Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Ultraschall Med ; 38(5): 523-529, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27486794

RESUMO

Purpose Inhomogeneity of arterial wall thickness may be indicative of distal plaques. This study investigates the intra-subject association between relative spatial intima-media thickness (IMT) inhomogeneity of the common carotid artery (CCA) and the degree of stenosis of plaques in the internal carotid artery (ICA). Materials and Methods We included 240 patients with a recent ischemic stroke or transient ischemic attack and mild-to-moderate stenosis in the ipsilateral ICA. IMT inhomogeneity was extracted from B-mode ultrasound recordings. The degree of ICA stenosis was assessed on CT angiography according to the European Carotid Surgery Trial method. Patients were divided into groups with a low (≤ 2 %) and a high (> 2 %) IMT inhomogeneity scaled with respect to the local end-diastolic diameter. Results 182 patients had suitable CT and ultrasound measurements. Relative CCA-IMT inhomogeneity was similar for the symptomatic and asymptomatic side (difference: 0.02 %, p = 0.85). High relative IMT inhomogeneity was associated with a larger IMT (difference: 235 µm, p < 0.001) and larger degree of ICA stenosis (difference: 5 %, p = 0.023) which remained significant (p = 0.016) after adjustment for common risk factors. Conclusion Regardless of common risk factors, high relative CCA-IMT inhomogeneity is associated with a greater degree of ICA stenosis and is therefore indicative of atherosclerotic disease. The predictive value of CCA-IMT inhomogeneity for plaque progression and recurrence of cerebrovascular symptoms will be determined in the follow-up phase of PARISK.


Assuntos
Artéria Carótida Interna , Espessura Intima-Media Carotídea , Estenose das Carótidas , Artéria Carótida Primitiva , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Humanos , Fatores de Risco , Túnica Média
2.
Stroke ; 45(11): 3423-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25256179

RESUMO

BACKGROUND AND PURPOSE: In patients with mild to moderate symptomatic carotid artery stenosis, intraplaque hemorrhage (IPH) and a thin/ruptured fibrous cap (FC) as evaluated with MRI, and the presence of microembolic signals (MESs) as detected with transcranial Doppler, are associated with an increased risk of a (recurrent) stroke. The objective of the present study is to determine whether the prevalence of MES differs in patients with and without IPH and thin/ruptured FC, and patients with only a thin/ruptured FC without IPH. METHODS: In this multicenter, diagnostic cohort study, patients with recent transient ischemic attack or minor stroke in the carotid territory and an ipsilateral mild to moderate carotid artery plaque were included. IPH and FC status were dichotomously scored. Analysis of transcranial Doppler data was done blinded for the MRI results. Differences between groups were analyzed with Fisher exact test. RESULTS: A total of 113 patients were included. Transcranial Doppler measurements were feasible in 105 patients (average recording time, 219 minutes). A total of 26 MESs were detected in 8 of 105 patients. In 44 of 105 plaques IPH was present. In 92 of 105 plaques FC status was assessable, 36 of these had a thin/ruptured FC. No significant difference in the prevalence of MES between patients with and without IPH (P=0.46) or with thick versus thin/ruptured FC (P=0.48) was found. CONCLUSIONS: In patients with a symptomatic mild to moderate carotid artery stenosis, IPH and FC status are not associated with MES. This suggests that MRI and transcranial Doppler provide different information on plaque vulnerability. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01709045.


Assuntos
Estenose das Carótidas/diagnóstico , Hemorragia Cerebral/diagnóstico , Embolia Intracraniana/diagnóstico , Microcirculação , Placa Aterosclerótica/diagnóstico , Idoso , Estenose das Carótidas/epidemiologia , Hemorragia Cerebral/epidemiologia , Estudos de Coortes , Feminino , Humanos , Embolia Intracraniana/epidemiologia , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Placa Aterosclerótica/epidemiologia , Método Simples-Cego
3.
Ultrasound Med Biol ; 42(2): 586-95, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26525651

RESUMO

Local arterial stiffness can be assessed with high accuracy and precision by measuring arterial distension on the basis of phase tracking of radiofrequency ultrasound signals acquired at a high frame rate. However, in clinical practice, B-mode ultrasound registrations are made at a low frame rate (20-50 Hz). We compared the accuracy and intra-subject precision of edge tracking and phase tracking distension in symptomatic carotid artery patients. B-mode ultrasound recordings (40 mm, 37 fps) and radiofrequency recordings (31 lines covering 29 mm, 300 fps) were acquired from the left common carotid artery of 30 patients (aged 45-88 y) with recent cerebrovascular events. To extract the distension, semi-automatic echo edge and phase tracking algorithms were applied to B-mode and radiofrequency recordings, respectively. Both methods exhibited a similar intra-subject precision for distension (standard deviation = 44 µm and 47 µm, p = 0.66) and mean distension (difference: -6 ± 69 µm, p = 0.67). Intra-subject distension inhomogeneity tends to be larger for edge tracking (difference: 15 ± 35 µm, p = 0.04). Standard B-mode scanners are suitable for measuring local artery characteristics in symptomatic carotid artery patients with good precision and accuracy.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Rigidez Vascular , Idoso , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa