed to provide an understanding of the potential artifacts that occur in the homodyne reconstruction of partial Fourier ss-DW-EPI data. To correct for the artifacts, the mpc-hdyne reconstruction is proposed. The algorithm recenters k-space, updates the partial Fourier factor according to detected global k-space shifts, and removes low-resolution nonlinear phase before the conventional homodyne reconstruction. The mpc-hdyne reconstruction is tested on both simulation and in vivo data. Motion-induced phase can cause signal overestimation, worm artifacts, and signal loss in partial Fourier ss-DW-EPI data with the conventional homodyne reconstruction. Simulation and in vivo data showed that the proposed mpc-hdyne reconstruction ameliorated artifacts, yielding higher quality DW images compared with conventional homodyne reconstruction. Based on the understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data, the mpc-hdyne reconstruction was proposed and showed superior performance compared with the conventional homodyne reconstruction on both simulation and in vivo data.

4.
NMR Biomed ; 37(5): e5097, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38269568

RESUMO

PURPOSE: Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS: The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS: The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities ( wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability ( wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS ( wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI ( wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION: A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Abdome , Respiração , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coração
5.
J Magn Reson Imaging ; 59(5): 1542-1552, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37501387

RESUMO

BACKGROUND: Several magnetic resonance (MR) techniques have been suggested for radiation-free imaging of osseous structures. PURPOSE: To compare the diagnostic value of ultra-short echo time and gradient echo T1-weighted MRI for the assessment of vertebral pathologies using histology and computed tomography (CT) as the reference standard. STUDY TYPE: Prospective. SUBJECTS: Fifty-nine lumbar vertebral bodies harvested from 20 human cadavers (donor age 73 ± 13 years; 9 male). FIELD STRENGTH/SEQUENCE: Ultra-short echo time sequence optimized for both bone (UTEb) and cartilage (UTEc) imaging and 3D T1-weighted gradient-echo sequence (T1GRE) at 3 T; susceptibility-weighted imaging (SWI) gradient echo sequence at 1.5 T. CT was performed on a dual-layer dual-energy CT scanner using a routine clinical protocol. ASSESSMENT: Histopathology and conventional CT were acquired as standard of reference. Semi-quantitative and quantitative morphological features of degenerative changes of the spines were evaluated by four radiologists independently on CT and MR images independently and blinded to all other information. Features assessed were osteophytes, endplate sclerosis, visualization of cartilaginous endplate, facet joint degeneration, presence of Schmorl's nodes, and vertebral dimensions. Vertebral disorders were assessed by a pathologist on histology. STATISTICAL TESTS: Agreement between T1GRE, SWI, UTEc, and UTEb sequences and CT imaging and histology as standard of reference were assessed using Fleiss' κ and intra-class correlation coefficients, respectively. RESULTS: For the morphological assessment of osteophytes and endplate sclerosis, the overall agreement between SWI, T1GRE, UTEb, and UTEc with the reference standard (histology combined with CT) was moderate to almost perfect for all readers (osteophytes: SWI, κ range: 0.68-0.76; T1GRE: 0.92-1.00; UTEb: 0.92-1.00; UTEc: 0.77-0.85; sclerosis: SWI, κ range: 0.60-0.70; T1GRE: 0.77-0.82; UTEb: 0.81-0.92; UTEc: 0.61-0.71). For the visualization of the cartilaginous endplate, UTEc showed the overall best agreement with the reference standard (histology) for all readers (κ range: 0.85-0.93). DATA CONCLUSIONS: Morphological assessment of vertebral pathologies was feasible and accurate using the MR-based bone imaging sequences compared to CT and histopathology. T1GRE showed the overall best performance for osseous changes and UTEc for the visualization of the cartilaginous endplate. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Osteófito , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Esclerose , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Vértebras Lombares/diagnóstico por imagem , Padrões de Referência
6.
Eur Radiol ; 34(4): 2487-2499, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37672058

RESUMO

OBJECTIVES: Differentiation between high-grade glioma (HGG) and post-treatment-related effects (PTRE) is challenging, but advanced imaging techniques were shown to provide benefit. We aim to investigate microstructure characteristics of metabolic compartments identified from amino acid PET and to evaluate the diagnostic potential of this multimodal and integrative O-(2-18F-fluoroethyl)-L-tyrosine-(FET)-PET and fast diffusion kurtosis imaging (DKI) approach for the detection of recurrence and IDH genotyping. METHODS: Fifty-nine participants with neuropathologically confirmed recurrent HGG (n = 39) or PTRE (n = 20) were investigated using static 18F-FET PET and a fast-DKI variant. PET and advanced diffusion metrics of metabolically defined (80-100% and 60-75% areas of 18F-FET uptake) compartments were assessed. Comparative analysis was performed using Mann-Whitney U tests with Holm-Sídák multiple-comparison test and Wilcoxon signed-rank test. Receiver operating characteristic (ROC) curves, regression, and Spearman's correlation analysis were used for statistical evaluations. RESULTS: Compared to PTRE, recurrent HGG presented increased 18F-FET uptake and diffusivity (MD60), but lower (relative) mean kurtosis tensor (rMKT60) and fractional anisotropy (FA60) (respectively p < .05). Diffusion metrics determined from the metabolic periphery showed improved diagnostic performance - most pronounced for FA60 (AUC = 0.86, p < .001), which presented similar benefit to 18F-FET PET (AUC = 0.86, p < .001) and was negatively correlated with amino acid uptake (rs = - 0.46, p < .001). When PET and DKI metrics were evaluated in a multimodal biparametric approach, TBRmax + FA60 showed highest diagnostic accuracy (AUC = 0.93, p < .001), which improved the detection of relapse compared to PET alone (difference in AUC = 0.069, p = .04). FA60 and MD60 distinguished the IDH genotype in the post-treatment setting. CONCLUSION: Detection of glioma recurrence benefits from a multimodal and integrative PET/DKI approach, which presented significant diagnostic advantage to the assessment based on PET alone. CLINICAL RELEVANCE STATEMENT: A multimodal and integrative 18F-FET PET/fast-DKI approach for the non-invasive microstructural characterization of metabolic compartments provided improved diagnostic capability for differentiation between recurrent glioma and post-treatment-related changes, suggesting a role for the diagnostic workup of patients in post-treatment settings. KEY POINTS: • Multimodal PET/MRI with integrative analysis of 18F-FET PET and fast-DKI presents clinical benefit for the assessment of CNS cancer, particularly for the detection of recurrent high-grade glioma. • Microstructure markers of the metabolic periphery yielded biologically pertinent estimates characterising the tumour microenvironment, and, thereby, presented improved diagnostic accuracy with similar accuracy to amino acid PET. • Combined 18F-FET PET/fast-DKI achieved the best diagnostic performance for detection of high-grade glioma relapse with significant benefit to the assessment based on PET alone.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Glioma/diagnóstico por imagem , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Doença Crônica , Tirosina , Recidiva , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Microambiente Tumoral
7.
Eur Radiol ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38388721

RESUMO

OBJECTIVE: This study analyzes the potential cost-effectiveness of integrating an artificial intelligence (AI)-assisted system into the differentiation of incidental renal lesions as benign or malignant on MR images during follow-up. MATERIALS AND METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs, a decision model was created, including the MRI strategy and MRI + AI strategy. Model input parameters were derived from recent literature. Willingness to pay (WTP) was set to $100,000/QALY. Costs of $0 for the AI were assumed in the base-case scenario. Model uncertainty and costs of the AI system were assessed using deterministic and probabilistic sensitivity analysis. RESULTS: Average total costs were at $8054 for the MRI strategy and $7939 for additional use of an AI-based algorithm. The model yielded a cumulative effectiveness of 8.76 QALYs for the MRI strategy and of 8.77 for the MRI + AI strategy. The economically dominant strategy was MRI + AI. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with the incremental cost-effectiveness ratio (ICER), which represents the incremental cost associated with one additional QALY gained, remaining below the WTP for variation of the input parameters. If increasing costs for the algorithm, the ICER of $0/QALY was exceeded at $115, and the defined WTP was exceeded at $667 for the use of the AI. CONCLUSIONS: This analysis, rooted in assumptions, suggests that the additional use of an AI-based algorithm may be a potentially cost-effective alternative in the differentiation of incidental renal lesions using MRI and needs to be confirmed in the future. CLINICAL RELEVANCE STATEMENT: These results hint at AI's the potential impact on diagnosing renal masses. While the current study urges careful interpretation, ongoing research is essential to confirm and seamlessly integrate AI into clinical practice, ensuring its efficacy in routine diagnostics. KEY POINTS: • This is a model-based study using data from literature where AI has been applied in the diagnostic workup of incidental renal lesions. • MRI + AI has the potential to be a cost-effective alternative in the differentiation of incidental renal lesions. • The additional use of AI can reduce costs in the diagnostic workup of incidental renal lesions.

8.
Eur Radiol ; 34(4): 2437-2444, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691079

RESUMO

OBJECTIVES: MR imaging-based proton density fat fraction (PDFF) and T2* imaging has shown to be useful for the evaluation of degenerative changes in the spine. Therefore, the aim of this study was to investigate the influence of myelotoxic chemotherapy on the PDFF and T2* of the thoracolumbar spine in comparison to changes in bone mineral density (BMD). METHODS: In this study, 19 patients were included who had received myelotoxic chemotherapy (MC) and had received a MR imaging scan of the thoracolumbar vertebrates before and after the MC. Every patient was matched for age, sex, and time between the MRI scans to two controls without MC. All patients underwent 3-T MR imaging including the thoracolumbar spine comprising chemical shift encoding-based water-fat imaging to extract PDFF and T2* maps. Moreover, trabecular BMD values were determined before and after chemotherapy. Longitudinal changes in PDFF and T2* were evaluated and compared to changes in BMD. RESULTS: Absolute mean differences of PDFF values between scans before and after MC were at 8.7% (p = 0.01) and at -0.5% (p = 0.57) in the control group, resulting in significantly higher changes in PDFF in patients with MC (p = 0.008). BMD and T2* values neither showed significant changes in patients with nor in those without myelotoxic chemotherapy (p = 0.15 and p = 0.47). There was an inverse, yet non-significant correlation between changes in PDFF and BMD found in patients with myelotoxic chemotherapy (r = -0.41, p = 0.12). CONCLUSION: Therefore, PDFF could be a useful non-invasive biomarker in order to detect changes in the bone marrow in patients receiving myelotoxic therapy. CLINICAL RELEVANCE STATEMENT: Using PDFF as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment may help enable more targeted countermeasures at commencing states of bone marrow degradation and reduce risks of possible fragility fractures. KEY POINTS: Quantifying changes in bone marrow fat fraction, as well as T2* caused by myelotoxic pharmaceuticals using proton density fat fraction, is feasible. Proton density fat fraction could potentially be established as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment.


Assuntos
Medula Óssea , Prótons , Humanos , Medula Óssea/diagnóstico por imagem , Coluna Vertebral , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Tecido Adiposo/diagnóstico por imagem
9.
Br J Clin Pharmacol ; 90(3): 649-661, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37728146

RESUMO

AIMS: To explore international undergraduate pharmacy students' views on integrating artificial intelligence (AI) into pharmacy education and practice. METHODS: This cross-sectional institutional review board-approved multinational, multicentre study comprised an anonymous online survey of 14 multiple-choice items to assess pharmacy students' preferences for AI events in the pharmacy curriculum, the current state of AI education, and students' AI knowledge and attitudes towards using AI in the pharmacy profession, supplemented by 8 demographic queries. Subgroup analyses were performed considering sex, study year, tech-savviness, and prior AI knowledge and AI events in the curriculum using the Mann-Whitney U-test. Variances were reported for responses in Likert scale format. RESULTS: The survey gathered 387 pharmacy student opinions across 16 faculties and 12 countries. Students showed predominantly positive attitudes towards AI in medicine (58%, n = 225) and expressed a strong desire for more AI education (72%, n = 276). However, they reported limited general knowledge of AI (63%, n = 242) and felt inadequately prepared to use AI in their future careers (51%, n = 197). Male students showed more positive attitudes towards increasing efficiency through AI (P = .011), while tech-savvy and advanced-year students expressed heightened concerns about potential legal and ethical issues related to AI (P < .001/P = .025, respectively). Students who had AI courses as part of their studies reported better AI knowledge (P < .001) and felt more prepared to apply it professionally (P < .001). CONCLUSIONS: Our findings underline the generally positive attitude of international pharmacy students towards AI application in medicine and highlight the necessity for a greater emphasis on AI education within pharmacy curricula.


Assuntos
Estudantes de Farmácia , Humanos , Masculino , Estudos Transversais , Inteligência Artificial , Inquéritos e Questionários , Currículo
10.
Int J Colorectal Dis ; 39(1): 21, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273097

RESUMO

PURPOSE: Sigmoid diverticulitis is a disease with a high socioeconomic burden, accounting for a high number of left-sided colonic resections worldwide. Modern surgical scheduling relies on accurate prediction of operation times to enhance patient care and optimize healthcare resources. This study aims to develop a predictive model for surgery duration in laparoscopic sigmoid resections, based on preoperative CT biometric and demographic patient data. METHODS: This retrospective single-center cohort study included 85 patients who underwent laparoscopic sigmoid resection for diverticular disease. Potentially relevant procedure-specific anatomical parameters recommended by a surgical expert were measured in preoperative CT imaging. After random split into training and test set (75% / 25%) multiclass logistic regression was performed and a Random Forest classifier was trained on CT imaging parameters, patient age, and sex in the training cohort to predict categorized surgery duration. The models were evaluated in the test cohort using established performance metrics including receiver operating characteristics area under the curve (AUROC). RESULTS: The Random Forest model achieved a good average AUROC of 0.78. It allowed a very good prediction of long (AUROC = 0.89; specificity 0.71; sensitivity 1.0) and short (AUROC = 0.81; specificity 0.77; sensitivity 0.56) procedures. It clearly outperformed the multiclass logistic regression model (AUROC: average = 0.33; short = 0.31; long = 0.22). CONCLUSION: A Random Forest classifier trained on demographic and CT imaging biometric patient data could predict procedure duration outliers of laparoscopic sigmoid resections. Pending validation in a multicenter study, this approach could potentially improve procedure scheduling in visceral surgery and be scaled to other procedures.


Assuntos
Laparoscopia , Algoritmo Florestas Aleatórias , Humanos , Estudos de Coortes , Laparoscopia/métodos , Estudos Retrospectivos , Resultado do Tratamento
11.
MAGMA ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743376

RESUMO

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

12.
Acta Radiol ; : 2841851241258402, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872362

RESUMO

BACKGROUND: With rising breast augmentations worldwide, there is an increasing clinical need for an early and accurate detection of implant complications. PURPOSE: To compare the quality of chemical shift encoding-based (CSE) water-fat-silicone separation compared to double inversion recovery (DIR) silicone-only imaging in breast magnetic resonance imaging (MRI). MATERIAL AND METHODS: This retrospective, single-center study included women with silicone implants subjected to 3-T MRI between January 2021 and March 2022. MRI included (i) two-dimensional silicone-only T2-weighted turbo spin echo DIR acquisition and (ii) three-dimensional CSE imaging based on multi-echo gradient-echo sequence enabling water-, fat-, and silicone-image separation. Images were evaluated and compared by three independent radiologists using a clinically established rating including differentiability of the silicone implant, visibility and contouring of the adjacent fibrous capsule, and accuracy of intralesional folds in a ranking of 1-5. The apparent contrast-to-noise (aCNR) was calculated. RESULTS: In 71 women, the average quality of water-fat-silicone images from CSE imaging was assessed as "good" (assessment 4 ± 0.9). In 68 (96%) patients, CSE imaging achieved a concise delineation of the silicone implant and precise visualization of the fibrous capsule that was not distinguishable in DIR imaging. Implant ruptures were more easily detected in CSE imaging. The aCNR was higher in CSE compared to DIR imaging (18.43 ± 9.8 vs. 14.73 ± 2.5; P = 0.002). CONCLUSION: Intrinsically co-registered water-fat-silicone-separated CSE-based images enable a reliable assessment of silicone implants. The simultaneously improved differentiability of the implant and fibrous capsule may provide clinicians with a valuable tool for an accurate evaluation of implant integrity and early detection of potential complications.

13.
Skeletal Radiol ; 53(7): 1295-1302, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38224381

RESUMO

OBJECTIVE: Conventional magnetic resonance imaging (MRI) uses T1-weighted and short-tau inversion recovery (STIR) sequences to characterize bone marrow in axial spondyloarthritis. However, quantification is restricted to estimating the extent of lesions because signal intensities are highly variable both within individuals and across patients and MRI scanners. This study evaluates the performance of quantitative T1 mapping for distinguishing different types of bone marrow lesions of the sacroiliac joints. MATERIALS AND METHODS: In this prospective study, 62 patients underwent computed tomography (CT) and MRI of the sacroiliac joints including T1, STIR, and T1 mapping. Bone marrow lesions were characterized by three readers and assigned to one of four groups: sclerosis, osteitis, fat lesions, and mixed marrow lesions. Relaxation times on T1 maps were compared using generalized estimating equations and receiver operating characteristics (ROC) analysis. RESULTS: A total of 119 lesions were selected (sclerosis: 38, osteitis: 27, fat lesions: 40; mixed lesions: 14). T1 maps showed highly significant differences between the lesions with the lowest values for sclerosis (1516±220 ms), followed by osteitis (1909±75 ms), and fat lesions (2391±200 ms); p<0.001. T1 mapping differentiated lesions with areas under the ROC curve of 99% (sclerosis vs. osteitis) and 100% (other comparisons). CONCLUSION: T1 mapping allows accurate characterization of sclerosis, osteitis, and fat lesions at the sacroiliac joint but only for homogeneous, non-mixed lesions. Thus, further sequence development is needed before implementation in clinical routine.


Assuntos
Espondiloartrite Axial , Imageamento por Ressonância Magnética , Articulação Sacroilíaca , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Adulto , Estudos Prospectivos , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/patologia , Tomografia Computadorizada por Raios X/métodos , Espondiloartrite Axial/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Pessoa de Meia-Idade , Doenças da Medula Óssea/diagnóstico por imagem , Osteíte/diagnóstico por imagem
15.
J Med Internet Res ; 26: e54948, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691404

RESUMO

This study demonstrates that GPT-4V outperforms GPT-4 across radiology subspecialties in analyzing 207 cases with 1312 images from the Radiological Society of North America Case Collection.


Assuntos
Radiologia , Radiologia/métodos , Radiologia/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/métodos
16.
Int J Cancer ; 152(5): 854-864, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36121664

RESUMO

PROBASE is a population-based, randomized trial of 46 495 German men recruited at age 45 to compare effects of risk-adapted prostate cancer (PCa) screening starting either immediately at age 45, or at a deferred age of 50 years. Based on prostate-specific antigen (PSA) levels, men are classified into risk groups with different screening intervals: low-risk (<1.5 ng/ml, 5-yearly screening), intermediate-risk (1.5-2.99 ng/ml, 2 yearly), and high risk (>3 ng/ml, recommendation for immediate biopsy). Over the first 6 years of study participation, attendance rates to scheduled screening visits varied from 70.5% to 79.4%, depending on the study arm and risk group allocation, in addition 11.2% to 25.4% of men reported self-initiated PSA tests outside the PROBASE protocol. 38.5% of participants had a history of digital rectal examination or PSA testing prior to recruitment to PROBASE, frequently associated with family history of PCa. These men showed higher rates (33% to 57%, depending on subgroups) of self-initiated PSA testing in-between PROBASE screening rounds. In the high-risk groups (both arms), the biopsy acceptance rate was 64% overall, but was higher among men with screening PSA ≥4 ng/ml (>71%) and with PIRADS ≥3 findings upon multiparameter magnetic resonance imaging (mpMRI) (>72%), compared with men with PSA ≥3 to 4 ng/ml (57%) or PIRADS score ≤ 2 (59%). Overall, PROBASE shows good acceptance of a risk-adapted PCa screening strategy in Germany. Implementation of such a strategy should be accompanied by a well-structured communication, to explain not only the benefits but also the harms of PSA screening.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Biópsia , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Fatores de Risco
17.
Magn Reson Med ; 89(3): 1068-1082, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36321543

RESUMO

PURPOSE: To (a) define multi-peak fat model-based effective in-phase echo times for quantitative susceptibility mapping (QSM) in water-fat regions, (b) analyze the relationship between fat fraction, field map quantification bias and susceptibility bias, and (c) evaluate the susceptibility mapping performance of the proposed effective in-phase echoes in comparison to single-peak in-phase echoes and water-fat separation for regions where both water and fat are present. METHODS: Effective multipeak in-phase echo times for a bone marrow and a liver fat spectral model were derived from a single voxel simulation. A Monte Carlo simulation was performed to assess the field map estimation error as a function of fat fraction for the different in-phase echoes. Additionally, a phantom scan and in vivo scans in the liver, spine, and breast were performed and evaluated with respect to quantification accuracy. RESULTS: The use of single-peak in-phase echoes can introduce a worst-case susceptibility bias of 0.43 $$ 0.43 $$  ppm. The use of effective multipeak in-phase echoes shows a similar quantitative performance in the numerical simulation, the phantom and in all in vivo anatomies when compared to water-fat separation-based QSM. CONCLUSION: QSM based on the proposed effective multipeak in-phase echoes can alleviate the quantification bias present in QSM based on single-peak in-phase echoes. When compared to water-fat separation-based QSM the proposed effective in-phase echo times achieve a similar quantitative performance while drastically reducing the computational expense for field map estimation.


Assuntos
Imageamento por Ressonância Magnética , Água , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Abdome , Mama , Processamento de Imagem Assistida por Computador/métodos
18.
Magn Reson Med ; 89(1): 144-160, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098347

RESUMO

PURPOSE: To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS: The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS: The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION: Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rim , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Rim/diagnóstico por imagem , Coração/diagnóstico por imagem , Difusão , Reprodutibilidade dos Testes
19.
Magn Reson Med ; 90(3): 1209-1218, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37125658

RESUMO

PURPOSE: To (a) develop a preconditioned water-fat-silicone total field inversion (wfsTFI) algorithm that directly estimates the susceptibility map from complex multi-echo data in the breast in the presence of silicone and to (b) evaluate the performance of wfsTFI for breast quantitative susceptibility mapping (QSM) in silico and in vivo in comparison with formerly proposed methods. METHODS: Numerical simulations and in vivo multi-echo gradient echo breast measurements were performed to compare wfsTFI to a previously proposed field map-based linear total field inversion algorithm (lTFI) with and without the consideration of the chemical shift of silicone in the field map estimation step. Specifically, a simulation based on an in vivo scan and data from five patients were included in the analysis. RESULTS: In the simulation, wfsTFI is able to significantly decrease the normalized root mean square error from lTFI without (4.46) and with (1.77) the consideration of the chemical shift of silicone to 0.68. Both the in silico and in vivo wfsTFI susceptibility maps show reduced shadowing artifacts in local tissue adjacent to silicone, reduced streaking artifacts and no erroneous single voxels of diamagnetic susceptibility in proximity to silicone. CONCLUSION: The proposed wfsTFI method can automatically distinguish between subjects with and without silicone. Furthermore wfsTFI accounts for the presence of silicone in the QSM dipole inversion and allows for the robust estimation of susceptibility in proximity to silicone breast implants and hence allows the visualization of structures that would otherwise be dominated by artifacts on susceptibility maps.


Assuntos
Mama , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Algoritmos , Artefatos , Simulação por Computador , Água , Mapeamento Encefálico/métodos , Encéfalo , Processamento de Imagem Assistida por Computador/métodos
20.
Ann Surg Oncol ; 30(2): 1269-1276, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36352298

RESUMO

PURPOSE: To examine sex-specific differences in renal cell carcinoma (RCC) in relation to abdominal fat accumulation, psoas muscle density, tumor size, pathology, and survival, and to evaluate possible associations with RCC characteristics and outcome. METHODS: A total of 470 patients with RCC who underwent nephrectomy between 2006 and 2019 were included in this retrospective study. Specific characteristics of RCC patients were collected, including sex, height, tumor size, grade, and data on patient survival, if available. Abdominal fat measurements and psoas muscle area were determined at the level of L3 (cm2). RESULTS: Women had a higher subcutaneous (p < 0.001) and men had a higher visceral fat area, relative proportion of visceral fat area (p < 0.001), and psoas muscle index (p < 0.001). Logistic regression analysis showed an association between higher psoas muscle index and lower grade tumors [women: odds ratio (OR) 0.94, 95% confidence interval (CI) 0.89-0.99, p = 0.011; men: OR 0.97 (95% CI, 0.95-0.99, p = 0.012]. Univariate regression analysis demonstrated an association between psoas muscle index and overall survival (women: OR 1.41, 95% CI 1.03-1.93, p = 0.033; men: OR 1.62 (95% CI, 1.33-1.97, p < 0.001). In contrast, there were no associations between abdominal fat measurements and tumor size, grade, or survival. Also, there were no sex-specific differences in tumor size or tumor grades. CONCLUSIONS: A higher preoperative psoas muscle index was independently associated with overall survival in RCC patients, with a stronger association in men compared with women. In addition, the psoas muscle index showed an inverse association with tumor grade, whereby this association was slightly more pronounced in women than in men.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Masculino , Feminino , Carcinoma de Células Renais/patologia , Estudos Retrospectivos , Caracteres Sexuais , Composição Corporal/fisiologia , Músculos Psoas/patologia , Neoplasias Renais/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa