Magn Reson Med ; 91(2): 842-849, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37849021

RESUMO

PURPOSE: To develop a flexible, lightweight, and multi-purpose integrated parallel reception, excitation, and shimming (iPRES) coil array that can conform to the subject's anatomy and perform MR imaging and localized B0 shimming in different anatomical regions with a high SNR, shimming performance, ease of positioning, and subject comfort. METHODS: A four-channel flexible iPRES coil array was constructed by enabling RF and direct currents to flow on the same flexible coil elements for imaging and shimming, respectively. Shimming experiments were performed with the coil array wrapped around the knee or neck of healthy subjects to demonstrate its high shimming performance and versatility. Additionally, its SNR and shimming performance in the knee were compared to those obtained with the coil array wrapped around a larger rigid tube designed to fit most knee sizes. RESULTS: Shimming with the coil array wrapped around the knee or neck resulted in an average reduction in B0 RMSE of 50.1% and 40.5% relative to first-order and second-order spherical harmonic shimming, respectively, and substantially reduced distortions in DWI images. In contrast, shimming the knee with the coil array wrapped around the rigid tube only provided a 29.6% reduction in B0 RMSE, whereas the SNR was reduced by 58.7%. CONCLUSION: The flexible iPRES coil array can conform to different anatomical regions and perform imaging and localized B0 shimming with a higher SNR, shimming performance, ease of positioning, and comfort compared to a rigid iPRES coil array, which should be valuable for many applications throughout the human body.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Articulação do Joelho/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
2.
Magn Reson Med ; 89(6): 2471-2484, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36695296

RESUMO

PURPOSE: Coil arrays are connected to the main MRI system with long, shielded coaxial cables. RF coupling of these cables to the main transmit coil can cause high shield currents, which pose risks of heating and RF burns. High-blocking resonant RF traps are placed at distinct positions along cables to mitigate these currents. Traditional traps are designed to be stiff to avoid changes in their resonant frequency, hindering the overall system flexibility. Instead of using a few high-blocking traps, we propose the use of caterpillar traps-a distributed system of small, elastic traps that cover the full length of cables. METHODS: We leverage an array of resonant toroids as traps, forming a caterpillar-like structure whereby bending only impacts individual traps minimally. Benchtop measurements are used to determine the blocking of caterpillar traps and show their robustness to bending. We also compare an anterior array system cable covered with caterpillar traps to a commercial cable with B1 + and heating measurements. RESULTS: Benchtop experiments with caterpillar traps demonstrate high robustness to bending. B1 + mapping experiments of an anterior array cable show improved blocking and flexibility compared to a commercial cable. CONCLUSION: Caterpillar traps provide sufficient attenuation to shield currents while allowing cable flexibility. Our distributed design can provide high blocking efficiency at different positions and orientations, even in cases where commercial cable traps cannot.


Assuntos
Imageamento por Ressonância Magnética , Desenho de Equipamento , Imagens de Fantasmas
3.
Sensors (Basel) ; 23(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37688046

RESUMO

Flexible and stretchable radiofrequency coils for magnetic resonance imaging represent an emerging and rapidly growing field. The main advantage of such coil designs is their conformal nature, enabling a closer anatomical fit, patient comfort, and freedom of movement. Previously, we demonstrated a proof-of-concept single element stretchable coil design with a self-tuning smart geometry. In this work, we evaluate the feasibility of scaling this coil concept to a multi-element coil array and the associated engineering and manufacturing challenges. To this goal, we study a dual-channel coil array using full-wave simulations, bench testing, in vitro, and in vivo imaging in a 3 T scanner. We use three fabrication techniques to manufacture dual-channel receive coil arrays: (1) single-layer casting, (2) double-layer casting, and (3) direct-ink-writing. All fabricated arrays perform equally well on the bench and produce similar sensitivity maps. The direct-ink-writing method is found to be the most advantageous fabrication technique for fabrication speed, accuracy, repeatability, and total coil array thickness (0.6 mm). Bench tests show excellent frequency stability of 128 ± 0.6 MHz (0% to 30% stretch). Compared to a commercial knee coil array, the stretchable coil array is more conformal to anatomy and provides 50% improved signal-to-noise ratio in the region of interest.


Assuntos
Comércio , Engenharia , Humanos , Articulação do Joelho , Metais , Movimento
4.
Magn Reson Med ; 88(2): 1002-1014, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35468243

RESUMO

PURPOSE: To develop a wireless integrated parallel reception, excitation, and shimming (iPRES-W) coil array for simultaneous imaging and wireless localized B0 shimming, and to demonstrate its ability to correct for distortions in DTI of the spinal cord in vivo. METHODS: A 4-channel coil array was modified to allow an RF current at the Larmor frequency and a direct current to flow on each coil element, enabling imaging and localized B0 shimming, respectively. One coil element was further modified to allow additional RF currents within a wireless communication band to flow on it to wirelessly control the direct currents for shimming, which were supplied from a battery pack within the scanner bore. The RF signals for imaging were transferred via conventional wired connections. Experiments were conducted to evaluate the RF, B0 shimming, and wireless performance of this coil design. RESULTS: The coil modifications did not degrade the SNR. Wireless localized B0 shimming with the iPRES-W coil array substantially reduced the B0 RMSE (-57.5% on average) and DTI distortions in the spinal cord. The antenna radiation efficiency, antenna gain pattern, and battery power consumption of an iPRES-W coil measured in an anechoic chamber were minimally impacted by the introduction of a saline phantom representing tissue. CONCLUSION: The iPRES-W coil array can perform imaging and wireless localized B0 shimming of the spinal cord with no SNR degradation, with minimal change in wireless performance and without any scanner modifications or additional antenna systems within the scanner bore.


Assuntos
Medula Cervical , Imageamento por Ressonância Magnética , Encéfalo , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Medula Espinal/diagnóstico por imagem
5.
NMR Biomed ; 35(12): e4802, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35834176

RESUMO

Lack of a body-sized, bore-mounted, radiofrequency (RF) body coil for ultrahigh field (UHF) magnetic resonance imaging (MRI) is one of the major drawbacks of UHF, hampering the clinical potential of the technology. Transmit field (B1 ) nonuniformity and low specific absorption rate (SAR) efficiencies in UHF MRI are two challenges to be overcome. To address these problems, and ultimately provide a pathway for the full clinical potential of the modality, we have designed and simulated two-dimensional cylindrical high-pass ladder (2D c-HPL) architectures for clinical bore-size dimensions, and demonstrated a simplified proof of concept with a head-sized prototype at 7 T. A new dispersion relation has been derived and electromagnetic simulations were used to verify coil modes. The coefficient of variation (CV) for brain, cerebellum, heart, and prostate tissues after B1 + shimming in silico is reported and compared with previous works. Three prototypes were designed in simulation: a head-sized, body-sized, and long body-sized coil. The head-sized coil showed a CV of 12.3%, a B1 + efficiency of 1.33 µT/√W, and a SAR efficiency of 2.14 µT/√(W/kg) for brain simulations. The body-sized 2D c-HPL coil was compared with same-sized transverse electromagnetic (TEM) and birdcage coils in silico with a four-port circularly polarized mode excitation. Improved B1 + uniformity (26.9%) and SAR efficiency (16% and 50% better than birdcage and TEM coils, respectively) in spherical phantoms was observed. We achieved a CV of 12.3%, 4.9%, 16.7%, and 2.8% for the brain, cerebellum, heart, and prostate, respectively. Preliminary imaging results for the head-sized coil show good agreement between simulation and experiment. Extending the 1D birdcage coil concept to 2D c-HPLs provides improved B1 + uniformity and SAR efficiency.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Cabeça , Encéfalo/diagnóstico por imagem
6.
Magn Reson Med ; 85(3): 1561-1570, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32926448

RESUMO

PURPOSE: To measure the transverse relaxation time ( T 2 ∗ ) and apparent diffusion coefficient (ADC) of 19 F-C3 F8 gas in vivo in human lungs at 1.5T and 3T, and to determine the representative distribution of values of these parameters in a cohort of healthy volunteers. METHODS: Mapping of ADC at lung inflation levels of functional residual capacity (FRC) and total lung capacity (TLC) was performed with inhaled 19 F-C3 F8 (eight subjects) and 129 Xe (six subjects) at 1.5T. T 2 ∗ mapping with 19 F-C3 F8 was performed at 1.5T (at FRC and TLC) for 8 subjects and at 3T (at TLC for seven subjects). RESULTS: At both FRC and TLC, the 19 F-C3 F8 ADC was smaller than the free diffusion coefficient demonstrating airway microstructural diffusion restriction. From FRC to TLC, the mean ADC significantly increased from 1.56 mm2 /s to 1.83 mm2 /s (P = .0017) for 19 F-C3 F8, and from 2.49 mm2 /s to 3.38 mm2 /s (P = .0015) for 129 Xe. The posterior-to-anterior gradient in ADC for FRC versus TLC in the superior half of the lungs was measured as 0.0308 mm2 /s per cm versus 0.0168 mm2 /s per cm for 19 F-C3 F8 and 0.0871 mm2 /s per cm versus 0.0326 mm2 /s per cm for 129 Xe. A consistent distribution of 19 F-C3 F8 T 2 ∗ values was observed in the lungs, with low values observed near the diaphragm and large pulmonary vessels. The mean T 2 ∗ across volunteers was 4.48 ms at FRC and 5.33 ms at TLC for 1.5T, and 3.78 ms at TLC for 3T. CONCLUSION: In this feasibility study, values of physiologically relevant parameters of lung microstructure measurable by MRI ( T 2 ∗ , and ADC) were established for C3 F8 in vivo lung imaging in healthy volunteers.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética , Voluntários Saudáveis , Humanos , Pulmão/diagnóstico por imagem , Testes de Função Respiratória
7.
Magn Reson Med ; 86(6): 3373-3381, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34268802

RESUMO

PURPOSE: This study describes the development and testing of an asymmetrical xenon-129 (129 Xe) birdcage radiofrequency (RF) coil for 129 Xe lung ventilation imaging at 1.5 Tesla, which allows proton (1 H) system body coil transmit-receive functionality. METHODS: The 129 Xe RF coil is a whole-body asymmetrical elliptical birdcage constructed without an outer RF shield to enable 1 H imaging. B1+ field homogeneity and flip angle mapping of the 129 Xe birdcage RF coil and 1 H system body RF coil with the 129 Xe RF coil in situ were evaluated in the MR scanner. The functionality of the 129 Xe birdcage RF coil was demonstrated through hyperpolarized 129 Xe lung ventilation imaging with the birdcage in both transceiver configuration and transmit-only configuration when combined with an 8-channel 129 Xe receive-only RF coil array. The functionality of 1 H system body coil with the 129 Xe RF coil in situ was demonstrated by acquiring coregistered 1 H lung anatomical MR images. RESULTS: The asymmetrical birdcage produced a homogeneous B1+ field (±10%) in agreement with electromagnetic simulations. Simulations indicated an optimal detuning configuration with 4 diodes. The obtained g-factor of 1.4 for acceleration factor of R = 2 indicates optimal array configuration. Coregistered 1 H anatomical images from the system body coil along with 129 Xe lung images demonstrated concurrent and compatible arrangement of the RF coils. CONCLUSION: A large asymmetrical birdcage for homogenous B1+ transmission with high sensitivity reception for 129 Xe lung MRI at 1.5 Tesla has been demonstrated. The unshielded asymmetrical birdcage design enables 1 H structural lung MR imaging in the same exam.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Desenho de Equipamento , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Prótons , Tórax
8.
AJR Am J Roentgenol ; 216(2): 552-559, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33236945

RESUMO

OBJECTIVE. The Adaptive Image Receive (AIR) radiofrequency coil is an emergent technology that is lightweight and flexible and exhibits electrical characteristics that overcome many of the limitations of traditional rigid coil designs. The purpose of this study was to apply the AIR coil for whole-brain imaging and compare the performance of a prototype AIR coil array with the performance of conventional head coils. SUBJECTS AND METHODS. A phantom and 15 healthy adult participants were imaged. A prototype 16-channel head AIR coil was compared with conventional 8-and 32-channel head coils using clinically available MRI sequences. During consensus review, two board-certified neuroradiologists graded the AIR coil compared with an 8-channel coil and a 32-channel coil on a 5-point ordinal scale in multiple categories. One- and two-sided Wilcoxon signed rank tests were performed. Noise covariance matrices and geometry factor (g-factor) maps were calculated. RESULTS. The signal-to-noise ratio, structural sharpness, and overall image quality scores of the prototype 16-channel AIR coil were better than those of the 8-channel coil but were not as good as those of the 32-channel coil. Noise covariance matrices showed stable performance of the AIR coil across participants. The median g-factors for the 16-channel AIR coil were, overall, less than those of the 8-channel coil but were greater than those of the 32-channel coil. CONCLUSION. On average, the prototype 16-channel head AIR coil outperformed a conventional 8-channel head coil but did not perform as well as a conventional 32-channel head coil. This study shows the feasibility of the novel AIR coil technology for imaging the brain and provides insight for future coil design improvements.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neuroimagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Razão Sinal-Ruído , Adulto Jovem
9.
Magn Reson Med ; 84(4): 2262-2277, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32281139

RESUMO

PURPOSE: To firstly improve the attainable image SNR of 19 F and 1 H C3 F8 lung imaging at 1.5 tesla using an 8-element transmit/receive (Tx/Rx) flexible vest array combined with a 6-element Rx-only array, and to secondly evaluate microelectromechanical systems for switching the array elements between the 2 resonant frequencies. METHODS: The Tx efficiency and homogeneity of the 8-element array were measured and simulated for 1 H imaging in a cylindrical phantom and then evaluated for in vivo 19 F/1 H imaging. The added improvement provided by the 6-element Rx-only array was quantified through simulation and measurement and compared to the ultimate SNR. It was verified through the measurement of isolation that microelectromechanical systems switches provided broadband isolation of Tx/Rx circuitry such that the 19 F tuned Tx/Rx array could be effectively used for both 19 F and 1 H nuclei. RESULTS: For 1 H imaging, the measured Tx efficiency/homogeneity (mean ± percent SD; 6.79µT/kW±26% ) was comparable to that simulated ( 7.57µT/kW±20% ). The 6 additional Rx-only loops increased the mean Rx sensitivity when compared to the 8-element array by a factor of 1.41× and 1.45× in simulation and measurement, respectively. In regions central to the thorax, the simulated SNR of the 14-element array achieves ≥70% of the ultimate SNR when including noise from the matching circuits and preamplifiers. A measured microelectromechanical systems switching speed of 12 µs and added minimum 22 dB of isolation between Tx and Rx were sufficient for Tx/Rx switching in this application. CONCLUSION: The described single-tuned array driven at 19 F and 1 H, utilizing microelectromechanical systems technology, provides excellent results for 19 F and 1 H dual-nuclear lung ventilation imaging.


Assuntos
Sistemas Microeletromecânicos , Desenho de Equipamento , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
10.
J Magn Reson Imaging ; 51(1): 90-97, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31081564

RESUMO

BACKGROUND: There has been recent interest in nonproton MRI including hyperpolarized carbon-13 (13 C) imaging. Prostate cancer has been shown to have a higher tissue sodium concentration (TSC) than normal tissue. Sodium (23 Na) and 13 C nuclei have a frequency difference of only 1.66 MHz at 3T, potentially enabling 23 Na imaging with a 13 C-tuned coil and maximizing the metabolic information obtained from a single study. PURPOSE: To compare TSC measurements from a 13 C-tuned endorectal coil to those quantified with a dedicated 23 Na-tuned coil. STUDY TYPE: Prospective. POPULATION: Eight patients with biopsy-proven, intermediate/high risk prostate cancer imaged prior to prostatectomy. SEQUENCE: 3T MRI with separate dual-tuned 1 H/23 Na and 1 H/13 C endorectal receive coils to quantify TSC. ASSESSMENT: Regions-of-interest for TSC quantification were defined for normal peripheral zone (PZ), normal transition zone (TZ), and tumor, with reference to histopathology maps. STATISTICAL TESTS: Two-sided Wilcoxon rank sum with additional measures of correlation, coefficient of variation, and Bland-Altman plots to assess for between-test differences. RESULTS: Mean TSC for normal PZ and TZ were 39.2 and 33.9 mM, respectively, with the 23 Na coil and 40.1 and 36.3 mM, respectively, with the 13 C coil (P = 0.22 and P = 0.11 for the intercoil comparison, respectively). For tumor tissue, there was no statistical difference between the overall mean tumor TSC measured with the 23 Na coil (41.8 mM) and with the 13 C coil (46.6 mM; P = 0.38). Bland-Altman plots showed good repeatability for tumor TSC measurements between coils, with a reproducibility coefficient of 9 mM; the coefficient of variation between the coils was 12%. The Pearson correlation coefficient for TSC between coils for all measurements was r = 0.71 (r2 = 0.51), indicating a strong positive linear relationship. The mean TSC within PZ tumors was significantly higher compared with normal PZ for both the 23 Na coil (45.4 mM; P = 0.02) and the 13 C coil (49.4 mM; P = 0.002). DATA CONCLUSION: We demonstrated the feasibility of using a carbon-tuned coil to quantify TSC, enabling dual metabolic information from a single coil. This approach could make the acquisition of both 23 Na-MRI and 13 C-MRI feasible in a single clinical imaging session. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:90-97.


Assuntos
Isótopos de Carbono , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Isótopos de Sódio , Sódio/metabolismo , Idoso , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/metabolismo , Reprodutibilidade dos Testes
11.
Radiology ; 291(1): 180-185, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30806599

RESUMO

Background Screen-printed MRI coil technology may reduce the need for bulky and heavy housing of coil electronics and may provide a better fit to patient anatomy to improve coil performance. Purpose To assess the performance and caregiver and clinician acceptance of a pediatric-sized screen-printed flexible MRI coil array as compared with conventional coil technology. Materials and Methods A pediatric-sized 12-channel coil array was designed by using a screen-printing process. Element coupling and phantom signal-to-noise ratio (SNR) were assessed. Subjects were scanned by using the pediatric printed array between September and November 2017; results were compared with three age- and sex-matched historical control subjects by using a commercial 32-channel cardiac array at 3 T. Caregiver acceptance was assessed by asking nurses, technologists, anesthesiologists, and subjects or parents to rate their coil preference. Diagnostic quality of the images was evaluated by using a Likert scale (5 = high image quality, 1 = nondiagnostic). Image SNR was evaluated and compared. Results Twenty study participants were evaluated with the screen-printed coil (age range, 2 days to 12 years; 11 male and nine female subjects). Loaded pediatric phantom testing yielded similar noise covariance matrices and only slightly degraded SNR for the printed coil as compared with the commercial coil. The caregiver acceptance survey yielded a mean score of 4.1 ± 0.6 (scale: 1, preferred the commercial coil; 5, preferred the printed coil). Diagnostic quality score was 4.5 ± 0.6. Mean image SNR was 54 ± 49 (paraspinal muscle), 78 ± 51 (abdominal wall muscle), and 59 ± 35 (psoas) for the printed coil, as compared with 64 ± 55, 65 ± 48, and 57 ± 43, respectively, for the commercial coil; these SNR differences were not statistically significant (P = .26). Conclusion A flexible screen-printed pediatric MRI receive coil yields adequate signal-to-noise ratio in phantoms and pediatric study participants, with similar image quality but higher preference by subjects and their caregivers when compared with a conventional MRI coil. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Lamb in this issue.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Impressão/métodos , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/normas , Masculino , Imagens de Fantasmas , Controle de Qualidade , Razão Sinal-Ruído
12.
Magn Reson Med ; 81(2): 1130-1142, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30387911

RESUMO

PURPOSE: To optimize 19 F imaging pulse sequences for perfluoropropane (C3 F8 ) gas human lung ventilation MRI considering intrinsic in vivo relaxation parameters at both 1.5T and 3T. METHODS: Optimization of the imaging parameters for both 3D spoiled gradient (SPGR) and steady-state free precession (SSFP) 19 F imaging sequences with inhaled 79% C3 F8% and 21% oxygen was performed. Phantom measurements were used to validate simulations of SNR. In vivo parameter mapping and sequence optimization and comparison was performed by imaging the lungs of a healthy adult volunteer. T1 and T2* mapping was performed in vivo to optimize sequence parameters for in vivo lung MRI. The performance of SSFP and SPGR was then evaluated in vivo at 1.5T and 3T. RESULTS: The in vivo T2* of C3 F8 was shown to be dependent upon lung inflation level (2.04 ms ± 36% for residual volume and 3.14 ms ± 28% for total lung capacity measured at 3T), with lower T2* observed near the susceptibility interfaces of the diaphragm and around pulmonary blood vessels. Simulation and phantom measurements indicate that a factor of ~2-3 higher SNR can be achieved with SSFP when compared with optimized SPGR. In vivo lung imaging showed a 1.7 factor of improvement in SNR achieved at 1.5T, while the theoretical improvement at 3T was not attained due to experimental SAR constraints, shorter in vivo T1 , and B0 inhomogeneity. CONCLUSION: SSFP imaging provides increased SNR in lung ventilation imaging of C3 F8 demonstrated at 1.5T with optimized SSFP similar to the SNR that can be obtained at 3T with optimized SPGR.


Assuntos
Flúor/química , Fluorocarbonos/química , Isótopos/química , Pulmão/diagnóstico por imagem , Adulto , Simulação por Computador , Meios de Contraste , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Oxigênio , Imagens de Fantasmas , Respiração , Razão Sinal-Ruído
13.
Magn Reson Med ; 81(3): 2176-2183, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30277273

RESUMO

PURPOSE: An innovative radio-frequency (RF) coil design that allows RF currents both at the Larmor frequency and in a wireless communication band to flow on the same coil is proposed to enable simultaneous MRI signal reception and wireless data transfer, thereby minimizing the number of wired connections in the scanner without requiring any modifications or additional hardware within the scanner bore. METHODS: As a first application, the proposed integrated RF/wireless coil design was further combined with an integrated RF/shim coil design to perform not only MR image acquisition and wireless data transfer, but also localized B0 shimming with a single coil. Proof-of-concept phantom experiments were conducted with such a coil to demonstrate its ability to simultaneously perform these three functions, while maintaining the RF performance, wireless data integrity, and B0 shimming performance. RESULTS: Performing wirelessly controlled shimming of localized B0 inhomogeneities with the coil substantially reduced the B0 root-mean-square error (>70%) and geometric distortions in echo-planar images without degrading the image quality, signal-to-noise ratio (<1.7%), or wireless data throughput (maximum variance = 0.04 Mbps) of the coil. CONCLUSIONS: The RF/wireless coil design can provide a solution for wireless data transfer that can be easily integrated into existing MRI scanners for a variety of applications.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Tecnologia sem Fio , Algoritmos , Calibragem , Simulação por Computador , Imagem Ecoplanar/métodos , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Razão Sinal-Ruído , Software
14.
IEEE Trans Microw Theory Tech ; 67(5): 1717-1726, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31423023

RESUMO

In magnetic resonance imaging (MRI), wearable wireless receive coil arrays are a key technology goal. An MRI compatible wireless power transfer (WPT) system will be needed to realize this technology. An MRI WPT system must withstand the extreme electromagnetic environment of the scanner and cannot degrade MRI image quality. Here, a WPT system is developed for operation in MRI scanners using new microelectromechanical RF switch (RF MEMs) technology. The WPT system includes a class-E power amplifier, RF MEMs automated impedance matching, a primary coil array employing RF MEMs power steering, and a flexible secondary coil with class E rectification. To adapt WPT technology to MRI, techniques are developed for operation at high magnetic field, and to mitigate the RF interactions between the scanner and WPT system. A major challenge was the identification and suppression of noise and harmonic interference, by gating, filtering, and rectifier topologies. The system can achieve 63% efficiency while exceeding 13 W delivery over a coil distance of 3.5 cm. For continuous WPT beyond 5W, added filters and full-wave class E rectification lowers harmonic generation at some cost to efficiency, while image SNR reaches about 32% of the ideal. RF-gated WPT, which interrupts power transfer in the MRI signal acquisition interval, achieves SNR performance to within 1 dB of the ideal. With further refinement, the inclusion of WPT technology in MRI scanners appears completely feasible.

15.
Magn Reson Med ; 80(4): 1746-1753, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29524235

RESUMO

PURPOSE: To evaluate the performance of micro-electromechanical systems (MEMS) switches against PIN diodes for switching a dual-tuned RF coil between 19 F and 1 H resonant frequencies for multi-nuclear lung imaging. METHODS: A four-element fixed-phase and amplitude transmit-receive RF coil was constructed to provide homogeneous excitation across the lungs, and to serve as a test system for various switching methods. The MR imaging and RF performance of the coil when switched between the 19 F and 1 H frequencies using MEMS switches, PIN diodes and hardwired configurations were compared. RESULTS: The performance of the coil with MEMS or PIN diode switching was comparable in terms of RF measurements, transmit efficiency and image SNR on both 19 F and 1 H nuclei. When the coil was not switched to the resonance frequency of the respective nucleus being imaged, reductions in the transmit efficiency were observed of 32% at the 19 F frequency and 12% at the 1 H frequency. The coil provides transmit field homogeneity of ±12.9% at the 1 H frequency and ±14.4% at the 19 F frequency in phantoms representing the thorax with the air space of the lungs filled with perfluoropropane gas. CONCLUSION: MEMS and PIN diodes were found to provide comparable performance in on-state configuration, while MEMS were more robust in off-state high-powered operation (>1 kW), providing higher isolation and requiring a lower DC switching voltage than is needed for reverse biasing of PIN diodes. In addition, clear benefits of switching between the 19 F and 1 H resonances were demonstrated, despite the proximity of their Larmor frequencies.


Assuntos
Imagem por Ressonância Magnética de Flúor-19/instrumentação , Sistemas Microeletromecânicos/instrumentação , Adulto , Desenho de Equipamento , Imagem por Ressonância Magnética de Flúor-19/métodos , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Masculino , Imagens de Fantasmas
16.
Magn Reson Med ; 80(1): 371-379, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29148102

RESUMO

PURPOSE: Integrated parallel reception, excitation, and shimming coil arrays with N shim loops per radio-frequency (RF) coil element (iPRES(N)) allow an RF current and N direct currents (DC) to flow in each coil element, enabling simultaneous reception/excitation and shimming of highly localized B0 inhomogeneities. The purpose of this work was to reduce the cost and complexity of this design by reducing the number of DC power supplies required by a factor N, while maintaining a high RF and shimming performance. METHODS: In the proposed design, termed adaptive iPRES(N) (iPRES(N)-A), each coil element only requires one DC power supply, but uses microelectromechanical systems switches to adaptively distribute the DC current into the appropriate shim loops to generate the desired magnetic field for B0 shimming. Proof-of-concept phantom experiments with an iPRES(2)-A coil and simulations in the human abdomen with an 8-channel iPRES(4)-A body coil array were performed to demonstrate the advantages of this innovative design. RESULTS: The iPRES(2)-A coil showed no loss in signal-to-noise ratio and provided a much more effective correction of highly localized B0 inhomogeneities and geometric distortions than an equivalent iPRES(1) coil (88.2% vs. 32.2% lower B0 root-mean-square error). The iPRES(4)-A coil array showed a comparable shimming performance as that of an equivalent iPRES(4) coil array (52.6% vs. 54.2% lower B0 root-mean-square error), while only requiring 8 instead of 32 power supplies. CONCLUSION: The iPRES(N)-A design retains the ability of the iPRES(N) design to shim highly localized B0 inhomogeneities, while drastically reducing its cost and complexity. Magn Reson Med 80:371-379, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Sistemas Microeletromecânicos/instrumentação , Algoritmos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador , Campos Magnéticos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Razão Sinal-Ruído
18.
Magn Reson Med ; 77(5): 2048-2056, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27174499

RESUMO

PURPOSE: MRI is increasingly used to scan pregnant patients. We investigated the effect of 3 Tesla (T) two-port radiofrequency (RF) shimming in anatomical pregnant women models. THEORY AND METHODS: RF shimming improves B1+ uniformity, but may at the same time significantly alter the induced current distribution and result in large changes in both the level and location of the absorbed RF energy. In this study, we evaluated the electrothermal exposure of pregnant women in the third, seventh, and ninth month of gestation at various imaging landmarks in RF body coils, including modes with RF shimming. RESULTS: Although RF shimmed configurations may lower the local RF exposure for the mother, they can increase the thermal load on the fetus. In worst-case configurations, whole-body exposure and local peak temperatures-up to 40.8°C-are equal in fetus and mother. CONCLUSIONS: Two-port RF shimming can significantly increase the fetal exposure in pregnant women, requiring further research to derive a very robust safety management. For the time being, restriction to the CP mode, which reduces fetal SAR exposure compared with linear-horizontal polarization modes, may be advisable. Results from this study do not support scanning pregnant patients above the normal operating mode. Magn Reson Med 77:2048-2056, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Complicações na Gravidez/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Ondas de Rádio , Algoritmos , Simulação por Computador , Feminino , Temperatura Alta , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Recém-Nascido , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Gravidez , Software
19.
Artigo em Inglês | MEDLINE | ID: mdl-31057343

RESUMO

In MRI systems, cable-free receive arrays would simplify setup while reducing the bulk and weight of coil arrays and improve patient comfort and throughput. Since battery power would limit scan time, wireless power transfer (WPT) is a viable option to continuously supply several watts of power to on-coil electronics. To minimize added noise and decouple the wireless power system from MRI coils, restrictions are placed on the coil geometry of the wireless power system, which are shown to limit its efficiency. Continuous power harvesting can also cause a large increase in the background noise of the image due to diode rectifier up-conversion of noise around the frequency of the transmitted power. However, by RF gating the transmitted power off during the MRI receive time while continuing to supply power from a storage capacitor, WPT is demonstrated to have minimal impact on image quality at received power levels up to 11 W. The integration of WPT with a 1.5T scanner is demonstrated.

20.
Magn Reson Med ; 75(2): 859-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26619820

RESUMO

PURPOSE: Develop and test an analytic correction method to correct the signal intensity variation caused by the inhomogeneous reception profile of an eight-channel phased array for hyperpolarized (13) C imaging. THEORY AND METHODS: Fiducial markers visible in anatomical images were attached to the individual coils to provide three dimensional localization of the receive hardware with respect to the image frame of reference. The coil locations and dimensions were used to numerically model the reception profile using the Biot-Savart Law. The accuracy of the coil sensitivity estimation was validated with images derived from a homogenous (13) C phantom. Numerical coil sensitivity estimates were used to perform intensity correction of in vivo hyperpolarized (13) C cardiac images in pigs. RESULTS: In comparison to the conventional sum-of-squares reconstruction, improved signal uniformity was observed in the corrected images. CONCLUSION: The analytical intensity correction scheme was shown to improve the uniformity of multichannel image reconstruction in hyperpolarized [1-(13) C]pyruvate and (13) C-bicarbonate cardiac MRI. The method is independent of the pulse sequence used for (13) C data acquisition, simple to implement and does not require additional scan time, making it an attractive technique for multichannel hyperpolarized (13) C MRI.


Assuntos
Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Isótopos de Carbono , Aumento da Imagem/métodos , Imageamento Tridimensional , Imagens de Fantasmas , Sensibilidade e Especificidade , Suínos