Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Ann Vasc Surg ; 90: 119-127, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36442711

RESUMO

BACKGROUND: Evidence suggests thoracic stent grafts increase the aortic stiffness postimplantation. Our objective was to examine the effect of thoracic aortic stenting on heart function, as demonstrated with echocardiography. METHODS: We considered nonrandomized studies examining echocardiographic parameters (left ventricle ejection fraction (LVEF), left ventricle end-diastolic (LVED) and end-systolic diameter (LVESD), posterior wall thickness (LVPWT), interventricular septal thickness (IVST), mass, and mass index) pre and poststent graft implantation in patients with thoracic aortic diseases (aneurysm, dissection, and blunt injury). MEDLINE and CENTRAL were searched (up to March 2021) for eligible studies. The National Institutes of Health Quality Assessment Tool was used for risk of bias assessment. Echocardiographic data pre and postimplantation were compared using the pooled standardized mean difference (SMD) and 95% confidence interval (CI). RESULTS: Four studies were included in the meta-analysis. Three of the studies were judged to be "good" quality and one "fair". Nonsignificant differences pre and postimplantation were found for ejection fraction (SMD = -0.53, 95% CI = -1.8 to 0.728, P = 0.406), IVST (SMD = -0.79, 95%, CI = -3.25 to 1.66, P = 0.52), EDD (SMD = -0.10, 95% CI = -0.48 to 0.28, P = 0.60), ESD (SMD = -0.66, 95% CI = -2.35 to 1.02, P = 0.44), and PWT (SMD = -2.20, 95% CI = -5.89 to 1.47, P = 0.24). A trend toward an increase in mass postimplantation was found (SMD = 0.28, 95%, CI = -0.03 to 0.60, P = 0.08), but there was no significant difference in mass index (SMD = 0, 95%, CI = -0.195 to 0.195, P = 1). CONCLUSIONS: Thoracic aortic stenting does not appear to significantly impact cardiac physiology as indicated by echocardiographic parameters.


Assuntos
Ecocardiografia , Correção Endovascular de Aneurisma , Humanos , Resultado do Tratamento , Aorta Torácica/cirurgia , Aorta
2.
J Card Surg ; 37(10): 3322-3324, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35801496

RESUMO

Surgical restoration of the left ventricular outflow tract (LVOT) is necessary for patients suffering from hypertrophic obstructive cardiomyopathy (HOCM), when symptoms are present despite the administration of medical treatment. One point of great significance during the procedure is the evaluation of the LVOT gradient after completion of septal myectomy. Most physicians choose to measure this value by transesophageal echocardiography (TEE) in combination with the direct measurement with the use of needles inserted into the aorta and left ventricle. In this article, we present the implementation of a new technique to estimate the peak-to-peak pressure gradient between the left ventricle and the aorta intraoperatively using a single double lumen central venous catheter inserted through the antegrade cardioplegia cannulation site across the aortic valve into the left ventricle.


Assuntos
Cardiomiopatia Hipertrófica , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Ponte de Artéria Coronária , Ecocardiografia Transesofagiana , Ventrículos do Coração , Humanos , Resultado do Tratamento
3.
J Vasc Surg ; 69(4): 996-1002.e3, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30528410

RESUMO

OBJECTIVE: The aim of the study was to present the results for patients with atherosclerotic aneurysm of the descending thoracic aorta (DTA) treated with a novel thoracic stent graft. METHODS: A single-center retrospective review of prospectively collected data was performed. We extracted demographic variables as well as atherosclerotic comorbidities and operation-related and imaging-related data from patients' medical records. We estimated technical success rate, in-hospital and 30-day mortality, and mortality at the end of follow-up as well as complication and reintervention rate in our study cohort. Follow-up computed tomography angiography was performed after 1 month and 6 months and yearly thereafter. RESULTS: A total of 30 patients (80% male; mean age, 73.7 ± 6.33 years) were treated with Ankura Thoracic Stent Graft (Lifetech, Shenzhen, China) for DTA aneurysm from February 2014 until June 2017. Technical success of the thoracic endovascular aortic repair (TEVAR) was 97% (29/30 patients). A surgical conduit was required in one patient; in three patients, we intentionally covered the left subclavian artery because of insufficient proximal landing zone. No aorta-related deaths were recorded during follow-up. During the early postoperative period, two patients (7%) with long DTA coverage developed paralysis or paraparesis, which immediately resolved after lumbar drainage. No renal complications requiring dialysis were observed. One patient (3%) developed postoperative pulmonary infection, whereas access site complications were 7%. Two symptomatic patients treated outside instructions for use (7%) developed early type IA endoleak and one patient (3%) developed type IB endoleak; type II endoleak was recorded in 3% of the study cohort. During the 30-day postoperative period, two patients died of non-TEVAR-related causes, one of gastrointestinal bleeding and the other of pulmonary infection. During a median follow-up of 31.7 (range, 38.4) months, two more patients also died of non-TEVAR-related causes, one of stroke from carotid artery disease and the other of motor vehicle trauma. In the rest of the cohort, no other adverse events were noted. CONCLUSIONS: This novel endograft showed early evidence of a safe, effective, and durable endoprosthesis for the treatment of DTA aneurysms.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Clin Cardiol ; 47(7): e24307, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38953367

RESUMO

BACKGROUND: We aim to provide a comprehensive review of the current state of knowledge of myocardial viability assessment in patients undergoing coronary artery bypass grafting (CABG), with a focus on the clinical markers of viability for each imaging modality. We also compare mortality between patients with viable myocardium and those without viability who undergo CABG. METHODS: A systematic database search with meta-analysis was conducted of comparative original articles (both observations and randomized controlled studies) of patients undergoing CABG with either viable or nonviable myocardium, in EMBASE, MEDLINE, Cochrane database, and Google Scholar, from inception to 2022. Imaging modalities included were dobutamine stress echocardiography (DSE), cardiac magnetic resonance (CMR), single-photon emission computed tomography (SPECT), and positron emission tomography (PET). RESULTS: A total of 17 studies incorporating a total of 2317 patients were included. Across all imaging modalities, the relative risk of death post-CABG was reduced in patients with versus without viability (random-effects model: odds ratio: 0.42; 95% confidence interval: 0.29-0.61; p < 0.001). Imaging for myocardial viability has significant clinical implications as it can affect the accuracy of the diagnosis, guide treatment decisions, and predict patient outcomes. Generally, based on local availability and expertise, either SPECT or DSE should be considered as the first step in evaluating viability, while PET or CMR would provide further evaluation of transmurality, perfusion metabolism, and extent of scar tissue. CONCLUSION: The assessment of myocardial viability is an essential component of preoperative evaluation in patients with ischemic heart disease undergoing surgical revascularization. Careful patient selection and individualized assessment of viability remain paramount.


Assuntos
Ponte de Artéria Coronária , Isquemia Miocárdica , Função Ventricular Esquerda , Humanos , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Cardiomiopatias/diagnóstico , Cardiomiopatias/etiologia , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/complicações , Ecocardiografia sob Estresse/métodos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/complicações , Miocárdio/patologia , Sobrevivência de Tecidos , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda/fisiologia
6.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
7.
Antibiotics (Basel) ; 12(7)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37508278

RESUMO

In our hospital, adherence to the guidelines for peri-operative antimicrobial prophylaxis (PAP) is suboptimal, with overly long courses being common. This practice does not offer any incremental benefit, and it only adds to the burden of antimicrobial consumption, promotes the emergence of antimicrobial resistance, and it is associated with adverse events. Our objective was to study the effect of an electronic reminder on the adherence to each element of PAP after cardiac surgery. We conducted a single center, before and after intervention, prospective cohort study from 1 June 2014 to 30 September 2017. The intervention consisted of a reminder of the hospital guidelines when ordering PAP through the hospital information system. The primary outcome was adherence to the suggested duration of PAP, while secondary outcomes included adherence to the other elements of PAP and incidence of surgical site infections (SSI). We have studied 1080 operations (400 pre-intervention and 680 post-intervention). Adherence to the appropriate duration of PAP increased significantly after the intervention [PRE 4.0% (16/399) vs. POST 15.4% (105/680), chi-square p < 0.001]; however, it remained inappropriately low. Factors associated with inappropriate duration of PAP were pre-operative hospitalization for <3 days, and duration of operation >4 h, while there were significant differences between the chief surgeons. Unexpectedly, the rate of SSIs increased significantly during the study (PRE 2.8% (11/400) vs. POST 5.9% (40/680), chi-square p < 0.019). The implemented intervention achieved a relative increase in adherence to the guideline-recommended PAP duration; however, adherence was still unacceptably low and further efforts to improve adherence are needed.

8.
Semin Thorac Cardiovasc Surg ; 34(1): 123-132, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33460764

RESUMO

The impairment of intracellular calcium homeostasis plays an essential role during ischemia-reperfusion injury. Calcium release from sarcoplasmic reticulum which is triggered by myocardial ischemia is mainly mediated by ryanodine receptors. Dantrolene sodium is a ryanodine receptor antagonist. The objective of the present study was to evaluate the in-vivo impact of dantrolene sodium on myocardial ischemia-reperfusion injury in swine models. An in vivo, experimental trial comparing 10 experimental animals which received dantrolene sodium with 9 control swine models was conducted. Their left anterior descending coronary artery was temporarily occluded for 75 minutes via a vessel tourniquet, which was then released. Myocardial reperfusion was allowed for 24 hours. Dantrolene was administered at the onset of the reperfusion period and levels of troponin, creatine phosphokinase and creatine kinase myocardial band between the two groups were compared. Additionally, various other hemodynamic parameters and left ventricular morphology and function were examined. There were significantly lower values of troponin, creatine phosphokinase and creatine kinase myocardial band in the dantrolene group indicating less ischemia-reperfusion injury. Moreover, the postischemic cardiac index was also greater in the dantrolene group, whereas viable myocardium was also better preserved. In conclusion, the in vivo cardioprotective role of dantrolene sodium against ischemia-reperfusion injury in swine models was indicated in this study. Therefore, dantrolene sodium administration could be a promising treatment against ischemia-reperfusion injury in humans. However, large randomized clinical studies should be firstly carried out to prove this hypothesis.


Assuntos
Isquemia Miocárdica , Traumatismo por Reperfusão Miocárdica , Animais , Cálcio/metabolismo , Creatina Quinase/metabolismo , Dantroleno/farmacologia , Dantroleno/uso terapêutico , Homeostase , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/metabolismo , Rianodina , Canal de Liberação de Cálcio do Receptor de Rianodina , Suínos , Resultado do Tratamento , Troponina
9.
J Tehran Heart Cent ; 17(1): 26-28, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36304763

RESUMO

Ligation of the left innominate vein (LIV) expands the surgeon's surgical field for ascending aorta and aortic arch procedures. Although it is considered a safe technique by most surgeons in that it is associated with only minor drawbacks, conflicting views exist regarding this method. We herein describe a 70-year-old woman who underwent ascending aorta replacement due to an aneurysm with subsequent cerebral dysfunction caused by extended brain edema, possibly related to LIV ligation, leading to her death.

10.
Ann Card Anaesth ; 24(2): 247-249, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33884987

RESUMO

Coronary artery bypass grafting is the mainstay of revascularization worldwide. However, the most widely used saphenous vein grafts are related to a number of late sequelae. Aortocoronary saphenous vein graft aneurysms mainly diagnosed incidentally are one of these complications. Although rare, given the fatal risk of rupture if left untreated, management either with percutaneous intervention or open redo surgery should be considered. However, no guidelines are established in current scarce literature. Hereby, we present the successful percutaneous management of a huge saphenous vein graft aneurysm via coiling, avoiding the risks of repeat sternotomy.


Assuntos
Aneurisma Aórtico , Veia Safena , Aorta Torácica , Ponte de Artéria Coronária , Erros de Diagnóstico , Humanos , Veia Safena/diagnóstico por imagem
11.
Indian J Thorac Cardiovasc Surg ; 37(5): 584-587, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34511770

RESUMO

Hybrid arch replacement is a well-accepted method for the treatment of lesions involving the aortic arch, though its benefits compared to classic surgical techniques remain controversial. Multiple surgical approaches have been analyzed in the literature for the treatment of such a challenging pathology. In this case report, we describe the surgical management of a 72-year-old man presenting with a complicated aortic arch rupture. The patient was treated urgently with a type I hybrid arch replacement in two stages, with total preservation of cerebral and systemic perfusion. Our case shows that hybrid arch methods are applicable even in emergency cases.

12.
Am J Case Rep ; 21: e925931, 2020 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-32980852

RESUMO

BACKGROUND The worldwide spread of the severe acute respiratory syndrome-coronavirus-2 (SARS-COV-2) has created unprecedented situations for healthcare professionals and healthcare systems. Although infection with this virus is considered the main health problem currently, other diseases are still prevalent. CASE REPORT This report describes a 59-year-old man who presented with symptoms of dyspnea and fever that were attributed to Covid-19 infection. His clinical condition deteriorated and further examinations revealed a subjacent severe aortic regurgitation due to acute infective endocarditis. Surgical treatment was successful. CONCLUSIONS The results of diagnostic tests for Covid-19 should be re-evaluated whenever there are clinical mismatches or doubts, as false-positive Covid-19 test results can occur. Clinical interpretation should not be determined exclusively by the Covid-19 pandemic. This case report highlights the importance of using validated and approved serological and molecular testing to detect infection with SARS-CoV-2, and to repeat tests when there is doubt about presenting symptoms.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Diagnóstico Tardio , Endocardite/complicações , Endocardite/diagnóstico , Pneumonia Viral/diagnóstico , Anticorpos Antivirais/análise , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , COVID-19 , Teste para COVID-19 , Procedimentos Cirúrgicos Cardíacos/métodos , Infecções por Coronavirus/complicações , Estado Terminal , Progressão da Doença , Dispneia/diagnóstico , Dispneia/etiologia , Endocardite/virologia , Reações Falso-Positivas , Febre/diagnóstico , Febre/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Prognóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Medição de Risco , Resultado do Tratamento
13.
Ann Card Anaesth ; 23(2): 235-236, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32275046

RESUMO

Long-term survival of patients submitted to a Fontan procedure is reduced because of arrhythmias. Late post-Fontan ventricular tachycardia is extremely rare, but it can be fatal. Consequently, the implantation of an implantable cardioverter defibrillator may be required. The implantation of such a device after a Fontan operation can be rather difficult due to anatomic reasons that exclude transvenous approach. Epicardial ICD implantation is a treatment option for these patients. Transatrial approach, shock ICD coils placement in azygos vein or directly in the pericardium are possible alternatives. We hereby present a successful epicardial implantable cardioverter defibrillator implantation in a post-Fontan 39-year-old man suffering from ventricular tachycardia.


Assuntos
Desfibriladores Implantáveis , Técnica de Fontan/efeitos adversos , Complicações Pós-Operatórias/terapia , Taquicardia Ventricular/terapia , Adulto , Humanos , Masculino
14.
Ann Card Anaesth ; 22(2): 225-228, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30971610

RESUMO

We present a case with aortic rupture during an operation of thoracic endovascular aortic repair of an anastomotic pseudoaneurysm. This happened after the use of a low-pressure remodeling balloon inside the covered part of the deployed endografts. It was successfully treated with a second more centrally in the aortic arch-implanted endograft with full coverage of the left subclavian artery orifice. This patient had a history of surgically operated aortic coarctation.


Assuntos
Falso Aneurisma/cirurgia , Coartação Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Tratamento de Emergência/métodos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/cirurgia , Stents , Falso Aneurisma/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Interact Cardiovasc Thorac Surg ; 28(1): 9-16, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29945176

RESUMO

There are few cases in the literature reporting dysphagia caused by oesophageal compression by the aorta due to acute or chronic aortic pathology. This type of dysphagia is called dysphagia aortica. Thoracic endovascular aortic repair is nowadays the treatment of choice for anatomically suitable patients experiencing complicated Type B aortic dissection. Oesophageal necrosis is a rare but fatal complication following thoracic endovascular aortic repair. Extrinsic oesophageal compression by the thrombosed aneurysmal sac, a mediastinal haematoma or extensive thrombosis in the false lumen of a dissected aorta and acute vascular occlusion of the oesophageal supply are possible mechanisms. When oesophageal necrosis is suspected, endoscopic examination and computed tomography imaging should be performed repeatedly. Oesophagoscopy will confirm the diagnosis revealing a black, diffusely necrotic and ulcerated oesophageal mucosa. It is critical to intervene before full-thickness oesophageal wall necrosis and mediastinitis occur. Guidelines are absent because of the rarity of this complication. Moreover, lack of a large series does not permit the establishment of guidelines either. However, oesophagectomy of the impaired oesophagus is the only chance for survival. Unfortunately, survival rates are disappointing. Prevention and awareness is the cornerstone of success. Early endoscopic examination when oesophageal necrosis is suspected due to even minimal symptoms will detect this fatal menace on time.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Transtornos de Deglutição/etiologia , Procedimentos Endovasculares/efeitos adversos , Esôfago/patologia , Complicações Pós-Operatórias , Trombose/etiologia , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/cirurgia , Humanos , Necrose/diagnóstico , Necrose/etiologia , Trombose/diagnóstico , Tomografia Computadorizada por Raios X
16.
Cardiovasc J Afr ; 29(1): e6-e8, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29582882

RESUMO

Adult cardiac surgery is associated with significant perioperative morbidity and mortality rates, mainly in elderly patients with co-morbidities. A series of postoperative complications may arise and delay the recovery of patients undergoing cardiac surgery. Such complications also increase the burden of resource use and may affect late survival rates. Neurological complications appear mainly as stroke of varying degrees, with impairment of mobility and ability of the patient. We describe a rare case of progressive paraparesis after on-pump coronary artery bypass grafting, and review its aetiology, diagnosis and management.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Síndrome de Guillain-Barré/etiologia , Paraparesia/etiologia , Compressão da Medula Espinal/etiologia , Isquemia do Cordão Espinal/etiologia , Idoso , Edema Encefálico/etiologia , Ponte Cardiopulmonar/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Evolução Fatal , Síndrome de Guillain-Barré/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Paraparesia/diagnóstico por imagem , Posicionamento do Paciente/efeitos adversos , Choque Séptico/etiologia , Compressão da Medula Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiothorac Surg ; 13(1): 75, 2018 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-29929527

RESUMO

BACKGROUND: A 44 year old man who presented with a history of chest pain and dyspnoea was found to have an aneurysm of the aortic root, aortic valve insufficiency, and coarctation of the aorta. CASE PRESENTATION: The patient underwent a single stage procedure to treat the aortic root, valve and coarctation with a composite valved conduit and extra-anatomic bypass of the coarctation. The modified Cabrol technique was necessary to attach the coronary buttons due to grossly abnormal anatomy. The patient made a remarkable recovery and was discharged on the 8th post-operative day. CONCLUSION: This case report highlights the feasibility and efficacy of performing a single stage procedure on complex coarctation with associated cardiac defects. To the best of our knowledge, this is the first report of the modified Cabrol technique being used in this particular setting.


Assuntos
Aneurisma Aórtico/cirurgia , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Adulto , Hemodinâmica , Humanos , Imageamento Tridimensional , Masculino , Revascularização Miocárdica , Pericárdio/cirurgia , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Vasculares
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa