Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Eur Radiol ; 32(11): 7409-7419, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35482122

RESUMO

OBJECTIVES: Abbreviated breast MRI (AB-MRI) was introduced to reduce both examination and image reading times and to improve cost-effectiveness of breast cancer screening. The aim of this model-based economic study was to analyze the cost-effectiveness of full protocol breast MRI (FB-MRI) vs. AB-MRI in screening women with dense breast tissue for breast cancer. METHODS: Decision analysis and a Markov model were designed to model the cumulative costs and effects of biennial screening in terms of quality-adjusted life years (QALYs) from a US healthcare system perspective. Model input parameters for a cohort of women with dense breast tissue were adopted from recent literature. The impact of varying AB-MRI costs per examination as well as specificity on the resulting cost-effectiveness was modeled within deterministic sensitivity analyses. RESULTS: At an assumed cost per examination of $ 263 for AB-MRI (84% of the cost of a FB-MRI examination), the discounted cumulative costs of both MR-based strategies accounted comparably. Reducing the costs of AB-MRI below $ 259 (82% of the cost of a FB-MRI examination, respectively), the incremental cost-effectiveness ratio of FB-MRI exceeded the willingness to pay threshold and the AB-MRI-strategy should be considered preferable in terms of cost-effectiveness. CONCLUSIONS: Our preliminary findings indicate that AB-MRI may be considered cost-effective compared to FB-MRI for screening women with dense breast tissue for breast cancer, as long as the costs per examination do not exceed 82% of the cost of a FB-MRI examination. KEY POINTS: • Cost-effectiveness of abbreviated breast MRI is affected by reductions in specificity and resulting false positive findings and increased recall rates. • Abbreviated breast MRI may be cost-effective up to a cost per examination of 82% of the cost of a full protocol examination. • Abbreviated breast MRI could be an economically preferable alternative to full protocol breast MRI in screening women with dense breast tissue.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico , Mamografia/métodos , Densidade da Mama , Detecção Precoce de Câncer/métodos , Programas de Rastreamento , Imageamento por Ressonância Magnética/métodos , Análise Custo-Benefício , Anos de Vida Ajustados por Qualidade de Vida
2.
BMC Med Imaging ; 22(1): 214, 2022 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-36471287

RESUMO

BACKGROUND: Uterine fibroid embolisation (UFE) is an established treatment method for symptomatic uterine myomas. This study evaluates the efficacy of UFE using objective magnetic resonance imaging (MRI) data for size and perfusion analysis as well as patient questionnaires assessing fibroid-related symptoms. METHOD: Patients underwent MR-Angiography before UFE and 4 days, 6 and 12 months after the procedure. The images were evaluated using dedicated software. Patient questionnaires were completed before UFE and at 12 months follow-up, focussing on the embolization procedure and symptoms associated with uterine fibroids. Statistical analysis of the questionnaires was performed using paired sample t-test and Wilcoxon signed rank test, while Kruskal-Wallis test and Friedman test were applied for MRI-analysis. RESULTS: Eleven women were included. There was a significant reduction in fibroid-related symptoms. The volume reduction after 12 months was significant in both, uterus and myomas, after an initial increase in uterine volume at the first post-interventional MRI. The perfusion analysis showed that blood flow to the fibroids could be significantly reduced up to 12 months after UFE while uterine tissue was not affected. CONCLUSION: This study shows that uterine fibroid embolisation induces a significant long-term decrease in myoma size and perfusion while healthy uterine tissue remains unaffected. Fibroid-related symptoms are reduced for the sake of improved quality of life.


Assuntos
Leiomioma , Mioma , Neoplasias Uterinas , Humanos , Feminino , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Qualidade de Vida , Resultado do Tratamento , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Inquéritos e Questionários , Imageamento por Ressonância Magnética/métodos , Perfusão
3.
ORL J Otorhinolaryngol Relat Spec ; 83(6): 439-448, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33784686

RESUMO

INTRODUCTION: Augmented reality can improve planning and execution of surgical procedures. Head-mounted devices such as the HoloLens® (Microsoft, Redmond, WA, USA) are particularly suitable to achieve these aims because they are controlled by hand gestures and enable contactless handling in a sterile environment. OBJECTIVES: So far, these systems have not yet found their way into the operating room for surgery of the parotid gland. This study explored the feasibility and accuracy of augmented reality-assisted parotid surgery. METHODS: 2D MRI holographic images were created, and 3D holograms were reconstructed from MRI DICOM files and made visible via the HoloLens. 2D MRI slices were scrolled through, 3D images were rotated, and 3D structures were shown and hidden only using hand gestures. The 3D model and the patient were aligned manually. RESULTS: The use of augmented reality with the HoloLens in parotic surgery was feasible. Gestures were recognized correctly. Mean accuracy of superimposition of the holographic model and patient's anatomy was 1.3 cm. Highly significant differences were seen in position error of registration between central and peripheral structures (p = 0.0059), with a least deviation of 10.9 mm (centrally) and highest deviation for the peripheral parts (19.6-mm deviation). CONCLUSION: This pilot study offers a first proof of concept of the clinical feasibility of the HoloLens for parotid tumor surgery. Workflow is not affected, but additional information is provided. The surgical performance could become safer through the navigation-like application of reality-fused 3D holograms, and it improves ergonomics without compromising sterility. Superimposition of the 3D holograms with the surgical field was possible, but further invention is necessary to improve the accuracy.


Assuntos
Realidade Aumentada , Neoplasias Parotídeas , Cirurgia Assistida por Computador , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/cirurgia , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Parotídeas/cirurgia , Projetos Piloto , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos
4.
Radiologe ; 61(Suppl 1): 49-53, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34013397

RESUMO

BACKGROUND: The fascia thoracolumbalis (FTL) is an important component for stabilization and motion control of the lumbar spine. It coordinates the traction forces of the autochthonous muscles of the back (AM) and connects them to the muscles of the abdominal wall, shoulder, and buttocks. OBJECTIVES: The aim of our study was to describe the assessment of the normal FTL and epimysium of the AM in MRI and to identify patterns associated with pathological changes in the lumbar spine. MATERIAL AND METHODS: A total of 33 patients were retrospectively evaluated: 15 patients had no pathology at the lumbar spine; six patients had previous hemilaminectomy, three had spondylodesis, two had ventrolisthesis, and seven had scoliosis. The thickness of the FTL and EM was measured, and the adhesion of both structures was assessed. RESULTS: The fascial thickness at the levels of the lumbar vertebral bodies LVB 3 was 1.8, of LVB 4 it was 2.0, of LVB 5 it was 2.1, and at the sacral vertebra SVB 1 it was 1.8 mm. Fascial adhesions together with thickening of the EM occurred at the level of LVB 4 in 36% of the cases independently of the underlying disorder. Only thickening of the EM was seen in 48% of cases at the level of SVB 1. By contrast, adhesion of the FTL without epimysial changes occurred in 36% of cases at the level of LVB 3. CONCLUSION: Thickening and adhesions at the EM and FTL occurred both postoperatively and in the case of scoliosis. Furthermore, lipomatous and muscular herniation could be detected in the FTL postoperatively. Epimysial and fascial alterations may be imaging manifestations of chronic myofascial back pain and should be included in radiological assessments.


Assuntos
Fáscia , Vértebras Lombares , Fáscia/diagnóstico por imagem , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Músculo Esquelético , Estudos Retrospectivos
5.
Vasa ; 50(6): 468-474, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34269078

RESUMO

Background: In peripheral arterial disease (PAD) the femoropopliteal (FP) artery is the most frequently recanalized lower limb artery. Stent-based interventions change the biomechanical properties of FP arteries. However, no clinical tool for functional imaging is established for quantitative measurements in vivo. Four-dimensional-flow magnetic resonance imaging enables a detailed evaluation of the hemodynamics of the central and - more challenging - the peripheral arteries. The present study aimed to determine the feasibility of assessing pulse wave velocities (PWV) as a marker of vessel stiffness in PAD patients with multiple spot stents and to compare the values with age-matched subjects and young-adult healthy subjects. Patients and methods: Contrast-free 4D-flow MRI was performed in seven PAD patients with focally stented FP arteries, five age-matched subjects after exclusion of PAD, and five young, healthy adults. PWV values were calculated from flow curves by using the foot-to-foot method. Results: Four-D-flow MRI sequences offering high spatial and temporal resolution enables quantification of flow velocity measurements and estimation of PWVs. Assessment of segmental PWV as a surrogate of vascular stiffness in focally stented femoral arteries is feasible. PWV values across all groups were 15.6±5.2 m/s, 13.3±4.1 m/s, and 9.9±2.2 m/s in PAD patients, senior-aged volunteers, and young-adult volunteers respectively. PWV values in PAD patients were similar with those in the senior-aged volunteers group (15.6±5.2 vs. 13.3 ±4.1 years, p=0.43). However, when compared to the young-adult volunteers, PAD patients had a statistically significantly higher mean local PWV (15.6±5.2 m/s vs. 9.9±2.2 m/s, p<0.05). Conclusions: Calculating segmental PWV in the femoral arteries is feasible in PAD patients with focally stented FP arteries. PWV values in PAD patients were similar to those in senior-aged volunteers, both of which were higher than in young-adult volunteers.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Artéria Femoral/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Stents
6.
Eur Radiol ; 29(5): 2378-2387, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30523456

RESUMO

OBJECTIVES: We sought to investigate the diagnostic performance of coronary CT angiography (cCTA)-derived plaque markers combined with deep machine learning-based fractional flow reserve (CT-FFR) to identify lesion-specific ischemia using invasive FFR as the reference standard. METHODS: Eighty-four patients (61 ± 10 years, 65% male) who had undergone cCTA followed by invasive FFR were included in this single-center retrospective, IRB-approved, HIPAA-compliant study. Various plaque markers were derived from cCTA using a semi-automatic software prototype and deep machine learning-based CT-FFR. The discriminatory value of plaque markers and CT-FFR to identify lesion-specific ischemia on a per-vessel basis was evaluated using invasive FFR as the reference standard. RESULTS: One hundred three lesion-containing vessels were investigated. 32/103 lesions were hemodynamically significant by invasive FFR. In a multivariate analysis (adjusted for Framingham risk score), the following markers showed predictive value for lesion-specific ischemia (odds ratio [OR]): lesion length (OR 1.15, p = 0.037), non-calcified plaque volume (OR 1.02, p = 0.007), napkin-ring sign (OR 5.97, p = 0.014), and CT-FFR (OR 0.81, p < 0.0001). A receiver operating characteristics analysis showed the benefit of identifying plaque markers over cCTA stenosis grading alone, with AUCs increasing from 0.61 with ≥ 50% stenosis to 0.83 with addition of plaque markers to detect lesion-specific ischemia. Further incremental benefit was realized with the addition of CT-FFR (AUC 0.93). CONCLUSION: Coronary CTA-derived plaque markers portend predictive value to identify lesion-specific ischemia when compared to cCTA stenosis grading alone. The addition of CT-FFR to plaque markers shows incremental discriminatory power. KEY POINTS: • Coronary CT angiography (cCTA)-derived quantitative plaque markers of atherosclerosis portend high discriminatory power to identify lesion-specific ischemia. • Coronary CT angiography-derived fractional flow reserve (CT-FFR) shows superior diagnostic performance over cCTA alone in detecting lesion-specific ischemia. • A combination of plaque markers with CT-FFR provides incremental discriminatory value for detecting flow-limiting stenosis.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Diagnóstico por Computador/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Aprendizado de Máquina , Placa Aterosclerótica/diagnóstico , Estenose Coronária/etiologia , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/fisiopatologia , Curva ROC , Estudos Retrospectivos
8.
Eur Heart J ; 34(10): 775-81, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22390914

RESUMO

AIMS: Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. METHODS AND RESULTS: In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. CONCLUSION: In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Angiografia por Ressonância Magnética/efeitos adversos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
9.
Rofo ; 2024 Jul 29.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-39074798

RESUMO

The decision as to whether to perform a computed tomography (CT) examination in severe pediatric trauma poses a challenge. The therapeutic benefit of computed tomography in injured children is lower compared to adults, while the potential negative effects of ionizing radiation may be higher. Thus, the threshold for CT should be higher. Centers that less frequently treat pediatric cases tend to conduct more whole-body CT examinations than dedicated pediatric trauma centers, indicating a clinical overestimation of injury severity with subsequently unnecessary imaging due to inexperience. On the other hand, a CT scan that is not performed but is actually necessary can also have negative consequences if an injury is detected with a delay. An injured child presents a challenging situation for all involved healthcare providers, and thus requires a structured approach to decision-making.Selective literature review of the benefits and risks of CT in injured children, as well as indications for whole-body and region-specific CT imaging.This article provides an overview of current guidelines, recent insight into radiation protection and the benefits of CT in injured children, and evidence-based decision criteria for choosing the appropriate modality based on the mechanism of injury and the affected body region. · Whole-body CT has less of an influence on treatment decisions and mortality in severely injured children than in adults.. · For radiation protection reasons, the indication should be determined more conservatively in children than in adult trauma patients.. · The indication for CT should ideally be determined separately for each region of the body.. · Ultrasound and MRI are a good alternative for the primary diagnostic workup in many situations.. · Appelhaus S, Schönberg SO, Weis M. CT in pediatric trauma patients. Fortschr Röntgenstr 2024; DOI 10.1055/a-2341-7559.

10.
Rofo ; 196(2): 186-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37922942

RESUMO

PURPOSE: Analysis of clinical and diagnostic findings in rare urogenital and perineal vascular malformations only occurring in 2-3 % of vascular anomalies with regard to clinical symptoms and treatment decisions. MATERIALS AND METHODS: All 25 out of 537 patients presenting with congenital urogenital and perineal vascular malformations at our institution from 2014 to 2021 were included. Vascular anomaly classification, anatomical location, clinical symptoms at presentation, diagnostic imaging, and pain intensity were retrospectively assessed from the patient record and therapy management was evaluated. RESULTS: In total, 25 patients (10 females (40 %), 15 males (60 %)), aged 6 to 77 years were included. Diagnoses were: 10 (40 %) venous malformations (VMs), 5 (20 %) lymphatic malformations (LMs) and 10 (40 %) arteriovenous malformations (AVMs). Malformation manifestations were: 12 (32 %) lesser pelvis, 12 (32 %) external genitalia, and 13 (34 %) perineal/gluteal region. One AVM was located in the kidney. The leading clinical symptom was pain. The mean intensity was 6.0/10 for LM, 5.7/10 for VM, and 4.5/10 for AVM. Further major symptoms included physical impairment, local swelling, and skin discoloration. Bleeding complications or sexual dysfunction were rare findings. Patients with VM reported significantly more symptoms than patients with AVM (p = 0.0129). In 13 patients (52 %) minimally invasive therapy was indicated: 10 (77 %) sclerotherapies and 3 (23 %) transcatheter embolization procedures. Complete symptomatic remission was achieved in 9 (69 %) patients, partial response in 3 (23 %) patients, and 1 patient showed no clinical response to therapy. Follow-up appointments without the need for immediate minimally invasive therapy were significantly more common in patients with AVMs than in patients with VMs (p = 0.0198). CONCLUSION: To create a higher awareness of congenital urogenital and perineal vascular malformations. Awareness of this rare condition avoids misdiagnosis. Therapy decisions should be symptom-oriented. Emergency intervention is rarely required, even in fast-flow vascular malformations. KEY POINTS: · Venous malformations cause more symptoms with higher pain intensity than arteriovenous malformations.. · Diagnosis and adequate treatment can be hampered by a lack of awareness of the clinical presentation.. · Bleeding complications are rare, even in high-flow vascular malformations.. · Pain and physical impairment are the most commonly observed symptoms in these patients..


Assuntos
Malformações Arteriovenosas , Malformações Vasculares , Masculino , Feminino , Humanos , Estudos Retrospectivos , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/terapia , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Diagnóstico por Imagem , Dor , Resultado do Tratamento
11.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535047

RESUMO

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.

12.
Rofo ; 196(3): 262-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37944935

RESUMO

With personalized tumor therapy, understanding and addressing the heterogeneity of malignant tumors is becoming increasingly important. Heterogeneity can be found within one lesion (intralesional) and between several tumor lesions emerging from one primary tumor (interlesional). The heterogeneous tumor cells may show a different response to treatment due to their biology, which in turn influences the outcome of the affected patients and the choice of therapeutic agents. Therefore, both intra- and interlesional heterogeneity should be addressed at the diagnostic stage. While genetic and biological heterogeneity are important parameters in molecular tumor characterization and in histopathology, they are not yet addressed routinely in medical imaging. This article summarizes the recently established markers for tumor heterogeneity in imaging as well as heterogeneous/mixed response to therapy. Furthermore, a look at emerging markers is given. The ultimate goal of this overview is to provide comprehensive understanding of tumor heterogeneity and its implications for radiology and for communication with interdisciplinary teams in oncology. KEY POINTS:: · Tumor heterogeneity can be described within one lesion (intralesional) or between several lesions (interlesional).. · The heterogeneous biology of tumor cells can lead to a mixed therapeutic response and should be addressed in diagnostics and the therapeutic regime.. · Quantitative image diagnostics can be enhanced using AI, improved histopathological methods, and liquid profiling in the future..


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/genética , Neoplasias/terapia , Diagnóstico por Imagem , Oncologia , Radiografia
13.
J Clin Med ; 13(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38202274

RESUMO

OBJECTIVE: Fetal magnetic resonance imaging (MRI) is broadly used as a method for assessing prognosis in congenital diaphragmatic hernia (CDH). In addition to the extent of lung hypoplasia, determined by measuring the lung volume, cardiac impairment due to pulmonary hypertension and left cardiac hypoplasia is decisive for the prognosis. The percentage area of left ventricle (pALV) describes the percentage of the inner area of the left ventricle in relation to the total area, whereas the mediastinal shift angle (MSA) quantifies the extent of cardiac displacement. The prognostic value of pALV and MSA should be evaluated in terms of survival, the need for extracorporeal membrane oxygenation (ECMO) therapy, and the development of chronic lung disease (CLD). METHODS: In a total of 122 fetal MRIs, the MSA and pALV were measured retrospectively and complete outcome parameters were determined regarding survival for all 122 subjects, regarding ECMO therapy in 109 cases and about the development of CLD in 78 cases. The prognostic value regarding the endpoints was evaluated using logistic regression and ROC analysis. RESULTS: The MSA was significantly higher in children who received ECMO therapy (p = 0.0054), as well as in children who developed CLD (p = 0.0018). ROC analysis showed an AUC of 0.68 for ECMO requirement and 0.77 with respect to CLD development. The pALV showed a tendency towards higher levels in children who received ECMO therapy (p = 0.0824). The MSA and the pALV had no significant effect on survival (MSA: p = 0.4293, AUC = 0.56; pALV: p = 0.1134, AUC = 0.57). CONCLUSIONS: The MSA determined in fetal MRI is a suitable prognostic parameter for ECMO requirement and CLD development in CDH patients and can possibly be used as a supplement to the established parameters.

14.
J Dent ; 142: 104859, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38272436

RESUMO

OBJECTIVE: To investigate the image quality of a low-dose dental imaging protocol in the first clinical photon-counting computed tomography (PCCT) system in comparison to a normal-dose acquisition in a digital volume tomography (DVT) system. MATERIALS AND METHODS: Clinical PCCT systems offer an increased spatial resolution compared to previous generations of clinical systems. Their spatial resolution is in the order of dental DVT systems. Resolution-matched acquisitions of ten porcine jaws were performed in a PCCT (Naeotom Alpha, Siemens Healthineers) and in a DVT (Orthophos XL, Dentsply Sirona). PCCT images were acquired with 90 kV at a dose of 1 mGy CTDI16 cm. DVT used 85 kV at 4 mGy. Image reconstruction was performed using the standard algorithms of each system to a voxel size of 160 × 160 × 200 µm. The dose-normalized contrast-to-noise ratio (CNRD) was measured between dentine and enamel and dentine and bone. Two readers evaluated overall diagnostic quality of images and quality of relevant structures such as root channels and dentine. RESULTS: CNRD is higher in all PCCT acquisitions. CNRD is 37 % higher for the contrast dentine-enamel and 31 % higher for the dentine-bone contrast (p < 0.05). Overall diagnostic image quality was higher for PCCT over DVT (p < 0.02 and p < 0.04 for readers 1 and 2). Quality scores for anatomical structures were higher in PCCT compared to DVT (all p < 0.05). Inter- and intrareader reproducibility were acceptable (all ICC>0.64). CONCLUSIONS: PCCT provides an increased image quality over DVT even at a lower dose level and might enable complex dental imaging protocols in the future. CLINICAL SIGNIFICANCE: The evolution of photon-counting technology and it's optimization will increasingly move dental imaging towards standardized 3D visualizations providing both minimal radiation exposure and high diagnostic accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Animais , Suínos , Reprodutibilidade dos Testes , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador
15.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535045

RESUMO

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

16.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
17.
Radiology ; 266(3): 887-95, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23238156

RESUMO

PURPOSE: To assess whether chronic lung disease (CLD) in surviving infants with congenital diaphragmatic hernia (CDH) is associated with lung hypoplasia on the basis of the results of antenatal observed-to-expected fetal lung volume (FLV) ratio measurement at magnetic resonance (MR) imaging. MATERIALS AND METHODS: The study received approval from the institutional review board, with waiver of informed consent for this retrospective review from patients who had previously given informed consent for prospective studies. The ratio of observed to expected FLV at MR imaging was calculated in 172 fetuses with CDH. At postpartum day 28, the need for supplemental oxygen implicated the diagnosis of CLD. At day 56, patients with CLD were assigned to one of three groups-those with mild, moderate, or severe CLD-according to their demand for oxygen. Logistic regression analysis was used to assess the prognostic value of the individual observed-to-expected FLV ratio for association with postnatal development of CLD. RESULTS: Children with CLD were found to have significantly smaller observed-to-expected FLV ratios at MR imaging than infants without CLD (P < .001). Grading of CLD revealed significant differences in observed-to-expected FLV ratio between patients with mild CLD and those with moderate (P = .012) or severe (P = .007) CLD. For an observed-to-expected FLV ratio of 5%, 99% of patients with CDH developed CLD, compared with less than 5% of fetuses with an observed-to-expected FLV ratio of 50%. Perinatally, development and grade of CLD were further influenced by the need for extracorporeal membrane oxygenation (ECMO) (P < .001) and gestational age at delivery (P = .009). CONCLUSION: Manifestation of CLD in surviving infants with CDH is associated with the prenatally determined observed-to-expected FLV ratio. Early neonatal therapeutic decisions can additionally be based on this ratio. Perinatally, ECMO requirement and gestational age at delivery are useful in further improving the estimated probability of CLD.


Assuntos
Hérnia Diafragmática/epidemiologia , Hérnia Diafragmática/patologia , Lesão Pulmonar/epidemiologia , Lesão Pulmonar/patologia , Medidas de Volume Pulmonar , Imageamento por Ressonância Magnética/estatística & dados numéricos , Diagnóstico Pré-Natal/métodos , Comorbidade , Feminino , Alemanha/epidemiologia , Hérnias Diafragmáticas Congênitas , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Prevalência , Prognóstico , Fatores de Risco , Sensibilidade e Especificidade
18.
Radiology ; 269(3): 730-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24023074

RESUMO

PURPOSE: To study the predictive value of whole-body magnetic resonance (MR) imaging for the occurrence of cardiac and cerebrovascular events in a cohort of patients with diabetes mellitus (DM). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. Informed consent was obtained from all patients before enrollment into the study. The authors followed up 65 patients with DM (types 1 and 2) who underwent a comprehensive, contrast material-enhanced whole-body MR imaging protocol, including brain, cardiac, and vascular sequences at baseline. Follow-up was performed by phone interview. The primary endpoint was a major adverse cardiac and cerebrovascular event (MACCE), which was defined as composite cardiac-cerebrovascular death, myocardial infarction, cerebrovascular event, or revascularization. MR images were assessed for the presence of systemic atherosclerotic vessel changes, white matter lesions, and myocardial changes. Kaplan-Meier survival and Cox regression analyses were performed to determine associations. RESULTS: Follow-up was completed in 61 patients (94%; median age, 67.5 years; 30 women [49%]; median follow-up, 70 months); 14 of the 61 patients (23%) experienced MACCE. Although normal whole-body MR imaging excluded MACCE during the follow-up period (0%; 95% confidence interval [CI]: 0%, 17%), any detectable ischemic and/or atherosclerotic changes at whole-body MR imaging (prevalence, 66%) conferred a cumulative event rate of 20% at 3 years and 35% at 6 years. Whole-body MR imaging summary estimate of disease was strongly predictive for MACCE (one increment of vessel score and each territory with atherosclerotic changes: hazard ratio, 13.2 [95% CI: 4.5, 40.1] and 3.9 [95% CI: 2.2, 7.5], respectively), also beyond clinical characteristics as well as individual cardiac or cerebrovascular MR findings. CONCLUSION: These initial data indicate that disease burden as assessed with whole-body MR imaging confers strong prognostic information in patients with DM. Online supplemental material is available for this article.


Assuntos
Doenças Cardiovasculares/diagnóstico , Transtornos Cerebrovasculares/diagnóstico , Complicações do Diabetes/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total , Idoso , Meios de Contraste , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Entrevistas como Assunto , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Risco
19.
Pancreatology ; 13(5): 553-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24075524

RESUMO

BACKGROUND: The etiology of acute pancreatitis can be manifold, beside the usual causes. We are reporting an unusual cause that triggered acute pancreatitis. PATIENT & RESULTS: A 50 year-old male experienced attacks of acute pancreatitis (abdominal pain and elevated amylase and lipase) during sexual arousal. Serial imaging showed a rapidly-progressing, partly-thrombosed splenic artery aneurysm, with local compression of the pancreas. After angiographic coiling, the attacks subsided. Further angiography revealed additional aneurysms consistent with segmental arterial mediolysis at other sites of the body. Molecular analysis regarding Ehlers-Danlos-syndrome and genetic factors for pancreatitis, autoantibodies and Syphilis serology was negative. CONCLUSIONS: Acute pancreatitis was triggered by a transient rise in blood pressure during sexual stimulation, which caused rapid progression of a splenic artery aneurysm as part of systemic segmental arterial mediolysis.


Assuntos
Aneurisma/complicações , Pancreatite/etiologia , Artéria Esplênica , Dor Abdominal/etiologia , Aneurisma/diagnóstico por imagem , Aneurisma Roto/complicações , Pressão Sanguínea , Humanos , Masculino , Radiografia , Radiologia Intervencionista , Disfunções Sexuais Psicogênicas/complicações
20.
Eur Radiol ; 23(6): 1669-77, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23314598

RESUMO

OBJECTIVE: A new technology is introduced that enables real-time 4D (three spatial dimensions plus time) X-ray guidance for vascular catheter interventions with acceptable levels of ionising radiation. METHODS: The enabling technology is a combination of low-dose tomographic data acquisition with novel compressed sensing reconstruction and use of prior image information. It was implemented in a prototype set-up consisting of a gantry-based flat detector system. In pigs (n = 5) angiographic interventions were simulated. Radiation dosage on a per time base was compared with the "gold standard" of X-ray projection imaging. RESULTS: Contrary to current image guidance methods that lack permanent 4D updates, the spatial position of interventional instruments could be resolved in continuous, spatial 4D guidance; the movement of the guide wire as well as the expansion of stents could be precisely tracked in 3D angiographic road maps. Dose rate was 23.8 µGy/s, similar to biplane standard angiographic fluoroscopy, which has a dose rate of 20.6 µGy/s. CONCLUSION: Real-time 4D X-ray image-guidance with acceptable levels of radiation has great potential to significantly influence the field of minimally invasive medicine by allowing faster and safer interventions and by enabling novel, much more complex procedures for vascular and oncological minimally invasive therapy. KEY POINTS: • Real-time 4D (three spatial dimensions plus time) angiographic intervention guidance is realistic. • Low-dose tomographic data acquisition with special compressed sensing-based algorithms is enabled. • Compared with 4D CT fluoroscopy, this method reduces radiation to acceptable levels. • Once implemented, vascular interventions may become safer and faster. • More complex intervention approaches may be developed.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Angiografia/métodos , Animais , Catéteres , Fluoroscopia/métodos , Humanos , Doses de Radiação , Radiação Ionizante , Interpretação de Imagem Radiográfica Assistida por Computador , Radiologia Intervencionista/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Suínos , Resultado do Tratamento , Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa