Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 212
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(2): 343-355, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39031623

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) represents an alternative to oral anticoagulation for stroke prevention in patients with non-valvular atrial fibrillation (AF). While transoesophageal echocardiography is the current standard for guiding LAAC procedures, several centers have employed fluoroscopic guidance alone. However, data on long-term outcomes are lacking. METHODS: A total of 536 patients with AF undergoing LAAC and with available data on long-term follow-up were included in the retrospective, single-center analysis. Outcomes of patients undergoing fluoroscopy-guided LAAC were compared with those undergoing echocardiography guided LAAC. Time-dependent analysis was performed with the Kaplan-Meier method. RESULTS: A total of 234 (44%) and 302 (56%) patients were treated with echocardiography and fluoroscopy guidance, respectively. Baseline characteristics did not differ between the two groups. Procedural success rates were high in both groups (97% of fluoroscopy vs. 98% of echocardiography guided procedures; p = 0.92) and rates of relevant peri-device leaks (p = 0.50) and device-related thrombus formation (p = 0.22) did not differ between groups. Median clinical follow-up time was 48 (IQR 19-73) months. Rates of all-cause mortality (p = 0.15, HR 0.83, CI 0.64-1.07) and stroke (p = 0.076, HR 2.23, CI 0.90-5.54) were comparable among groups. CONCLUSION: LAAC with fluoroscopy guidance alone is equally safe and leads to similar clinical outcome compared to LAAC with additional echocardiography guidance.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Radiografia Intervencionista , Acidente Vascular Cerebral , Ultrassonografia de Intervenção , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/mortalidade , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Estudos Retrospectivos , Fluoroscopia , Masculino , Feminino , Idoso , Fatores de Tempo , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Ultrassonografia de Intervenção/efeitos adversos , Fatores de Risco , Radiografia Intervencionista/efeitos adversos , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Oclusão do Apêndice Atrial Esquerdo
2.
Am Heart J ; 228: 27-35, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32745733

RESUMO

BACKGROUND: Limited data suggest that transcatheter (TAVR) as compared with surgical aortic valve replacement (SAVR) may be more effective in female than male patients. To date, most evidence is derived from subgroup analyses of large trials, and a dedicated randomized trial evaluating whether there is a difference in outcomes between these interventions in women is warranted. The RHEIA trial will compare the safety and efficacy of TAVR with SAVR in women with severe symptomatic aortic stenosis requiring aortic valve intervention, irrespective of surgical risk. METHODS/DESIGN: The RHEIA trial is a prospective, randomized, controlled study that will enroll up to 440 patients across 35 sites in Europe. Women with severe symptomatic aortic stenosis, with any but prohibitive surgical risk status, will be randomized 1:1 to undergo aortic valve intervention with either transfemoral TAVR with the SAPIEN 3 or SAPIEN 3 Ultra device or SAVR and followed up for 1 year. The objective is to determine whether TAVR is non-inferior to SAVR in this patient population and, if this is fulfilled whether TAVR is actually superior to SAVR. The primary safety/efficacy endpoint is a composite of all-cause mortality, all stroke, and re-hospitalization (for valve or procedure-related symptoms or worsening congestive heart failure) at 1 year post-procedure. Other outcomes (assessed at 30 days and/or 1 year) include all-cause mortality; bleeding, vascular, cardiac, cerebrovascular and renal complications; aortic valve prosthesis and left ventricular function; cognitive function, health status, and quality of life. DISCUSSION: The RHEIA study has been designed to evaluate the safety and efficacy of TAVR compared with SAVR specifically in women with severe symptomatic aortic stenosis, irrespective of the level of surgical risk. The results will be the first to provide specific randomized evidence to guide treatment selection in female patients with severe symptomatic aortic stenosis. TRIAL REGISTRATION: clinicaltrials.gov: NCT04160130.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias , Qualidade de Vida , Risco Ajustado/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/psicologia , Estenose da Valva Aórtica/cirurgia , Feminino , Nível de Saúde , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/classificação , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/psicologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
3.
Catheter Cardiovasc Interv ; 96(3): E324-E331, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31631493

RESUMO

OBJECTIVES: To compare long-term clinical outcomes after left atrial appendage closure with the Amplatzer Cardiac Plug (ACP) and Amulet. BACKGROUND: The Amulet was designed to improve clinical outcomes of first-generation ACP. METHODS: Three Amplatzer registries (Bern, Coburg, Zurich), with enrollment of patients from 2009 to 2018, were retrospectively analyzed. The primary safety endpoint was a composite of major peri-procedural complications and major bleedings, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. The net clinical benefit was a combination of all above-mentioned hazards. RESULTS: A total of consecutive 563 patients (344 ACP vs. 219 Amulet) with a mean follow-up of 2.9 ± 1.6 and 1.9 ± 0.9 years were included. Mean age (74.4 ± 9.9 [ACP] vs. 74.4 ± 9.1 [Amulet] years), stroke (CHA2 DS2 -VASc score 4.4 ± 1.6 vs. 4.6 ± 1.7), and bleeding risk (HAS-BLED score 3.2 ± 1.1 vs. 3.2 ± 0.9) were comparable. The primary endpoints of efficacy (72/998, 7.2% [ACP] vs. 43/417, 10.3% [Amulet]; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.44-1.02, p = .062), safety (40/998, 4.0% vs. 18/417, 4.3%; HR, 1.15; 95% CI, 0.53-2.51, p = .72), and the net clinical benefit (101/998, 10.1% vs. 55/417, 13.4%; HR, 0.73; 95% CI, 0.49-1.07, p = .11) were similar. CONCLUSION: In the long term, left atrial appendage closure with first and second-generation Amplatzer devices provided similar efficacy, safety, and net clinical benefit. Clinical outcomes may be rather determined by implantation technique and hemodynamics, but not by the design modifications of the Amulet.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Feminino , Alemanha , Frequência Cardíaca , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Suíça , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 95(6): 1186-1192, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31483555

RESUMO

OBJECTIVES: To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve. BACKGROUND: Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce. METHODS: We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve. RESULTS: Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%. CONCLUSIONS: Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Canadá , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Europace ; 22(6): 916-923, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32003774

RESUMO

AIMS: This study compares clinical outcomes of Watchman vs. Amplatzer devices for left atrial appendage closure (LAAC). METHODS AND RESULTS: Of two real-world registries, the Watchman registry Lichtenfels, Germany, and the Amplatzer registry Bern-Zurich, Switzerland, 303 and 333 consecutive patients, respectively, were included. After a 1:1 propensity score matching, 266 vs. 266 patients were compared by use of the predefined primary efficacy endpoint of stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major peri-procedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. Mean age was 75.3 ± 7.8 (Watchman) vs. 75.1 ± 9.9 (Amplatzer) years, CHA2DS2-VASc score 4.5 ± 1.7 vs. 4.5 ± 1.5, and HAS-BLED score 3.2 ± 1.0 vs. 3.2 ± 1.0. At a mean follow-up of 2.4 ± 1.3 vs. 2.5 ± 1.5 years and 1.322 patient-years, the primary endpoints of efficacy [40/646, 6.2% [Watchman] vs. 43/676, 6.4% [Amplatzer]; hazard ratio (HR), 1.02; 95% confidence interval (CI), 0.66-1.58; P = 0.92] and safety (33/646, 5.1% vs. 30/676, 4.4%; HR, 0.57; 95% CI, 0.29-1.11; P = 0.10), as well as the combined hazard endpoint (69/646, 10.7% vs. 66/676, 9.8%; HR, 0.80; 95% CI, 0.55-1.12; P = 0.26) were similar for both groups. CONCLUSION: This study suggests comparable efficacy and safety of the Watchman and Amplatzer devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Alemanha/epidemiologia , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Suíça , Resultado do Tratamento
6.
Europace ; 22(6): 924-931, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32044994

RESUMO

AIMS: We report the collective European experience of percutaneous left atrial appendage (LAA) suture ligation using the recent generation LARIAT+ suture delivery device. METHODS AND RESULTS: A total of 141 patients with non-valvular atrial fibrillation and contraindication to oral anticoagulation (OAC), thrombo-embolic events despite OAC or electrical LAA isolation were enrolled at seven European hospitals to undergo LAA ligation. Patients were followed up by clinical visits and transoesophageal echocardiography (TOE) following LAA closure. Left atrial appendage ligation was completed in 138/141 patients (97.8%). Three patients did not undergo attempted deployment of the LARIAT device due to pericardial adhesion after previous epicardial ventricular tachycardia ablation (n = 1), a pericardial access-related complication (n = 1), and multiple posterior LAA lobes (n = 1). Serious 30-day procedural adverse events occurred in 4/141 patients (2.8%). There were two device-related LAA perforations (1.4%) not resulting in any corrective intervention as the LAA was completely sealed with the LARIAT. Minor adverse events occurred in 19 patients (13.5%), including two pericardial effusions due to procedure-related pericarditis requiring pericardiocentesis. Transoesophageal echocardiography was performed after LAA ligation in 103/138 patients (74.6%) after a mean of 181 ± 72 days. Complete LAA closure was documented in 100 patients (97.1%). Two patients (1.8% of patients with follow-up) experienced a transient ischaemic attack at 4 and 7 months follow-up, although there was no leak observed with TOE. There were two deaths during long-term follow-up which were both not device related. CONCLUSION: Initial experience with the LARIAT+ device demonstrates feasibility of LAA exclusion. Further larger prospective studies with longer follow-up are warranted.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Ligadura , Estudos Prospectivos , Suturas , Resultado do Tratamento
7.
Cardiovasc Diabetol ; 18(1): 142, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31672144

RESUMO

BACKGROUND: Hyperglycemia in the setting of an acute coronary syndrome (ACS) impacts short term outcomes, but little is known about longer term effects. We therefore designed this study to firstly determine the association between hyperglycemia and short term and longer term outcomes in patients presenting with ACS and secondly evaluate the prognostic role of diabetes, body mass index (BMI) and the novel biomarker Cyr61 on outcomes. METHODS: The prospective Special Program University Medicine-Acute Coronary Syndrome (SPUM-ACS) cohort enrolled 2168 patients with ACS between December 2009 and October 2012, of which 2034 underwent PCI (93.8%). Patients were followed up for 12 months. Events were independently adjudicated by three experienced cardiologists. Participants were recruited from four tertiary hospitals in Switzerland: Zurich, Geneva, Lausanne and Bern. Participants presenting with acute coronary syndromes and who underwent coronary angiography were included in the analysis. Patients were grouped according to history of diabetes (or HbA1c greater than 6%), baseline blood sugar level (BSL; < 6, 6-11.1 and > 11.1 mmol/L) and body mass index (BMI). The primary outcome was major adverse cardiac events (MACE) which was a composite of myocardial infarction, stroke and all-cause death. Secondary outcomes included the individual components of the primary endpoint, revascularisations, bleeding events (BARC classification) and cerebrovascular events (ischaemic or haemorrhagic stroke or TIA). RESULTS: Patients with hyperglycemia, i.e. BSL ≥ 11.1 mmol/L, had higher levels of C-reactive protein (CRP), white blood cell count (WBC), creatinine kinase (CK), higher heart rates and lower left ventricular ejection fraction (LVEF) and increased N-terminal pro-brain natriuretic peptide. At 30 days and 12 months, those with BSL ≥ 11.1 mmol/L had more MACE and death compared to those with BSL < 6.0 mmol/L or 6.0-11.1 mmol/L (HR-ratio 4.78 and 6.6; p < 0.001). The novel biomarker Cyr61 strongly associated with high BSL and STEMI and was independently associated with 1 year outcomes (HR 2.22; 95% CI 1.33-3.72; Tertile 3 vs. Tertile 1). CONCLUSIONS AND RELEVANCE: In this large, prospective, independently adjudicated cohort of in all comers ACS patients undergoing PCI, both a history of diabetes and elevated entry glucose was associated with inflammation and increased risk of MACE both at short and long-term. The mediators might involve increased sympathetic activation, inflammation and ischemia as reflected by elevated Cyr61 levels leading to larger levels of troponin and lower LVEF. Trial registration Clinical Trial Registration Number: NCT01000701. Registered October 23, 2009.


Assuntos
Síndrome Coronariana Aguda/sangue , Glicemia/metabolismo , Proteína Rica em Cisteína 61/sangue , Diabetes Mellitus/sangue , Hiperglicemia/sangue , Mediadores da Inflamação/sangue , Inflamação/sangue , Função Ventricular Esquerda , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/terapia , Idoso , Biomarcadores/sangue , Índice de Massa Corporal , Diabetes Mellitus/mortalidade , Diabetes Mellitus/terapia , Feminino , Hemoglobinas Glicadas , Humanos , Hiperglicemia/mortalidade , Hiperglicemia/terapia , Inflamação/mortalidade , Inflamação/terapia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Suíça , Fatores de Tempo
8.
Catheter Cardiovasc Interv ; 93(1): 141-148, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30269398

RESUMO

BACKGROUND: Post-procedural risk stratification based on renal function after trans aortic valve implantation (TAVI) was assessed by means of a modified age, creatinine, and ejection fraction (ACEF) score using the lowest glomerular filtration rate (GFR), obtained within 1 week after valve implantation. We refer to the score as ACEF-7 score. METHODS: The Zurich- and Cardiocentro Ticino TAVI-Cohorts comprised of 424, and 137 patients, who were not on hemodialysis and had already survived the first post-procedural week. Zurich patients were stratified into tertiles of ACEF-7 score (ACEF-7Low ≤ 2.45 (n = 138), ACEF-7Mid 2.46-4.38 (n = 142), and ACEF-7High ≥ 4.39 (n = 144) and compared for survival using KM curves. Euroscore II, Society of Thoracic Surgeons (STS), and ACEF were also calculated at baseline in all patients and assessed for prognostic significance in predicting the primary outcome of 1-year all-cause mortality using univariate and multivariate Cox regression models. Results were then confirmed in the Cardiocentro cohort. RESULTS: Six months (18.1% vs. 6.3% vs. 2.9% P < 0.001) and 1-year all-cause mortality (24.3% vs. 12.7% % vs. 5.8%, P < 0.001), as well as the composite of death or rehospitalization (35% vs. 20% vs. 11% P < 0.001) occurred significantly more frequently in the ACEF-7High compared to the other groups. Both Euroscore II and STS score were not predictors of mortality in our cohort. In a multivariate Cox regression model corrected for gender, Acute Kidney Injury, and baseline ACEF score, the ACEF-7 score was an independent predictor of 1-year all-cause mortality as a per point increment HR 1.512 [95% CI 1.227-1.862, P < 0.001] and as ACEF-7High (≥4.39); HR 5.541 [1.694-18.120]). In addition, the ACEF-7 tertiles showed a significant (P = 0.02) net reclassification improvement of 16% when compared to baseline tertiles of ACEF score, when assessing 1-year all-cause mortality. CONCLUSION: Post-procedural risk stratification using the simple ACEF-7 score significantly better predicted long-term outcome than commonly used risk-scores. Practical implications could include contrast sparing and renal protection in high-risk patients, emphasizing the importance of preventative measures.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Creatinina/sangue , Técnicas de Apoio para a Decisão , Rim/fisiopatologia , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
Eur Radiol ; 29(2): 975-984, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30019141

RESUMO

OBJECTIVES: To assess the value of pre-procedural computed tomography angiography (CTA) measurements of the suprahepatic inferior vena cava (IVC) to detect elevated central venous pressure (CVP) assessed by right heart catheterisation (RHC), and to predict post-procedural 1-year mortality in a cohort of patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: We retrospectively evaluated 408 consecutive patients undergoing CTA before TAVI between January 2011 and December 2014. Two hundred and five patients were included in the RHC cohort, who underwent RHC and CTA within ≤1 day prior to TAVI. Two hundred and three patients not fulfilling this requirement were included in the validation cohort. Measurements of the IVC were performed between diaphragm and right atrium on axial slices. Receiver operating characteristic (ROC) analyses, Kaplan-Meier analyses and Cox regression analyses were performed. RESULTS: In the RHC cohort, ROC curve analyses for IVC area measurements indicated an AUC of 0.77 (p < 0.001) to detect CVP ≥10mmHg and an area under the ROC curve (AUC) of 0.72 (p < 0.001) to predict 1-year mortality. An IVC area cut-off of ≥665 mm2 predicted 1-year mortality with a specificity of 84% and a sensitivity of 63%. Kaplan-Meier analysis showed that patients with an IVC area ≥665 mm2 had a significantly higher post-procedural 1-year mortality (38% versus 7%, log-rank p < 0.001) with a hazard ratio of 5.5 (95% CI, 2.2-13.6; p < 0.001). Applying this cut-off value to the validation cohort confirmed a significantly higher 1-year mortality after TAVI (34% versus 11%; log-rank p = 0.004) for patients with an IVC area ≥665 mm2. CONCLUSIONS: Pre-procedural enlargement of the suprahepatic IVC is a predictor of post-procedural 1-year mortality in patients evaluated for TAVI. KEY POINTS: • IVC measurements are moderate predictors of an elevated CVP in TAVI patients. • Pre-procedural IVC enlargement is a predictor of 1-year mortality after TAVI. • IVC enlargement is associated with right heart dysfunction in TAVI patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Veia Cava Inferior/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Pressão Venosa Central , Angiografia por Tomografia Computadorizada/métodos , Feminino , Fluoroscopia , Próteses Valvulares Cardíacas , Humanos , Estimativa de Kaplan-Meier , Masculino , Cuidados Pré-Operatórios/métodos , Prognóstico , Modelos de Riscos Proporcionais , Curva ROC , Sistema de Registros , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Veia Cava Inferior/patologia , Veia Cava Inferior/fisiopatologia
10.
Eur Heart J ; 39(8): 687-695, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29020413

RESUMO

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.


Assuntos
Oclusão Coronária/epidemiologia , Tomografia Computadorizada Multidetectores/métodos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Incidência , Masculino , Análise Multivariada , Sistema de Registros , Fatores de Risco
11.
Catheter Cardiovasc Interv ; 91(3): 533-539, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28500739

RESUMO

BACKGROUND: Feasibility of transfemoral (TF) transcathteter aortic valve replacement (TAVR) is limited by the smallest diameter, the calcification and tortuosity of the iliofemoral access vessels. The use of the Portico system without delivery sheath results in significantly lower profile delivery system compared to standard technique. We herein report our single center experience, feasibility and safety of such an approach. METHODS: The Portico valve was implanted sheathless in 81 high-risk patients with severe aortic stenosis utilizing percutaneous femoral access. Mean minimal diameter of the ileo-femoral arterial access was 7.06 ± 1.89 mm. In most cases a multidetector computed tomography was performed before the intervention to assess the feasibility of vascular access and for aortic annulus measurements. The vascular access site was preclosed using two ProGlide suture systems. RESULTS: Device implantation was successful 98.7% of patients. Valve recapturing and repositioning as well as valve-in-valve deployment was performed in only one case (1.2%). There were no infarctions, 2 strokes (2.4%) and 2 acute kidney failure (2.4%), 1 major vascular complication1 (1.2%) 4 major bleedings (4.9%), 11 conductions disturbances and relative pace-maker implantations (14.2%). The mean gradient decreased from 42.3 ± 17 to 6.3 ± 2.78 mm Hg. Paravalvular regurgitation as assessed by TTE at discharge was absent or trivial in 19 patients, mild in 60 and moderate 1. Thirty-day mortality was 2.4%. CONCLUSIONS: Sheathless use of the Portico valve is feasible and appears to be safe, with excellent rates of complications and mortality in the short-term. Such an approach has the potential to further expand feasibility of TF TAVR to patients with severe peripheral arterial disease. Feasibility in patients with smaller femoral access and more challenging anatomy has to be proven in further studies. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias/etiologia , Dados Preliminares , Punções , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Suíça , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
12.
Eur Heart J ; 38(9): 639-647, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26802134

RESUMO

Moderate-to-severe tricuspid regurgitation (TR) affects ∼1.6 million patients in the USA, of whom only 8000 undergo tricuspid surgery annually; this results in an extremely large number of untreated patients with significant TR. Therefore, there is a large unmet clinical need for patients with severe TR who are not referred for conventional surgery, mainly due to expected high surgical risk. Percutaneous procedures are an attractive alternative to surgery for patients deemed to be high-risk surgical candidates. Whereas over the past few years, the development and clinical use of percutaneous approaches to the aortic valve and mitral valve have been widespread, few data are available about the feasibility and the efficacy of the percutaneous tricuspid valve treatment. This review will explore the available technologies, which are today under evaluation and the preliminary clinical results.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência da Valva Tricúspide/cirurgia , Tecnologia Biomédica , Anuloplastia da Valva Cardíaca/instrumentação , Anuloplastia da Valva Cardíaca/métodos , Progressão da Doença , Humanos , Prognóstico , Instrumentos Cirúrgicos , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/patologia
13.
Catheter Cardiovasc Interv ; 89(6): 1100-1106, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27862874

RESUMO

BACKGROUND: The risk/benefit balance of transcatheter aortic valve implantation (TAVI) in patients with low-gradient aortic stenosis (LGAS) remains to be well defined. Aim of the study was to investigate the impact of LGAS in patients undergoing TAVI. METHODS: Medline, Cochrane Library, and Scopus were searched for articles reporting outcome of patients with LGAS undergoing TAVI. The primary endpoint was 12-months all-cause mortality and the secondary endpoint was 30-day all-cause mortality. Using event-rates as dependent variable, a meta-regression was performed to test for interaction between baseline clinical features (age, gender, diabetes mellitus, coronary artery disease, left ventricular ejection fraction (LVEF) and type of implanted valve) and transaortic gradient for the primary endpoint. RESULTS: Eight studies with a total of 12,589 patients were included. Almost one-third of the patients presented with LGAS (27.3%: 24.4-29.2). Median LVEF was 48% in patients with LGAS and 56% in patients with high-gradient AS. Patients with LGAS were more likely to have diabetes mellitus, previous coronary artery disease, higher mean Logistic EuroSCORE, and lower EF. At 12 (12-16.6) months, low transaortic gradient emerged as independently associated with all-cause death, both if evaluated as a dichotomous and continuous value (respectively OR 1.17; 1.11-1.23 and OR 1.02; 1-1.04, all CI 95%). Clinical variables, including EF did not affect this result. CONCLUSIONS: In a population of TAVI patients, LGAS appears to be independently related to dismal prognosis. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Razão de Chances , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
Eur Heart J ; 37(26): 2023-8, 2016 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26248568

RESUMO

Stroke is a devastating event for patients and their families. Paradoxical embolism through a patent foramen ovale (PFO) is a recognized cause of stroke. Percutaneous PFO closure is a simple and safe procedure. The debate on PFO closure is far from settled. This is, in part, due to the fact that the three published randomized controlled trials (RCTs) on PFO closure vs. medical therapy were negative regarding their primary endpoint; however, as-treated and per-protocol analyses as well as several meta-analyses report a benefit of PFO closure. In our opinion, PFO closure is underutilized and the results of the three RCTs are not adequately reflected in the current guidelines.


Assuntos
Forame Oval Patente , Embolia Paradoxal , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Prevenção Secundária , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Resultado do Tratamento
15.
Eur Heart J ; 37(47): 3495-3502, 2016 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-27161614

RESUMO

Paravalvular leak (PVL) occurs after both surgical and transcatheter valve replacement/implantation. It can lead to haemolysis, heart failure and may increase the risk of endocarditis. Percutaneous closure has significantly less morbidity than re-operation and is therefore often the therapy of choice. Percutaneous PVL closure can make an important difference for patients and can improve patient prognosis. These procedures can be intricate and larger case series and research is needed to further develop and improve these procedures.


Assuntos
Doenças das Valvas Cardíacas , Cateterismo Cardíaco , Insuficiência Cardíaca , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Falha de Prótese , Reoperação
16.
Catheter Cardiovasc Interv ; 88(4): 656-664, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27465268

RESUMO

OBJECTIVE: The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc. BACKGROUND: The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome. METHODS: Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA-neck. Transesophageal echocardiography was performed 1-6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure-related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow-up. RESULTS: Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA2 DS2 -Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow-up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0). CONCLUSIONS: No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of repositioning attempts in case of incomplete coverage does not seem to be warranted. Current findings need further confirmation in a larger scale clinical trial. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Intervalo Livre de Doença , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
17.
Curr Cardiol Rep ; 18(12): 129, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27796866

RESUMO

In the real world of mitral regurgitation, the patient selection process for MitraClip (Abbott, Abbott Park, IL, USA) to achieve optimal outcome has become a challenge. With the opening of the Endovascular Valve Edge-to-Edge Repair Study criteria, the implant experience was extended towards functional mitral regurgitation and anatomically more complex mitral pathologies in many centers worldwide. We provide a review of the current literature to identify an appropriate patient selection process for MitraClip therapy and suggest a simple two-dimensional decision-making algorithm.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Intervenção Coronária Percutânea , Técnicas de Sutura/instrumentação , Algoritmos , Tomada de Decisões , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/complicações , Seleção de Pacientes , Intervenção Coronária Percutânea/métodos , Próteses e Implantes , Desenho de Prótese , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 85(7): 1248-53, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25545281

RESUMO

OBJECTIVES: Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). BACKGROUND: Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. METHODS: Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. RESULTS: Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. CONCLUSIONS: Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN.


Assuntos
Injúria Renal Aguda/prevenção & controle , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Meios de Contraste/administração & dosagem , Implante de Prótese de Valva Cardíaca/métodos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Meios de Contraste/efeitos adversos , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Injeções , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Radiografia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
20.
Catheter Cardiovasc Interv ; 85(7): 1240-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25511571

RESUMO

OBJECTIVES: We studied the prognostic value of plasma N-terminal pro-brain natriuretic peptide (NT-proBNP)-ratio, which is independent of individual cutoff levels, in predicting mortality in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Elevated levels of natriuretic peptides are associated with adverse outcomes across a wide spectrum of cardiovascular diseases. However, cutoff values differ according to age, gender, and body weight. METHODS: 244 TAVR patients with preprocedural NT-proBNP levels were analyzed, and the predictive value of NT-proBNP-ratio (measured NT-proBNP/maximal normal NT-proBNP values specific for age and gender) on all-cause-mortality was assessed in a multivariate model. RESULTS: Median NT-proBNP-ratio was 4.2 [IQR 1.8-9.7]. All-cause mortality at 30 days was 3.4% in patients with less than median NT-proBNP-ratio, and 14.0% in patients with more than median NT-proBNP-ratio (P=0.02). All-cause mortality at 1 year was 8.5% in patients with less than median NT-proBNP-ratio, and 32.1% in those with more than median NT-proBNP-ratio (P=0.001). Cumulative survival declined with increasing quartiles of NT-proBNP-ratio (log rank P=0.001). All patients with a NT-proBNP-ratio below 1.5 survived at 1-year follow-up. In ROC analysis, NT-proBNP-ratio significantly predicted 30-day (AUC=0.72; P=0.002) and 1-year all-cause mortality (AUC=0.72; P<0.001). By multivariate Cox regression analysis, NT-proBNP-ratio, chronic obstructive pulmonary disease, and serum creatinine were the only independent predictors of all-cause mortality. CONCLUSIONS: Elevated NT-proBNP-ratio was associated with increased short- and long-term mortality after TAVR, and independently predicted all-cause mortality. NT-proBNP-ratio should be considered in the risk stratification of patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Área Sob a Curva , Biomarcadores/sangue , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Causas de Morte , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Suíça , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa