1.
Biomed Eng Online ; 16(1): 60, 2017 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-28526082

RESUMO

BACKGROUND: Pulse oximeters continuously monitor arterial oxygen saturation. Continuous monitoring of venous oxygen saturation (SvO2) would enable real-time assessment of tissue oxygen extraction (O2E) and perfusion changes leading to improved diagnosis of clinical conditions, such as sepsis. METHODS: This study presents the proof of concept of a novel pulse oximeter method that utilises the compliance difference between arteries and veins to induce artificial respiration-like modulations to the peripheral vasculature. These modulations make the venous blood pulsatile, which are then detected by a pulse oximeter sensor. The resulting photoplethysmograph (PPG) signals from the pulse oximeter are processed and analysed to develop a calibration model to estimate regional venous oxygen saturation (SpvO2), in parallel to arterial oxygen saturation estimation (SpaO2). A clinical study with healthy adult volunteers (n = 8) was conducted to assess peripheral SvO2 using this pulse oximeter method. A range of physiologically realistic SvO2 values were induced using arm lift and vascular occlusion tests. Gold standard, arterial and venous blood gas measurements were used as reference measurements. Modulation ratios related to arterial and venous systems were determined using a frequency domain analysis of the PPG signals. RESULTS: A strong, linear correlation (r 2  = 0.95) was found between estimated venous modulation ratio (RVen) and measured SvO2, providing a calibration curve relating measured RVen to venous oxygen saturation. There is a significant difference in gradient between the SpvO2 estimation model (SpvO2 = 111 - 40.6*R) and the empirical SpaO2 estimation model (SpaO2 = 110 - 25*R), which yields the expected arterial-venous differences. Median venous and arterial oxygen saturation accuracies of paired measurements between pulse oximeter estimated and gold standard measurements were 0.29 and 0.65%, respectively, showing good accuracy of the pulse oximeter system. CONCLUSIONS: The main outcome of this study is the proof of concept validation of a novel pulse oximeter sensor and calibration model to assess peripheral SvO2, and thus O2E, using the method used in this study. Further validation, improvement, and application of this model can aid in clinical diagnosis of microcirculation failures due to alterations in oxygen extraction.


Assuntos
Oximetria , Oxigênio/metabolismo , Fotopletismografia , Veias/metabolismo , Adulto , Circulação Sanguínea , Humanos , Masculino , Oximetria/instrumentação , Fotopletismografia/instrumentação , Adulto Jovem
2.
Med Biol Eng Comput ; 56(9): 1715-1729, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29524117

RESUMO

Finite element (FE) models are increasingly used to validate experimental data in breast cancer. This research constructed a biomechanical FE model for breast shaped phantoms used to develop and validate a mechanical vibration based screening system. Such models do not currently exist but would enhance development of this screening technology. Three phantoms were modelled: healthy, with 10 and 20 mm inclusions. The overall goal was to create models with enough accuracy to replace experimental phantoms in providing data to optimize diagnostic algorithms for digital image-based elasto-tomography (DIET) screening technologies. FE model results were validating against experimental DIET phantom data for over 4000 collected points on each model and phantom using cross-correlation coefficients between experimental simulated data and direct comparison. Results showed good to strong correlation ranging from 0.7 to 1.0 in all cases with over 90% having a value over 0.9. Magnitudes for each frame of the dynamic response also matched well, indicating that the material properties and geometry were accurate enough to provide this level of correlation. These results justify the use of FE model generated data for in silico diagnostic algorithm development testing. The overall modelling and validation approach is not overly complex, and thus generalizable to similar problems using mechanical properties of silicone phantoms, and might be extensible to human cases with further work. Graphical abstract Validate that dynamic displacements show that the model can be used in place of phantoms for rapid development of diagnostic algorithms that use surface motion to detect underlying mechanical properties.


Assuntos
Neoplasias da Mama/diagnóstico , Técnicas de Imagem por Elasticidade , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador , Tomografia , Feminino , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
J Diabetes Sci Technol ; 10(6): 1335-1343, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27301981

RESUMO

BACKGROUND: Continuous glucose monitoring (CGM) devices, with their 1-5 min measurement interval, allow blood glucose (BG) concentration dynamics to be captured more frequently and less invasively than traditional BG measures. One cohort CGM could provide insight is athletes. This study investigates what impact their heightened energy expenditure and dietary intake may have on their ability to achieve optimal BG. METHODS: Ten subelite athletes (resting HR<60 bpm, training>6 hrs per week) were recruited. Two Ipro2 CGM devices (Medtronic Minimed, Northridge, CA) were inserted into the abdomen and remained in place for ~6 days. Time in band was calculated as the percentage of CGM BG measurements with in the 4.0-6.0 mmol/L. Fasting glucose was calculated using CGM calibration BG measurements and postprandial glucose response was also calculated using the CGM values. RESULTS: 4/10 athletes studied spent more than 70% of the total monitoring time above 6.0 mmol/L even with the 2-hour period after meals is excluded. Fasting BG was also in the ADA defined prediabetes range for 3/10 athletes. Only 1 participant spent substantial time below 4.0 mmol/L which was largely due to significantly lower energy intake compared to recommendations. CONCLUSIONS: Contrary to expectations high BG appears to be more of a concern for athletes then low BG even in those with the highest energy expenditure and consuming below the recommended carbohydrate intake. This study warrants further investigation on the recommended diets and the BG of athletes to better determine the causes and impact of this hyperglycemia on overall athlete health.


Assuntos
Atletas , Glicemia/análise , Hiperglicemia/sangue , Hipoglicemia/sangue , Adulto , Carboidratos da Dieta , Feminino , Humanos , Masculino , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-26737792

RESUMO

The End-Systolic Pressure-Volume Relation (ESPVR) is generally modelled as a linear relationship between P and V as cardiac reflexes, such as the baroreflex, are typically suppressed in experiments. However, ESPVR has been observed to behave in a curvilinear fashion when cardiac reflexes are not suppressed, suggesting the curvilinear function may be more clinically appropriate. Data was gathered from 41 vena cava occlusion manoeuvres performed experimentally at a variety of PEEPs across 6 porcine specimens, and ESPVR determined for each pig. An exponential model of ESPVR was found to provide a higher correlation coefficient than a linear model in 6 out of 7 cases, and a lower Akaike Information Criterion (AIC) value in all cases. Further, the exponential ESPVR provided positive V0 values in a physiological range in 6 out of 7 cases analysed, while the linear ESPVR produced positive V0 values in only 3 out of 7 cases, suggesting linear extrapolation of ESPVR to determine V0 may be flawed.


Assuntos
Pressão Sanguínea/fisiologia , Modelos Cardiovasculares , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Animais , Suínos