Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
2.
Eur Radiol ; 30(4): 2031-2040, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31822970

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of a deep learning algorithm for automated detection of small 18F-FDG-avid pulmonary nodules in PET scans, and to assess whether novel block sequential regularized expectation maximization (BSREM) reconstruction affects detection accuracy as compared to ordered subset expectation maximization (OSEM) reconstruction. METHODS: Fifty-seven patients with 92 18F-FDG-avid pulmonary nodules (all ≤ 2 cm) undergoing PET/CT for oncological (re-)staging were retrospectively included and a total of 8824 PET images of the lungs were extracted using OSEM and BSREM reconstruction. Per-slice and per-nodule sensitivity of a deep learning algorithm was assessed, with an expert readout by a radiologist/nuclear medicine physician serving as standard of reference. Receiver-operator characteristic (ROC) curve of OSEM and BSREM were assessed and the areas under the ROC curve (AUC) were compared. A maximum standardized uptake value (SUVmax)-based sensitivity analysis and a size-based sensitivity analysis with subgroups defined by nodule size was performed. RESULTS: The AUC of the deep learning algorithm for nodule detection using OSEM reconstruction was 0.796 (CI 95%; 0.772-0.869), and 0.848 (CI 95%; 0.828-0.869) using BSREM reconstruction. The AUC was significantly higher for BSREM compared to OSEM (p = 0.001). On a per-slice analysis, sensitivity and specificity were 66.7% and 79.0% for OSEM, and 69.2% and 84.5% for BSREM. On a per-nodule analysis, the overall sensitivity of OSEM was 81.5% compared to 87.0% for BSREM. CONCLUSIONS: Our results suggest that machine learning algorithms may aid detection of small 18F-FDG-avid pulmonary nodules in clinical PET/CT. AI performed significantly better on images with BSREM than OSEM. KEY POINTS: • The diagnostic value of deep learning for detecting small lung nodules (≤ 2 cm) in PET images using BSREM and OSEM reconstruction was assessed. • BSREM yields higher SUVmaxof small pulmonary nodules as compared to OSEM reconstruction. • The use of BSREM translates into a higher detectability of small pulmonary nodules in PET images as assessed with artificial intelligence.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Inteligência Artificial , Feminino , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/patologia , Nódulos Pulmonares Múltiplos/secundário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/patologia , Nódulo Pulmonar Solitário/secundário
3.
Eur J Nucl Med Mol Imaging ; 46(4): 889-900, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30488099

RESUMO

PURPOSE: The fast-increasing use of positron emission tomography (PET) with prostate-specific membrane antigen (PSMA) ligand for the imaging of prostate cancer (PCA) biochemical recurrence has led to a rapid change in treatment concepts. Since the superiority of 68Ga-PSMA-11 PET in detecting recurrent PCA is well established, the aim of our study was to assess its effect on management and outcome in all patients imaged during the first year after its introduction into clinical routine. METHODS: Of 327 patients imaged, 223 were referred for recurrent PCA and gave written informed consent for further analysis of their data for this retrospective consecutive cohort analysis. Twenty patients were lost to further follow-up. The rate of detection of recurrence by 68Ga-PSMA-11 PET was based on the clinical reports. Management before the availability of PET diagnostic information was assessed according to guidelines (therapy option without 68Ga-PSMA-11 PET). In the 203 patients with follow-up 6 months after 68Ga-PSMA-11 PET, the therapies effectively implemented as well as follow-up PSA levels were evaluated, with a PSA value of <0.2 ng/ml representing a complete response and a decrease in PSA value of at least 50% from baseline representing a partial response. RESULTS: 68Ga-PSMA-11 PET was positive and identified recurrence in 166 of the 223 patients (74%), with a detection rate of 50% for recurrent disease at low PSA values of <0.5 ng/ml. 68Ga-PSMA-11 PET led to a change in management in 122 of the 203 patients (60%). A substantial increase in the use of metastasis-targeted treatment and a reduction in the use of systemic treatment were observed, with 59 of the 203 patients (29%) undergoing targeted radiotherapy (RTXa) only, and 20 patients (10%) undergoing RTXa with hormonal therapy as the two most frequently selected therapy options. The proportion of patients in whom systemic therapy was selected decreased from 60% (133 of 223 patients) to 34% (70 of 203 patients) on the basis of the information provided by the 68Ga-PSMA-11 PET scan. PSMA PET-directed metastasis-targeted treatment led to a complete response after 6 months in 45% of patients. CONCLUSION: The high rate of recurrence detection by PSMA PET was confirmed and PSMA PET led to a change in management in 60% of patients. Focal therapy for PSMA-positive lesions is a promising approach with complete responses in 45% of patients.


Assuntos
Ácido Edético/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Radiol ; 25(8): 2222-30, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26017734

RESUMO

PURPOSE: To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. MATERIAL AND METHODS: Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). RESULTS: Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. CONCLUSION: PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. KEY POINTS: • PET/MRI is superior to PET/CT for primary tumour delineation • PET/CT represents a reliable tool to detect extra-abdominal distant metastasis • PET/MRI might be the preferred imaging modality for staging cervical and endometrial tumours • Whole-body staging for detection and evaluation of extra-abdominal metastases is mandatory.


Assuntos
Neoplasias dos Genitais Femininos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Neoplasias dos Genitais Femininos/terapia , Humanos , Linfonodos/patologia , Metástase Linfática , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Metástase Neoplásica , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos
5.
Radiology ; 273(3): 859-69, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25102372

RESUMO

PURPOSE: To assess the diagnostic performance of whole-body non-contrast material-enhanced positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for staging and restaging of cancers and provide guidance for modality and sequence selection. MATERIALS AND METHODS: This study was approved by the institutional review board and national government authorities. One hundred six consecutive patients (median age, 68 years; 46 female and 60 male patients) referred for staging or restaging of oncologic malignancies underwent whole-body imaging with a sequential trimodality PET/CT/MR system. The MR protocol included short inversion time inversion-recovery ( STIR short inversion time inversion-recovery ), Dixon-type liver accelerated volume acquisition ( LAVA liver accelerated volume acquisition ; GE Healthcare, Waukesha, Wis), and respiratory-gated periodically rotated overlapping parallel lines with enhanced reconstruction ( PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction ; GE Healthcare) sequences. Primary tumors (n = 43), local lymph node metastases (n = 74), and distant metastases (n = 66) were evaluated for conspicuity (scored 0-4), artifacts (scored 0-2), and reader confidence on PET/CT and PET/MR images. Subanalysis for lung lesions (n = 46) was also performed. Relevant incidental findings with both modalities were compared. Interreader agreement was analyzed with intraclass correlation coefficients and κ statistics. Lesion conspicuity, image artifacts, and incidental findings were analyzed with nonparametric tests. RESULTS: Primary tumors were less conspicuous on STIR short inversion time inversion-recovery (3.08, P = .016) and LAVA liver accelerated volume acquisition (2.64, P = .002) images than on CT images (3.49), while findings with the PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction sequence (3.70, P = .436) were comparable to those at CT. In distant metastases, the PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction sequence (3.84) yielded better results than CT (2.88, P < .001). Subanalysis for lung lesions yielded similar results (primary lung tumors: CT, 3.71; STIR short inversion time inversion-recovery , 3.32 [P = .014]; LAVA liver accelerated volume acquisition , 2.52 [P = .002]; PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction , 3.64 [P = .546]). Readers classified lesions more confidently with PET/MR than PET/CT. However, PET/CT showed more incidental findings than PET/MR (P = .039), especially in the lung (P < .001). MR images had more artifacts than CT images. CONCLUSION: PET/MR performs comparably to PET/CT in whole-body oncology and neoplastic lung disease, with the use of appropriate sequences. Further studies are needed to define regionalized PET/MR protocols with sequences tailored to specific tumor entities.


Assuntos
Imagem Multimodal , Neoplasias/patologia , Imagem Corporal Total , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Metástase Linfática , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
6.
Eur J Nucl Med Mol Imaging ; 41(6): 1066-75, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24577950

RESUMO

PURPOSE: Positron emission tomography (PET)/MRI combines the functional ability of PET and the high soft tissue contrast of MRI. The aim of this study was to assess contrast-enhanced (ce)PET/MRI compared to cePET/CT in patients with suspected recurrence of head and neck cancer (HNC). METHODS: Eighty-seven patients underwent sequential cePET/CT and cePET/MRI using a trimodality PET/CT-MRI set-up. Diagnostic accuracy for the detection of recurrent HNC was evaluated using cePET/CT and cePET/MRI. Furthermore, image quality, presence of unclear (18)F-fluorodeoxy-D-glucose (FDG) findings of uncertain significance and the diagnostic advantages of use of gadolinium contrast enhancement were analysed. RESULTS: cePET/MRI showed no statistically significant difference in diagnostic accuracy compared to cePET/CT (91.5 vs 90.6%). Artefacts' grade was similar in both methods, but their location was different. cePET/CT artefacts were primarily located in the suprahyoid area, while on cePET/MRI, artefacts were more equally distributed among the supra and infrahyoid neck regions. cePET/MRI and cePET/CT showed 34 unclear FDG findings; of those 11 could be solved by cePET/MRI and 5 by cePET/CT. The use of gadolinium in PET/MRI did not yield higher diagnostic accuracy, but helped to better define tumour margins in 6.9% of patients. CONCLUSION: Our data suggest that cePET/MRI may be superior compared to cePET/CT to specify unclear FDG uptake related to possible tumour recurrence in follow-up of patients after HNC. It seems to be the modality of choice for the evaluation of the oropharynx and the oral cavity because of a higher incidence of artefacts in cePET/CT in this area mainly due to dental implants. However, overall there is no statistically significant difference.


Assuntos
Carcinoma/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma/diagnóstico , Feminino , Fluordesoxiglucose F18 , Seguimentos , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Compostos Radiofarmacêuticos
7.
Eur J Nucl Med Mol Imaging ; 41(12): 2212-21, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25091219

RESUMO

OBJECTIVE: The purpose of this study was to analyze whether diffusion-weighted imaging (DWI) adds significant information to positron emission tomography/magnetic resonance imaging (PET/MRI) on lesion detection and characterization in head and neck cancers. METHODS: Seventy patients with different head and neck cancers were enrolled in this prospective study. All patients underwent sequential contrast-enhanced (ce) PET/computed tomography (CT) and cePET/MRI using a tri-modality PET/CT-MR setup either for staging or re-staging. First, the DWI alone was evaluated, followed by the PET/MRI with conventional sequences, and in a third step, the PET/MRI with DWI was evaluated. McNemar's test was used to evaluate differences in the accuracy of PET/MRI with and without DWI compared to the standard of reference. RESULTS: One hundred eighty-eight (188) lesions were found, and of those, 118 (62.8%) were malignant and 70 (37.2%) were benign. PET/MRI without DWI had a higher accuracy in detecting malignant lesions than DWI alone (86.8% vs. 60.6%, p < 0.001). PET/MRI combined with DWI detected 120 concurrent lesions (89 malignant and 31 benign), PET/MRI alone identified 48 additional lesions (20 malignant and 28 benign), and DWI alone detected 20 different lesions (nine malignant and 11 benign). However, lesions detected on DWI did not change overall staging. SUV maximum and mean were significantly higher in malignant lesions than in benign lesions. DWI parameters between malignant and benign lesions were not statistically different. CONCLUSION: The use of DWI as part of PET/MRI to evaluate head and neck cancers does not provide remarkable information. Thus, the use of DWI might not be needed in clinical PET/MRI protocols for the staging or restaging of head and neck cancers.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
8.
Eur J Nucl Med Mol Imaging ; 41(4): 649-58, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24346415

RESUMO

PURPOSE: To compare the accuracy of PET/MR imaging with that of FDG PET/CT and to determine the MR sequences necessary for the detection of liver metastasis using a trimodality PET/CT/MR set-up. METHODS: Included in this single-centre IRB-approved study were 55 patients (22 women, age 61 ± 11 years) with suspected liver metastases from gastrointestinal cancer. Imaging using a trimodality PET/CT/MR set-up (time-of-flight PET/CT and 3-T whole-body MR imager) comprised PET, low-dose CT, contrast-enhanced (CE) CT of the abdomen, and MR with T1-W/T2-W, diffusion-weighted (DWI), and dynamic CE imaging. Two readers evaluated the following image sets for liver metastasis: PET/CT (set A), PET/CECT (B), PET/MR including T1-W/T2-W (C), T1-W/T2-W with either DWI (D) or CE imaging (E), and a combination (F). The accuracy of each image set was determined by receiver-operating characteristic analysis using image set B as the standard of reference. RESULTS: Of 120 liver lesions in 21/55 patients (38%), 79 (66%) were considered malignant, and 63/79 (80%) showed abnormal FDG uptake. Accuracies were 0.937 (95% CI 89.5 - 97.9%) for image set A, 1.00 (95% CI 99.9 - 100.0%) for set C, 0.998 (95% CI 99.4 - 100.0%) for set D, 0.997 (95% CI 99.3 - 100.0%) for set E, and 0.995 (95% CI 99.0 - 100.0%) for set F. Differences were significant for image sets D - F (P < 0.05) when including lesions without abnormal FDG uptake. As shown by follow-up imaging after 50 - 177 days, the use of image sets D and both sets E and F led to the detection of metastases in one and three patients, respectively, and further metastases in the contralateral lobe in two patients negative on PET/CECT (P = 0.06). CONCLUSION: PET/MR imaging with T1-W/T2-W sequences results in similar diagnostic accuracy for the detection of liver metastases to PET/CECT. To significantly improve the characterization of liver lesions, we recommend the use of dynamic CE imaging sequences. PET/MR imaging has a diagnostic impact on clinical decision making.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Protocolos Clínicos , Feminino , Neoplasias Gastrointestinais/patologia , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
MAGMA ; 26(1): 25-35, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23053712

RESUMO

Tri-modality PET/CT-MRI includes the transfer of the patient on a dedicated shuttle from one system into the other. Advantages of this system include a true CT-based attenuation correction, reliable PET-quantification and higher flexibility in patient throughput on both systems. Comparative studies of PET/MRI versus PET/CT are readily accomplished without repeated PET with a different PET scanner at a different time point. Additionally, there is a higher imaging flexibility based on the availability of three imaging modalities, which can be combined for the characterization of the disease. The downside is a somewhat higher radiation dose of up to 3 mSv with a low dose CT based on the CT-component, longer acquisition times and potential misalignment between the imaging components. Overall, the tri-modality PET/CT-MR system offers comparative studies using the three different imaging modalities in the same patient virtually at the same time, and may help to develop reliable attenuation algorithms at the same time.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
10.
Eur J Nucl Med Mol Imaging ; 39(7): 1154-60, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22526955

RESUMO

PURPOSE: Accurate attenuation correction (AC) is essential for quantitative analysis of PET tracer distribution. In MR, the lack of cortical bone signal makes bone segmentation difficult and may require implementation of special sequences. The purpose of this study was to evaluate the need for accurate bone segmentation in MR-based AC for whole-body PET/MR imaging. METHODS: In 22 patients undergoing sequential PET/CT and 3-T MR imaging, modified CT AC maps were produced by replacing pixels with values of >100 HU, representing mostly bone structures, by pixels with a constant value of 36 HU corresponding to soft tissue, thereby simulating current MR-derived AC maps. A total of 141 FDG-positive osseous lesions and 50 soft-tissue lesions adjacent to bones were evaluated. The mean standardized uptake value (SUVmean) was measured in each lesion in PET images reconstructed once using the standard AC maps and once using the modified AC maps. Subsequently, the errors in lesion tracer uptake for the modified PET images were calculated using the standard PET image as a reference. RESULTS: Substitution of bone by soft tissue values in AC maps resulted in an underestimation of tracer uptake in osseous and soft tissue lesions adjacent to bones of 11.2 ± 5.4% (range 1.5-30.8%) and 3.2 ± 1.7% (range 0.2-4%), respectively. Analysis of the spine and pelvic osseous lesions revealed a substantial dependence of the error on lesion composition. For predominantly sclerotic spine lesions, the mean underestimation was 15.9 ± 3.4% (range 9.9-23.5%) and for osteolytic spine lesions, 7.2 ± 1.7% (range 4.9-9.3%), respectively. CONCLUSION: CT data simulating treating bone as soft tissue as is currently done in MR maps for PET AC leads to a substantial underestimation of tracer uptake in bone lesions and depends on lesion composition, the largest error being seen in sclerotic lesions. Therefore, depiction of cortical bone and other calcified areas in MR AC maps is necessary for accurate quantification of tracer uptake values in PET/MR imaging.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Adulto , Idoso , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/patologia , Fluordesoxiglucose F18/farmacocinética , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
Eur J Nucl Med Mol Imaging ; 38(1): 90-6, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20857098

RESUMO

PURPOSE: The aim of the study was to determine the aetiology of FDG uptake in vaginal tampons (VT), a known artefact in premenopausal women evaluated by PET/CT. METHODS: This Institutional Review Board approved study consisted of retrospective and prospective parts. The retrospective analysis included 685 women examined between January 2008 and December 2009 regarding VT presence. PET/CT images were analysed to determine the localization and the standardized uptake value (SUV) of VTs. We prospectively recruited 24 women (20-48 years old) referred for staging or follow-up in an oncology setting between February and April 2010, who were provided a commercial VT to be used during the entire examination after obtaining written informed consent. After image acquisition, VTs were individually analysed for creatinine concentration and blood traces. Statistical significance was tested with the Mann-Whitney U test. RESULTS: In the retrospective part, 38 of 685 women were found to have a VT of which 17 (45%) were FDG positive. A statistically significant correlation was found between FDG activity and VT position below the pubococcygeal line (PCL) (13 ± 11.2 mm). In the prospective study, 7 of 24 (29%) women had increased FDG activity in their VTs (SUV 18.8 ± 11 g/ml) but were not menstruating. FDG-positive VTs were significantly lower in position (14.6 ± 11.4 mm,below the PCL) than FDG-negative VTs (p = 0.039). The creatinine concentration was significantly increased in all seven positive VTs (931 ± 615 µmol/l). CONCLUSION: FDG uptake in VTs is caused by urine contamination, which is likely related to localization below the PCL resulting in contact with urine during voiding.


Assuntos
Artefatos , Fluordesoxiglucose F18/metabolismo , Produtos de Higiene Menstrual , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Urina , Adulto , Transporte Biológico , Feminino , Corpos Estranhos , Humanos , Ciclo Menstrual , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Vagina/metabolismo , Adulto Jovem
12.
Eur Radiol ; 21(2): 246-55, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20717828

RESUMO

OBJECTIVE: To prospectively evaluate the diagnostic accuracy of whole-body T2-weighted (wbT2), whole-body diffusion-weighted imaging (wbDWI) and wbT2/wbDWI image fusion for malignant tumour detection compared with PET/CT. METHODS: Sixty-eight patients (44 men; 60 ± 14 years) underwent PET/CT for staging of malignancy and were consecutively examined by 1.5-Tesla MRI including wbT2 and wbDWI. Two radiologists independently assessed wbDWI, wbT2, wbT2 + wbDWI (side-by-side) and wbT2 + wbDWI + wbT2/wbDWI image fusion for the presence of malignancy. PET/CT served as a reference standard. RESULTS: PET/CT revealed 374 malignant lesions in 48/64 (75%) patients. Detection rates and positive predictive value (PPV) of wbT2 and wbDWI alone were 64% and 84%, and 57% and 93%, respectively. Detection rates and PPV of wbT2 and wbDWI for side-by-side analysis without and with fused images were 72% and 89%, and 74% and 91%, respectively. The detection rate was significantly higher with side-by-side analysis and fused image analysis compared with wbT2 and wbDWI alone (p = .0159; p < .0001). There was no significant difference between fused image interpretation and side-by-side analysis. CONCLUSIONS: WbDWI allows detection of malignant lesions with a similar detection rate to wbT2. Side-by-side analysis of wbT2 and wbDWI significantly improves the overall detection rate and fused image data provides no added value.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons , Técnica de Subtração , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Radiology ; 257(2): 498-506, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20829539

RESUMO

At the 2009 Scientific Assembly and Annual Meeting of the Radiological Society of North America, a special session was devoted to global trends in hybrid imaging. This article expands on the key points of the session, focusing primarily on positron emission tomography/computed tomography. Global trends in hybrid imaging equipment acquisition, usage, and image interpretation practices are reviewed, and emerging requirements for training and clinical privileging are discussed. Also considered are the current benefits of hybrid imaging for patient care and workflow and the potential of hybrid imaging for advancing drug development and personalized medicine.


Assuntos
Tomografia por Emissão de Pósitrons/tendências , Tomografia Computadorizada por Raios X/tendências , Congressos como Assunto , Desenho de Fármacos , Humanos , Interpretação de Imagem Assistida por Computador , Cooperação Internacional , Medicina de Precisão , Sociedades Médicas
14.
Eur J Nucl Med Mol Imaging ; 37(5): 980-90, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20140613

RESUMO

PURPOSE: From a workflow/cost perspective integrated imaging is not an obvious solution. An analysis of scanning costs as a function of system cost and relevant imaging times is presented. This analysis ignores potential clinical advantages of integrated imaging. METHODS: An analysis comparing separate vs integrated imaging costs was performed by deriving pertinent equations and using reasonable cost numbers for imaging devices and systems, room and other variable costs. Integrated systems were divided into those sequentially and simultaneously. Sequential scanning can be done with two devices placed in a single or in two different scanning rooms. Graphs were derived which represent the cost difference between integrated imaging system options and their separate counterparts vs scanning time on one of the devices and cost ratio of an integrated system and its counterpart of separate devices. RESULTS: Integrated systems are favoured by the fact that patients have to be up- and downloaded only once. If imaging times become longer than patient changing times, imaging on separate devices is advantageous. An integrated imaging cost advantage is achieved if the integrated systems typically and overall cost three fourths or less of the separate systems. If PET imaging takes 15 min or less, PET/CT imaging costs less than separate PET and CT imaging, while this time is below 5 min for SPECT/CT. A two-room integrated system has the added advantage that patient download time is not cost relevant, when imaging times on the two devices differ by more than the patient download time. CONCLUSION: PET/CT scanning is a cost-effective implementation of an integrated system unlike most current SPECT/CT systems. Integration of two devices in two rooms by a shuttle seems the way how to make PET/MR cost-effective and may well also be a design option for SPECT/CT systems.


Assuntos
Diagnóstico por Imagem/métodos , Integração de Sistemas , Diagnóstico por Imagem/economia , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
15.
Eur J Nucl Med Mol Imaging ; 37(9): 1760-5, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20505935

RESUMO

PURPOSE: The aim of this study was to evaluate the performance of (18)F-fluoride-PET/CT (PET/CT) for the diagnosis of sacroiliac joint (SIJ) arthritis in patients with active ankylosing spondylitis (AS). METHODS: Included in the study were 15 patients with AS according to the modified New York criteria (AS group) and with active disease and 13 patients with mechanical low back pain (MLBP; control group) who were investigated with whole-body (18)F-fluoride PET/CT. The ratio of the uptake in the SIJ and that in the sacrum (SIJ/S) was calculated for every joint. RESULTS: The mean SIJ/S ratio of 30 quantified joints in the AS group was 1.66 (range 1.10-3.07) with PET/CT, and the mean SIJ/S ratio of 26 quantified joints in the MLBP group was 1.12 (range 0.71-1.52). The area under the receiver operating characteristic curve for SIJ arthritis was 0.84. With plain radiography as a the gold standard and taking an SIJ/S ratio of >1.3 as the threshold, the sensitivity, specificity and accuracy on a per patient basis were 80%, 77% and 79%, respectively. On a per SIJ basis, the greatest sensitivity (94%) was found in grade 3 sacroiliitis (n = 16). CONCLUSION: Our results suggest that quantitative (18)F-fluoride PET/CT may play a role in the diagnosis of sacroiliitis in active AS and is an alternative to conventional bone scintigraphy in times of molybdenum shortage.


Assuntos
Fluoretos , Radioisótopos de Flúor , Tomografia por Emissão de Pósitrons , Articulação Sacroilíaca/diagnóstico por imagem , Espondilite Anquilosante/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Feminino , Fluoretos/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Articulação Sacroilíaca/metabolismo , Sacro/metabolismo , Espondilite Anquilosante/diagnóstico por imagem , Espondilite Anquilosante/metabolismo
16.
Skeletal Radiol ; 39(10): 987-97, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20174985

RESUMO

PURPOSE: To evaluate the therapeutic impact of [(18)F]fluoride positron-emission tomography/computed tomography ([(18)F]fluoride PET/CT) imaging on patients with unclear foot pain. METHODS: Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [(18)F]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. RESULTS: In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. CONCLUSION: [(18)F]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain.


Assuntos
Fluordesoxiglucose F18 , Doenças do Pé/diagnóstico , Doenças do Pé/terapia , Manejo da Dor , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Pé/diagnóstico por imagem , Doenças do Pé/complicações , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Dor/etiologia , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos
17.
Nucl Med Commun ; 41(5): 452-458, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32187162

RESUMO

AIM: The mylohyoid muscle is often believed to exhibit high physiologic fluoro-deoxy-glucose (FDG) uptake. Aim of this study was to use PET/MR for adequately assessing the normal FDG distribution in floor of the mouth (FOM) muscles and neighboring major salivary glands. MATERIALS AND METHODS: Patients scanned with a simultaneous PET/MRI system for initial staging or follow-up of head and neck tumors, with no malignant lesions in salivary glands or in FOM, were included. Volumes-of-interest (VOIs) were positioned separately for bilateral mylohyoid, digastric, genioglossus, and geniohyoid muscles, based on T2-weighted and T1-weighted images, and for bilateral parotid, submandibular, and sublingual glands in the same way. SUVmax was measured for each VOI. RESULTS: Six hundred and ninety-two VOIs were positioned. FDG uptake in mylohyoid (SUVmax = 1.94 ± 0.37) and digastric muscles (SUVmax = 2.01 ± 0.37) were significantly higher compared to that in geniohyoid (SUVmax = 1.67 ± 0.53) and genioglossus muscles (SUVmax = 1.75 ± 0.54) (Friedman's test; P < 0.001). FDG uptake in the sublingual glands (SUVmax = 3.77 ± 1.63) was significantly higher compared to the parotid glands (SUVmax = 2.34 ± 0.60) and submandibular glands (SUVmax = 2.51 ± 0.59) (Wilcoxon signed-ranks test; P < 0.001). FDG uptake in sublingual glands was significantly higher than FDG uptake in the mylohyoid muscles (P < 0.001). FDG uptake in the parotid, submandibular, and sublingual glands was inversely correlated to the age of subjects (Spearman' rho coefficient: -0.397/P = 0.004; -0.329/P = 0.021; -0.535/P < 0.001, respectively). CONCLUSION: The sublingual glands yield the highest physiologic FDG uptake in the FOM. High FDG uptake in the mylohyoid muscle is a common misconception.


Assuntos
Fluordesoxiglucose F18/metabolismo , Boca , Músculos/diagnóstico por imagem , Músculos/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Transporte Biológico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
18.
Eur J Nucl Med Mol Imaging ; 36 Suppl 1: S3-9, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19104804

RESUMO

INTRODUCTION: Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. OBJECTIVES: In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. DISCUSSION: The authors conclude that combining PET/MR is an interesting research endeavor with uncertain outcome. They argue that, while completely simultaneous brain applications are of research interest immediately, clinical applications do not currently warrant the construction of fully integrated systems. Systems adjacent to each other, where imaging tables are linked with a patient "shuttle" thereby requiring only patient translation but no repositioning, may be a good start to assess the value of integrated PET/MR.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Animais , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação
20.
Br J Radiol ; 92(1096): 20180792, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30673302

RESUMO

OBJECTIVE:: Positron emission tomography (PET) using 18F-fludeoxyglucose (18F-FDG) is an established imaging modality for tumor staging in patients with non-small cell lung cancer (NSCLC). There is a growing interest in using 18F-FDG PET for therapy response assessment in NSCLC which relies on quantitative PET parameters such as standardized uptake values (SUV). Different reconstruction algorithms in PET may affect SUV. We sought to determine the variation of SUV in patients with NSCLC when using ordered subset expectation maximization (OSEM) and block sequential regularized expectation maximization (BSREM) in latest-generation digital PET/CT, including a subanalysis for adenocarcinoma and squamous cell carcinoma. METHODS:: A total of 58 patients (34 = adenocarcinoma, 24 = squamous cell carcinoma) who underwent a clinically indicated 18F-FDG PET/CT for staging were reviewed. PET images were reconstructed with OSEM and BSREM reconstruction with noise penalty strength ß-levels of 350, 450, 600, 800 and 1200. Lung tumors maximum standardized uptake value (SUVmax) were compared. RESULTS:: Lung tumors SUVmax were significantly lower in adenocarcinomas compared to squamous cell carcinomas in all reconstructions evaluated (all p < 0.01). Comparing BSREM to OSEM, absolute SUVmax differences were highest in lower ß-levels of BSREM with + 2.9 ± 1.6 in adenocarcinoma and + 4.0 ± 2.9 in squamous cell carcinoma (difference between histology; p-values > 0.05). There was a statistically significant difference of the relative increase of SUVmax in adenocarcinoma (mean + 34.8%) and squamous cell carcinoma (mean 23.4%), when using BSREM350 instead of OSEMTOF (p < 0.05). CONCLUSION:: In NSCLC the relative change of SUV when using BSREM instead of OSEM is significantly higher in adenocarcinoma as compared to squamous cell carcinoma. ADVANCES IN KNOWLEDGE:: The impact of BSREM on SUV may vary in different histological subtypes of NSCLC. This highlights the importance for careful standardization of ß-value used for serial 18F-FDG PET scans when following-up NSCLC patients.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa