Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Emerg Med ; 21(1): 90, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34330219

RESUMO

BACKGROUND: Endotracheal intubation continues to be the gold standard for securing the airway in emergency situations. Difficult intubation is still a dreadful situation when securing the airway. OBJECTIVE: To compare VieScope with Glidescope and conventional Macintosh laryngoscopy (MAC) in a simulated difficult airway situation. METHODS: In this randomized controlled simulation trial, 35 anesthesiologists performed endotracheal intubation using VieScope, GlideScope and MAC in a randomized order on a certified airway manikin with difficult airway. RESULTS: For the primary endpoint of correct tube position, no statistical difference was found (p = 0.137). Time until intubation for GlideScope (27.5 ± 20.3 s) and MAC (20.8 ± 8.1 s) were shorter compared to the VieScope (36.3 ± 10.1 s). Time to first ventilation, GlideScope (39.3 ± 21.6 s) and MAC (31.9 ± 9.5 s) were also shorter compared to the VieScope (46.5 ± 12.4 s). There was no difference shown between handling time for VieScope (20.7 ± 7.0 s) and time until intubation with GlideScope or MAC. Participants stated a better Cormack & Lehane Score with VieScope, compared to direct laryngoscopy. CONCLUSION: Rate of correct tracheal tube position was comparable between the three devices. Time to intubation and ventilation were shorter with MAC and Glidescope compared to VieScope. It did however show a comparable handling time to video laryngoscopy and MAC. It also did show a better visualization of the airway in the Cormack & Lehane Score compared to MAC. TRIAL REGISTRATION: The study was registered at the German Clinical Trials Register www.drks.de (Identifier: DRKS00024968 ) on March 31st 2021.


Assuntos
Intubação Intratraqueal , Laringoscópios , Adolescente , Adulto , Idoso , Manuseio das Vias Aéreas , Desenho de Equipamento , Humanos , Laringoscopia , Manequins , Pessoa de Meia-Idade , Gravação em Vídeo , Adulto Jovem
3.
J Clin Med ; 11(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143008

RESUMO

In this model of massive gastric aspiration, we compared two different laryngoscopes (VieScope and Macintosh) in a randomized, controlled simulation study. The primary endpoint was time to intubation; the secondary endpoints were intubation success (i.e., tracheal tube position) and amount of pulmonary aspiration. Thirty-four anesthetists performed endotracheal intubation using VieScope and Macintosh laryngoscopy in a randomized order on an airway manikin simulating massive regurgitation of gastric fluid. The primary endpoint "time until intubation" could be achieved significantly faster (mean −12.4 s [95% confidence intervals (CI) −19.7 s; −7.3 s]) with Macintosh compared to VieScope (p < 0.001). Concerning "correct tube position", no statistical difference was found between the devices (p = 1.0). The mean time to first ventilation was −11.1 s [95% CI −18.3 s; −5.3 s] when using Macintosh (p = 0.001). The mean volume of aspirated gastric fluid was lower in the Macintosh group: −90.0 mL [95% CI −235.0 mL; −27.5 mL] (p = 0.011). Data from this simulation study suggest that in a model of massive gastric regurgitation, airway management can be achieved faster and with less gastric aspiration when using a Macintosh laryngoscope compared to a VieScope laryngoscope.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa