Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181587

RESUMO

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação
2.
Acta Radiol ; 59(12): 1422-1430, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29566549

RESUMO

BACKGROUND: Long-term intensive training induces physiological, morphological, and functional adaption of the athlete's heart. PURPOSE: To evaluate the development of athlete's heart during a mid-term follow-up of competitive athletes using cardiac magnetic resonance (CMR). MATERIAL AND METHODS: Eighteen competitive long-distance runners and triathletes (age 43 ± 13 years, 3 women) were prospectively examined in a longitudinal follow-up study 5.05 ± 0.6 years after baseline. CMR at 1.5-T was performed for functional and late gadolinium enhancement (LGE) imaging. Left ventricular (LV) and right ventricular (RV) end-diastolic volume (LVEDV, RVEDV) as well as ejection fraction (LVEF, RVEF), LV myocardial mass (LVMM), and atrial sizes were determined and compared to baseline in matched pairs statistics for paired difference. RESULTS: LVEDV (197 ± 38 mL vs. 196 ± 38 mL, paired difference -0.9 mL, P = 0.7) and LVEF (62 ± 7% vs. 62 ± 5%, paired difference 0.1%, P = 0.9) did not change during the follow-up period, whereas LVMM increased significantly (149 ± 31 g vs.164 ± 32 g, paired difference 14 g, P < 0.0001). RVEDV significantly increased from 221 ± 47 mL at baseline to 230 ± 52 mL (paired difference 10 mL, P = 0.0033). RVEF decreased from baseline 57 ± 8% to 53 ± 7% (paired difference -3%, P = 0.0234). Left atrial size showed no significant changes (24 ± 5 cm2 vs. 25 ± 6 cm2, paired difference 0.5 cm2, P = 0.17) and right atrial size increased significantly (30 ± 5 cm2 vs. 32 ± 4 cm2, paired difference 2 cm2, P = 0.0054). CONCLUSION: This study supports the theory of ongoing remodeling in an athlete's heart. Predominantly the right heart can further enlarge in a mid-term period. This response seems not linearly dependent on a steady, decreased, or increased training volume.


Assuntos
Atletas , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Função Ventricular/fisiologia , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Gadolínio , Humanos , Aumento da Imagem/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
3.
J Magn Reson Imaging ; 45(5): 1429-1437, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27690324

RESUMO

PURPOSE: To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called "T(Rho) And Magnetization transfer and INvErsion Recovery" (TRAMINER) for the ability to detect myocardial LGE versus standard "bright-blood" inversion recovery (SIR) imaging. MATERIALS AND METHODS: This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann-Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann-Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. RESULTS: Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0-3.0] vs. 2.0 [1.7-2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8-3.0] vs. 2.7 [2.5-2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. CONCLUSION: TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. LEVEL OF EVIDENCE: 2 J. MAGN. RESON. IMAGING 2017;45:1429-1437.


Assuntos
Gadolínio/química , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Eur Radiol ; 27(4): 1377-1385, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27510627

RESUMO

OBJECTIVES: To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). METHODS: Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. RESULTS: A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). CONCLUSION: Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. KEY POINTS: • Fat embolism occurs commonly in patients with traumatic bone injury. • Dual-energy CT improves diagnostic performance for pulmonary fat embolism detection. • Dual-energy CT can detect pulmonary fat embolism earlier than CTPA.


Assuntos
Embolia Gordurosa/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Animais , Modelos Animais de Doenças , Humanos , Artéria Pulmonar/diagnóstico por imagem , Coelhos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Eur Radiol ; 27(8): 3235-3243, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28050692

RESUMO

OBJECTIVES: To evaluate the influence of inversion time (TI) on the precision of myocardial late gadolinium enhancement (LGE) quantification using synthetic inversion recovery (IR) imaging in patients with myocardial infarction (MI). METHODS: Fifty-three patients with suspected prior MI underwent 1.5-T cardiac MRI with conventional magnitude (MagIR) and phase-sensitive IR (PSIR) LGE imaging and T1 mapping at 15 min post-contrast. T1-based synthetic MagIR and PSIR images were calculated with a TI ranging from -100 to +150 ms at 5-ms intervals relative to the optimal TI (TI0). LGE was quantified using a five standard deviation (5SD) and full width at half-maximum (FWHM) thresholds. Measurements were compared using one-way analysis of variance. RESULTS: The MagIRsy technique provided precise assessment of LGE area at TIs ≥ TI0, while precision was decreased below TI0. The LGE area showed significant differences at ≤ -25 ms compared to TI0 using 5SD (P < 0.001) and at ≤ -65 ms using the FWHM approach (P < 0.001). LGE measurements did not show significant difference over the analysed TI range in the PSIRsy images using either of the quantification methods. CONCLUSIONS: T1 map-based PSIRsy images provide precise quantification of MI independent of TI at the investigated time point post-contrast. MagIRsy-based MI quantification is precise at TI0 and at longer TIs while showing decreased precision at TI values below TI0. KEY POINTS: • Synthetic IR imaging retrospectively generates LGE images at any theoretical TI • Synthetic IR imaging can simulate the effect of TI on LGE quantification • Fifteen minutes post-contrast MagIR sy accurately quantifies infarcts from TI 0 to TI 0 + 150 ms • Fifteen minutes post-contrast PSIR sy provides precise infarct size independent of TI • Synthetic IR imaging has further advantages in reducing operator dependence.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Eur Radiol ; 27(5): 1944-1953, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553939

RESUMO

PURPOSE: To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. RESULTS: Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). CONCLUSION: TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS: • Third-generation dual-source CT facilitates low-tube-voltage acquisition. • TAVR planning can be performed with reduced contrast volume and radiation dose. • TAVR-planning CT did not result in changes in creatinine levels at follow-up. • TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.


Assuntos
Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Planejamento de Assistência ao Paciente , Doses de Radiação , Estudos Retrospectivos , Ácidos Tri-Iodobenzoicos
7.
Eur Radiol ; 27(6): 2298-2308, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27682312

RESUMO

PURPOSE: To investigate diagnostic accuracy of 3rd-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. METHODS: We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m2, n = 37) and B (≥30 kg/m2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. RESULTS: Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CONCLUSION: CCTA using 3rd-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. KEY POINTS: • Coronary CTA provides high diagnostic accuracy in non-obese and obese patients. • Diagnostic accuracy between obese and non-obese patients showed no significant difference. • <120 kV studies were performed in 44 % of obese patients. • Current radiation dose-saving approaches can be applied independent of body habitus.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Obesidade/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
8.
Eur Radiol ; 27(2): 642-650, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27165140

RESUMO

OBJECTIVES: To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). METHODS: We retrospectively analysed 200 patients (100 male, 100 female; mean age 61.2 ± 13.5 years, mean body mass index 27.5 ± 3.8 kg/m2) equally divided into four groups matched by gender and body mass index, who had undergone portal venous phase abdominal CT with second-generation (group A, 120-kV-SECT; group B, 80/140-kV-DECT) and third-generation DSCT (group C, 100-kV-SECT; group D, 90/150-kV-DECT). The radiation dose was normalised for 40-cm scan length. Dose-independent figure-of-merit (FOM) contrast-to-noise ratios (CNRs) were calculated for various organs and vessels. Subjective overall image quality and reader confidence were assessed. RESULTS: The effective normalised radiation dose was significantly lower (P < 0.001) in groups C (6.2 ± 2.0 mSv) and D (5.3 ± 1.9 mSv, P = 0.103) compared to groups A (8.8 ± 2.3 mSv) and B (9.7 ± 2.4 mSv, P = 0.102). Dose-independent FOM-CNR peaked for liver, kidney, and portal vein measurements (all P ≤ 0.0285) in group D. Subjective image quality and reader confidence were consistently rated as excellent in all groups (all ≥1.53 out of 5). CONCLUSIONS: With both DSCT generations, abdominal DECT can be routinely performed without radiation dose penalty compared to SECT, while third-generation DSCT shows improved dose efficiency. KEY POINTS: • Dual-source CT (DSCT) allows for single- and dual-energy image acquisition. • Dual-energy acquisition does not increase the radiation dose in abdominal DSCT. • Third-generation DSCT shows improved dose efficiency compared to second-generation DSCT. • Dose-independent figure-of-merit image contrast was highest with third-generation dual-energy DSCT. • Third-generation DSCT shows improved dose efficiency for SECT and DECT.


Assuntos
Doses de Radiação , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
9.
J Comput Assist Tomogr ; 41(5): 804-810, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448412

RESUMO

OBJECTIVES: The aim of this study was to investigate the minimum iodine delivery rate (IDR) and contrast media (CM) volume required for diagnostic contrast enhancement of 350 HU (Hounsfield units) in the ascending aorta at different kV settings. METHODS: Dynamic computed tomography acquisitions from 70 to 150 kV were performed in a circulation phantom. First, injections with IDR ranging from 0.1 to 2.0 g I/s were tested for each kV. In the second part, the IDR was held constant, whereas the CM volume was reduced from 50 to 10 mL. Diagnostic aortic peak enhancement for each kV was compared using the Kruskal-Wallis test. P < 0.05 was considered statistically significant. RESULTS: The mean aortic peak enhancement for all diagnostic IDRs was 368.7 ± 11.1 HU. Diagnostic IDRs returned similar aortic peak enhancement values for all protocols (all P ≥ 0.18). For the second part of the study, a diagnostic enhancement was yielded by using a minimum of 30 mL of CM for 110 kV, 25 mL for 100 and 90 kV, and 15 mL for 80 and 70 kV. CONCLUSION: Our study suggests that a differentiated approach reducing the CM volume for tube voltages of less than 120 kV and increasing the IDR for higher kV settings seems to be the most effective approach.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Iohexol/administração & dosagem
10.
Radiol Med ; 122(4): 280-287, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28070843

RESUMO

PURPOSE: To evaluate noise-optimized monoenergetic postprocessing of dual-energy CT (DE-CT) on image quality in patients with incidental pulmonary embolism in single-pass portal-venous phase CT (CTpv). MATERIALS AND METHODS: 20 Consecutive patients with incidental pulmonary embolism in contrast-enhanced oncological follow-up DE-CTpv examination were included in this study. Images were acquired with a 3rd generation DE-CT system in DE mode (100/Sn150 kV) and activated tube current modulation 90 s after contrast agent administration. Subsequently, virtual monoenergetic images (MEI+) were reconstructed at five different keV levels (40, 55, 70, 85, 100) and compared to the standard linearly blended (M_0.8) CTpv images. Image quality was assessed qualitatively (vascular contrast and detectability of embolism, image noise, iodine influx artifact; two independent readers; 5-point Likert scale; 5 = excellent) and quantitatively by calculating signal-to-noise (SNR) and contrast-to-noise ratios (CNR). RESULTS: Highest vessel contrast and highest detectability of embolism were observed in MEI+ at 40 keV (4.7 ± 0.4) and 55 keV (4.2 ± 0.6) with significant differences as compared to CTpv (3.6 ± 0.5) and high keV reconstructions (70, 85, 100; p ≤ 0.01). Image noise significantly increased at 40 keV MEI+ compared to all other MEI+ reconstructions and CTpv (p < 0.001). SNR and CNR calculations were highest at 40 keV MEI+ followed by 55 keV and CTpv with significant differences to high keV MEI+ (85-100). CONCLUSIONS: Computed MEI+ at low keV levels allow for improved vessel contrast and visualisation of incidental pulmonary embolism in patients with portal-venous phase CT scans by substantially increasing CNR and SNR.


Assuntos
Neoplasias/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
11.
Eur Radiol ; 26(6): 1871-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26373752

RESUMO

PURPOSE: To evaluate the impact of an advanced monoenergetic (ME) reconstruction algorithm on CT coronary stent imaging in a phantom model. MATERIALS AND METHODS: Three stents with lumen diameters of 2.25, 3.0 and 3.5 mm were examined with a third-generation dual-source dual-energy CT (DECT). Tube potential was set at 90/Sn150 kV for DE and 70, 90 or 120 kV for single-energy (SE) acquisitions and advanced modelled iterative reconstruction was used. Overall, 23 reconstructions were evaluated for each stent including three SE acquisitions and ten advanced and standard ME images with virtual photon energies from 40 to 130 keV, respectively. In-stent luminal diameter was measured and compared to nominal lumen diameter to determine stent lumen visibility. Contrast-to-noise ratio was calculated. RESULTS: Advanced ME reconstructions substantially increased lumen visibility in comparison to SE for stents ≤3 mm. 130 keV images produced the best mean lumen visibility: 86 % for the 2.25 mm stent (82 % for standard ME and 64 % for SE) and 82 % for the 3.0 mm stent (77 % for standard ME and 69 % for SE). Mean DLP for SE 120 kV and DE acquisitions were 114.4 ± 9.8 and 58.9 ± 2.2 mGy × cm, respectively. CONCLUSION: DECT with advanced ME reconstructions improves the in-lumen visibility of small stents in comparison with standard ME and SE imaging. KEY POINTS: • An advanced image-based monoenergetic reconstruction algorithm improves lumen visualization in stents ≤3.0 mm. • Application of high keV reconstructions significantly improves in-stent lumen visualization. • DECT acquisition resulted in 49 % radiation dose reduction compared with 120 kV SE.


Assuntos
Algoritmos , Prótese Vascular , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
12.
Eur Radiol ; 26(10): 3608-16, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26847044

RESUMO

OBJECTIVES: To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). METHODS: We evaluated 272 patients who underwent CCTA with 3(rd) generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. RESULTS: Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥ .0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p < .0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥ .0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤ .0414). Correlation analysis showed a moderate association between tube voltage and BMI (r = .639). CONCLUSION: ATVS allows individual tube voltage adaptation for CCTA performed with 3(rd) generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. KEY POINTS: • Automated tube voltage selection allows an individual tube voltage adaption in CCTA. • A tube voltage-based reduction of contrast medium volume is feasible. • Image quality was maintained while radiation exposure was significantly decreased. • A moderate association between tube voltage and body mass index was found.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Adulto , Idoso , Índice de Massa Corporal , Meios de Contraste/administração & dosagem , Esquema de Medicação , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
13.
Eur Radiol ; 26(12): 4380-4389, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26960541

RESUMO

PURPOSE: To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). MATERIAL AND METHODS: We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F_0.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F_0.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. RESULTS: At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F_0.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F_0.5 (90.9, 94.1, 89.3 %). CONCLUSION: 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. KEY POINTS: • The impact of noise-optimized virtual monochromatic imaging on stent visualization was assessed. • Virtual monochromatic imaging significantly improves stent lumen visualization and diagnostic confidence. • At 80 keV diagnostic performance for detection of in-stent restenosis was increased. • 80 keV virtual monochromatic images are recommended for stent evaluation of lower extremity vasculature.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Stents , Adulto , Idoso , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
14.
Eur Radiol ; 26(9): 2937-46, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26712517

RESUMO

OBJECTIVES: To evaluate the image quality of coronary CT angiography (CCTA) in obese patients using a 3(rd) generation, dual-source CT scanner. METHODS: We retrospectively evaluated 102 overweight and obese patients who had undergone CCTA. Studies were performed with 3(rd) generation dual-source CT, prospectively ECG-triggered acquisition at 120 kV, and automated tube current modulation. Advanced modeled iterative reconstruction was used. Patients were divided into three BMI groups: 1)25-29.9 kg/m(2); 2)30-39.9 kg/m(2); 3) ≥ 40 kg/m(2). Vascular attenuation in the coronary arteries was measured. Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using five-point scales. RESULTS: Image quality was considered diagnostic in 97.6 % of examinations. CNR was consistently adequate in all groups but decreased for groups 2 and 3 in comparison to group 1 as well as for group 3 compared to group 2 (p = 0.001, respectively). Subjective image quality was significantly higher in group 1 compared to group 3 (attenuation proximal: 4.8 ± 0.4 vs. 4.4 ± 0.6, p = 0.011; attenuation distal: 4.5 ± 0.7 vs. 4.0 ± 0.8, p = 0.019; noise: 4.7 ± 0.6 vs. 3.8 ± 0.7, p < 0.001). The mean effective dose was 9.5 ± 3.9 mSv for group 1, 11.4 ± 4.7 mSv for group 2 and 14.0 ± 6.4 mSv for group 3. CONCLUSION: Diagnostic image quality can be routinely obtained at CCTA in obese patients with 3(rd) generation DSCT at 120 kV. KEY POINTS: • Diagnostic CCTA can be routinely performed in obese patients with 3 (rd) generation DSCT. • 120-kV tube voltage allows diagnostic image quality in patients with BMI > 40 kg/m (2) . • 80-ml contrast medium can be administered without significant decline in vascular attenuation.


Assuntos
Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Obesidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Eur Radiol ; 26(5): 1503-11, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26267520

RESUMO

OBJECTIVES: To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS: Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. RESULTS: Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17%; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. CONCLUSIONS: Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. KEY POINTS: • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a reference.


Assuntos
Disfunção Ventricular Esquerda/fisiopatologia , Algoritmos , Estudos de Viabilidade , Feminino , Ventrículos do Coração/patologia , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/patologia
16.
Curr Cardiol Rep ; 18(2): 14, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26768740

RESUMO

Transcatheter aortic valve replacement (TAVR) has become an alternative to surgical intervention for symptomatic or severe aortic valve stenosis in patients with high surgical risk. Successful TAVR requires a multimodality imaging approach for appropriate patient selection and prosthesis sizing. Here, we describe individual imaging modalities and report their respective roles in this emerging field. To date, echocardiography remains the traditional test for determining patient candidacy and prosthesis selection, but computed tomography (CT) has been taking on an increasingly important role in the evaluation of both the aortic root anatomy and aortoiliofemoral vessels as a single examination. Cardiac magnetic resonance (CMR) is useful in grading the severity of aortic stenosis and should be considered a reasonable alternative to CT for the evaluation of the aortic annulus, e.g., when the administration of contrast media is contraindicated.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/patologia , Ecocardiografia , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Valva Aórtica/anatomia & histologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Meios de Contraste , Humanos , Imagem Multimodal/métodos , Substituição da Valva Aórtica Transcateter/métodos
17.
Eur Radiol ; 25(6): 1655-64, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25528670

RESUMO

AIMS AND OBJECTIVES: Deep venous thrombosis (DVT) can be difficult to detect using CT due to poor and heterogeneous contrast. Dual-energy CT (DECT) allows iodine contrast optimization using noise-optimized monoenergetic extrapolations (MEIs) and iodine maps (IMs). Our aim was to assess whether MEI and IM could improve the delineation of thrombotic material within iodine-enhanced blood compared to single-energy CT (SECT). MATERIALS AND METHODS: Six vessel phantoms, including human thrombus and contrast media-enhanced blood and one phantom without contrast, were placed in an attenuation phantom and scanned with DECT 100/140 kV and SECT 120 kV. IM, virtual non-contrast images (VNC), mixed images, and MEI were calculated. Attenuation of thrombi and blood were measured. Contrast and contrast-to-noise-ratios (CNRs) were calculated and compared among IM, VNC, mixed images, MEI, and SECT using paired t tests. RESULTS: MEI40keV and IM showed significantly higher contrast and CNR than SE120kV from high to intermediate iodine concentrations (contrast:pMEI40keV < 0.002,pIM < 0.005;CNR:pMEI40keV < 0.002,pIM < 0.004). At low iodine concentrations, MEI190keV and VNC images showed significantly higher contrast and CNR than SE120kV with inverted contrasts (contrast:pMEI190keV < 0.008,pVNC < 0.002;CNR:pMEI190keV < 0.003,pVNC < 0.002). CONCLUSIONS: Noise-optimized MEI and IM provide significantly higher contrast and CNR in the delineation of thrombosis compared to SECT, which may facilitate the detection of DVT in difficult cases. KEY POINTS: • Poor contrast makes it difficult to detect thrombosis in CT. • Dual-energy-CT allows contrast optimization using monoenergetic extrapolations (MEI) and iodine maps (IM). • Noise-optimized-MEI and IM are significantly superior to single-energy-CT in delineation of thrombosis. • Noise-optimized-MEI and IM may facilitate the detection of deep vein thrombosis.


Assuntos
Iodo/administração & dosagem , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Trombose Venosa/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
18.
Appl Environ Microbiol ; 79(7): 2172-81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23354702

RESUMO

Gene transcription (microarrays) and protein levels (proteomics) were compared in cultures of the acidophilic chemolithotroph Acidithiobacillus ferrooxidans grown on elemental sulfur as the electron donor under aerobic and anaerobic conditions, using either molecular oxygen or ferric iron as the electron acceptor, respectively. No evidence supporting the role of either tetrathionate hydrolase or arsenic reductase in mediating the transfer of electrons to ferric iron (as suggested by previous studies) was obtained. In addition, no novel ferric iron reductase was identified. However, data suggested that sulfur was disproportionated under anaerobic conditions, forming hydrogen sulfide via sulfur reductase and sulfate via heterodisulfide reductase and ATP sulfurylase. Supporting physiological evidence for H2S production came from the observation that soluble Cu(2+) included in anaerobically incubated cultures was precipitated (seemingly as CuS). Since H(2)S reduces ferric iron to ferrous in acidic medium, its production under anaerobic conditions indicates that anaerobic iron reduction is mediated, at least in part, by an indirect mechanism. Evidence was obtained for an alternative model implicating the transfer of electrons from S(0) to Fe(3+) via a respiratory chain that includes a bc(1) complex and a cytochrome c. Central carbon pathways were upregulated under aerobic conditions, correlating with higher growth rates, while many Calvin-Benson-Bassham cycle components were upregulated during anaerobic growth, probably as a result of more limited access to carbon dioxide. These results are important for understanding the role of A. ferrooxidans in environmental biogeochemical metal cycling and in industrial bioleaching operations.


Assuntos
Acidithiobacillus/metabolismo , Ferro/metabolismo , Enxofre/metabolismo , Anaerobiose , Perfilação da Expressão Gênica , Sulfeto de Hidrogênio/metabolismo , Redes e Vias Metabólicas/genética , Oxirredução , Proteoma , Transcriptoma
19.
Extremophiles ; 17(4): 689-96, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23712908

RESUMO

Maintenance of a circumneutral intracellular pH is important for any organism. Acidophilic microorganisms thrive at low pH while maintaining their intracellular pH around 6.5. However, the mechanisms contributing to acidophile pH homeostasis are not well characterized. The authors investigated the proteomic response and cytoplasmic membrane fatty acid profiles of Acidithiobacillus caldus toward three pH values: 1.1, 2.5, and 4.0. Major rearrangements were observed but lower pH elicited larger changes. Differentially expressed transcription factors suggested tight transcriptional control of pH induced genes. Enzymes involved in sulfur metabolism were up-regulated at pH 1.1 suggesting either that: (1) cells required more energy for maintenance or (2) increased metabolic activity was a specific acid stress response to export intracellular protons via 1° electron transport proton pumps. Furthermore, glutamate decarboxylase, an important enzyme in Escherichia coli acid resistance, was uniquely expressed at pH 1.1. Other proteins previously shown to be involved in neutrophilic acid response, such as spermidine synthase, PspA, and toluene tolerance protein, were differentially expressed in At. caldus but require further investigation to show a direct link to pH homeostasis. Their roles in acidophilic organisms are discussed. Active modulation of fatty acid profiles was detected and suggested a more rigid membrane at low pH.


Assuntos
Acidithiobacillus/metabolismo , Prótons , Estresse Fisiológico , Acidithiobacillus/genética , Membrana Celular/metabolismo , Ácidos Graxos/metabolismo , Regulação Bacteriana da Expressão Gênica , Genes Bacterianos , Glutamato Descarboxilase/genética , Glutamato Descarboxilase/metabolismo , Homeostase , Concentração de Íons de Hidrogênio , Proteoma/genética , Proteoma/metabolismo , Espermidina Sintase/genética , Espermidina Sintase/metabolismo , Enxofre/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
20.
Extremophiles ; 17(1): 75-85, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23143658

RESUMO

Zinc can occur in extremely high concentrations in acidic, heavy metal polluted environments inhabited by acidophilic prokaryotes. Although these organisms are able to thrive in such severely contaminated ecosystems their resistance mechanisms have not been well studied. Bioinformatic analysis of a range of acidophilic bacterial and archaeal genomes identified homologues of several known zinc homeostasis systems. These included primary and secondary transporters, such as the primary heavy metal exporter ZntA and Nramp super-family secondary importer MntH. Three acidophilic model microorganisms, the archaeon 'Ferroplasma acidarmanus', the Gram negative bacterium Acidithiobacillus caldus, and the Gram positive bacterium Acidimicrobium ferrooxidans, were selected for detailed analyses. Zinc speciation modeling of the growth media demonstrated that a large fraction of the free metal ion is complexed, potentially affecting its toxicity. Indeed, many of the putative zinc homeostasis genes were constitutively expressed and with the exception of 'F. acidarmanus' ZntA, they were not up-regulated in the presence of excess zinc. Proteomic analysis revealed that zinc played a role in oxidative stress in At. caldus and Am. ferrooxidans. Furthermore, 'F. acidarmanus' kept a constant level of intracellular zinc over all conditions tested whereas the intracellular levels increased with increasing zinc exposure in the remaining organisms.


Assuntos
Acidithiobacillus/crescimento & desenvolvimento , Modelos Biológicos , Thermoplasmales/crescimento & desenvolvimento , Microbiologia da Água , Poluentes Químicos da Água/farmacologia , Zinco/farmacologia , Acidithiobacillus/genética , Adenosina Trifosfatases/genética , Adenosina Trifosfatases/metabolismo , Proteínas Arqueais/genética , Proteínas Arqueais/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Proteínas de Transporte de Cátions/genética , Proteínas de Transporte de Cátions/metabolismo , Thermoplasmales/genética
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa